SAFETY THE BEST FOR YOUR EQUIPMENT

Similar documents
SPECIAL HAZARDS THE MOST ADVANCED TECHNOLOGY FOR PROTECTING

THE IDEAL SOLUTION FOR KITCHENS

AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS

automatic FiReFighTing SYSTeMS in PainT booths

PROTECCIÓN DE RIESGOS ESPECIALES AUTOMATIC FIREFIGHTING SYSTEMS IN VEHICLES. con tubo de detección

AUTOMATIC FIREFIGHTING SYSTEMS IN KITCHENS

FOREFRONT AT THE OF PROTECTION

CO 2 EXTINGUISHING SYSTEMS

Inert Gas Fire Extinguishing System

FIRE SUPPRESSION SYSTEM

STORED PRESSURE YES TEST STANDARDS: CAN/ULC S504 & ANSI/UL 229 CAN/ULC S508 & ANSI/UL 711. Available Options: Stationary Design Tow Loop

AUTOMATIC FIREFIGHTING SYSTEMS IN HOSPITALS

KD Innovative extinguishing with Novec TM 1230 by 3M TM

Safe, Effective, Environment-friendly

CO 2. fire extinguishing systems

CO2 COCO GAS FLOODING SYSTEM

SECTION FM-200 FIRE SUPPRESSION SYSTEM

Carbon Dioxide Extinguishing Systems Fighting fire with CO2

International Safety Guide Chapter 30 for Inland Navigation Tank-barges and Terminals. Chapter 30 FIRE-FIGHTING

Extinguishers. Commercial Industrial High rise buildings

Innovative cleaning with dry ice: No residue, no chemicals.

PRODUCT MANUAL FIRE EXTINGUISHER. Carbon Dioxide 6.5, 9 & 22.5 Kg Capacity Trolley Mounted (45 kg also as a non standard)

CO2 High Pressure Extinguishing System

GAS EXTINGUISHING SYSTEM INERT GAS. Argotec with carbon dioxide. Safe for certain.

DRY POWDER FIRE EXTINGUISHER (Stored Pressure) ABC TYPE - PORTABLE

Hospitals and Major Medical Centers

w-fog RG-SYSTEMS W-FOG WATER MIST CO-OPERATI

Fire Protection for Catering Kitchens KS 2000 Compact Extinguishing System. Safe for certain.

MAINTENANCE AND INPSECTION OF FIRE PROTECTION SYSTEMS AND APPLIANCES

PORTABLE PERFORMANCE ANSUL Stored Pressure Fire Extinguishers

Fire Protection for Catering Kitchens KS 2000 Compact Extinguishing System. Safe for certain.

BMA INFORMATION BULLETIN No. 97 FIRE FIGHTING EQUIPMENT

Aerosol Type Fire Extinguisher Aerosol Type Fire Extinguisher

Fire protection for buildings

IMO. Resolution A.951(23) Adopted on 5 December 2003 (Agenda item 17) IMPROVED GUIDELINES FOR MARINE PORTABLE FIRE EXTINGUISHERS

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle. TM TM

FIREDETEC PRODUCT TECHNOLOGY: DIRECT & INDIRECT

Detection, and Suppression Systems

SPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM

Carbon Dioxide Fire Suppression Systems

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS

Twin-Agent Fire Fighting/Securing Systems Specifications

A. NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems 2004 edition.

Technologies Gas extinguishing systems. MX 200 Fire Extinguishing Systems Fighting Fire using HFC-227ea

Design and Supply of Fire Equipments. External Fire Fighting Systems.

IB 15/80 Ice Blaster. Innovative cleaning with dry ice: No residue, no chemicals.

LPG ProteK. for commercial kitchens

CARBON DIOXIDE FIRE EXTINGUISHING SYSTEM

SPECIFICATION: Kidde Engineered Fire Suppression System Designed for use with 3M Novec 1230 Fire Protection

Oxeo extinguishing systems

Chapter 2. Alternatives to HCFCs and their Characteristics

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

Amerex Fire Suppression Systems. Because Operators and the Environment are NOT Disposable Quality is Behind the Diamond.

An Overview of Extinguishing Systems for Computer Equipment

IMO INTERPRETATIONS OF FIRE PROTECTION-RELATED PROVISIONS OF THE HSC CODE

PORTABLE FIRE EXTINGUISHERS. Fire Safety.

Aerosol Fire Suppression. Your Choice for Special Hazard Fire Protection

Portable Fire Extinguishers

Superior by Design The Kidde ADS TM FM-200 System

PURPLE K POWDER EXTINGUISHERS INSTALLATION, OPERATION, MAINTENANCE AND RECHARGE MANUAL

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle.

Reflex fire detection and extinguishing system charged with Novec 1230 extinguishing agent. Installation, operation and maintenance instructions

Refrigerant Leak Detection Solutions

Guidance on the construction of CO 2 systems

GAS EXTINGUISHING SYSTEMS INERT GAS. Argotec with argon or nitrogen

Certificate of Conformity Certificate num. Registration date Version Valid until

The Specialist s Choice

CERTIFICATE OF FIRE APPROVAL

COMDTPUB P NVIC JUNE 1995

FIRE EXTINGUISHERS. Chapter 2. - Co2 Fire Extinguisher - Dry Foam Fire Extinguisher - Foam Fire Extinguisher - Portable Foam Applicator

I wish I could protect my business with the most suitable Water Mist solution to fit my needs.

Technologies Gas extinguishing systems. MX 1230 Fire Extinguishing Systems Fighting Fire using 3M Novec 1230

INDEPENDENT FIRE EXTINGUISHER SALES & SERVICES. Your First Line of Defense Since 1971

WHEELED STORED PRESSURE

CO 2 Fire Extinguishing Systems

GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS

Index. + Kleen Kote 200 Concentrate. + Kleen Krete. + Real Pump Power Spraying System. + Real Pump EXPRESS Portable Power Spraying System

Ammonia. Background on ammonia as a refrigerant

Fire Suppression. Water-Mist : A Revolutionary Green Technology in. - by Nimit Sheth TALL, SMART, SAFE BUILDINGS FOR SMART CITIES.

A full range of UK manufactured portable and wheeled fire extinguishers

SPECIFICATION: CARBON DIOXIDE ENGINEERED FIRE SUPPRESSION SYSTEM

Data/ Specification Sheet

PRESTO DRY POWDER FIRE EXTINGUISHERS - AB:E

OUT CARBON DIOXIDE (CO2) EXTINGUISHER Certified & Approved to AS/NZS Lightweight Aluminium Cylinder. AS High pressure hose assembly with

Condensate Management Solutions

Good Ideas For Propane Safety

SUPPRESSION SALES I INSTALLATION I SERVICE

PERFORMANCE AT HAND RED LINE Hand Portable Fire Extinguishers

TAMUCC Fire Safety Training

TRIMAX ASIA ENGINEERING & CONSTRUCTION (PG U )

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

"USING FIRE EXTINGUISHERS"

RESOLUTION MSC.339(91) (adopted on 30 November 2012) AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE)

Fire Safety. Presenter, Kevin V Coleman September 14 th 2016

White Paper. The Victaulic Vortex Fire Suppression System Fire Suppression for Electrical and Electronic Applications

SERVICE MANUAL (v1) UL / ULC. WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK

Capital Projects Group Fire Extinguishers Specification

FIREWORLD DRY POWDER ABE FIRE EXTINGUISHERS

FIRE SAFETY DURING CONSTRUCTION, ALTERATION AND DEMOLITION

PRODUCT LISTING DATA SHEET (Active Fire Protection Equipment)

Transcription:

THE BEST SAFETY FOR YOUR EQUIPMENT The fire protection requirements involve adapting the fixed extinguishing systems to the various needs of the hazard to be protected. In many cases it is necessary to have a robust firefighting system which can be applied by personnel trying to immediately control or extinguish the fire with utmost ease and safety. The rapid and effective response of the extinguishing system is key for minimizing the damage caused by a fire in any space, with special emphasis on spaces housing very expensive equipment or machinery. Adequate protection of equipment and goods is critical to ensure the safety and continuity of your business.

fixed hose and reel stations Traditional hand extinguishers may not be sufficient to extinguish certain risks, so SIEX has developed this advanced CO 2 system. It is more practical than portable fire extinguishers because users simply have to move the hose to the hazard. This equipment can be used on delicate or critical hazards which require a clean extinguishing agent to extinguish or control the fire. The system is installed in the room itself and is ready to be used quickly and easily at the first sign of fire. The capability of a stationary unit with two 67-litre bottles is equivalent to 20 5-kg hand extinguishers. Release with this mechanism is carried out manually by a person at the hazard. It is very easy to use and requires very little effort. With very little basic training, it can be used safely.

EXTINGUISHING EQUIPMENT CYLINDERS For extinguishing agent storage, 40.2, 67 or 80-litre cylinders are available. These cylinders are installed with fastening hardware in the very enclosure of the hazard to be protected. They are designed for a working pressure of 140 bar at 50 C and a test pressure of 250 bar. The cylinders are equipped with RGS-MAM-11/1 valves with burst disc and manual release (only the pilot cylinder). The assembly also includes: HOSE REEL Stationary equipment for CO 2 manual extinguishing features a high-pressure reel with a wall bracket. Exterior elements are made of steel and interior elements of brass. It comes with a flexible hose (15 to 50 metres) rated at a test pressure of 420 bar. The assembly also includes a pistol or nozzle with retaining trigger and local application horn, which ensures optimal agent discharge. Discharge manifold (of the appropriate diameter) with coupling. 1/2 FH-15CO discharge hose 1/4 FH-6PO flexible discharge hoses (only in the case of pneumatic actuation) 1/2 VALAN-15CO check valves cylinders can be wall-mounted or mounted on a cart when mobile protection is required. Odorizer This safety feature gives a strong odour to the CO 2 allowing early detection of the presence of this gas to prevent accidents.

CONTINUOUS WEIGHING It is advisable to have continuous weighing on all CO 2 systems. These allow controlling cylinders load at all times, issuing an alert in the event of leakage, which may otherwise go unnoticed, cause great potential danger and render the equipment unusable. These operate autonomously or mechanically, with continuous monitoring. It is very reliable and has been approved by VdS, UL and FM. Visual checking is very simple, and it also features an adjustable alarm mechanism for the control panel that warns when the bottle loses between 5% and 10% by mass of the gas fill. THE AGENT Carbon dioxide (CO 2 ) is a colourless, odourless, noncombustible, non-corrosive and clean gas since it leaves no residue after discharge. It does not conduct electricity and can be used to fight fires where there is live electrical equipment. It is 1.5 times heavier than air. Being a pressurized gas, it can penetrate and spread to all areas of the fire area. It is easily liquefied by compression and cooling for storage, thus providing its own pressure. Discharge occurs in the form of gas or a finely divided solid called snow or dry ice. PHYSICAL CHARACTERISTICS CHEMICAL NAME CARBON DIOXIDE CHEMICAL FORMULA CO 2 MOLECULAR WEIGHT 44.01 LIQUID DENSITY AT 20 C 777 Kg/m 3 CRITICAL TEMPERATURE 31 ºC CRITICAL PRESSURE VAPOUR PRESSURE AT 20 ºC MAXIMUM FILL DENSITY 73.82 bar 57.1 bar 0.75 kg/l RELATIVE DENSITY VS. AIR 1.5 OZONE DEPLETION POTENTIAL 0 POTENTIAL GREENHOUSE EFFECT 1 SHUT-OFF VALVE WITH ELECTRIC SIGNAL Increases extinguishing system safety by preventing accidental extinguishing agent discharge when appropriate.

1, 2, 3, EXTINGUISHMENT The immediate actuation in the event of a fire is essential to prevent further damage. SIEX-CO 2 TM Fixed Stations are designed to respond as quickly as possible. The equipment is configured to be easily activated by staff, which is safe for both people who are in the room and protected equipment. Operation is very simple, similar to an ordinary hose station: 1 The gas cylinder valves are opened and the pistol is held by its retaining trigger 2 The hose is unwound as much as necessary to reach the fire 3 The pistol is pointed at the base of the fire and CO 2 is discharged by pulling the trigger APLICATIONS

BENEFITS Safe for equipment Its chemical composition does not react with electrical or electronic components, so there is no risk of corrosion and thus damage is prevented to equipment near the fire. Its clean discharge leaves no residue. Easy to use This system is characterized by its simplicity of use, which is essential when it comes to providing the most rapid and effective action. Easy to refill Using CO 2 as an extinguishing agent is very advantageous, since refills can be made anywhere in the world, at very low cost and without brand restrictions. Compact, rugged equipment The equipment can be placed anywhere. It takes up little space and at the same time covers a large hazard area. The components are designed to withstand the harshest working conditions, ensuring effective operation. Environmentally friendly system Since it uses a gas which is present in the atmosphere, it does not harm the environment. It is harmless to the ozone layer, currently a much needed and highly valued feature.

SIEX C. Merindad de Montija nº 6 P.I. Villalonquéjar 09001 Burgos (SPAIN) TLFNO: +34 947 28 11 08 WEB: WWW.SIEX2001.COM SIEX is a registered trademark. The information provided in this document is for information purposes only. Technical information must be used for the installation of all SIEX systems. SIEX assumes no liability for any use that third parties may make of this information. SIEX reserves the right to make any change in both the capabilities and features of its equipment.