Addendum RINS HONEYWELL. SCANTRONIC / COOPER Input (Programmed as Fault) SCANTRONIC 9600 SCANTRONIC 9651

Similar documents
Installation Manual RINS1211-4

STERLING 10 Control Panel with Remote Keypads ICON and LCD INSTALLATION MANUAL

SDR-WEXT Wired Siren Installation Guide

Input Type: 42: Medical: This is a 24 Hr type input it will activate the external sounder and report a CID event 100.

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

AL600ULADA. NAC Power Extender. Installation Guide

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

THIS GUIDE SUPPORTS MATRIX 424 & 832 CONTROL PANELS

M550 and M600. Installation Instructions

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

System 800 Addressable Fire Detection & Alarm System

AL800ULADA. NAC Power Extender. Installation Guide

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

Matrix Installation Manual. Software Version 4. EN Security Grade 2 Environmental Class 2 RINS918-1

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

QA16 Addressable System

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

Booster Power Supply Manual

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

Changes for EN50131 BS8243 PD6662

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Model 4880 Status Output Display Module Manual

SECURIT 700L PLUS ENGINEERING MANUAL

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

MODEL ZA-8N EIGHT ZONE ANNUNCIATOR FOR ALL MONITORING APPLICATIONS OUTSTANDING FEATURES

Application, Installation, Operation & Maintenance Manual

KT-100 Door Controller

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

Installation Instructions 4 Zone Fire Panel

FEC400 Series. Installation Manual

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1

Installation Guide & User Manual

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

Saffire User & Installation Manual. IMPORTANT This manual should be left with the panel after installation.

D9412GV2/D7412GV2. Approved Applications Compliance Guide. Control Panels

EURO 46 APP. User Manual. Connect to your home or business from anywhere in the world. Software version 2.1 RINS1840-2

Wireless keypad RKB1. Data sheet. Device identification number:

M2500 Engine Controller Installation Manual

Interface Modules for SENTRI

CA60Plus. Installation manual

TS5160. Installation & User Guide. Compatible Equipment. CPA6 0M - Output Module Loudspeaker DC54/58 - Digital Communicators (Stand Alone Only)

Excel-EN Conventional Fire Control Panel

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Ohm Metrics. Instruction Manual. Continuous Workstation Monitors Model CM1600. T r a n s f o r m i n g T e c h n o l o g i e s, L L C

System Introduction. 1.1 Specifications S E C T I O N 1

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

WARNING FIRE DOOR CLOSING

Galaxy 2 Series. Installation Manual. Honeywell Security

MR-2602 Two Zone Fire Alarm Control Panel

Installation guide for J4 Junction Box for R4 AIS Transponder System

VAP304 PRO INSTALLATION & OPERATION MANUAL

Control Panel Engineering and Commissioning Instructions

WIRELESS DOOR/WINDOW CONTACT ACCESSORY (WHA3)

INSTALLATION GUIDE. For products. Gardtec 370 & 581

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Notification Appliance Circuit Module

TS700. Intruder Alarm Control Panel. Installation & Programming Instructions OPEN

Contents. Introduction... 2 Mains Safety... 2 Good Working Practice... 2

Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. American Gas Safety LLC 1 05/10/2016

APPLICATION NOTES. Stone Technologies Corporation Westrock Dr. #4 Austin, Texas OUT + + IN - + IN - + IN - + IN -

System Manual W A R N I N G. PC6O1O Software Version 2.1

General Routing Interface

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Technical Speci fications 220V AC 50Hz or 110V AC 60Hz Accessories operational voltage. 2x 12V / 7Ah sealed lead acid gel batteries

GSM PERIMETER & INTRUDER ALARM

Level 1 Physics, 2014

Addendum for STI-6406 with Dual Access Control

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

Long Range Radio Alarm Transmitter

Contents. Introduction... 2 Mains Safety... 2 Good Working Practice... 2

ECo8x Ness ECO8x AlARm CONtROl panel InstallatIon & programming manual Revision 1.5 A$15.00

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

Installation, Operating and Maintenance Manual

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

Installation Guide for models:

Model 17A00 Expansion Enclosure

Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. Rev: 03 Date:

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

NESS D8 CONTROL PANEL AND DIALLER

Intelligent Security & Fire Ltd

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

INSTALLATION MANUAL SECURIT 802 CONTROL PANEL

Installation Manual IMPORTANT. PC5020 Version 3.1 DLS-3 v1.3 and higher

Challenger Version 8 Programming Relays.

Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)

EVO192 v3.0 Fire and Burglary What s New

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

Combi B Alarm box. Mounting instructions

Technical Bulletin Bulletin Number: 2012_02 Released: 1 st May 2012

Transcription:

Addendum RINS16032 NEW EN GRADE 3 FEAURES Any Grade 3 Invincibell has an output on the PCB called FAUL, this is used to monitor the SAB back up battery. his output does not need to wired to Grade 2 panels. he Invincibell will do an active self test on the SAB back up battery every 24 hours. If the SAB back up battery fails it s self test, then the FAUL relay will open and notify the control panel of a Warning Device Fault. It may then be necessary to replace the SAB back up battery. he Invincibell siren trigger wire input must also be monitored to be compliant at Grade 3. On some control panels it may be necessary to connect a resistor between the control panel siren output and 0V or 12V. Refer to the full manual for Pyronix and Castle connections, for all other control panels please see the below diagrams that show the Grade 3 connections on various manufacturers control panels. Note: If using 2 Grade 3 Invincibells please do not parallel the bell trigger wire. Always use a separate output. trigger wires can be wired parallel. When wiring an Aritech AS 2003 3003 4003 the bell trigger wiring must be wired through a relay, as shown in Figure A on page 2. HONEYWELL OP OP FAUL SB SCANRONIC / COOPER NO C NC NO C NC FAUL SB rigger Monitor Resistor (4K7) amper/fault resistor values shown are 1K Alarm and 1K amper. hese amper/fault resistor values shown are 4K7 Alarm and 2K2 amper. hese SCANRONIC 9600 SCANRONIC 9651 SR SR 0V R FAUL SB rigger Monitor Resistor (4K7): 0V R FAUL SB rigger Monitor Resistor (1K): Brown, Black, Red

MENVIER ARIECH CD9503/CD15003 RIG SB 34 51 R HO HO FAUL SB 53 54 57 FAUL SB rigger Monitor Resistor (470Ω): Yellow, Violet, Brown rigger Monitor Resistor (4K7): AS 2003 3003 4003 S1 S2 amper RN # FAUL SB Figure A 12V 0V NC C NO Relay ZA 200. AS 2000, 3000, 4000 NOE: he SRB output needs to be programmed as he IN output needs to be programmed as SROBE SRB S IN S AUX amper RN # FAUL rigger Monitor Resistor (4K7): SB

EXECOM RISCO (GARDEC) OP OP FAUL SB rigger Monitor Resistor (470Ω): Yellow, Violet, Brown SAB AMP FAUL SB rigger Monitor Resistor (4K7): amper/fault resistor values shown are 4K7 Alarm and 2K2 amper. hese amper/fault resistor values shown are 6K8 Alarm and 4K7 amper. hese GUARDALL PX48i PYRONIX (PreVersion 9) COM SB NC NO RN FAUL SB PGM PGM FAUL SB rigger Monitor Resistor (10K): Brown, Black, Orange amper/fault resistor values shown are 4K7 Alarm and 4K7 amper. hese CASLE (PreVersion 9 EURO 46) CASLE (PreVersion 9 EURO 76, 162, 280) FAUL SB rigger Monitor Resistor (470Ω): Yellow, Violet, Brown FAUL SB rigger Monitor Resistor (10K): Brown, Black, Orange amper/fault resistor values shown are 4K7 Alarm and 2K2 amper. hese amper/fault resistor values shown are 4K7 Alarm and 2K2 amper. hese If you require any further assistance please contact Customer Support: 0845 6434 999 or 01709 535225. Hours: 8am 6:30pm. customer.support@pyronix.com. www.pyronix.com

INVINCI RIGGER MONIORING INSALLAION GUIDE MINIMUM RIGGER MONIORING VOLAGE = 1.6 VOLS MAXIMUM RIGGER MONIORING VOLAGE = 3 VOLS Step 1: Wire the Invincibell as shown in the Invincibell installation instructions, but leave the rigger wire disconnected. INVINCI (GRADE 3) FAUL SB CONROL PANEL Step 2: When the Invincibell is powered up make sure that the Invincibell amper Switch is in its open state. his will ensure that the rigger Monitor is disabled until the Invincibell amper Switch is closed. his open tamper state on initial power up will prevent the bell from making any noise, and it will ensure an easier installation. 1

Step 3: At the control panel measure the DC voltage between the 0 Volt Hold off connection, and the rigger output connection. If the measured DC voltage is 12 Volts or above, then fit a 1K resistor between the 0 Volt Hold off connection and the rigger output connection. Now move to SEP 4. If the measured DC voltage is 0 Volts then move straight to SEP 7. 13.0V CONROL PANEL RIGGER OUPU 0V OFF NEGAIVE 1 K CONROL PANEL RIGGER OUPU 0V OFF NEGAIVE Step 4: At the control panel measure the DC voltage across the 1K resistor which has been inserted between the 0 Volt Hold off connection and the rigger output connection. he measured DC voltage reading will be close to the readings shown in the table below. Step 5: APPROXIMAE MEASURED VOLAGE REQUIRED MONIORING RESISOR 6.8 Volts 470 ohms 4.5 Volts 1K 4.2 Volts 1K 3.4 Volts No resistor required 3.1 Volts No resistor required 2.3 Volts No resistor required 0 Volts See SEP 7 At the control panel remove the 1k resistor from the 0 Volt Hold off connection and the rigger output connection. Replace the 1k resistor with the chosen value of resistor from the table above. Insert and screw down the rigger wire into the control panel output connection. Make a final measurement of the DC Voltage at the Invincibell between the 0 Volt Hold off connection and the rigger output, the rigger Monitor voltage will read between 1.6 Volts and 3.0 Volts DC. 1.6V3.0V INVINCI 2

Step 6: Close the Invincibell case lid and amper Switch and the rigger Monitoring will be fully operational. Step 7: If 0 Volts is measured when following instruction number 3, then ONLY fit a 4k7 resistor between the control panel 12 Volt Hold off connection and the rigger output connection. he rigger wire can now be inserted and screwed down in the control panel rigger output connection. 0V CONROL PANEL RIGGER OUPU 0V OFF NEGAIVE 4 K 7 CONROL PANEL RIGGER OUPU OFF POSIIVE Most Panels fit within the table above if you have any doubts please contact technical support for assistance: elephone: 44(0)845 6434 999 (local rate) or 44(0)1709 535225 Opening Hours: 8:00am 6.30pm, Monday to Friday 3