False Sense of Security???

Similar documents
ADDENDUM #1 ITB# Fire Protection Maintenance Services Responses to Clarification Questions 10/06/2015

Service Requirements SEMI- ANNUAL ANNUALLY OTHER REF. REQUIREMENT

MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS

2-SUPPRESSION REQUIREMENTS - CODE REQUIRED INSPECTIONS TEST Page 1 of 7

Quick Guide for Fire Sprinkler Inspection Requirements Key Deficiencies with NFPA References NFPA & NFPA 13/

Owner/Operator Guide for Successful Sprinkler and Fire Pump Systems

EXHIBIT D ATTACHMENT G - UNIT PRICING DMS-14/15-039B - SIMPLEXGRINNELL, LP FIRE SPRINKLER SYSTEM INSPECTIONS YEARS 1-5

Global Property. SEMIANNUAL FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

NFPA CODE TESTING & INSPECTION. Requirements & Recommendations for. Licensed Florida Hospitals, Ambulatory Surgery Centers,

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment

Global Property. QUARTERLY FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

Winnipeg Fire Department Fire Prevention Branch

Inspection of Fire Sprinkler Systems. NFPA 25, Inspection, Testing & Maintenance of Water Based Fire Protection Systems

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry Plan Review

Annual Report of Inspection, Testing & Maintenance of Automatic Sprinkler System

Manufacturing safety solutions

APPENDIX H (DESIGN SUBMISSION CRITERIA)

CHAPTER 61G15-32 RESPONSIBILITY RULES OF PROFESSIONAL ENGINEERS CONCERNING THE DESIGN OF FIRE PROTECTION SYSTEMS

Inspection and Testing of Water-Based Systems

CONSTRUCTION REQUIREMENTS

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

Design & Construction Standards, Revised January

Division 21: FIRE SUPRESSION WET-PIPE SPRINKLER PROTECTION SYSTEM. The Academy Sept Table of Contents 1 Division 21

HOW COMMERCIAL FIRE PROTECTION SPRINKLER SYSTEMS REALLY OPERATE

9/15/ Cantara Lane Vista, CA (760)

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE

UBC Technical Guidelines Section Edition Fire Protection General Requirements Page 1 of 6

Life Safety Code NFPA 10 NFPA 13 NFPA 25 NFPA 72 NFPA 90A NFPA 110 NFPA 99 THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #7

Revision May All designs must be submitted to FM Global for review and approval prior to issuing such for bids.

A. Section includes wet-pipe sprinkler system, system design, installation, and certification.

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

New Construction Fire Inspection Process

PLAN REVIEW CHECKLIST

Slide 2 NFPA 25: 2017

DIVISION 21 FIRE SUPPRESSION

FIRE SAFETY SYSTEMS MAINTENANCE INFORMATION

Inspection, testing, and maintenance (ITM) Fixed fire protection and detection July 2016

Oxnard Fire Department 360 W. Second Street Oxnard, CA (805) Fax (805)

SECTION SPRINKLER SYSTEMS

Self Inspection Program

D. The work addressed in this section consists of a fire protection system, which may include coordination with one or more of the following:

Module 3. Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements

B. Section Identification for Fire Suppression Piping and Equipment.

Chapter 4: Fire Protection Systems

SECTION WET PIPE FIRE PROTECTION SPRINKLER SYSTEM

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

System Test Report CLEAN AGENT

SECTION WET-PIPE SPRINKLER SYSTEMS

Box-in-Box Cold Storage Fire Protection Options

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040

Gas Station & C Store SECTION CWM Job No

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

DIVISION 21 FIRE SUPPRESSION FIRE SUPRESSION

A. This section includes design and performance information for fire protection and suppression systems.

Fire Sprinkler Plan Submittal Form

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

Advanced Integrated Fire Protection Systems TOTALPAC 2. Owner's Operation and Maintenance Manual FIRECYCLE III. September 2009 FM-086G-0-5E

Table OUT OF SERVICE. Building Fire Video 1/15/ Inspection, testing and maintenance. Standards Further Referenced by FCNYS

Deluge/Preaction Systems Annotated Instructor s Guide

Scope of Section 2. AS vs. Application Issues. Schedules & Log- Contents. Books

Deluge/Preaction Systems Annotated Instructor s Guide

TECHNICAL DATA OBSOLETE

WET AUTOMATIC FIRE SPRINKLER SYSTEMS

SECTION WET AUTOMATIC FIRE SPRINKLER SYSTEMS

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

TECHNICAL DATA 1. SYSTEM DESCRIPTION 2. SYSTEM OPERATION 3. INSTALLATION. Page 1 of 5

DEPARTMENTAL GUIDELINES CHAPTER 6 TACTICAL OPERATIONS

UNIVERSITY OF MISSOURI Fire Protection System Design 2016 Q1

Sheetz Inc. Fire Protection Service Guidelines

PROTECTING FIRE SPRINKLER SYSTEM PIPES FROM FREEZING IN CHAPTER FACILITIES

Model: 400E-5M. Bermad Hydraulically Controlled Anti-Columning Deluge Valve, with Easylock Manual Reset. Installation Operation Maintenance

Sprinkler System Installer

Corrosion in Fire Sprinkler Systems Increasing Your Liability, Increasing Your Costs, and Shortening System Life

B. The sprinkler system shall be designed to meet the more stringent of the requirements of NFPA 13 and FM Global requirements.

SECTION WET-PIPE SPRINKLER SYSTEMS

LIFE SAFETY TRAINING Nebraska Health Care Association Chris Moran November 1, 2017

Fire Sprinkler Submittal Requirements and Acceptance Testing

MAINTENANCE AND INPSECTION OF FIRE PROTECTION SYSTEMS AND APPLIANCES

TOTALPAC2 Integrated Fire Protection System

Fire Protection System Contractors and Systems. Submission of the Application for a Water-Based Fire Protection Inspector

UC Santa Cruz Campus Design Guide. Includes the following sections: None DESIGN REQUIREMENTS

Skilled Healthcare Documentation Requirements Life Safety and Fire Protection

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

NFPA 25 and the Influence of Liability

SECTION WET FIRE SPRINKLER SYSTEMS

Fire Safety Plan (Single-Stage Fire Alarm System):

Fire Safety Plan (Single-Stage Fire Alarm System) (Small Establishment):

Environmental Health & Safety

FIVE YEAR AUTOMATIC FIRE EXTINGUISHING SYSTEMS CERTIFICATION REPORT

SECTION FIRE-SUPPRESSION STANDPIPES

BERMAD Fire Protection

SECTION FIRE PROTECTION. A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section

GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE

SECTION (13900) - FIRE SUPPRESSION SYSTEMS

SECTION DRY-PIPE SPRINKLER SYSTEMS

FIRE SAFETY PLAN. Building Name. Address. Prepared By. Date Prepared. Page 1 of 36

Other EC and LS documents may be requested by surveyors, as needed, throughout the survey.

Transcription:

IS YOUR SPRINKLER SYSTEM GIVING YOU A FALSE SENSE OF SECURITY? Best Practices in Fire Safety An ASSE Virtual Symposium March 1 & 2, 2011 Walter S. Beattie CSP, CFPS, CSHM False Sense of Security??? Fire protection systems are passive in nature. They are designed for an occupancy They do not operate on a daily basis How do you know they will work if needed? You are ultimately responsible Regular inspection Regular testing Regular maintenance 1

Are You Checking sprinkler control valves? Performing waterflow alarm tests? Running your diesel fire pump weekly or electric monthly? Performing annual fire pump tests? Flowing your hydrants? Flushing the underground mains? Inspecting your fire water tanks? Testing the antifreeze? Handling your impairments properly? Where do I find requirements? NFPA 25 Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems Insurance carrier Fire department Corporate standards NFPA 25 establishes the MINIMUM requirements Inspection A visual examination of a system to verify that it appears to be in operating condition i and dis free of physical ldamage. Testing a physical trying or operation of a system, or part of a system to ensure or prove that it is functioning properly, as intended, or to an acceptable standard of operation. Maintenance The work performed to repair and/or maintain equipment in operable condition. 2

NFPA 25 Covers: Sprinkler Systems Standpipe and Hose Systems Pi Private Fire Service Mains Fire Pumps Water Storage Tanks Water Spray Fixed Systems Foam-Water Sprinkler Systems Water Mist Systems Vl Valves, Valve Vl Components, and Trim Obstruction Investigation Impairments Setting up an inspection program Documented (In writing!!!!) In-house Contracted In-house Inspections & Contracted testing & Maintenance 3

Records, plans, and calculations Original as-built installation drawings Hydraulic calculations Original acceptance test records Component data sheets Letters regarding the review and acceptance of the system Before you test Notify the alarm supervisory service Notify department heads Notify operators of critical equipment Make a general plant announcement Others as needed Wet Pipe Sprinkler Systems Weekly Checks 4

Are the Valves Open? Unsupervised - Weekly Are the Valves Open? Are the Valves Open? 5

Are the Valves Open? Are the Valves Open? 6

Check the Gauges Is equipment accessible? 7

Has the hazard increased? Wet Pipe Sprinkler Systems Monthly Checks Weekly Checks Supervised Valves Gauges Gauges Obvious Damage Monthly 8

9

10

11

Wet Pipe Sprinkler Systems Quarterly Checks Quarterly Inspections & Tests Wet Pipe Sprinklers Valve Supervisory Devices Supervisory Signal Devices Hydraulic Nameplate Hydraulic Nameplate Fire Department Connections Test Waterflow Devices Mechanical such as Water Motor Gong Weekly & Monthly Checks 12

Fire Department Connection 13

Valve Tamper Switch Semi Annual Wet Pipe Sprinklers Weekly Checks Monthly Checks Quarterly Checks Test Valve Supervisory Devices Annual Wet Pipe Sprinklers Hangers Sprinklers Pipe & Fittings Pipe & Fittings Spare Sprinklers Main Drain Test Antifreeze test 14

SoniTech NDT - www.sonitechndt.com Used with Permission 15

Obstructions 5 Year + Wet Pipe Sprinklers Gauges 5 Year + Wet Pipe Sprinklers 16

Testing of Sprinklers Submit to Recognized Testing Laboratory Fast Response elements 20 years & 10 year interval Sprinklers 50 Years 10 year interval Sprinklers 75 Years 5 year interval Extra high temp - 325 F+ every five years Dry sprinklers test 10 year intervals Harsh Environment 5 Years + 5 Years Heads prior to 1920 - REPLACE Dry Pipe Sprinkler Systems 17

Dry Pipe Valve Checks Wet Pipe checks Air pressure Weekly Compare riser air gauge to compressor gauge Compare riser air gauge to compressor gauge Water Column Test Ice buildup 18

Dry Pipe System Rust & Corrosion SoniTech NDT - www.sonitechndt.com Used with Permission Dry Pipe System Ice Plugs SoniTech NDT - www.sonitechndt.com Used with Permission 19

Dry Pipe System Ice Plugs SoniTech NDT - www.sonitechndt.com Used with Permission Standpipes & Hoses Inspect Control Valves Weekly/Monthly Pressure Regulating Devices Quarterly Pressure Regulating Devices Quarterly Piping, Connections, Cabinet, Hose Annually Tests Hose Storage Device Annually Hose, Pressure Control/Reducing Valves, Hydrostatic Test, Flow Test 5 Years 20

These valves are designed to reduce hose pressure from high pressure pumps. One Meridian Plaza Philadelphia, PA February 23, 1991 Where pressure reducing valves were not properly set 3 Firefighters Died Private Fire Service Mains Check Valves Weekly/Monthly Hydrants Annually and after each operation Hose Houses Quarterly Monitor Nozzles Semiannually Piping Annually Testing 5 Years 21

22

Monitor Nozzle Interior Corrosion SoniTech NDT - www.sonitechndt.com Used with Permission 23

Interior Corrosion SoniTech NDT - www.sonitechndt.com Used with Permission Microbiological Induced Corrosion (MIC) Microbiological Induced Corrosion (MIC) 24

Fire Pumps 25

Fire Pumps Pump House Checks Temperature Louvers Weekly Running Valves open Start on Pressure Drop Start with both batteries Check batteries Check for leaks Fire Pumps - Electric Electrical Systems Power lights on Transfer/Isolating switches Phase reversal lights Oil l l i i l i h l Oil level in vertical motor sight glass Electrical components Run Monthly at least 10 minutes (change 2011) Constantly attended I advise to run weekly for reliability Packings dripping Bearing not too hot 26

Fire Pumps - Diesel Fluid levels Batteries Full Corrosion??? Controller switches & Setting Controller switches & Setting Fuel Tank level not less than 2/3 full Run Weekly at least 30 minutes Constantly attended Packings dripping Bearing not too hot 27

28

Fire Pump Annual Test 29

30

Water Storage Tanks 31

32

Water Storage Tanks Inspect Water Level (alarm) Inspect Heating System Inspect Water Temperature (alarm) Exterior Inspection Corrosion Ice Build-up Erosion for fabric tanks Tank Fill Valves 5 Year Inspection & Maintenance Tank Level Indicators Covering the vent valve during tank painting is fairly standard practice; unfortunately leaving it covered when drawing out of the tank is very nonstandard practice. Tank Collapse 33

Water Spray Fixed Systems Water Spray Fixed Systems Check Valves & Water Supply Detection Systems (NFPA 72) Inspect Hangers, Supports, Fittings, Heads, & Components Quarterly Alarms Annual Operational Tests 34

Backflow Preventer Backflow Preventer 35

Impairments 36

Impairments Have a Good Impairment Program Follow Your Impairment Program Inform Management, Fire Department, Alarm Company, Insurance Carrier Discontinue Hazardous Operations No Hot Work or Smoking Work Continuously Impairment of Water Supply to a Fire Pump Photo courtesy of Robert Woodard. Used with permission. Excess Pressure Pumps 37

Types of Sprinkler Heads Standard Pendant Standard Upright 38

Types of Sprinkler Heads In-Rack Grinnell 165F K=5.6 Duraspeed with watershield In-Rack sprinkler Installed Types of Sprinkler Heads K17-231 Special Head Central (Tyco) Large Drop Viking LD 286F Types of Sprinkler Heads ESFR Pendant ASCOA K-1 K-14 155F ESFR - Upright Viking VK-520 K-14 165F 39

Types of Sprinkler Heads Dry Sprinkler Fusible Link Releases Sleeve Moves up Water Goes Around Mechanism Water Discharge Types of Sprinkler Heads Releasing head for deluge systems 40