environmental climate control equipment & solutions AQUACOOL Water-to-water heat pump with passive energy recovery

Similar documents
ENVIRONMENTAL CLIMATE CONTROL EQUIPMENT & SOLUTIONS AQUACOOL. Water-to-water heat pump with passive energy recovery.

ENVIRONMENTAL CLIMATE CONTROL EQUIPMENT & SOLUTIONS PACARE HPE+ Double flow vertical heat pump with recovery wheel.

Comfort. savings. and energy. A different climate Environmental control solutions

ULTI+ ENVIRONMENTAL CLIMATE CONTROL EQUIPMENT & SOLUTIONS

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Technical instructions

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

VEXTRA. acoustic comfort Saves up to. 40% floor space. Use. Range. Description. Drycoolers. Slim design and. Capacity up to kw.

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

HT V2 HT Split

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

GeoCIAT Modular. Components. Heat pump Heating only, Glycol/water mix/water. Refrigerant and hydraulic module diagram. HomeConnect control.

LEP kw. Indoor monobloc water-water unit. Total heat recovery multi-purpose units LEP PLUS

WZH Ground source heat pumps

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

DYNACIAT LG. Use. Range. Water chillers Heat pump. DYNACIAT LGN series. DYNACIAT LG series. Hydraulic module

LZA High efficiency air to water heat pumps with HP compressor

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

LZT High efficiency air to water heat pumps with E.V.I. compressors

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

Компрессорно-конденсаторные агрегаты. Chiller. AQH DCI 20 to 30. Air Cooled Water Inverter Heat Pump Engineering Data Manual. 20 to 30 kw.

ECOCIAT. Domestic hot water heat recovery unit. Use. Range

Rotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar.

High temperature air-to-water heat pumps

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

WDH WDH. Ground source heat pumps OTHER VERSIONS ACCESSORIES

CRIMSON & CRIMSON MAX

30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG +

NRP MULTIPURPOSE HEAT PUMPS 2 AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

Compact and silent Scroll compressors All-season operation

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

WHA WHA. Ground source heat pumps OTHER VERSIONS ACCESSORIES

The refrigerant circuit was studied in detail. Each step is verified, ensuring that each unit is perfectly leak-tight.

Modular Air-cooled Chillers

FLATAIR. E r P APPLICATION GUIDE kw HORIZONTAL PACKAGED AIR CONDITIONER. Cooling capacity : 6-34 kw. Heating capacity : 6-29 kw

OPERA MORE. Use. Range. Drycoolers Air-cooled condensers. for LESS. Capacity: up to 1100 kw. Water misting. Free cooling

AQUASNAP JUNIOR 30RHV

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

New rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1. Extensive option package included in all models. ErP. years warranty. compliant 2018

AQUACIAT LD ILD. Use. Range. Water chillers Heat pump. AQUACIAT LD series. AQUACIAT ILD series. Heat recovery. Cooling only. Cooling and heating

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

30HXC - 50 HZ. Water-Cooled Screw Compressor Liquid Chillers. Nominal cooling capacity kw

Water chillers water/water type SIGMA Technical information manual

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

v SELECTION GUIDELINES

DEHUMIDIFIERS FOR SWIMMING POOL. International. ET INTERNATIONAL S.r.l. Via Circonvallazione Est, 32/R Castelfranco Veneto - TREVISO - ITALY

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

NEOSYS. AIR TO WATER LIQUID CHILLER kw. AIR TO WATER HEAT PUMP kw. lennoxemea.com

Rotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

ERACS.C-N Higher efficiency air-cooled screw pump

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

Construction details: Structure and base in hot dip galvanised sheet steel with epoxy pain finish (RAL 9002)

DRYPACK. Protecting installations Energy optimisation. Operating principle. Description. Biogas dehumidification system. Improved profitability.

QTS SELECTION TECHNICAL BOOKLET

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Technical instructions

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

38RBS Air-Cooled Condensing Units. product selection data. commercial and industrial applications. compact design.

RMA AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

30GX - 50 Hz. Air-Cooled Screw Compressor Liquid Chillers GLOBAL CHILLER. Nominal cooling capacity kw

Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

CONDENCIAT CD. Condensing units. Quiet operation Low speed fans All year round operation USE. Cooling capacity : 25 to 165 kw.

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

NECS-N. Climaveneta Technical Bulletin. Reversible unit, air source for outdoor installation. 0202T T kw

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

Neosys Product catalogue

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module. Nominal cooling capacity kw. Easy and fast installation.

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

LZT High efficiency air to water heat pumps with E.V.I. compressors

Transcription:

environmental climate control equipment & solutions AQUACOOL Water-to-water heat pump with passive energy recovery made in France www.ett.fr

energie transfert thermique c o n t e n t s General description... 04 Operating principle... 05 Unit description... 06 Control description... 07 Main options... 07 Technical features Type 102-103 - 106-108... 08 Dimensions and connections Type 102-103 - 106-108... 09 Aquacool selection diagram Selection diagram... 10 Example... 10 3

General description The ETT packaged unit is delivered ready to operate. Its full aluminium structure (frame & casing) ensures an excellent corrosion protection (20-year anti-corrosion guarantee). The ETT unit can be installed either on a rooftop or at ground level. ECODESIGN involves DECONSTRUCTION: ETT units are 98% recyclable (re-use and recycling rates based on EFFI+ 220). Our technical choices have several impacts on the environment Legal and regulatory framework: - In accordance with Directive 2008/98/EC directive on waste, clause 26: "The polluter-pays principle is a guiding principle at European and international levels. The waste producer and the waste holder should manage the waste in a way that guarantees a high level of protection of the environment and human health. ", ETT is a member of "Eco-systèmes Pro". - In accordance with articles 5.3, 5.4 and 11 of Regulation (EC) No 303/2008, ETT holds a certificate of capability to handle refrigerants (no. 637). Aluminium: a good choice for the planet! - Aluminium is endlessly 100% recyclable. - Recycling covers over 30% of aluminium needs. Low polluting ETT manufacturing process: - Selective sorting, waste recovery, 60% of waste is recycled. - No paint on casings, no use of solvent. - ISO 14001 Certification (Environmental Management System). Consumables: efficient waste management: - Filtration: ETT units include "ecodesigned" air filters (selective sorting: frame - grille - media) We placed ease of operation at the heart of our units design: The separate technical section facilitates service and control of the unit and allows measurement and adjustment during operation. The BEST controller is specifically designed for this application. It allows great flexibility, thus optimum performance of the ETT unit through a user-friendly interface, be it local or remote (with remote display, PC or BMS). All units are checked and inspected at the factory prior to shipment, a control certificate is issued for each unit. ETT Quality organisation is certified ISO 9001:2008 (AFNOR Certificate no.1994/2016f). Moreover, each unit is delivered with an EC standard certificate of conformity and complies with the standards listed below: Machinery Directive 2006/42/EC - Operator's safety Low Voltage Directive 2006/95/EC - Electricity EMC Directive 2004/108/EC - Electromagnetic Compatibility 2009/142/EC Directive - Gas Appliances EN 1886 - Ventilation for buildings Air Handling Units Mechanical performance EN 60204-1 - Safety of machinery Electrical equipment of machines 100 % Aluminium recyclable 20-year guarantee against corrosion 4

Operating principle To complement the DESHU and OCTO+ ranges dedicated to air treatment, the AQUACOOL range is designed for pool water heating using energy recovery on waste water. The AQUACOOL system combines passive energy recovery with a spiral plate heat exchanger and a heat pump. The association of those two energy-efficient systems allows significant energy savings on pool heating. The spiral plate heat exchanger allows static recovery. Then, thanks to the heat pump, heat is recovered on waste water through the evaporator and transferred to tap water through the condenser. Exchangers on the waste water circuit are equipped with removable covers fixed with clamps which provide easy access to interior heat transfer surfaces. The evaporator and the heat exchanger are located close to the unit large access doors for easy maintenance. The unit operates as a heat pump: > source: waste water, grey water, recovery on foot baths and pools > treated fluid: tap water The following operating modes are available: > Static recovery with the heat exchanger > Static recovery with the heat exchanger + heating with the heat pump Applications: swimming pools, aquatic centres, etc. For other applications, please contact ETT Tel. +33 (0)2 98 48 14 22 Schematic diagram: TS3 SORTIE EAU DE VILLE TAP WATER (VERS OUTLET RENOUVELLEMENT (TO POOL EAU WATER DE PISCINE) RENEWAL) FOOT BATHS EAUX USEES WASTE PEDILUVE WATER + WATER + DEBIT FOR FUITE RECIRCULATION BASSINS R410A R410A EVAPORATOR TS5 TS4 RECUPERATOR B TS2 TS1 CONDENSER A R410A R410A TAP EAU WATER DE VILLE WASTE REJET WATER EAUX USEES DISCHARGE C TS6 TAP CIRCUIT WATER EAU CIRCUIT DE VILLE WASTE CIRCUIT WATER EAUX CIRCUIT USEES R410A Circuit refrigeration frigorifique circuit R410A TS1 Tap T Retour water inlet eau T de ville TS4 Waste T Retour water eaux inlet usées T TS2 Tap T Intermédiaire water intermediate eau de T ville TS5 Waste T Intermédiaire water intermediate eaux usées T TS3 Tap T Départ water outlet eau de T ville TS6 Waste T Départ water eaux outlet usées T Tap water is first preheated through the water-to-water heat exchanger (B). Then it flows through the condenser (A) where it receives heat recovered on waste water by the evaporator (C). p! Due to exchangers design (316L stainless steel), the AQUACOOL system is intended for chlorinated fresh water applications only. It is not compatible with salted water loops or salt water chlorinator systems. For swimming pools applications, it is recommended to protect the waste water circuit using a sand filter. It is recommended to install a bypass system on both circuits in case of complete maintenance operations. Stop and control valves are available as options. 5

Unit description The ETT packaged unit comprises 3 different sections: 1 The hydraulic section with large access doors for easy maintenance. 2 The refrigeration section. 3 The electrical section including the electrical board and connections. Aluminium frame and casing: Rigid, compact and lightweight vertical packaged unit, perfectly weather-resistant, with a 20-year anti corrosion guarantee on casing. Watertight floor with drainage outlets towards the border of the unit and connected to rubber siphons. Aluminium vertical panels and roof, mounted on aluminium frame. Access through large removable panels. Panels are closed with square locks. Doors tightness is ensured by flexible gasket under compression, providing an ideal elasticity day after day (French standard NF EN 1886). Hydraulic assembly: Water-to-water spiral plate heat exchanger, made of 316L stainless steel, for static heat recovery. The exchanger can be accessed for cleaning through external trap doors fixed with clamps. CPVC piping for tap water and waste water circuits, with accessories (air vents, thermowells, etc.) Analogue flow meters on tap water and waste water circuits with treated flow rate measurement on the controller. Removable filters, 500 µm efficiency on tap water and waste water circuits. Analogue pressure transmitter for fouling detection on the evaporator and on the heat exchanger. Thermodynamic assembly: Refrigeration circuits compliant with European directive on pressure equipments (PED 97/23/EC). R410A refrigerant. 316 L stainless steel spiral plate evaporator. The exchanger can be accessed through external trap doors fixed with clamps for cleaning. 316 L stainless steel brazed plate condenser. Anti-acid filter drier. HP and LP switches. 6

Control description Electrical assembly: Electrical board compliant with European standards EN 15-100 and EN 60204-01, including the following: ü ETT controller ü Power switch with lockable external handle for full load cut-off ü 400-230-24 volts transformer for regulation and control circuits ü Faults synthesis with pending dry contact on terminal ü Numbered terminal blocks with disconnecting terminals for remote controls and transfers ü Internal wiring numbered at both ends using numbered ferrules ü Ik3 breaking capacity, basis 10 KA. ü All components protected by circuit breakers ü Remote display on the front of the unit Control assembly: CTN type temperature probes. Their accuracy and liability have been tested and validated at the factory and on site. BEST-type controller (Building Energy Saving Technology) especially developed by ETT for this range of units. Programs are updated annually in order to add functions requested for some applications and to optimise units electricity consumption. The microprocessor, memory and controllers size are adapted to the chosen applications and options by integrating a program set-up in the factory. The controller is in a plastic box which guarantees a high mechanical protection and reduces electrostatic shocks threats. Among other functions, the controller includes: ü On/Off through the customer pump operation command contact. ü On/Off according to programmed schedule (2 time slots per day). ü Fault synthesis with dry contact for transfer on customer system. ü Security management (HP, LP, fouling, etc.) and faults management. ü Operating time counting for unit and compressor. ü Unit capacity and efficiency display(if the Energy meter option is selected). ü RS 485 communication as standard. Main options Acoustics Compressor sound jacket Hydraulics Low water pressure switch on tap water circuit TA valve on tap water circuit Stop valves on tap water and waste water circuits Refrigeration HP and LP pressure gauges Electricity Total electrical energy metering according to 2002/91/EC Soft starter (compressor current soft starter) Control ETT MEDIACOM, internet communication with ADSL or 3G MODBUS IP, LONWORKS or BACNET IP communication 7

Technical features Type 102-103 - 106-108 Name Unit 102 103 106 108 Waste water/tap water rated flow rate L/h 800 1500 2500 3500 Min. flow rate L/h 400 1000 2000 3000 Max. flow rate L/h 1000 2000 3000 4000 Specifications Static heating capacity (1) kw 9.8 17.9 36.4 49.7 Thermodynamic heating capacity (1) kw 8.2 13.2 19.6 26.7 Total heating capacity (1) kw 18.0 31.1 56.0 76.4 Power input (1) kw 1.2 1.7 3.0 3.9 Overall COP (1) kw/kw 15.3 18.4 18.7 19.4 ELECTRICAL CONNECTION Total installed electrical power kw 3.6 4.8 7.0 9.3 Rated current A 6.5 8.5 12.1 16.3 Starting current A 30 48 66 103 Outside sound power level db(a) 55 57 60 61 Resulting outside sound pressure at 1 m reference 2x10-5 in free field db(a) 47 49 52 53 Unit weight with water kg 372 382 431 439 General Tap water circuit pressure drop kpa 33 57 134 214 Waste water circuit pressure drop kpa 5 17 42 66 Connections mm Ø40 CPVC pipe ends to be glued Dimensions (L W H) mm 1500 x 785 x 1800 Minimum tap water/waste water inlet temperature for minimum flow rate operation (2) C/ C 6 / 25 (1) Heating capacity for 28 C waste water inlet temperature and +10 C tap water inlet temperature. (2) For operation with thermodynamics. 8

Dimensions and connections Type 102-103 - 106-108 Front view: Top view: TAP WATER WASTE WATER Side view: (hydraulic connection) Side view: (electrical and refrigeration section) A Access Power supply Provide 100 mm clearance (minimum) for side ventilation. Length Width Height Casing dimensions 1500 mm 785 mm 1800 mm Transport overall dimensions 1560 mm 800 mm 1800 mm Connections Ø40 CPVC pipe ends to be glued 9

Aquacool selection diagram Selection diagram: 90,0 85,0 80,0 75,0 70,0 Total recovery capacity (kw) Puissance de récupération Totale (kw) 65,0 3 60,0 55,0 2 50,0 45,0 40,0 35,0 30,0 1 25,0 20,0 15,0 10,0 5,0 0,0 0,0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 4,0 Tap water/waste water flow rates (m 3 /h) Débits Eau de ville/eaux usées (m3/h) Aquacool 102: temperature: + 8 C Aquacool 103: temperature: + 8 C Aquacool 106: temperature: + 8 C Aquacool 108: temperature: + 8 C temperature: + 10 C temperature: + 10 C temperature: + 10 C temperature: + 10 C Select the unit based on tap water/waste water flow rate (1). Read the total recovery capacity indication for each tap water inlet temperature: + 10 C (2) and + 8 C (3). Example: For a flow rate of 2.5 m 3 /h (1), the suitable unit is the Aquacool 106. For + 10 C tap water inlet temperature, total recovery capacity is 56 Kw (2). For + 8 C tap water inlet temperature, total recovery capacity is 59 Kw (3). 10

Reference: ETT - Route de Brest - BP26 29830 Ploudalmézeau - France Tel: +33 (0)2 98 48 14 22 Fax: +33 (0)2 98 48 09 12 Export Contact: +33 (0)2 98 48 00 70 Direct ETT Services: +33 (0) 2 98 48 02 22 www.ett.fr Design: ETT - Document printed by an environmentally friendly printer using vegetable based ink on PEFC paper created from sustainably-managed forest.