WALLACE & TIERNAN CONTROLLERS & ANALYSERS CHEMTRIM DISINFECTION CONTROLLER PRODUCT SHEET

Similar documents
Wallace & Tiernan Controllers & Analysers ChemTrim Disinfection Controller

Water Technologies. V600 Disinfection Controller

V600 DISINFECTION CONTROLLER

REACTIon TANks. Pump control-telemetry Unit

Wallace & Tiernan Liquid Feed System LVN-2000 Liquid V-Notch

Wallace & Tiernan Gas Feed Systems V2000 Chlorinator

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Capital Controls SERIES 70CV3000 CHLOROMATIC VALVE

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.


SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting

I/A Series 716C 1/16 DIN Temperature Controller

Two-Channel Gas Controller

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

PT9420 (Extended Range)

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training

Carbon Monoxide Transmitter

EC3-X33 Stand-alone Superheat Controller Technical Data

1.7. Insulation fault evaluators EDS460/490 EDS461/491

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

PRODUCT LINE. Highest Quality, Best Service

K 100 (W) DES. Disinfectant measurement. Applications. Description. Intuitive and simple menu Safety by password function. Disinfection.

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

1.7. Insulation fault evaluators EDS460/490 EDS461/491

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

PTE0705 Electric Fence Monitor

TEMPERATURE CONTROLLER (STANDARD MODEL)

Tri-Stack Smart System

Oxygen (O2) Single-Point Gas Detection System

General Routing Interface

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Cable Actuated Sensor Industrial User Scalable VDC Output

K-Controller Brochure.qxp_ Controller Brochure 2/27/17 3:03 PM Page 4 Versa IC Platform

Frequently asked questions: Intelligent Transmitter Series

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

CAPITAL CONTROLS SERIES WP70CV3 GAS FEEDERS

Insulation fault evaluator EDS460-DG

Cable Actuated Sensor Industrial User Scalable 4 20mA

OVEN INDUSTRIES, INC.

ACT2-CS Convenience Store Controller

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Nov 08 PRODUCT SPECIFICATION SHEET

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

SPM-4000-DC GUARDIAN INFINITY SPACE PRESSURIZATION MONITOR AND DUAL CONTROLLER

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

M2500 Engine Controller Installation Manual

Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA series Protocols)

Altanium Temperature Controllers

SCAN200E USER S MANUAL

SUPREMATouch. Modular Fire & Gas Detection System

Multi-Gas-Controller MGC2

Each burner shall be equipped with a Micro-Processor Based Burner Management Flame Safeguard and Parallel Positioning Control System.

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

PowerWizard Range. Digital Control Systems & Remote Communication Options.

Analog Room Pressure Monitor RPC Series

SUPREMATouch. Modular Fire & Gas Detection System

Low Temperature Zirconia Oxygen Analyzer

IGD.CO.UK

02/11/2015

HTC-915-CONT. Heat-Trace Control system

Satchwell. DC1100 Energy Controller SELF CONFIGURING OPTIMISER/COMPENSATOR WITH BOILER SEQUENCE AND HWS CONTROL FEATURES

The supplier and installer of the system should be approved by the local civil defence authority.

Corrigo E. Second generation which contains all applications and languages

The EN54 Part 2 & 4 Fire System

HIGH CAPACITY PRODUCT LINE

Natural Ventilation Controller with 24vDC drive NVC-1204

IntelliPack : 800 Series

Controller Specification Sheet

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

Natural Ventilation Controller with 24vDC drive NVC-1204

Stand Alone DYNAGARD SP Operation Manual

C910 Series. Single-point heat-tracing control system

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

02/11/2015

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

/8 DIN Level Indicator

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

End To End Optical Beam Smoke Detector. Additional Information

New Versa IC Platform

Installation Manual Tracker 221

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

MYRIAD DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL VERSION 3.7

REGARD. REGARD 4-20 AND Ex CHANNEL CARDS INSTALLATION AND OPERATING MANUAL (FOR ATEX VERSION CARDS)

Mark 25 Ultrapure Water Conductivity Analyzer

Digital Control Systems & Remote Communications Options

Transcription:

WALLACE & TIERNAN CONTROLLERS & ANALYSERS CHEMTRIM DISINFECTION CONTROLLER PRODUCT SHEET

INTRODUCTION The ChemTrim Disinfection Controller is a modern, dedicated controller incorporating the latest advanced electronics and process control application features. The unit is designed to accurately maintain the optimum chlorine residual in water by the precise regulation of the dose of chlorine or sulphur dioxide, in chlorination/ dechlorination or chloramination. It is suitable for use with gaseous chlorinators/sulphonators/ ammoniators. It can also be used for liquids using dosing pumps for commercially produced sodium hypochlorite or that derived from OSEC Hypochlorite Generation System, Sodium Bisulphite or Ammonium Sulphate solutions. The ChemTrim Disinfection Controller provides a comprehensive and unrivalled list of features for manual or automatic control of simple borehole applications through to complex treatment work applications. Key Benefits Built-in flexibility Choice of 6 control options Comprehensive list of features Simple to operate controller Variety of installation and mounting options Combined with Wallace & Tiernan ChemWeb server or Wallace & Tiernan OPC software, the system offers a wide range of remote communications options THE CHEMTRIM CONTROL SYSTEM The ChemTrim control system has been designed with consideration to the practicalities of site installation and site operation. The ChemTrim controller should ideally be located adjacent to the dosing apparatus. MOUNTING OPTIONS The ChemTrim controller can be supplied in the following options; Wall mounted plastic enclosures to IP 67 Panel mounting for use in customer's panel enclosure to IP 65 Single wall mounted steel enclosures to IP 65 CONTROL OPTIONS Choice of 6 control options A choice of control options to meet the most simple to the most demanding of applications:- 1. Manual Control Enables the operator to take full control in setting the dose rate to the required value. Controller Control Output Dosing Device(s) FLOW Figure 1. Manual Control

2. Control in Response to Flow A 0/4-20 ma or 0-10V signal from a flow transmitter is fed into the controller and the dosing equipment injects chemicals proportional to the treated water flow. An option to accept two flow signals is also available, where the sum of the two signals is used for the calculation of the dose rate. If this option is selected the ChemTrim controller will automatically detect the two flow signals and configure the flow control accordingly. Controller Flow Input Control Output Dosing Device(s) FLOW Flow Meter Figure 2a. Control in Response to Flow To Flow Input 1 on Controller To Flow Input 2 on Controller To Flow Input 1 on Controller FLOW 1 COMMON FLOW FLOW 2 2 Flow Meters (Option) Common Flow Meter (Standard) Figure 2b. Control in Response to Flow

3. Dual Feed Forward Control (ratio control) Offers the opportunity to feed an input signal from an ammonia monitor or chlorine analyser to provide a ratio adjustment to increase or decrease the chlorine dose rate. The advantage of this input signal is that it initiates an immediate response to the dosage calculation without waiting for process times. The additional use of a flow meter signal input is selectable. This mode of control is used in the treatment of river water applications where a signal from an ammonia analyser will enable the controller to respond to varying ammonia levels that may necessitate significant adjustments to the chlorine dose rate. It may also be used in rechlorination schemes, enabling the controller to take into account existing varying chlorine levels arriving at the rechlorination point. Controller Analyser Input 1 Flow Input Control Output Dosing Device(s) FLOW Analyser (Cl2 / NH3) Flow Meter Figure 3. Dual Feed Forward Control 4. Residual Control In this control mode, sample water is fed continuously to the analyser and transmitter which provides a 0/4-20 ma signal to the controller. The measured signal is compared with a pre-set residual, and any deviation from the control setpoint initiates a proportional/ integral correction to the chemical dosing device. Provides stable residual control where the quality of the water varies but the flow rate of the treated water is relatively stable. Controller Analyser 1 Control Output Dosing Device(s) FLOW Analyser (Cl 2 / ClO 2 / Deox / O 3) Figure 4. Residual Control

5. Control with Flow and Residual Control. (Compound loop) Provides stable residual control where both the water quality and flow rate are subject to variations. Controller Flow Input Analyser 1 Control Output Dosing Device(s) FLOW Flow Meter Analyser (Cl 2 / ClO 2 / Deox / O 3) Figure 5. Control with Flow and Residual Control 6. Flow and Residual Control with Setpoint Trim Provides primary control as per flow and residual control outlined above but with the added advantage of secondary control from a second analyser to compensate for any additional chlorine demand that may occur after a period of time. Typically used in applications where responsive control is required prior to the inlet to a chlorine contact tank but there may be continuing demand within the contact tank. Considerations should be given to the duration of both process loops and Evoqua Water Technologies would be pleased to offer advice in this application. Controller Analyser 2 Flow Input Analyser 1 Control Output Dosing Device(s) Contact Tank FLOW Flow Meter Analyser (Cl 2) Analyser (Cl 2 ) Figure 6. Control with Flow amd Residual Control with Setpoint Trim

CHEMTRIM SYSTEM - FEATURES The input/output connections to the ChemTrim controller are shown below:- CHOICE OF VOLTAGES 230V AC, 115V AC, 24V DC Option of terminal box to accept steel wired armoured cabling. Enclosure to IP 55 Plastic wall mounted Enclosure to IP 67 Option of wall-mounted steel enclosure suitable for steel wire armoured cabling. Enclosure to IP 65 Panel mounted option for mounting in customer s own panel Enclosure to IP 65 Panel mounted Mounting options Status display options indicating values, bar graph, graphs, text, control algorithms and dosing machine information Shown on a 240 x 64 back-lit LCD display Option of moving alarms low & high alarms in relation to varying setpoints 2 low residual alarms and 2 high residual alarms Indication of 21 alarm conditions. (The last 24 alarms are shown in the alarm history log) 9 LED display, power on/off, system fault, alarm-when any alarm activated. relay 1, 2, 3, 4, activated Relay 1, can be used for watchdog operation Normally open or closed operation. Latched with acknowledge. Unlatched or latched with reset operation. 4 alarm relays. Each with front panel status LED. All alarms are mappable Assignable 0-20mA or 4-20mA signals Flow, flow 2, flow (total), analyser 1, analyser 2, setpoint, control output, chlorine demand. (Availability depends on control system selected) 3 analogue outputs Information Data logging is fixed to 1 month of data at 2 minute intervals. Displayed on LCD screen in 8hr periods Choice of output to measure 1 of the following:- Analyser 1, Analyser 2 or Flow (total), Control output (total). Viewed as a graph or downloaded via RS232 to laptop Data logging New alarms inhibited Hardware fault CANbus error, Dosing interface fault System fault Options to select shut down or manual setting When the 4-20mA signal falls below 3.1mA Signal failure alarms Low Flow alarm or analogue signal failure Auto shutdown Download data to laptop Displays all analogue input status, control I/O status, software versions, reset setting to factory defaults Upload program into flash memory Comprehensive range of diagnostics RS232 Communications W&T Chemweb Server OPC compliant SCADA Supporting W&T protocol RS485 Input 2 mapped to shutdown or alarm inhibit Input 1 mapped to control inhibit, alarm inhibit. control inhibit and output to 0%, or 50%, or 100% 2 Digital inputs Operational features New alarms inhibited Hardware fault, CANbus error System fault

CHEMTRIM CONTROLLER Security. 2 passwords & 3 levels of access Structure menu system. Only items selected are shown when appropriate. Everything else is hidden Menu 1 for commissioning. Menu 2 for configuration. Control Mode enables quick changes to operational parameters Control in response to flow 0/4-20mA or 0-10V from flow transmitter 2 Flow meter inputs and the sum used for calculations (Auto detection -plug & play principle) Flow signals displayed as I/s or MLD, m 3 /h Dual feed forward (ratio control) 0/4-20mA input from ammonia or chlorine monitor and 0/4-20mA or 0-10V from flow transmitter Flow signal displayed as I/s or MLD, or m 3 /h Choice of control options Residual control Flow & residual control 0/4-20mA input from chlorine / chlorine dioxide, deox or ozone monitor 0/4-20mA or 0-10V from flow transmitter + 0/4-20 ma residual input signal Process time proportional to flow Flow signals displayed as I/s or MLD, or m 3 /h Residual setpoint trim Secondary control from additional 0/4-20mA analyser input signal Process time proportional to flow Flow signals displayed as I/s or MLD, or m 3 /h Manual control Choice of controlling devices Dosing pumps Gas feed - chlorinators, sulphonators, ammoniators Increase /decrease (positioner) 1k or 5k feedback potentiometer which is auto detected & configured Increase /decrease (positioner) 1k or 5k feedback potentiometer which is auto detected & configured Relay contact range of 30-122 pulses/min 0/4-20mA output signal 0/4-20mA output signal Increase / decrease + ma output control (even control on each) Gas feed systems Injector vacuum line relief System Options Liquid feed systems Dosing pump vent option Open solenoid valve and/ or boost pump to max speed Adjustable frequency and duration settings Control of injector operating water Optional water solenoid valve or booster pump

CHOICE OF OPERATIONAL FEATURES The ChemTrim controller is designed to provide continuous operation and selectable features for that added degree of security. Automatic Control Inhibit and Auto Shutdown Two Digital inputs are provided. Input 1 can be mapped to inhibit control, inhibit alarms or set control to 0%, 50% or 100%. This feature is used when residual inputs or flow measurement are unreliable for a short period of time such as during filter backwashing procedures. Digital input 2 is provided for automatic shutdown and alarm inhibit. System Fault The ChemTrim controller is designed to detect a fault in the hardware of the controller. LED Display CHEMTRIM SYSTEM CONNECTION DIAGRAMS The input/output connections to the ChemTrim controller are shown below:- Power Supply Power 115V / 230V AC or 24V DC Feedback 1k / 5k Pot. Enable Relay Analogue Inputs Flow or 0..10V Flow 2 (Option) or 0..10V Analyser 1 Analyser 2 External Setpoint Inc / Dec Relay ma Output On/Off Relay Vent Relay Fault Digital Input Volt Free Contact Dosing Machine 1 GP Digital Inputs ma Outputs GP Digital Input 1 Volt Free Contact GP Digital Input 2 Volt Free Contact ma Output 1 ma Output 2 Alarm Relay 1 Alarm Relay 2 Alarm Relay 3 Alarm Relay 4 Alarm Relays ma Output 3 RS232 Communications RS485

COMMUNICATIONS AND SECURITY User Operating and System Information The ChemTrim controller is designed to be easy to operate and a 240 x 64 LCD backlit display provides the user with access to system and process information. User Friendly Operation A user friendly menu structure is provided to enable easy and quick access to the information required. Access is via 3 soft keys. Up, down, left, right arrows and enter and escape buttons provide easy navigation to the information required. Alarm Information Provides indication of 21 alarm conditions. The last 24 alarms are shown in an alarm history log. There are 2 low residual alarms and 2 high residual alarms. The ChemTrim controller also provides a selectable option to move low and high alarm 1 in relation to varying setpoints. The Status Display Options include the display of residual values, bar graphs, trending graphs and text. Built-in Data Logging Can provide the user with one of the following selectable values to record. Analyser 1 Analyser 2 Flow (total) Control Output (total) The data logging is fixed to 1 month of data at 2 minute sampling times. The data is displayed in 8 hour periods providing the user with clearly visible information. The data may be viewed as a graph on the controller display or downloaded to a laptop via the RS232 interface. COMMUNICATIONS AND SECURITY RS232 Communications The RS232 interface enables a standard laptop computer to be connected to the ChemTrim controller. This interface may then be used to upload the main program into flash memory, or download the data logging data from the controller. It can then be imported into standard software programs such as Microsoft Excel spreadsheet software where the information can be displayed in any format. RS485 Communications An RS485 connection will allow remote access and transmission of data. When used in conjunction with the Wallace & Tiernan ChemWeb server it offers a flexible choice of remote communications via modem/ TCP IP and to OPC compliant SCADA systems using the Wallace & Tiernan OPC software. All operation and commissioning parameters will be accessible using the RS485 interface and some additional variables to give status/alarm information. Security An inbuilt security system to the ChemTrim controller is provided via 2 passwords and 3 levels of access. 1. System Password allows access to the commissioning and operational menus 2. Menu 2 Password allows access to the operational parameters only 3. Manual/Auto Parameters Open access. The 3 levels of access correspond to the 3 menu systems using the soft keys RS232 Connection to ChemTrim controller ChemTrim controller key pad

CHOICE OF SYSTEM OPTIONS A number of customer selectable options are built into the ChemTrim controller to enhance the operational efficiency of your dosing system. Injector Vacuum Line Relief (Gas feed devices) The use of remote injectors is desirable when there are long distances between the gas feed device and the injection point. It reduces the system process time, enabling quick responses to water quality or flow variations. The use of the injector vacuum line relief option is desirable to prevent excess vacuum forming that can occur in long injector vacuum lines. TECHNICAL DATA Electrical Mains Supply: (Voltage specified with order) 115V AC ±10%, 50-60Hz, 30VA 230V AC ±10%, 50-60Hz, 30VA 24V DC, 30W Fuses F1 & F2: 115V / 230V AC 1A(T), 250V, TR5 24V DC 2.5A(T), 250V, TR5 Fuses FS1 & FS2: (Steel enclosure only) All voltages - 3.15A(T), 250V, 5 x 20mm Safety: BS EN 61010 Installation category II EMC: BS EN 61326 Physical Plastic Enclosure Size: 273 x 316 x 167 (H x W x D) Weight: 5 kg Single Steel Enclosure Size: 600 x 435 x 279 (H x W x D) Weight: 19 kg Dosing Pump Vent Option Certain liquids, such as Sodium Hypochlorite, can gas lock dosing pumps at low flows. Whilst many dosing pumps can be fitted with gas venting devices, the ChemTrim controller provides that added protection against this problem with the option to boost the pump speed at an adjustable frequency and duration or to open a solenoid valve and vent the gas back to the chemical storage tank. Control of Injector Water Supply The ChemTrim disinfection controller will control the operation of a water solenoid valve or injector booster pump. Panel Mounting - Bezel Size: 210 x 280 x 25 (H x W x D) Weight: 1 kg - Base Unit Size: 273 x 316 x 115 (H x W x D) Weight: 4 kg Terminal Box Size: 200 x 300 x 120 (H x W x D Weight: 4 kg Environmental Temperature Range: Operation 0 50 C (max 90% RH, non condensing) Storage 20 70 C IP / NEMA Rating: Plastic enclosure: IP 67 / NEMA 4X Steel enclosure: IP 65 / NEMA 13 Panel mount bezel: IP 65 / NEMA 13 Terminal box: IP 55 / NEMA 12

Feedback Signals: 1KΩ or 5KΩ potentiometer (automatic detection) Not isolated RS232 Interface: Supports Wallace & Tiernan ChemWeb Server & OPC Software protocols Not isolated RS485 Interface: Supports Wallace & Tiernan ChemWeb Server & OPC Software protocols Galvanically isolated from earth to 50V Inputs/Outputs Digital Inputs: For use with volt free contacts only isolated voltage supplied by controller (15V DC nominal) Relay Outputs: Resistive rating: 5A, 250V AC, 1250VA max 5A, 220V DC, 150W max UL/CSA Rating: 5A 1/6 HP 125,250 V AC 5A 30V DC 30W max 1A 30V DC to 0.24A 125V DC Suppression with Schottky diodes Analogue Inputs: 0 20 / 4 20mA and 0 10V Input impedance 47Ω for ma signals Accuracy 0.5% full scale Galvanically isolated from earth to 50V Analogue Outputs: 0 20 / 4..20mA Accuracy 0.5% full scale Maximum load 400Ω or 1KΩ (switch selectable) Galvanically isolated from earth to 50V Feedback Signals: 1KΩ or 5KΩ potentiometer (automatic detection) Not isolated RS232 Interface: Supports Wallace & Tiernan ChemWeb Server & OPC Software protocols Not isolated RS485 Interface: Supports Wallace & Tiernan ChemWeb Server & OPC Software protocols Galvanically isolated from earth to 50V

Office 12, Dana Estate, Transfesa Road, Paddock Wood, Kent, TN12 6UT, United Kingdom +44 (0) 300 124 0500 Email: info.uk@evoqua.com www.evoqua.com W&T, Wallace & Tiernan, OSEC and ChemTrim are trademarks of Evoqua, its subsidiaries or affiliates, in some countries. Microsoft and Excel are trademarks of Microsoft Corporation. All information presented herein is believed reliable and in accordance with accepted engineering practices. Evoqua makes no warranties as to the completeness of this information. Users are responsible for evaluating individual product suitability for specific applications. Evoqua assumes no liability whatsoever for any special, indirect or consequential damages arising from the sale, resale or misuse of its products. 2017 Evoqua Water Technologies Ltd Subject to change without notice WT.040.750.000.GE.PS.0417