WHEA FSE inspections.

Similar documents
Other EC and LS documents may be requested by surveyors, as needed, throughout the survey.

EC 5.10 FIRE PREVENTION MANAGEMENT

Final EC Inspection Report 03/2010

10/28/2015. Enjoy Your TJC Survey. Bill H. McCully CHFM SASHE. Senior Consultant MSL Healthcare Partners. MSL Healthcare Partners, 2015 PREPARATION

NFPA CODE TESTING & INSPECTION. Requirements & Recommendations for. Licensed Florida Hospitals, Ambulatory Surgery Centers,

Global Property. QUARTERLY FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:

Winnipeg Fire Department Fire Prevention Branch

Global Property. SEMIANNUAL FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:

Service Requirements SEMI- ANNUAL ANNUALLY OTHER REF. REQUIREMENT

TIPS FOR BETTER JOINT COMMISSION SURVEYS

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment

Skilled Healthcare Documentation Requirements Life Safety and Fire Protection

Southaven Fire Department Fire Marshal s Office 8710 Northwest Drive Southaven, Mississippi Phone: Fax:

Danilo B. Concepcion, CBNT, CCHT-A Operations Manager St. Joseph Hospital Renal Services

Changes to Environment of Care, Equipment Management, and Life Safety Chapters Related to Life Safety Code Updates

NFPA 96, 2017 REVIEW SUMMARY

INSPECTION AND TESTING FORM

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

2-SUPPRESSION REQUIREMENTS - CODE REQUIRED INSPECTIONS TEST Page 1 of 7

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

Changes to Environment of Care and Life Safety Chapters Related to Life Safety Code Updates

System Test Report CLEAN AGENT

Today s Webcast starts at 1:00 p.m. Eastern. You will not hear audio un=l the Webcast begins

Valuation: # of Plans Submitted: # of pages: Type of Work (select one): New Addition Existing System/Modification Project Name: Scope of Work:

Changes to Environment of Care and Life Safety Chapters Related to Life Safety Code Updates

New Construction Fire Inspection Process

Iowa State Fire Marshal

Protecting Your Property: Well Do You Know Your Fire Fire Systems Systems. Joe Szewczyk, Risk Control Consultant

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry Plan Review

Type of Fire Alarm Control Panel: System is: Existing OR New If new, provide Electrical Permit Number:

LIFE SAFETY & FIRE PREVENTION MANAGEMENT PLAN

LIFE SAFETY CODE MAINTENANCE MANUAL

Agency for Health Care Administration

Fire Alarm and Life Safety System Inspection Certificate

MAINTENANCE OF FIRE PROTECTION DEVICES WITHIN RESIDENTIAL SUITES OF MULTI-FAMILY BUILDINGS

Florida Building Code 2010

FIRE INSPECTORS GUIDELINES FOR PLAN REVIEWS AND INSPECTIONS OF NEW CONSTRUCTION / ADDITIONS AND CHANGE OF OCCUPANCY

Understanding and Applying NFPA 25

MODULE 8. Tying the Systems Together: Emergency Control Functions and Interfaces

Life Safety Code NFPA 10 NFPA 13 NFPA 25 NFPA 72 NFPA 90A NFPA 110 NFPA 99 THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #7

CMS Announcement 3/27/2017. Adoption of 2012 Life Safety Code Health Care Facilities Code. Kenneth Daily, LNHA

Sheetz Inc. Fire Protection Service Guidelines

Fire Alarm System Inspection and Testing Report

Crosswalk of 2014 HFAP Standards against HFAP Standards Acute Care Hospital Manual

FACILITY MANAGEMENT DEFICIENCIES IN CRITICAL ACCESS HOSPITALS (CAH)

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course

Unified Fire Authority - Fire Prevention Bureau

FACILITY MANAGEMENT DEFICIENCIES IN ACUTE CARE SETTINGS

Tennessee Department of Health Bureau of Health Licensure and Regulations Division of Health Care Facilities

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

Standards Revisions Related to Life Safety Code Update

Today s Webcast starts at 1:00 p.m. Eastern. You will not hear audio until the Webcast begins

109-B Concord Drive Casselberry, FL DynaFire.com INSPECTION AND TESTING FORM PER NFPA 72. Owner s Address: Owner's Phone Number:

Self Inspection Program

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

Checklist For Life Safety

Building Analytics and Compliance: How analytics can be used to aid in performancebased certifications. Bryant M. Kirkland Jr, PE, CCP, LEED AP

1. Are there any annual sprinkler head inspection forms available? No, there are none available at this time.

HIGH-RISE RETROFIT ORDINANCES - NO and NO

WEST VIRGINIA UNIVERSITY

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

COURSE SYLLABUS FIRE ALARM AND FIRE SUPPRESSION SYSTEMS CORRESPONDENCE COURSE

Fire Alarm Testing and Inspection Report

FIRE PROTECTION PROGRAM

Oklahoma. 265: Incorporated national codes and standards The following national codes and standards are incorporated by reference:

Revised March 2015 Fire Alarm Systems Verification. Schedule I(A) Services. *Manditory Site visit required*

Fire Protection System Contractors and Systems. Submission of the Application for a Water-Based Fire Protection Inspector

Brighton Area Fire Authority

Owner/Operator Guide for Successful Sprinkler and Fire Pump Systems

Fire & Life Safety Code Compliance. Common Safety Deficiencies and Tips for Compliance for Long Term Care and Skilled Nursing Facilities

MAINTENANCE AND INPSECTION OF FIRE PROTECTION SYSTEMS AND APPLIANCES

U626: Fire Alarm and Suppression System PMs. U626 Fire Alarm and Supp System PMs Ver 1.1

12/14/2013. Fire alarm and emergency power SPRINKLER HEAD

Top 8 Findings & SAFER Matrix for the 2017 ACE Summit & Expo

FIRE SAFETY PLAN. BUILDING NAME: Pathobiology / AHL BUILDING NUMBER: 089. DATE: 15-August-10 FPO #2

Life Safety Code Common Discepancies Course# LSC102. EZpdh.com All Rights Reserved

False Sense of Security???

Top (15) Life Safety Code Deficiencies and Tips for Compliance (10/01/2011 thru 02/22/2012)

SECTION : FIRE ALARM & DETECTION SYSTEMS

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

Balloting Version First Draft NFPA 101 Life Safety Code Proposed 2015 Edition

KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

AMENDMENTS TO THE BUILDING AND FIRE CODE FOR THE CITY AND COUNTY OF DENVER

Fire Sprinkler Plan Submittal Form

OWNER'S OPERATION AND MAINTENANCE MANUAL

Project Name: Project Address: Installer Name: Installer Address: Date of Inspection:

EXHIBIT D ATTACHMENT G - UNIT PRICING DMS-14/15-039B - SIMPLEXGRINNELL, LP FIRE SPRINKLER SYSTEM INSPECTIONS YEARS 1-5

Types of Detection. Fusible Link Detection - Most Common

Table OUT OF SERVICE. Building Fire Video 1/15/ Inspection, testing and maintenance. Standards Further Referenced by FCNYS

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Are there any policies regarding outlets that contain USB ports?

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

Agency for Health Care Administration

Automatic Fire Alarm Association Webinar On Inspection, Testing, And Maintenance Of Fire Alarm Systems

Balloting Version First Draft NFPA 101 Life Safety Code Proposed 2015 Edition

LIFE SAFETY TRAINING Nebraska Health Care Association Chris Moran November 1, 2017

FIRE AND SAFETY PROJECT REVIEW REPORT

Facilities Management

Agency for Health Care Administration

Transcription:

WHEA FSE inspections www.jfahern.com

FEC.02.03.05 Features of Fire Safety Buildings are protected from fire by a series of detection, notification and suppression devices Each feature of fire safety must be fully operational Each device must be tested to ensure it is functional and dependable The Joint Commission requires a working inventory of devices, so if one is not tested or fails it may be located REMINDER: the Joint Commission uses the 2000 edition of the Life Safety Code

EC.02.03.05 EP1 Supervisory Signal Devices A device that sends a signal back to the main fire alarm panel (e.g., fire pump running, loss of power to fire pump, fire pump room temperature problems, etc.) Must be tested quarterly

EC.02.03.05 EP2 Water Flow Switches These devices alarm when the flow of water is detected in the sprinkler system i.e., possibly a sprinkler head activated Must be tested quarterly Semi-annually if not seeking deemed status

EC.02.03.05 EP2 Valve Tamper Switches Monitors sprinkler zone valves; a signal is sent to main fire alarm panel if attempt to close Must be tested semiannually If a valve does not have a tamper switch, it must be locked in the open position

EC.02.03.05 - EP3 Detectors and Door Releasing Devices Includes duct/ heat/smoke detectors, manual pull stations, and magnetic door releasing devices. Must be tested annually

EC.02.03.05 EP5 Fire Notification Devices Includes audible devices, speakers and visible devices. Must be tested annually

EC.02.03.05 EP4 Fire Alarm Testing Inventory

EC.02.03.05 EP5 Fire Alarm Offsite Notification

EC.02.03.05 EP6 Fire Pump Weekly Run Test (No Flow) Purpose of test is to verify pump is in operating condition Pump needs to run for a minimum of ten minutes(water flow is not required)

EC.02.03.05 EP9 Main Drain Test Conducted to determine a change in the condition of water supply piping or control valves Must be conducted annually

EC.02.03.05 EP10 Fire Department Connections

EC.02.03.05 EP11R Fire Pump Annual Test Under Flow

EC.02.03.05 - EP12 5 Year Standpipe Test

EC.02.03.05 EP13 Kitchen Automatic Extinquishment Shuts off fuel source automatically. Connected to fire alarm panel Must be inspected every 6 months Actual discharge is not required K Type portable fire extinguisher

EC.02.03.05 EP14 Carbon Dioxide &other Gaseous Automatic Systems Must be inspected annually Actual discharge is not required

EC.02.03.05 EP15 and 16 Portable Fire Extinguishers Monthly Visible Inspection Accessible Fully charged Any Parts broken Correct type DO NOT COUNT DAYS, BUT ENSURE MONTHLY INSPECTION Annual Maintenance by a licensed Fire Protection service company

EC.02.03.05 Portable Fire Extinguishers Types

EC.02.03.05 Fire Extinguisher: Dating

EC.02.03.05 Portable Fire Extinguishers Types

EC.02.03.05 EP18 Fire Dampers Stops the passage of fire through ventilation ductwork Activated by fusible link Inspected and tested within one year of installation and every six years thereafter

EC.02.03.05 EP18 Smoke Dampers Stops the passage of smoke through ventilation ductwork Activated by external smoke detector Must be installed within 24 inches of smoke partitions Inspected and tested after one year of installation and then every six years

EC.02.03.05 EP19R Ventilation Shut Down Devices Stops the passage of smoke through ventilation ductwork Activated by external smoke detector Must be installed within 24 inches of smoke partitions Inspected and tested after one year of installation and then every six years

Duct Detector Testing Air Handler Shutdown

EC.02.03.05 EP20 Rolling Fire Doors Activated by fusible link Fusible link shall not be painted Must be tested annually

EC.02.03.05 EP25 Joint Commission Accreditation Documentation of maintenance, testing, and inspection activities for fire alarm and water-based fire protection systems includes the following: NFPA 25 NFPA72

EC.02.03.05 EP25 Joint Commission Accreditation Name of the activity Date of the activity Required frequency of the activity Name and contact information, including affiliation, of the person who performed the activity NFPA standard(s) referenced for the activity Results of the activity Report with Deficiency and follow up.