I P Explosion Proof Starter 1Ø & 3Ø, 115~600VAC, 1 75HP START/STOP AND RESET PUSHBUTTONS ELECTRONIC MOTOR PROTECTION Tough Starters for Tough Environments Ready to Install, Completely Wired and Assembled Door mounted Start, Stop & Reset pushbuttons/pc Enclosure door features durable NEMA 4 gasket All starters include pre-drilled conduit holes Fast turn around time* 5-Year contactor warranty Flexible Control Power Transformer (CPT) Multi-tap CPT input accepts all common motor voltages Integrated secondary protection no fuses required Standard 120VAC secondary control Wide Range Class 1-30 Electronic Overload Prevents ordering confusion and eliminates call backs due to mis-sized heaters Advanced protective features including phase loss, phase imbalance, stall protection & manual reset Combination Versions Include Disconnect Wide range electronic overload eliminates sizing call backs. Motor circuit protection disconnect provides short circuit protection High interrupting ratings for maximum electrical system compatibility No fuses required save time and money Lockable cast aluminum breaker handle for safety Customize to Meet Your Application* High quality components complete a UL listed starter package. 2 or 3 position selector switches Long life LED pilot lights Additional conduit entries Emergency Stop pushbutton Installed Breather & Drain Lockable cast aluminum disconnect handle is safe and secure.
Specifications Starter Type IXP - Explosion Proof Starter Across the line or Full Voltage Non-Reversing NEMA 7 Enclosure User Interface Start/Stop Pushbuttons OR Hand/Off/Auto Mechanical Enclosure Type NEMA 7 Environmental Ambient Operating Temp -5 to 140 F (-20 to 60 C) Ambient Storage Temp -5 to 185 F (-20 to 85 C) Relative Humidity 5% to 95% non-condensing (NEMA 1) Motor Protection Adjustment/Description Overload Type Electronic; I 2 t Thermal Trip Curve Current Setting Range 0.3-1.5A, 1-5A, 4.4-22A, 8-40A, 16-80A Trip Class Class 1-30 Reset Manual Phase Unbalanced Trip within 3 seconds @ 70% unbalance Phase Loss Trip within 3 seconds Stall Condition Trip within 3 seconds @ 170% FLA Ordering and Sizing Information NEMA 7 EXPLOSION PROOF ENCLOSURE COMBINATION MAGNETIC STARTERS - Electronic Overload HP Three Phase 200V 230V 460V 600V* 3/4 3/4 NEMA SIZE IXP w/ Start/Stop IXP7-9/J-G1.6-5 IXP w/ HOA IXP7-9/J-G1.6-5H 1/2 1/2 1 1.5 IXP7-9/J-G2.5-5 IXP7-9/J-G2.5-5H 3/4 3/4 2 3 00 IXP7-9/J-G4-5 IXP7-9/J-G4-5H 1 1.5 3 3 IXP7-9/J-G6-5 IXP7-9/J-G6-5H 2 2 5 5 IXP7-9/J-G8-22 IXP7-9/J-G8-22H 2 3 5 7.5 IXP7-18/J-G10-22 IXP7-18/J-G10-22H 3 3 7.5 10 0 IXP7-18/J-G13-22 IXP7-18/J-G13-22H 3 5 10 15 IXP7-18/J-G17-22 IXP7-18/J-G17-22H 5 7.5 15 20 IXP7-32/J-G22-40 IXP7-32/J-G22-40H 7.5 7.5 15 20 1 IXP7-32/J-G26-40 IXP7-32/J-G26-40H 7.5 10 20 25 IXP7-32/J-G32-40 IXP7-32/J-G32-40H 10 10 30 30 IXP7-50/J-G40-80 IXP7-50/J-G40-80H 2 15 15 30 40 IXP7-50/J-G50-80 IXP7-50/J-G50-80H 20 20 40 50 IXP7-85/J-G63-80 IXP7-85/J-G63-80H 20 25 50 60 3 IXP7-85/J-G75-80 IXP7-85/J-G75-80H 25 30 60 75 IXP7-85/J-G90-80 IXP7-85/J-G90-80H www.franklin-controls.com 1.800.962.3787
NEMA 7 EXPLOSION PROOF ENCLOSURE STANDARD MAGNETIC STARTERS - Electronic Overload HP Three Phase 200V 230V 460V 600V* NEMA SIZE IXP Part Number IXP w/ HOA 1 1.5 3 3 00 IXP7-9/J-5 IXP7-9/J-5H 3 5 10 15 0 IXP7-18/J-22 IXP7-18/J-22H 7.5 10 20 25 1 IXP7-32/J-40 IXP7-32/J-40H 15 15 30 50 2 IXP7-50/J-80 IXP7-50/J-80H 20 25 50 60 3 IXP7-85/J-80 IXP7-85/J-80H OPTIONS Part Number IXP-XHPP IXP-XHS1 IXP-XLS IXP-XDB IXP-XDB2 IXP-XLP Description E-Stop Red Pushbutton, 1N.C. 2-Position Selector Switch, 1N.O. & 1N.C. Pilot Light, 120VAC Breather & Drain Installed Bottom* Breather & Drain Installed* Push-To Test Light, 120VAC 1N.O. & 1N.C. IXP-NP Nameplate, Specify Text (1 x 4 inch) IXP-ENT Additional Conduit Entry* Standard (no disconnect) Dimensions Part numbers: (IXP7-18/J-5) - (IXP7-85/J-80) 12 3 4 17 3 8 10 5 8 13 3 8 8 3 8
Combination (with disconnect) Dimensions Part Numbers: (IXP7-18/J-G1.6-5) - (IXP7-32/J-G32-40) 13 17 3 8 A 10 5 8 13 3 8 8 1 2 Combination (with disconnect) Dimensions Part Numbers: (IXP7-50/J-G40-80) - (IXP7-85/J-G90-80) 15 3 4 15 3 4 22 1 4 14 1 8 14 1 8 16 1 4 10 3 4 www.franklin-controls.com 1.800.962.3787
Wiring Schematic Standard schematic shown, actual schematic may vary.