VAMP 120 & 121. Arc flash detection units. Product picture

Similar documents
VAMP 120 & 121. Arc Flash Protection Units. Arc Protection. Customer benefits

VAmP 120. Arc Flash Protection Units. Arc Protection. Customer benefits

VAMP 121. Arc protection unit. User manual

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

AQ 100 Series. Arc Flash Protection System

REA 105 Arc Protection Module. Operator s Manual

Delta XRD. Supervision Relays. rms A U X I L I A R Y T R I P P I N G S U P E R V I S I O N

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

Annunciator Unit SACO 16 D1. Product Guide

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

Operation and use. Functions and characteristics

1. General Safety Block diagram Description of operation Connections Commissioning...11

Annunciator unit. Application

7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for Infrastructure & Cities.

www. ElectricalPartManuals. com Annunciator unit Features Self-contained microprocessor-based annunciator unit with 64 alarm channels Application

Analog Annunciator Unit SACO 16 A3. Product Guide

SENTINEL A - Fault Passage Indicator

SENTINEL D - Fault Passage Monitoring

Laboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka

Universal fault annunciator for panel mounting

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

QA(13) - Series Miniature Circuit Breakers

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

Ordering Key. Dielectric strength

INPUT / OUTPUT MINI MODULES

Mors Smitt Industrial Technology. Substation Protection & Control. High Performance Electromechanical Relays. RMS Mors Smitt A Wabtec company

BE1-50/51B with S1 Case or FT-11 sized Case and Cover For non-retrofit applications, see Product Bulletin UHD.

Audible warning devices for external alarm

Remote NAC Power Supply D7038

Rules for Intruder Alarm Systems

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

CII FCAC-150 Series Relay

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

1S20 User Guide. Arc Fault Monitor. Advanced Protection Devices. relay monitoring systems pty ltd. User Guide. Test Manual

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Installation / Monitoring Technique

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

Operating Manual TR600

Overload relays. General descriptions. Configuration of the front

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Soft Starter AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

EARTH LEAKAGE RELAY. User Manual - Issue 1.0

RSWT. Three phase AC pumps and ventilators soft starter. Benefits. Description

4 & 8-POINT ANNUNCIATORS Instruction Manual

PIR movement and presence detectors 10 A

Arc Fault Protection System D1000

ESP TECHNOLOGIES LIMITED

D1000 Arc-fault Protection System

C-Bus Four Channel General Input Unit Installation Instructions

M2500 Engine Controller Installation Manual

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

Operating Instructions. For. Alarm Control Module. Model SSR 500

AO Annunciator Module

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

I.S. Interfaces. for the Process Industry. display. i.s. interface. isolation. temperature. universal

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Annunciator Relay MR 11 and MRE 11 MR 21 and MRE 21. Automation Equipment. Power Station Control Systems. Control Room Technology

Delivering reliable power for patient safety

Panel Mounted Fault Annunciator Series

Soft Starter Centrifugal Pump Soft Starter Series

Pump Logic User Manual CB-1000 P/N ILK-CB1000-1

Welcome to Hager Presentation

M2000 Engine Controller

RTO. User guide 05/

Residual Current Devices

Emergency power automatics MS-2. High resistance to shock, vibrations and transients. All output are 2A relay contacts

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

SECTION AUTOMATIC TRANSFER SWITCHES

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

DTA. Motor thermistor relay. Benefits. Description

Technical Manual. Level Alarm Unit CARLA & WIDS

1.7. Insulation fault evaluators EDS460/490 EDS461/491

DEIF A/S. Technical Manual. Type EC-2 Engine Control Unit D. Technical Manual

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

IEC UC3 compliant (short current 3,000 A) 1 Form A 120A power latching relays

LINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry

Reyrolle Protection Devices. 7PG26 DAD High Impedance Current Relay. Answers for energy

DTA04. Motor thermistor relay. Benefits. Description

1S26 User Guide. Arc Fault Monitor + Integrated Current Check Relay. Advanced Protection Devices. relay monitoring systems pty ltd.

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current. Output Voltage Range

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

C-Bus Four Channel Analogue Output Unit Installation Instructions

Safety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS

MSM - Expansion modules

VdS SCHADENVERHÜTUNG. VdS-Rules for Intruder Alarm Systems

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Intelligent metering and control devices. Typical applications. Features. Measure and control energy costs. Improve power quality and reliability

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

Development of standards for MV Switchgear for Arc Flash protection. ABB Group May 20, 2013 Slide 1

Transcription:

Arc flash detection units VAMP 120 and 121(D) are extremely fast arc flash detection units for LV and MV switchgear and controlgear. The units are especially designed to increase the safety and to minimize material damage caused by arc faults. Customer benefits Product picture Reduces loss of production The shorter the operate time of the arc flash detection unit the smaller the damage caused by the arc fault will be and the shorter the possible outage of the power supply. Prolonged switchgear life cycle A modern arc protection unit increases the life-cycle expectancy of switchgear installations, investment decisions in new switchgear installations can be postponed and money can be saved by re-vamping existing switchgear systems. Reduced insurance costs The faster and better the protection system of a power installation is, the more generous the insurance terms and costs will be. Low investment costs and fast installation A comprehensive arc protection is characterized by low investment costs and a fast installation and commissioning time. One successful operation of the arc flash detection units provides immediate investment pay off. Reliable operation Function is based on appearance of light or alternatively on the appearance of light and current from an external equipment. Immune to nuisance trippings! Vast experience Schnerider Electric is the pioneer in the field of arc flash protection with more than 15,000 VAMP arc flash protection systems and units with over 00,000 arc detection sensors in service world-wide

Arc flash protection overview and the application schneider-electric.com 2 Modern society heavily depends on an uninterrupted supply of electric power. Prolonged power outages cause loss of business to the power supplier and loss of production to the power consumer. Regardless how safe a power system is, faults do occur. This being the case the damage caused by power system faults must be kept to a minimum level. The ultimate solution is to selectively isolate the fault as fast as possible, while maintaining the operation of the healthy network parts. Secure your assets VAMP arc flash protection is an extremely fast protection system for LV and MV switchgear and controlgear. Vamp arc flash protection increases the safety and minimizes the material damage of the installation in the most hazardous power system fault situations. The arc protection unit detects an arc flash in an installation and trips the feeding breaker. On detection of a fault the arc flash detection unit immediately trips the concerned circuit breaker(s) to isolate the fault. An arc flash protection system operates much faster than conventional protection relays and thus damage caused by an arc short circuit can be kept to a minimum level. Why arc flash protection? When the traditional time-grading or blocking based protection coordination principle is used, the traditional protection systems may not provide fast enough protection of substation faults. Further, high-impedance type of earth-faults may cause prolonged operation times of earth-fault relays leading to the significant release of the arcing energy. These facts pose a considerable risk to operators and economical assets. VAMP 121(D) applied for the switchgear application Every compartment is equipped with an arc sensor. Up to ten sensors can be connected to the VAMP 121(D) unit. The trip relay is electromechanical and can be connected directly to control the circuit-breaker. TRIP L> OUT IN up VAMP 121 Power +25V dc

Typical applications schneider-electric.com VAMP 120 applied for wind power applications VAMP 120 provides the most simple, straight- forward and economical solution designed for wind power applications Emergency Shut Down eneral Trip Alarm SF Alarm Trip Signal (NC) TRIP CB Trip... TRIP VAMP 120 applied for arc flash detection at medium size power generation plant rid Possible arc flash in busbar or circuit breaker compartment trips the grid and all generator units. Should the arc flash fault happen in cable area, an emergency shut down for the concerned generator unit is activated. Z 1 Z 1 eneral trip eneral trip eneral trip eneral trip CB trip CB trip CB trip CB trip Z 2 Z 2 Z 2 Z 2 Emergency shut down Trip alarm SF alarm Emergency shut down Trip alarm SF alarm Emergency shut down Trip alarm SF alarm Emergency shut down Trip alarm SF alarm ARC TRIP ALARM IRF

22.5-28.5 V DC DC OK Product characteristics and highlights schneider-electric.com 4 Common features Operation on light only Supports point or smoke sensors Straight-forward installation Cost-efficient solution Self-supervision VAMP 120 arc flash detection unit VAMP 121 ans 121D arc flash detection units Up to 4 sensors Selective trip for 2 zones and possibility for generator set emergency trip (separate contact) Operation time typically 7 ms (including the output relay) Non-volatile trip status Input for current criteria for I> & L> operation NO & NC trip outputs (Zone 1) Integrated 19 265 V ac/dc aux. supply Optimized for wind power and other small applications Up to 10 sensors Single trip contact Operation time typically 9 ms (including the output relay) Binary input for blocking or resetting (programmable) the unit Possibility for double arc channel activation trip criteria BIO light transfer to other Vamp device Additional feature to VAMP 121D Door mounted, text pocket for sensor specific labels Connection diagrams VAMP 120 RESET 18...265Vac/dc I> Bin In 18...265Vac/dc SF Alarm TRIP 2 (NO) TRIP Alarm TRIP 1 (NO) TRIP Signal (NC) Power supply 19..265 Vdc 40...265Vac VAMP 121(D) SUPPLY UNIT - - + + - - + DC OK - - + + OUT DC 24V 1.A MINI POWER VAMP 120 - - + DC OK IN AC 100-240V L(+) NC NC N(-) * * * * 2 1 4

Accessories schneider-electric.com 5 Point sensors Easy installation and replacement Enables fault location indication Surface mounting Tube mounting Continuous self-supervision Portable sensor VA1DP Provides extra personal safety while working on live switchgear Quick connection with snap-in socket Portable sensor VA1DP-5 Snap-in socket connection to sensor I/O unit Point sensor VA1EH-x 1) (pipe) Sensor mounting plates Z- or L-shaped Wall mounting to VA1DA-x sensors (no extra holes in the switchgear) Point sensor VA1DA-x 1) (surface) Portable sensor VA1DP-5D Snap-in socket connection to sensor I/O unit via VX01-5 cable VYX001, Z-shaped VYX002, L-shaped VX01-5 Extension cable Extension cable VX01-5 Extension cable and door socket for VA1DP-5D Diplexer for two portable sensors V120 Flush mount KIT Line amplifier P001 Flare, solid state relay with 6.2 mm overall width Output, transistor module, spring clamp terminal, jumper at negative pole at the control side Alarm relay P007 Relay terminal block, with soldered-in miniature power relay Contacts (AgSnO): medium to large loads, 1 PDT, input voltage 24 V DC For assembly on NS 5/7.5 Terminal width 6.2 mm Power supply unit P004 Primary-switched MINI POWER power supply for DIN rail mounting Input: 1-phase, output: 24 V DC/1. A Trip multiplier relay VAMP 4R 4 + 4 trip outputs (4 x NO and 4 x NC) Two separate tripping groups Enables a 7 ms total operation time to a large number of CBs (controlled by binary output (BO) of VAMP 121 unit) External auxiliary power supply

Order codes schneider-electric.com 6 VAMP 120 Order code V120 Description Arc flash detection unit, DIN rail mounted Accessories for VAMP 120 Order code Description Note VA 1 DA-6 Arc Sensor Cable length 6 m VA 1 DA-20 Arc Sensor Cable length 20 m VA 1 EH-6 Arc Sensor (Pipe type) Cable length 6 m VA 1 EH-20 Arc Sensor (Pipe type) Cable length 20 m VA 1 EH-6S-IP Arc Sensor, shielded (Pipe type, IP65) Cable length 6 m VA 1 EH-20S-IP Arc Sensor, shielded (Pipe type, IP65) Cable length 20 m VA 1 EH-20-IP Arc Sensor (Pipe type, IP65) Cable length 20 m VX01-5 Extension cable for VA1DP-5D Cable lenght 5 m VYX001 Surface Mounting Plate for Sensors Z-shaped VYX002 Surface Mounting Plate for Sensors L-shaped V120-F-KIT V120 Flush mount KIT For panel mounting VAMP 121 Order code V121 V121D Description Arc flash detection unit, DIN rail mounted Arc flash detection unit, door mounted Accessories for VAMP 121 Order code Description Note VA 1 DA-6 Arc Sensor Cable length 6 m VA 1 DA-20 Arc Sensor Cable length 20 m VA 1 EH-6 Arc Sensor (Pipe type) Cable length 6 m VA 1 EH-20 Arc Sensor (Pipe type) Cable length 20 m VA 1 EH-6S-IP Arc Sensor, shielded (Pipe type, IP65) Cable length 6 m VA 1 EH-20S-IP Arc Sensor, shielded (Pipe type, IP65) Cable length 20 m VA 1 EH-20-IP Arc Sensor (Pipe type, IP65) Cable length 20 m VA 1 DP-5 Portable Arc Sensor Cable length 5 m VA 1 DP-5D Portable Arc Sensor Cable lenght 5 m VX01-5 Extension cable for VA1DP-5D Cable lenght 5 m VYX001 Surface Mounting Plate for Sensors Z-shaped VYX002 Surface Mounting Plate for Sensors L-shaped P001 Line amplifier for arc protection BI/O channels DIN rail mount P004 Supply unit, 100-240AC/24DC/1.A P007 Alarm relay, Phoenix DEK-REL-24/21

Technical characteristics VAMP 120 unit Power Supply Us Pmax TRIP Contacts Rated voltage Continuous carry Make and carry for 0.5 s Make and carry for s 19 265 V dc / 40 265 V ac 4 W 2 pcs 250 V ac/dc 5 A 0 A 15 A t> 7 ms Digital Inputs Rated voltage Number of inputs 2 VAMP 121 / 121D units Power Supply Us In (stand-by) I sensact 18 265 V ac/dc 24 V dc 0 ma 20 ma Iarc 120 ma ( IsensAct x n) * Tripping Contacts Rated voltage Continuous carry Make and carry for 0.5 s Make and carry for s Breaking capacity DC, when time constant L/R=40 ms Contact material 1 pc NO 250 V ac/dc 5 A 0 A 15 A 50 W AgNi t> 9 ms BIO Inputs/Outputs Rated voltage Rated current / output Rated current / input Number of inputs 1 Number of outputs 1 +24 V 20 ma (max) 5 ma P001 line amplifier Wieland type Coil circuit Operating voltage Minimum input voltage Maximum input voltage Nominal input current Status display Switching characteristics Nominal switching voltage Maximum switching voltage Maximum switching current DC1 0 / 110 / 220 V DC Min. switching voltage Min. switching current Max. switching frequency Pick-up delay Release delay schneider-electric.com 7 flare 24VDC/48VDC-2A 24 V dc 0-5 V dc 10-5 V dc 4-7 ma LED yellow 4.4-5 V dc 5 V dc 2 A 4.4 V dc 1 ma 5 Hz 1 ms 5 ms P004 power supply unit Phoenix type Input Data Nominal input voltage MINI-PS-100-240AC/24DC/1. 100 V ac 240 V ac Nominal output voltage 24 V dc ±1% AC input voltage range DC input voltage range AC frequency range DC frequency range Output Data 85 V ac 264 V ac 90 V ac 50 V dc 45 Hz 65 Hz 0 Hz Nominal output voltage 24 V DC ±1% Output current P007 alarm relay Phoenix type Coil side Nominal input voltage Un Contact type 1. A (-25 C 60 C) DEK-REL-24/21 24 V dc Input voltage range in reference to Un 0.8 1.1 Limiting continuous current Nominal input current at Uin Contact material Typical response time Maximum switching voltage Minimum switching voltage Maximum inrush current Min. switching current Limiting continuous current Single contact, 1-PDT 6 A 9 ma AgSnO 8 ms 250 V ac/dc 12 V 68 ac/dc 6 A 10 ma 6 A

schneider-electric.com 8 Disturbance tests VAMP 120 VAMP 121 / VAMP 121D Emission EN 61000-6-4, IEC 60255-26 EN 61000-6-4, IEC 60255-26 Standard & Test class / level Test value Standard & Test class / level Test value Conducted EN 55011, Class A / IEC 60255-25 0.01-0 MHz EN 55011, Class A / IEC 60255-25 0.01-0 MHz Emitted EN 55011, Class A / IEC 60255-25 0-1 000 MHz EN 55011, Class A / IEC 60255-25 0-1 000 MHz Immunity EN 61000-6-2, IEC 60255-26 EN 61000-6-2, IEC 60255-26 1Mhz damped oscillatory wave IEC 60255-22-1 ±2.5kVp CM, ±2.5kVp DM IEC 60255-22-1 ±2.5kVp CM, ±1.0kVp DM Static discharge (ESD) EN 61000-4-2 Level 4 / EN 61000-4-2 Level / ±8 kv contact, ±16 kv air IEC 60255-22-2 Class 4 IEC 60255-22-2 Class ±6 kv contact, ±8 kv air Emitted HF field EN 61000-4- Level / EN 61000-4- Level / 80-2700 MHz, 10 V/m IEC 60255-22- IEC 60255-22- 80-2700 MHz, 10 V/m Fast transients (EFT) EN 61000-4-4 Level 4 / EN 61000-4-4 Level 4 / ±4 kv 5/50 ns, 5 khz IEC 60255-22-4 Class A IEC 60255-22-4 Class A ±4 kv 5/50 ns, 5 khz Surge EN 61000-4-5 Level 4 / ±4 kv, 1.2/50 μs, CM EN 61000-4-5 Level / ±2 kv, 1.2/50 μs, CM IEC 60255-22-5 ±2 kv, 1.2/50 μs, DM IEC 60255-22-5 ±1 kv, 1.2/50 μs, DM Conducted HF field EN 61000-4-6 Level / IEC 60255-22-6 0.15-80 MHz, 10 Vemf EN 61000-4-6 Level / IEC 60255-22-6 0.15-80 MHz, 10 Vemf Power-frequency magnetic field EN 61000-4-8 00 A/m (continuous), 1000 A/m 1- s EN 61000-4-8 00 A/m (continuous) Pulse magnetic field EN 61000-4-9 Level 5 1000A/m, 1.2/50 μs EN 61000-4-9 Level 5 1000A/m, 1.2/50 μs Voltage interruptions EN 61000-4-29 / IEC 60255-11 0%/1s, 60%/0.1s, 100%/0.05s Voltage alternative component EN 61000-4-17 / IEC 60255-11 15% of operating voltage (DC) / 10min Voltage dips and short interruptions Electrical safety tests EN 61000-4-11 0%/10ms, 100%/10ms, 60%/100ms >95%/5000ms Standard & Test class / level Test value Standard & Test class / level Test value Impulse voltage withstand EN 60255-5, Class III 5 kv, 1.2/50 μs EN 60255-5, Class III 5 kv, 1.2/50 μs Dielectric test EN 60255-5, Class III 2 kv, 50 Hz EN 60255-5, Class III 2 kv, 50 Hz Insulation resistance EN 60255-5 EN 60255-5 Protective bonding resistance EN 60255-27 Power supply burden IEC 60255-1 Mechanical tests Device in operation Vibrations Shocks Device de-energized Vibrations Shocks Bump Environmental conditions Standard & Test class / level Test value Standard & Test class / level Test value IEC 60255-21-1, Class II / IEC 60255-21-1, Class I / 1n, 10Hz 150 Hz IEC 60068-2-6, Fc IEC 60068-2-6 Fc 0,5n, 10Hz 150 Hz 5n/11ms 5n/11ms IEC 60255-21-1, Class II / IEC 60068-2-6, Fc 2n, 10Hz 150 Hz 15n/11ms 10n/16ms Ambient temperature, in-service -5 +60 C -5 +70 C Ambient temperature, storage -40 +70 C -40 +70 C IEC 60255-21-1, Class II / IEC 60068-2-6, Fc Relative humidity < 95%, no condensation allowed < 95%, no condensation allowed Maximum operating altitude 2000 m 2000 m Degree of protection (IEC 60529) IP20 IP20 1n, 10Hz 150 Hz 15n/11ms 10n/16ms Schneider Electric Industries SAS 5, rue Joseph Monier CS 02 F - 92506 Rueil Malmaison Cedex (France) Tel.: + (0) 1 41 29 70 00 RCS Nanterre 954 50 49 Capital social 896 1 776 www.schneider-electric.com As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication. Design: Schneider Electric Industries SAS Photos: Schneider Electric Industries SAS Printed: 10-2018 NRJED11107EN 2018 Schneider Electric Industries SAS - All rights reserved