Fire Alarm Wiring. Circuit types, styles and limitations

Similar documents
Fire Alarm System Fundamentals

Surviving Survivability A User s Guide to Survivable Fire Alarm Circuits Larry D. Rietz, SET 23 May 2018

NFPA Changes

Multiple Input and Output Modules

Hospital Fire Alarm Systems Recurring Misapplications and Misused Requirements

Changes in NFPA

First Revision No. 158-NFPA [ Global Input ] Submitter Information Verification. Committee Statement

INSPECTION AND TESTING FORM

Fire alarm system specification for multiple tenant retail buildings

SIGA-CC1 Single Input Signal Module Installation Sheet

Fire Alarm Testing and Inspection Report

SECTION FIRE ALARM STANDARDS REVISED CONSTRUCTION STANDARD

Print Specification. Publication. Instructions. Specific requirements. General requirements

109-B Concord Drive Casselberry, FL DynaFire.com INSPECTION AND TESTING FORM PER NFPA 72. Owner s Address: Owner's Phone Number:

good things in small packages

PSN-1000 & PSN 1000(E) Installation Manual

NFPA Siemens Industry, Inc. All rights reserved. usa.siemens.com/infrastructure-cities

1.3 REFERENCE STANDARDS

NFPA 72 Code Changes vs 2013

2018 NICET Code Transition Changes

FIRE ALARM SYSTEMS & 780 CMR. Dave LeBlanc, PE, FSFPE March 17, 2015

FIRE DETECTION & ALARM SYSTEM BASICS

Unified Fire Authority - Fire Prevention Bureau

Automatic Fire Alarm Association Webinar On Inspection, Testing, And Maintenance Of Fire Alarm Systems


MNEC NFPA 72 WHITE PAPER

The 2013 National Fire Alarm and Signaling Code

Protecting Your Property: Well Do You Know Your Fire Fire Systems Systems. Joe Szewczyk, Risk Control Consultant

GE Security Vigilant Fire & Life Safety. Easy. V-Series Intelligent Life Safety Systems

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 5, 2018

/5121/5122 TrueAlert Power Supply Installation Instructions

Functional Performance Test

Product Guide. Fire Alarm Cables. Initiating Device, SLC Lines, and NAC Cables.

2019 COURSE CATALOG (rev )

Case Study Media Contact Beth Welch, or

16721 FIRE ALARM AND DETECTION SYSTEMS

Using Ethernet and Networks for Fire Alarm and Emergency Communications Systems

Division 28 - Electronic Safety and Security

Rev. B. TrueAlert Addressable Controller Application Manual

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

2. HVAC and smoke control systems; fire, smoke, and combination fire/smoke dampers. 5. Central control and monitoring system.

PROTECTED PROPERTY. City: State: Zip Code: ALARM SERVICE COMPANY. City: State: Zip Code: COMMENTS AND CLARIFICATIONS ALARM SYSTEM DESCRIPTION

16721 FIRE ALARM AND DETECTION SYSTEMS

1. Floor above/floor below notification. 2. Private alarm notification. 3. Not Used 4. Voice alarm notification. 5. Not Used.

Signature Series Auto-Sync Output Module (CC1S)

FIRE ALARM AND DETECTION SYSTEMS

Required vs. Non-required Fire Protection Systems. Dan Austin Chief Fire Code Consultant/State Fire Protection Engineer

FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Addressable NAC Output Module D327A

30.45 Electric Release PDRP-2001

LifeAlarm Fire Alarm Controls

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

Advanced Fire Alarm Systems Training Program Outline (5 Day)

SECTION ADDRESSABLE FIRE ALARM SYSTEM

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

University Design Standard Fire Alarm Systems

SECTION FIRE ALARM SYSTEMS

Fire Alarm and Life Safety System Inspection Certificate

PART 1 GENERAL Quality Assurance A. Fire Alarm Contractor Qualifications:

3.1 Introduction. 3.1 Introduction

PART 1 GENERAL Quality Assurance A. Fire Alarm Contractor Qualifications:

Doc. No Part No Rev. U * T*

TrueAlert Addressable Notification Appliances

SECTION DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM

FAST, INTELLIGENT FIRE ALARM SYSTEMS THAT DELIVER IT ALL

TrueAlert Addressable Notification Appliances

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Questions/Comments for Richard Roux from Webinar on 7/11/13

Session: Fire Alarm Installation

Full Service Central Station Fire Alarm Listing Evaluation

Notification Appliance Circuit Module

Releasing Systems. Rob Mennie Senior Consultant Gage-Babcock & Associates Ltd.

Fire Alarm Inspection, Testing, Maintenance. Assuring the System s Operational Reliability

Minutes of the Pre-ROP Meeting of the T/C on Protected Premises Signaling September 22-23, 2010 Indianapolis, IN

Case Study Media Contact Beth Welch, or

AND ARCHITECT SPECIFICATIONS

TrueAlert Addressable Notification Appliances

THIS ORDINANCE ONLY AFFECTS EXISTING FIRE ALARM SYSTEMS.

Fire Alarm System Fundamentals Presented By: Shamim Rashid-Sumar, Vice President Middle East Operations Rolf Jensen and Associates, Inc.

SECTION FIRE ALARM SYSTEMS

Specification/ Data Sheet

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

1 Exam Prep Fire Alarm Signaling Systems Tabs and Highlights

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

A COMPARISON OF FIRE ALARM SYSTEM REQUIREMENTS IN THE US AND UK. James R. Lugar Jr., P.E. Rolf Jensen & Associates, Inc. SFPE 2012 Savannah, GA

Fire Pump Supervision - Part 3 by Dean K. Wilson, P.E.

FIRE SAFETY REQUIREMENTS FOR PRE RESIDENTIAL BUILDINGS OF THREE OR MORE STORIES (DOROTHY MAE ORDINANCE - NO. 158,963)

Brighton Area Fire Authority

Minimum Standards for Engineers Practicing Fire Protection Engineering in the State of Oklahoma September 14, 2016

ONYX FirstVision Specification Interactive Firefighters Display

CAN/ULC-S1001, INTEGRATED SYSTEMS TEST OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS

AND ARCHITECT SPECIFICATIONS

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

Scope. Warning sounders except specific requirements. Intercom Systems for Emergency Purposes. Sound Systems for Emergency Purposes

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays

NEC Requirements for Standby Power Systems. New England Building Officials Education Association Annual Conference October 5, 2015

Written Fire Safety Plans

SP40S-D. Kingfisher Company, inc. Features: Description:

STUDY AND TEST MATERIAL FOR THE. FA2 and FA4 ASSESSMENTS. (Fire Alarm On-Site and Business Cert. Holder) June 14, 2017

Transcription:

Fire Alarm Wiring Circuit types, styles and limitations

What we will cover Types Classes Notification Appliance Circuits (NAC) Initiating Device Circuits (IDC) Signaling Line Circuits (SLC) Class A, B, C, D, E, & X Survivability Limitations Attendee Discussion Questions and Answers What to watch out for in the real world Capacitance Voltage Drops Power Limited vs Non-Power Limited

Types Notification Appliance Circuits/Control Circuits (NAC) Supervised polarity reversing power circuits for Horns, Strobes, Bells, Chimes Any NAC that does not have a Notification Appliance attached shall be considered a Control Circuit Performance shall be based upon wiring Class (Note the old Class & Style has been replaced with Class only) Troubles (Opens, Shorts or Grounds) must be reported within 200 seconds Alarms must activate NACs and Control circuits within 10 seconds Survivability, an Open, Short or Ground cannot affect any other NAC for more than 200 seconds Faults on Addressable Notification Devices that are in different notification Zones but on the same SLC can not interfere with those in other notification zones.

Types Continued Initiating Device Circuits (IDC) A circuit where Automatic or Manual Initiating Devices are connected and the signal does NOT identify the individual device operated. Performance shall be based upon wiring Class (Note the old Class & Style has been replaced with Class only) Alarms must activate NACs and Control circuits within 10 seconds Troubles (Opens, Grounds) must be reported within 200 seconds No more than 5 Waterflow devices and no more than 20 Supervisory devices per IDC

Types Continued Signaling Line Circuits (SLC) A circuit where any combination of addressable devices connect to system interface containing both input and/or output signals Performance shall be based upon wiring Class (Note the old Class & Style has been replaced with Class only) Troubles (Opens, Shorts or Grounds) must be reported within 200 seconds Alarms must activate NACs and Control circuits within 10 seconds Survivability, an Open, Short or Ground cannot affect any other SLC Controlled NAC for more than 200 seconds Faults on Addressable Notification Devices that are in different notification Zones but on the same SLC can not interfere with those in other notification zones.

Types Continued Initiating Device Circuits (IDC) A circuit where Automatic or Manual Initiating Devices are connected and the signal does NOT identify the individual device operated. Performance shall be based upon wiring Class (Note the old Class & Style has been replaced with Class only) Alarms must activate NACs and Control circuits within 10 seconds Troubles (Opens, Grounds) must be reported within 200 seconds No more than 5 Waterflow devices and no more than 20 Supervisory devices per IDC

Class A Class A has the benefit of a redundant pathway back to the control panel. That pathway assures that any signal is received at the control panel. This wiring Class applies to NAC, IDC and SLC (except the SLC with Short Circuit Isolation) The NFPA 72 2013 recognizes the use of Fiber Optic cable and is not affected by shorts of grounds.

Class B Class B has no redundant pathway back to the control and as such is more susceptible to wiring faults. This wiring Class applies to NAC, IDC and SLC

Class C, D & E System integration is addressed in Classes C, D & E. Class C is for wired Ethernet devices where the pathway is not as important as the communication between both ends of the pathway. (NFPA 72 2016 introduces Class N which is a 4 wire [Class A like] wiring method) Class D is for FailSafe operating circuits Class E is for ancillary Non-Supervised circuits

Class X Class X is the new designation for SLC Style 7 wiring Includes a Class A like redundant pathway It is supposed to allow the circuit to remain functional even with a wire-to-wire short

Survivability The level of survivability required is dependent on the type of fire alarm system being installed. A higher level of survivability applies to systems used for relocation or partial evacuation of occupants Levels of Survivability are 1-3, depending on if the wiring is within an Evacuation Signaling Zone (ESZ) or not An ESZ is a discrete area of a building, bounded by smoke or fire barriers in which occupants are intended to relocate or evacuate. Level 0 means no survivability is required (wiring within the ESZ) Level 1-3 indicate that attack by fire shall not impair the control and operation of Notification Appliances outside the ESZ

Survivability Continued The Key Concept behind Levels 1-3 is the Fact that Metal Raceway only protects wiring against Mechanical Damage, NOT Damage by Fire. Level 1, In buildings that are protected by an Automatic Sprinkler System and who s wiring is installed in Metal Raceways Level 2 can be accomplished by, A, 2-hour rated CI Wire OR B, 2-hour fire rated cable system OR C, 2-hour fire rated enclosure OR D, 2-hour performance alternative approved by the AHJ Level 3, a combination of Levels 1 & 2.

Survivability Continued When attack by fire will affect signaling and control outside of the ESZ, then pathway survivability Levels 2-3 are used (at the discretion of the AHJ) When the wiring outside of the ESZ is necessary for the operation and control of Notification Appliances until it enters the ESZ, Level 2-3 must be used CI rated Cables may be used where pathway survivability Level 2-3 is required. CI Cables are not required for Levels 0-1. Follow NEC 760 and the AHJ s guidance

Let s talk Questions? Field issues? What s next in this series of Fire Alarm Tech Presentations