THE WALL-MOUNT GAS/ELECTRIC Low NOx Certified Models

Similar documents
The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT NOx Certified Models

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

THE WALL-MOUNT TM SIX TON AIR CONDITIONER

THE WALL-MOUNT Quiet Climate A/C 10.0 EER

WALL-MOUNT HEAT PUMPS - (60HZ)

GREEN REFRIGERANT R-410A

THE WALL-MOUNT QUIET CLIMATE HEAT PUMPS

Green Refrigerant. THE WALL-MOUNT STEP CAPACITY AIR CONDITIONERS Integrated Part Load Value (IPLV) Efficiency Up To 15.3 BTU/WATT. Engineered Features

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

THE WALL-MOUNT HEAT PUMPS EER, (60HZ)

Q-TEC QC-Series Chilled Water Air Conditioner

THE WALL-MOUNT AIR CONDITIONERS (50HZ)

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Q-TEC Q24A-Q60A Air Conditioners

Q-Tec TM QC-Series Chilled Water Air Conditioner

THE WALL-MOUNT 6-TON AIR CONDITIONERS

Q-TEC Q24H3-Q60H3 Air-to-Air Heat Pump 10 EER Units

BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

GREEN REFRIGERANT R-410A

Q/Tec TM QH-Series 2 Air-to-Air Heat Pumps

BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide

The Wall-Mount Variable Capacity Environmental Control Units. Green Refrigerant

Q/Tec TM QA-Series Air Conditioners

Wall Mounted Air Conditioners with Gas Heat Models AVGA

WARNING READ ALL INSTRUCTIONS CAREFULLY BEFORE BEGINNING THE INSTALLATION.

GREEN REFRIGERANT R-410A

BARD MANUFACTURING COMPANY, INC. W18AA-W72AB

WARNING READ ALL INSTRUCTIONS CAREFULLY BEFORE BEGINNING THE INSTALLATION.

GREEN REFRIGERANT R-410A

DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit

Q/Tec TM QW-Series Water-to-Air Heat Pumps

WG242DA WG242DB WG243DC WG302DA WG302DB WG303DC WG362DA WG362DB WG363DC WG423DA WG423DB WG424DC WG482DA WG482DB WG483DC WG602DA WG602DB WG603DC

DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit

RGE 13 A T - 1 A

48PGD/E/F/L/M/N PG20-28

13 GEP A L P - 1 A

Installation Instructions

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121

I-TEC I30A1D-I60A1D 2-Stage Compressor High Efficiency Air Source Air Conditioners w/dehumidification

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA

1.5 to 3 Ton 208V to 460V 60hz Air Conditioner Specifications

Product Guide. Wallmount. Air Conditioners & Heat Pumps

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

HEAT EXCHANGER Aluminized serpentine clamshell heat exchanger provides corrosion resistance for longer life and efficient heat transfer.

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners

Classic 13 Heat Pumps High Efficiency Vertical Packaged Heat Pumps Models HVPA and HVPSA

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

THE MULTI-TEC WALL-MOUNT AIR CONDITIONERS 10 EER (50 HZ) WITH LOGIC BOARD

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS W12A2-A W12A1-K

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

48TF GAS HEATING/ ELECTRIC COOLING UNITS

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

Green Refrigerant. MULTI-TEC WALL-MOUNT Features All Models. Standard Features All Models

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

48TM GAS HEATING/ELECTRIC COOLING UNITS

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

ComPac I & ComPac II 1 to 6 Ton Vertical Wall Mount Air Conditioners Models AVP

GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

SUBMITTAL SCHEDULE & DATA

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST

50TM COMBINATION HEATING/COOLING UNITS

SKYPAK II Heating & Cooling Self Contained Packages

RG7D 1-Stage Heat Series

Product Data. Fig. 1 - Unit 50VR -A

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMP WH184 WH242

INSTALLATION INSTRUCTIONS

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

GEOTEC GV Series High Efficiency Geothermal/Water Source Packaged Step-Capacity Heat Pump R-410A

50TM TFF COMBINATION HEATING/COOLING UNITS

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

PGB SERIES 3thru5Ton 10 SEER CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series

Commercial High-Efficiency Condensing Units

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

13 SEER CONDENSING UNITS

GreenPac & GreenPac HGR Air Conditioners Single stage models AVPA and HVEA and 2-stage models HVESA

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

62DA,DB,DC,DD,DE,DF07-38

PAJ3. Product Specifications

TECHNICAL SPECIFICATIONS

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WGERV-A3A WGERV-C3A WGERV-A5A WGERV-C5A WGSERV-A5 WGSERV-C5

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

Submittal Summary Page

Transcription:

Models: W24G3 to WG3 Up to 1.5 EER 26, to 57,5 BTUH Cooling Capacity 37, to 74, BTUH Heating Capacity The Bard Wall-Mount Electric Air Conditioner with gas fired heating is a self contained energy efficient system which is designed to offer maximum indoor comfort at a minimal cost without using valuable indoor floor space or outside ground space. This unit is the ideal product for versatile applications such as: new construction, modular offices, school modernization, portable structures, correctional facilities, retail stores or other commercial applications. Factory or field installed accessories are available to meet specific job requirements. Engineered Features Air Conditioner Compressor: Scroll compressors are used on all models and no crankcase heaters are required. R-41A Refrigerant: Designed with R-41A (HFC) non-ozone depleting refrigerant in compliance with the Montreal protocol and 21 EPA requirements. Liquid Line Filter Drier: Protects system against moisture. Aluminum Finned Copper Coils: Grooved tubing and enhanced louvered fin for maximum heat transfer and energy efficiency. High & Low Pressure Switches are Auto- Reset: Built-in lockout circuit resets from the room thermostat. Provides commercial quality protection to the compressor. Compressor Control Module: Standard on all units. Built-in off-delay timer adjustable from 3 seconds to 5 minutes. 2-minute on-delay if power interrupt. 12-second bypass for low pressure control, and both soft and manual lockouts for high and low pressure controls. Alarm output for alarm relay. Phase Rotation Monitor: Standard on all 3 phase scroll compressors. Protects against reverse rotation if power supply is not properly connected. Twin Blowers: Move air quietly. All models feature multispeed blower motors providing airflow adjustment for high and low static operation. Electrical Components: Are easily accessible for routine inspection and maintenance through a right side service panel opening. Features a lockable, hinged access cover to the circuit breaker. THE WALL-MOUNT GAS/ELECTRIC Low NOx Certified Models Pre-Painted 2 Gauge Zinc Coated Steel Cabinet: Cleaned, rinsed, sealed and dried before the polyurethane primer is applied. The cabinet is handsomely finished with a baked on textured enamel, which allows it to withstand hours of salt spray tests per ASTM B117-3. 16 Gauge Zinc Coated Unit Base. Heat Exchanger: Heavy duty 18-gauge stainless steel tubular heat exchanger. Mechanically joined construction. Ten-year warranty. In-Shot Burners: Advanced burner design, quiet operation. NOx models can be converted to LP gas. High altitude kits available. Built-in Circuit Breakers: Standard on all single (23/28 volt) and three phase (23/28 volt) equipment. Toggle disconnects are standard on all three phase (4 volt) equipment. Integrated DSI Control: Direct spark ignition control and remote sensor delivers smooth, proven ignition sequence. Timed blower control and diagnostics are also features of integrated control. Gas Controls: Honeywell gas valve and burner orifices are factory standard for natural gas. Field convertible to LP gas with certified conversion kit. Filter Service Door: Separate service door provides easy access for filter change. Condenser Fan and Motor Shroud Assembly: Slides out for easy access. Green Refrigerant R-41A Air Filters: Two-inch pleated air filters are standard equipment. Optional 1-inch washable filter available. Factory or field installed. Barometric Fresh Air Damper: Standard on all units. Allows up to 25% outside fresh air. Ventilation Options: Several ventilation options are available and can be factory or field installed. Slope Top: Standard feature for water run-off. Top Rain Flashing: Standard feature on all models. Full Length Mounting Brackets: Built into cabinet for improved appearance and easy installation. NOTE: Bottom mounting bracket included to assist in installation. Complies with efficiency requirements of ANSI/ASHRAE/IESNA 9.1-213. Certified to ANSI/ARI Standard 39-23 for SPVU (Single Package Vertical Units). Intertek ETL Listed to Standard for Safety Heating and Cooling Equipment ANSI/UL 1995/CSA 22.2 No. 236-5, Fourth Edition. Intertek ETL Listed to Standard for Gas-Fired Central Furnaces ANSI Z21.47-26, CSA 2.3-26 Fifth Edition, Addenda A dated 1-1-27, Addenda B dated 6-1-28. Commercial Product - Not intended for Residential application. Page 1 of 14

Specifications 2 Ton through 3 Ton MODELS W24G3-A W24G3-B W24G3-C W3G3-A W3G3-B W3G3-C W36G3-A W36G3-B W36G3-C Electrical Rating Hz 23/28-1 23/28-3 4-3 23/28-1 23/28-3 4-3 23/28-1 23/28-3 4-3 Operating Voltage Range 197-253 187-253 414-56 197-253 187-253 414-56 197-253 187-253 414-56 Minimum Circuit Ampacity 21 16 1 23 17 11 28 22 11 *Field Wire Size/ 1 12 14 1 12 14 8 1 14 Ground Wire Size 1 12 14 1 12 14 1 1 14 ** Delay Fuse - Max. 3 25 15 35 25 15 45 35 15 Compressor Voltage 23/28 23/28 4 23/28 23/28 4 23/28 23/28 4 Rated Load Amps 9.9/1.9 6.4/7.1 3.9 11.8/12.9 7.5/8.2 4.7 15.3/16.7 7.8/8.8 5.1 Branch Circuit Selection Current 12.8 8.3 5.1 14.1 9 5.6 17.9 1.5 6 Lock Rotor Amps 64/64 58/58 28 77/77 71/71 38 112/112 73/73 44 Compressor Type Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Fan Motor & Condenser Fan Motor--HP--RPM-SPD 1/5-15-1 1/5-15-1 1/5-15-1 1/5-15-1 1/5-15-1 1/5-15-1 1/5-15-1 1/5-15-1 1/5-15-1 Fan Motor--Amps 1.5 1.5.8 1.5 1.5.8 1.5 1.5.8 Fan--DIA/CFM 2" - 24 2" - 24 2" - 24 2" - 24 2" - 24 2" - 24 2" - 24 2" - 24 2" - 24 Blower Motor & Evap. Blower Motor--HP-RPM-SPD 1/4-95-3 1/4-95-3 1/4-95-34 1/3-1-3 1/3-1-3 1/3-1-3 1/3-1-3 1/3-1-3 1/3-1-3 Blower Motor--Amps 1.8 1.8.8 2.2 2.2 1.1 2.2 2.2 1.1 CFM Cooling & E.S.P. -.15 -.15 -.15 -.35 -.35 -.35 1 -.25 1 -.25 1 -.25 Filter Size 2 x 25 x 2 2 x 25 x 2 2 x 25 x 2 2 x 25 x 2 2 x 25 x 2 2 x 25 x 2 2 x 25 x 2 2 x 25 x 2 2 x 25 x 2 Shipping Weight --LBS. 5 5 5 53 53 53 53 53 53 Specifications 3.5 Ton through 5 Ton MODELS W42G3-A W42G3-B W42G3-C W48G3-A W48G3-B W48G3-C WG3-A WG3-B WG3-C Electrical Rating Hz 23/28-1 23/28-3 4-3 23/28-1 23/28-3 4-3 23/28-1 23/28-3 4-3 Operating Voltage Range 197-253 187-253 414-56 197-253 187-253 414-56 197-253 187-253 414-56 Minimum Circuit Ampacity 32 23 12 38 27 13 4 28 14 *Field Wire Size/ 8 8 14 8 8 14 8 8 12 Ground Wire Size 1 1 14 1 1 14 1 1 12 ** Delay Fuse - Max. 5 35 15 5 4 2 4 2 Compressor Voltage 23/28 23/28 4 23/28 23/28 4 23/28 23/28 4 Rated Load Amps 15.5/17.5 1.2/11.5 4.8 19.5/22.2 12.1/13.8 5.9 21.6/24.7 12.8/14.7 6.4 Branch Circuit Selection Current 19.9 13.1 6.1 22.2 18.6 9.5 26.3 15.6 7.8 Lock Rotor Amps 19/19 83/83 41 135/135 98/98 55 134/134 11/11 52 Compressor Type Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Scroll Fan Motor & Condenser Fan Motor--HP--RPM-SPD 1/3-825- 2 1/3-825-2 1/3-825-1 1/3-825-2 1/3-825-2 1/3-825-1 1/3-825-2 1/3-825-2 1/3-825-1 Fan Motor--Amps 2.5 2.5 1.3 2.5 2.5 1.3 2.5 2.5 1.3 Fan--DIA/CFM 24" - 35 24" - 35 24" - 35 24" - 35 24" - 35 24" - 35 24" - 35 24" - 35 24" - 35 Blower Motor & Evap. Blower Motor--HP-RPM-SPD 1/2-15-3 1/2-15-3 1/2-15-3 1/2-15-3 1/2-15-3 1/2-15-3 1/2-15-3 1/2-15-3 1/2-15-3 Blower Motor--Amps 3.4 3.4 1.5 3.4 3.4 1.5 3.4 3.4 1.5 CFM Cooling & E.S.P. 13 -.35 13 -.35 13 -.35 155 -.38 155 -.38 155 -.38 1 -.3 1 -.3 1 -.3 Filter Size 2 x 3 x 2 2 x 3 x 2 2 x 3 x 2 2 x 3 x 2 2 x 3 x 2 2 x 3 x 2 2 x 3 x 2 2 x 3 x 2 2 x 3 x 2 Shipping Weight --LBS. 71 71 71 725 725 725 *Based on C copper wire. All wiring must conform to the National Electrical Code and all local codes. **Maximum time delay fuse or HACR type circuit breaker. Page 2 of 14

Cooling System Capacity, Efficiency & Airflow Ratings and Available Heating Inputs Models W24G3 W3G3 W36G3 W42G3 W48G3 WG3 Cooling Capacity BTUH 26, 32, 35, 42, 48, 57,5 EER k 1. 1. 1.2 1. 1.5 1.1 Rated CFM 1 13 155 1 Acceptable Airflow Range 6-92 85-115 935-12 13-15 12-1 134-191 9, 9, 9, 125, 125, 125, Available Heating Inputs l 68, 68, 68,,,, 45, 45, 45,,,, Capacity is certified in accordance with ANSI/ARI Standard 39-23. EER = Energy Efficiency Ratio and is certified in accordance with ARI Standard 39-23. All ratings based on fresh air intake being % closed (no outside air introduction). Any one of the heating inputs shown is available for each basic cooling model as indicated. Each input can be field derated 1% from factory standard and main burner orifices are included with each unit to accomplish this. See table below for additional information. Heating System Capacity, Efficiency, Derate & Airflow Ratings Indoor Blower Performance W24G cooling airflow is rated CFM @.15 ESP, and wet coil range is - 91 CFM. See Heating Airflow Ratings Chart for heating details. 9, BTU Input.1 82 12 1.2 95 7 12 11.3 8 112.4 79 13.5 91 71. Factory Standard Factory Standard Factory Standard Input 9, 68, 45, Output 74, 55,5 37, Thermal Efficiency (T.E.) 82. 82. 82. Temp. Rise Range 5-4 - 25-55 Mid-Rise Range Airflow 14 925 83 Acceptable Airflow Range 845-135 73-12 61-133 Heating ratings certified in accordance with ANSI Z21.47-26. Heating System Capacity, Efficiency, Derate & Airflow Ratings Factory Standard Factory Standard Input 9, 68, Output 74, 56, Thermal Efficiency (T.E.) 82. 82. Temp. Rise Range 4-3 - Mid-Rise Range Airflow 123 1135 Acceptable Airflow Range 9-1 85-1 Heating ratings certified in accordance with ANSI Z21.47-26. W3G cooling airflow is rated CFM @.35 ESP, and wet coil range is 8-115 CFM. See Heating Airflow Ratings Chart for heating details. 9, BTU Input.1 12 1.2 11 95 13 12 11.3 1 8 129 112 94.4 115 99 119 13.5 15 91 19 95. 94 9 W24G, W3G, W36G W42G, W48G, WG Factory Connected Speeds SPEED 68, BTU Input.1 82 12 1 8.2 95 7 12 11.3 8 112 91.4 79 13.5 91 71 95. 45, BTU Input.1 82 12 1 8.2 95 7 12 11 81.3 8 112 91.4 79 13 8.5 91 71 95 7. 84 Voltage adjustment - Reduce airflow by CFM for 28 Volt Dehumidification coil adjustment - Reduce airflow by 35 CFM for dehumidification coil installed Top outlet adjustment - Increase airflow by 5 CFM for top outlet models SG-3, RG-3, non-ducted application adjustment - Reduce airflow by CFM for SG-3 and RG-3 installations 68, BTU Input.1 12 1.2 11 95 12 11.3 1 8 112 94.4 115 99 119 13 8.5 15 91 19 95 7. 94 9 84 45, BTU Input.1 12 1.2 11 95 12 11.3 1 8 129 112 94.4 115 99 119 13 8.5 15 91 19 95 7. 94 9 84 6 Voltage adjustment - Reduce airflow by CFM for 28 Volt Dehumidification coil adjustment - Reduce airflow by 35 CFM for dehumidification coil installed Top outlet adjustment - Increase airflow by 5 CFM for top outlet models SG-3, RG-3, non-ducted application adjustment - Reduce airflow by CFM for SG-3 and RG-3 installations Page 3 of 14

Indoor Blower Performance W36G cooling airflow is rated 1 CFM @.25 ESP, and wet coil range is 94-125 CFM. See Heating Airflow Ratings Chart for heating details. 9, BTU Input.1 122 12 1.2 11 95 13 12 11.3 125 1 129 112 94.4 115 99 119 13.5 15 19 95. 94 9 68, BTU Input.1 122 12 1.2 11 95 12 11.3 125 1 112 94.4 115 99 119 13 8.5 15 19 95 7. 94 9 84 45, BTU Input.1 122 12 1.2 11 95 12 11.3 125 1 129 112 94.4 115 99 119 13 8.5 15 19 95 7. 94 9 84 6 Voltage adjustment - Reduce airflow by CFM for 28 Volt Dehumidification coil adjustment - Reduce airflow by 35 CFM for dehumidification coil installed Top outlet adjustment - Increase airflow by 5 CFM for top outlet models SG-3, RG-3, non-ducted application adjustment - Reduce airflow by CFM for SG-3 and RG-3 installations Factory Connected Speeds 9, BTU Input.1 15 11 163 123.2 149 19 15 11.3 144 1 151 114.4 153 133 172 139 12.5 144 121 161 129. 132 14 11 SPEED W42G cooling airflow is rated 13 CFM @.35 ESP, and wet coil range is 13-14 CFM. See Heating Airflow Ratings Chart for heating details. 68, BTU Input.1 1 12 16 12.2 153 119 161 121.3 14 112 15 119.4 13 1 144 1.5 149 12 16 134 9. 13 153 123 Voltage adjustment - Reduce airflow by 13 CFM for 28 Volt Dehumidification coil adjustment - Reduce airflow by 35 CFM for dehumidification coil installed Top outlet adjustment - Increase airflow by CFM for top outlet models SG-3, RG-3, non-ducted application adjustment - Reduce airflow by 1 CFM for SG-5 and RG-5 installations W48G cooling airflow is rated 155 CFM @.2 ESP, and wet coil range is 125-17 CFM. See Heating Airflow Ratings Chart for heating details. 9, BTU Input.1 15 163 123.2 17 149 15 11.3 163 144 151 114.4 153 133 172 139 12.5 144 121 161 129. 132 14 11 68, BTU Input.1 1 16 12.2 15 153 161 121.3 16 14 15 119.4 15 13 144 1.5 149 12 16 134 9. 13 153 123 Voltage adjustment - Reduce airflow by 13 CFM for 28 Volt Dehumidification coil adjustment - Reduce airflow by 35 CFM for dehumidification coil installed Top outlet adjustment - Increase airflow by CFM for top outlet models SG-3, RG-3, non-ducted application adjustment - Reduce airflow by 1 CFM for SG-5 and RG-5 installations WG cooling airflow is rated 1 CFM @.3 ESP, and wet coil range is 13-185 CFM. See Heating Airflow Ratings Chart for heating details. 9, BTU Input.1 18 15 163 123.2 17 149 15 11.3 163 144 151 114.4 153 133 172 139 12.5 144 161 129. 132 14 11 68, BTU Input.1 191 1 16 12.2 15 153 161 121.3 16 14 15 119.4 15 13 144 1.5 149 16 134 9. 13 153 123 Voltage adjustment - Reduce airflow by 13 CFM for 28 Volt Dehumidification coil adjustment - Reduce airflow by 35 CFM for dehumidification coil installed Top outlet adjustment - Increase airflow by CFM for top outlet models SG-3, RG-3, non-ducted application adjustment - Reduce airflow by 1 CFM for SG-5 and RG-5 installations Page 4 of 14

Important Information Concerning Altitude Impact on Heating Input Ratings Heating input, and thus heating output, decreases with altitude. No orifice change is required up to 6, feet elevation and derate occurs naturally due to altitude impact. Natural gas models may require orifice change based on BTU content of gas. See Natural Gas Orifice and Altitude Tables on next page for details. For Propane Gas see the Propane Gas Conversion Table below. Above 6, feet elevation orifice changes are required, and capacity reductions are a function of altitude impact and orifice change. Pressure switch change is required above 6, feet elevation. For Natural Gas see the Orifice and Altitude Tables on next page. For Propane Gas see the Propane Gas Conversion Table below. NATURAL GAS DERATE CAPACITIES W**G Rated Input Sea Level 2 3 4 5 9 1, 68, 68,,34 63,1 61,2 59,4 58,32 56,9 56,1 55, 54,45 53,4 9, 9, 87,12 84,24 81,3 79,2 77,7,9 74,8 73,44 72,54 71,2 PROPANE (LP) DERATE CAPACITIES W**G Rated Input Sea Level 2 3 4 5 9 1, 68, 68, 66,42,8,34 64,2 63,72 62,64 61,2 59,4 57,24 54,54 9, 9, 88,5 87,84 87,12 85,6 84,9 83,52 81,3 79,2 76,32 72,72 Gas Pressure W.C. Minimum permissible gas supply pressure for purpose of input adjustment: Natural 4.5 LP 11. Maximum permissible gas supply pressure for purpose of input adjustment: Natural 11. LP 13. Manifold Pressure: Natural 3.5 LP 1. Propane Gas Conversion Kits -- Fits All WG-Series Models PROPANE (LP) GAS -- Use Gas Conversion Kits As Indicated MODELS Propane Gas Conversion Kit Use WGCK-1 Use WGCK-2 W24G W3G W36G Factory Standard Input 22,5-22, BTU Per Burner Gas Heat Value BTU/Cu. Ft. Up to Feet Install Orifice 1 to Feet Requires Pressure Switch Change and Orifice as Shown 1 to 1, Feet Requires Pressure Switch Change and Orifice as Shown 25 1.45 1.45 1.4 Pressure Switch Standard (.55) Pressure Switch (.42) Included in Conversion Kit PROPANE (LP) GAS -- Use Gas Conversion Kits As Indicated MODELS Propane Gas Conversion Kit Use WGCK-1 Use WGCK-2 W42G W48G WG Factory Standard Input 22,5-22, BTU Per Burner Gas Heat Value BTU/Cu. Ft. Up to Feet Install Orifice 1 to Feet Requires Pressure Switch Change and Orifice as Shown 1 to 1, Feet Requires Pressure Switch Change and Orifice as Shown 25 1.45 1.45 1.4 Pressure Switch Standard (.55) Pressure Switch (.42) Included in Conversion Kit All orifice sizes shown are millimeters (mm). Page 5 of 14

Natural Gas Orifice and Altitude Tables NATURAL GAS -- W24G, W3G, W36G Models Factory Standard Input 22,5 to 22, BTU Per Burner W24G W3G W36G Gas Heat* Value BTU/Cu. Ft. Up to Feet No Changes Except For BTU Content 1 to Feet Requires Pressure Switch Change and Orifice Change Based on BTU Content 1 to 1, Feet Requires Pressure Switch Change and Orifice Change Basesd on BTU Content -749 2. 2. 2. -799 2. 2. 2.5-849 2. 2.5 2.45 85-899 2.5 2.4 2.35 9-949 2.45 2.35 (2.3) 95-999 2.35 (2.3) 2.25-149** (2.3) 2.25 2.2 15-1 2.25 2.2 2.15 Pressure Switch Standard (.55) Order 862-189 High Altitude Pressure Switch Kit (.42) (2.3) is the standard factory installed orifice size. All other orifice sizes shown are available as individual items, see orifice chart below for part numbers. * At standard conditions: 3. Mercury, F, Saturated,. Specific Gravity ** All Natural Gas factory orifice sizing and standard input ratings based on nominal 125 BTU per cubic foot gas and sea level conditions. Optional 1% Field Converted Derate 22,5 BTU Per Burner W42G W48G WG Gas Heat* Value BTU/Cu. Ft. Up to Feet No Changes Except For BTU Content 1 to Feet Requires Pressure Switch Change and Orifice Change Based on BTU Content 1 to 1, Feet Requires Pressure Switch Change and Orifice Change Basesd on BTU Content -749 2. 2. 2. -799 2. 2. 2.5-849 2. 2.5 2.45 85-899 2.5 2.45 2.4 9-949 2.4 2.35 [2.3] 95-999 2.35 [2.3] 2.25-149** [2.3] 2.25 2.2 15-1 2.25 2.25 2.2 Pressure Switch Standard (.55) Order 862-189 High Altitude Pressure Switch Kit (.42) [2.3] is the standard factory installed orifice size. All other orifice sizes shown are available as individual items, see orifice chart below for part numbers. * At standard conditions: 3. Mercury, F, Saturated,. Specific Gravity ** All Natural Gas factory orifice sizing and standard input ratings based on nominal 125 BTU per cubic foot gas and sea level conditions. Bard Part No. Orifice Size (mm) Orifice Diameter 91-92 2.1.826 91-88 2.15.846 91-87 2.2.866 91-86 2.25.885 91-82 2.3.95 91-85 2.35.925 91-79 2.4.945 91-84 2.45.964 91-93 2.5.984 91-94 2..124 91-95 2..163 91-96 2..182 91-97 2..112 91-98 2.9.1142 No. of Orifices Required Based on Unit Input Rating 45, (2) 68, (3) 9, (4) All orifice sizes shown are in millimeters (mm). Page 6 of 14

Ventilation System Packages Bard Wall-Mounts are designed to provide optional ventilation packages to meet all of your ventilation and indoor air quality requirements. All units are equipped with a barometric fresh air damper as the standard ventilation package. All ventilation packages can be built-in at the factory, or field-installed at a later date. BAROMETRIC FRESH AIR DAMPER - WGBFAD STANDARD The barometric fresh air damper is a standard feature on all models. It is installed on the inside of the service door and allows outside ventilation air, up to 25% of the total airflow rating of the unit, to be introduced through the air inlet openings and to be mixed with the conditioned air. The damper opens during blower operation and closes when the blower is off. Adjustable blade stops allow different amounts of outside air to be introduced into the building and can be easily locked closed if required. BAROMETRIC FRESH AIR DAMPER BLANK OFF PLATE - WGBOP OPTIONAL A blank off plate is installed on the inside of the service door. It covers the air inlet openings which restricts any outside air from entering the unit. The blank off plate should be utilized in applications where outside air is not required to be mixed with the conditioned air. MOTORIZED FRESH AIR DAMPER - WGMFAD OPTIONAL The motorized fresh air damper is internally mounted behind the service door and allows outside ventilation air, up to 25% of the total airflow rating of the unit, to be introduced through the air inlet openings and to be mixed with the conditioned air. The two position damper can be fully open or closed. The damper blade is powered open by a 24VAC motor with spring return on power loss. The damper can be controlled by indoor blower operation or can be field connected to be managed based on building occupancy. MOTORIZED FRESH AIR DAMPER NOTE: The above vent systems are intake only without built-in exhaust capability. Building will likely require separate field installed barometric relief or mechanical exhaust elsewhere within the conditioned space. Balancing dampers in the return air grille may be required to achieve specified amount of outdoor air intake. COMMERCIAL ROOM VENTILATOR - WGCRV OPTIONAL The built-in commercial room ventilator is internally mounted behind the service door and allows outside ventilation air, up to 5% of the total airflow rating of the unit, to be introduced through the air inlet openings. It includes a built-in exhaust air damper. The commercial room ventilator (WGCRV) is a simple and innovative approach to improving the indoor air quality by providing fresh air intake and exhaust capability through the WGCRV. The damper can be easily adjusted to control the amount of fresh air supplied into the building. The WGCRV can be controlled by indoor blower operation or field controlled based on room occupancy. Complies with ANSI/ASHRAE Standard 62.1 Ventilation for Acceptable Indoor Air Quality. COMMERCIAL ROOM VENTILATOR Two Models Available: WGCRVS - spring return on power loss or deactivation WGCRVP - power return (will not close on power loss) ECONOMIZER - WGJIFM OPTIONAL The built-in economizer system is internally mounted behind the service door and allows outdoor air to be introduced through the air inlet openings. The amount of outdoor air varies in response to the system controls and settings defined by the end user. It includes a built-in exhaust air damper. The economizer is designed to provide free cooling when outside air conditions are cool and dry enough to satisfy cooling requirements without running the compressor. This in turn provides lower operating costs, while extending the life of the compressor. ECONOMIZER Standard Features: One Piece Construction - Easy to install with no mechanical linkage adjustment required. Exhaust Air Damper - Built in with positive closed position. Provides exhaust air capability to prevent pressurization of tight buildings. Actuator Motor - 24 volt, power open, spring return with built in torque limiting switch. Proportioning Type Control - for maximum free cooling economy and comfort. Moisture Eliminator & Prefilter - permanent, washable aluminum construction. Enthalpy Control - adjustable to monitor outdoor temperature and humidity. Honeywell JADE electronic economizer module with precision settings and diagnostics. Mixed Air Sensor - to monitor outside and return air to automatically modulate damper position. WALL-MOUNT ENERGY RECOVERY VENTILATOR - WGERV OPTIONAL The wall-mount energy recovery ventilator (WGERV) is a highly innovative approach to address indoor air quality ventilation requirements as established by ANSI/ASHRAE Standard 62.1. The WGERV allows up to 45 CFM (depending upon speed setting) of fresh air and exhaust through the unit while maintaining superior indoor comfort and humidity levels. In most cases this can be accomplished without increasing equipment sizing or operating costs. Heat transfer efficiency is up to 74% during summer and % during winter conditions. ENERGY RECOVERY VENTILATOR The WGERV consists of a unique rotary energy recovery cassette that provides effective sensible and latent heat transfer capabilities during summer and winter conditions. Various control schemes are addressed including limiting ventilation during building occupancy only. The WGERV is designed to be internally mounted behind the service door in the WG Gas/Electric units. It can be builtin at the factory or field installed as an option. WGERV can be independently adjusted for intake and exhaust rates. NOTE: See Page 8 for WGERV Performance Data and Page 9 for WGCRV Performance Data Page 7 of 14

Energy Recovery Ventilator Performance Data Ambient O.D. DB/ WB 15 95 9 85 APPLICATION DATA WGERV-*3 SUMMER COOLING PERFORMANCE (INDOOR DESIGN CONDITIONS DB/62 WB) VENTILATION RATE -- 45CFM High Speed (Black) 72% EFFICIENCY VENTILATION RATE -- 3 CFM Medium Speed (Blue) 73% EFFICIENCY VENTILATION RATE -- 2 CFM Low Speed (Red) 74% EFFICIENCY F VLT VLS VLL HRT HRS HRL VLT VLS VLL HRT HRS HRL VLT VLS VLL HRT HRS HRL 214 145 145 315 214 3159 214 3159 214 3159 214 48 48 214 4252 4252 145 145 145 48 48 48 48 48 6884 1944 9314 22 218 11744 2632 141 562 2673 165 7492 1935 9922 1822 15455 1498 1498 226 1498 1498 1498 4957 259 5661 12884 81 81 81 81 81 7293 7293 7293 7293 7293 5834 5834 5834 5834 5834 4376 4376 4376 4376 4376 2917 2917 2917 2917 2917 1459 1459 1489 1459 4133 972 972 972 972 972 48 48 48 48 48 324 324 324 324 324 4284 9883 6713 6713 6713 6713 6713 5594 5594 5594 5594 5594 4476 4476 4476 4476 4476 3357 3357 3357 3357 3357 2238 2238 2238 2238 2238 1119 1119 1119 1119 31 15455 8893 6998 6998 6998 6998 6998 5249 5249 5249 5249 5249 3499 3499 3499 3499 3499 1 1 1 1 13932 67 145 1156 999 999 999 999 999 999 999 1591 79 166 1897 12884 7414 7293 7293 11614 5591 121 19 124 5796 126 1454 9883 5687 5594 5594 891 4289 93 22745 15455 8893 6998 6998 15746 8456 1895 25974 1156 17982 97 2164 18961 12884 7414 5834 5834 13127 5 15 196 48 48 138 738 1638 14545 9883 5687 4476 4476 548 1212 22745 15455 8893 5249 5249 17496 126 3645 25974 1156 199 115 4162 18961 12884 7414 4376 4376 14585 858 338 196 882 315 14545 9883 5687 3357 3357 11189 27 2331 22745 15455 8893 3499 3499 15455 8893 361 1 8893 361 19246 11956 5394 135 7144 1312 25974 1156 1156 3496 21978 133 61 151 8158 1498 18961 12884 7414 2917 2917 12884 7414 2552 1459 7414 2552 144 9967 4497 11425 5955 194 196 324 324 2646 2646 16632 1332 4662 11844 6174 1134 14545 9883 5687 2238 2238 9883 5687 1958 1119 1238 7646 345 87 4569 839 4252 8893 361 1156 3496 1156 3496 7414 2552 2646 5687 1958 5687 1958 Ambient O.D. DB/ WB 15 95 9 85 APPLICATION DATA WGERV-*5 SUMMER COOLING PERFORMANCE (INDOOR DESIGN CONDITIONS DB/62 WB) VENTILATION RATE -- 45CFM High Speed (Black) % EFFICIENCY VENTILATION RATE -- 3 CFM Medium Speed (Blue) 62% EFFICIENCY VENTILATION RATE -- 2 CFM Low Speed (Red) 64% EFFICIENCY F VLT VLS VLL HRT HRS HRL VLT VLS VLL HRT HRS HRL VLT VLS VLL HRT HRS HRL 214 145 145 315 214 3159 214 3159 214 3159 214 48 48 214 4252 4252 145 145 145 48 48 48 48 48 6884 1944 9314 22 218 11744 2632 141 562 2673 165 7492 1935 9922 1822 12879 5832 5832 5832 5832 5832 4374 4374 4374 4374 4374 2916 2916 2916 2916 2916 1458 1458 1458 1458 4131 259 5661 1942 7433 7433 7433 7433 7433 6194 6194 6194 6194 6194 4955 4955 4955 4955 4955 3716 3716 3716 3716 3716 2478 2478 2478 2478 2478 1239 1239 1239 1239 351 972 972 972 972 972 48 48 48 48 48 324 324 324 324 324 4284 8548 56 56 56 56 56 4838 4838 4838 4838 4838 3871 3871 3871 3871 3871 293 293 293 293 293 1935 1935 1935 1935 1935 2742 189 12879 7411 1161 5589 121 1156 999 999 999 999 999 999 999 1591 79 166 158 1942 6297 6194 6194 9864 4749 13 19 124 5796 126 12544 8548 4919 4838 4838 76 39 18954 12879 7411 5832 5832 13122 47 1579 25974 1156 17982 97 2164 1614 1942 6297 4955 4955 11149 5987 1342 196 48 48 138 738 1638 125 8548 4919 3871 3871 89 4677 148 18954 12879 7411 4374 4374 145 855 337 25974 1156 199 115 4162 1614 1942 6297 3716 3716 12388 7226 25 196 882 315 125 8548 4919 293 293 9677 5645 216 18954 12879 7411 2916 2916 12879 7411 2551 1458 7411 2551 138 9963 4495 11421 5953 193 25974 1156 1156 3496 21978 133 61 1614 1942 6297 2478 2478 13626 84 3819 196 324 324 16632 1332 4662 125 8548 4919 1935 1935 8548 4919 1644 6612 2983 4252 7411 2551 1156 3496 151 8158 1498 1156 3496 1942 6297 2168 1239 6297 2168 94 558 929 6297 2168 2646 2646 11844 6174 1134 2646 1693 968 4919 1693 968 968 968 968 3951 726 4919 1693 Ambient O.D. WGERV-*3 WINTER HEATING PERFORMANCE (INDOOR DESIGN CONDITIONS F DB) 45 CFM 76% EFFICIENCY VENTILATION RATE 3 CFM 78% EFFICIENCY 2 CFM % EFFICIENCY DB/ F WVL WHR WVL WHR WVL WHR 1847 1558 121 48 3694 3117 324 2419 55 554 46 3629 5 7387 6234 48 4838 45 9234 999 7792 48 4 145 1181 9351 972 7258 35 11 12928 13986 199 1584 8467 3 1944 14774 15984 12468 1296 9677 25 218 16621 17982 1426 138 1886 2 18468 199 15584 1296 15 2673 2315 21978 17143 16632 1336 NOTE: Sensible performance only is shown for winter application. Ambient O.D. WGERV-*5 WINTER HEATING PERFORMANCE (INDOOR DESIGN CONDITIONS F DB) 45 CFM 77% EFFICIENCY VENTILATION RATE LEGEND: 3 CFM 78% EFFICIENCY 2 CFM 79% EFFICIENCY DB/ F WVL WHR WVL WHR WVL WHR 18 2 15 151 119 48 374 4 312 32 239 55 561 599 46 454 35 5 74 623 5 47 VLT = Ventilation Load - Total VLS = Ventilation Load - Sensible VLL = Ventilation Load - Latent HRT = Heat Recovery - Total HRS = Heat Recovery - Sensible HRL = Heat Recovery - Latent WVL = Winter Ventilation Load WHR = Winter Heat Recovery 45 93 999 779 59 4 145 1123 1199 935 9 71 35 11 19 1399 191 15 83 3 1944 149 159 124 12 95 25 218 1684 179 143 1361 1 2 1871 199 155 1195 15 2673 25 219 1714 1663 1314 NOTE: Sensible performance only is shown for winter application. Page 8 of 14

W24G CRV Airflow Versus Position - Low Speed 55 5 45 4 35 3 25 2.15" ESP.3" ESP 15 5 W24G CRV Airflow Versus Position - Medium Speed 55 5 45 4 35 3 25.15" ESP.3" ESP 2 15 5 Commercial Room Ventilator Performance Data 55 5 45 4 35 3 25 2 15 5 W24G CRV Airflow Versus Position - High Speed.15" ESP.3" ESP Page 9 of 14

W3-36G CRV Airflow Versus Position - Low Speed 55 5 45 4 35 3 25 2 15 5.15" ESP.3" ESP W3-36G CRV Airflow Versus Position - Medium Speed Commercial Room Ventilator Performance Data 55 5 45 4 35 3 25 2 15 5 55 5 45 4 35 3 25 2 15 5.15" ESP.3" ESP W3-36G CRV Airflow Versus Position - High Speed.15" ESP.3" ESP Page 1 of 14

W42-G CRV Airflow Versus Position - Low Speed 55 5 45 4 35 3 25 2 15 5.15" ESP.3" ESP Commercial Room Ventilator Performance Data 55 5 45 4 35 3 25 2 15 5 9 85 55 5 45 4 35 3 25 2 15 5 W42-G CRV Airflow Versus Position - Medium Speed W42-G CRV Airflow Versus Position - High Speed.15" ESP.3" ESP.15" ESP.3" ESP Page 11 of 14

Cooling Application Data - Outdoor Temperature Model W24G3 W3G3 W36G3 W42G3 W48G3 WG3 Return Air (DB/WB) /62 /67 85/72 /62 /67 85/72 /62 /67 85/72 /62 /67 85/72 /62 /67 85/72 /62 /67 85/72 Cooling Capacity Below 5 F, unit requires a factory or field installed low ambient control. Return air temperature F. Air Temperature Entering Outdoor Coil Degree F F F F F 85 F 9 F 95 F F 15 F 11 F 115 F 12 F 125 F 28,3 2, 3, 19,9 33,2 19, 34, 26,3 37,4 26, 4, 25, 39,5 3,3 4,3 28, 5, 29,9 46,5 35,4 47,4 33,5 58, 34, 55,9 41,2 57, 39,, 4, 67, 48,9 69,2 46,3 85, 48, 27,5 19,9 29, 19, 32,3 19,5 33, 25,9 36,5 25, 39,5 25,4 37,9 29,5 39, 28,3 48, 29,2 44,9 34,9 46,9 33,4 57, 34,5 53, 4,4 55,5 38, 67,4 4, 64,4 47, 67,3 45, 81, 47, 26, 19, 29, 19,5 31,4 19,3 32, 25,4 35,5 25,2 38,4 25, 36,5 28, 38,9 27,9 46,4 28, 43,4 34,3 46,3 33,2 55,2 34, 5, 39,5 54, 38,3 64,3 39,2 61,4 46,2,5 44, 78, 45,9 26, 19,5 28,3 19,4 3,5 19, 31, 25, 34, 24, 37,4 24,5 34,9 28,2 38, 27, 44,5 28, 41, 33, 45,4 33, 53, 33,5 48,2 38, 52,5 37, 61,4 38,4 58,3 44,9 63,5 44, 74,2 44, 25,2 19,3 27,5 19,2 29, 19, 3,9 24,5 33, 24,5 36,4 24, 33,4 27,5 37, 27,2 42, 27,4 4, 32,9 44,5 32, 51, 32, 46, 37, 51, 37,4 58, 37, 55,5 43, 61, 43,2, 43,4 24,4 19, 26, 19, 28, 18, 3, 24, 32,9 24, 35,4 23, 32, 26, 36, 26, 4, 26, 38,3 32,2 43,3 32,2 48,9 32, 43,9 36,9 49, 36,9 56, 36, 52, 42,4 59, 42,4 67,3 42, 23, 18,9 26, 19, 27,9 18, 29, 23, 32, 23, 34,4 23,3 3,5 26,2 35, 26,4 38,9 25,9 36, 31,4 42, 31, 46, 31, 41, 36, 48, 36,4 53,3 35, 5, 41,2 57,5 41, 63,9 4, 22, 18,5 25, 18, 26, 18,3 27,9 23, 3, 23,2 32,9 22, 29, 25,5 33,9 25,9 37, 25, 34,9 3, 4, 31, 44,4 3, 39,9 35,3 46,5 35,9 5,9 34, 47, 4, 55,5 4,, 39,4 21,9 18, 24, 18,2 25, 17,9 26, 22,5 29,3 22, 31,5 22,2 27, 24,9 32, 25,5 35,2 24,3 33, 29, 39, 3,4 42, 29, 38,2 34,4 45, 35,3 48,5 33, 45,2 38, 53,3 39, 57,5 37,9 21, 17, 23, 17, 24, 17,5 25,4 22, 28, 22, 3, 21, 26,3 24,2 31,3 25, 33,3 23,5 31,2 28, 37,2 29, 39, 27,9 36,5 33, 43,5 34, 46,3 32,5 42,9 37, 51,2 38,9 54,5 36,5 2, 17,4 22, 17,5 23, 17, 24,2 21,5 26, 21, 28, 21,2 24, 23, 29, 24,5 31,3 22, 29,3 27, 35,3 28,9 37, 26, 34,9 32, 42, 34, 44, 31,3 4, 36,5 49, 38, 51,5 35, 19,3 17, 21,2 17,2 22, 16,9 23,2 21, 25,5 21,2 27,4 2, 23,4 23, 28,3 24, 29,4 21, 27,5 26, 33,3 28, 34, 25,3 33,3 31,9 4,4 33,4 42, 3,2 38,5 35,4 46, 37, 48,5 33,5 18, 16, 2,4 16,9 21,9 16,5 22,3 2, 24,4 2, 26,2 2,4 21,9 22,3 26, 23,5 27,5 2, 25,5 25, 31, 27, 31,9 23,9 31,9 31, 38,9 32, 4, 28,9 36,4 34,3 44,4 36, 45, 32, Capacity Multiplier Factors % of Rated Airflow -1 Rated +1 Total BTUH Sensible BTUH.9.95 1. 1. 1.2 1.5 Page 12 of 14

DIMENSIONS OF BASIC UNIT UNIT A B C D E F G H I J K L M N O P Q R W24G-W3G-W36G 7.88 27.88 13.88 24.25 4 25.63 81.63 27.38 27.5 39.25 5.88 14.88 3 14.12 15.44 15.31 4.5 2.5 W42G-W48G-WG 9.88 29.88 15.88 27.25 43.81 31.63 87.5 33.38 28. 42.88 3. UNIT S T U V W X Y Z AA BB CC DD EE FF GG HH II W24G-W3G-W36G 12-7 HOLES 2.88 22.9 38 17.84 4.44 11.44 9 36.25 2.38 3. 2.25 3.25 7.25 1.13 1.25 W42G-W48G-WG 16-6 HOLES 3.88 24.9 42 17.34 8.44 12.19 1 4.25 2..44 W 4 DEG. PITCH IN TOP P D E DD FF EE GG 1 HH II 1 O B R F G CONDENSER AIR OUTLET VESTIBULE DOOR COMBUSTION AIR EXHAUST COMBUSTION AIR INTAKE FRONT DOOR FILTER SERVICE DOOR CONTROL PANEL DOOR N CIRCUIT BREAKER/ DISCONNECT ACCESS PANEL (LOCKABLE) VENT OPTION PANEL CONDENSER AIR INLETS A U I M Z L C J K H GAS ENTRANCES LOW VOLTAGE ENTRANCES HIGH VOLTAGE ENTRANCES Q X AA Y V CC SUPPLY OPENING BB B RETURN OPENING S S S S S FRONT RIGHT SIDE BACK T Optional top outlet in place of standard front supply opening, see Nomenclature outlet options (next page). Standard unit can also be field converted to this configuration using approved top supply outlet conversion kit shown on next page. MIS-3239 A Minimum Clearances INSTALLATION W24G - W3G - W36G W42G - W48G - WG Installation Wall (from combustible materials) " " Outlet Duct (from combustible materials) 1" first 3' 1" first 3' Vent Terminal (from combustible materials) 17" 16" Top (from combustible materials) 1" " Condenser Air Inlets 2" 2" 1-inch clearance at rear top of unit (at the wall surface). The 4 pitch of top creates 1.688 inch clearance between front top and any extended overhang above the top of the unit. -inch clearance at rear top of unit (at the wall surface). The 4 pitch of top creates.688 inch clearance between front top and any extended overhang above the top of the unit. Service Access ALL MODELS Burner Service - Right side 2" Compressor - Right side 2" Controls - Right side 2" Condenser Fan - Left side 2" Page 13 of 14

Air Conditioning Wall-Mount Model Nomenclature MODEL NUMBER COOLING CAPACITY 24-2 Ton 3-2½ Ton 36-3 Ton 42-3½ Ton 48-4 Ton - 5 Ton Page 14 of 14 W 36 G 3 A N B X X X X X X GAS/ELECTRIC REVISION CODE D = DEHUMIDIFICATION OPTION Insert D in place of dash (-). Ventilation Options VOLTS & PHASE A - 23/28--1 B - 23/28--3 C - 4--3 Bard Manufacturing Company, Inc. Bryan, Ohio 4356 www.bardhvac.com EMISSIONS N - NOx Certified HEATING INPUT 2-3 Ton 3.5-5 Ton A = 45, B = 68, B = 68, C = 9, C = 9, Low ambient control is required with economizer for low temperature compressor operation. Independent selection of intake and exhaust speeds (rate) with terminal block selection. â Color option must be specified to match unit ("X" = Beige; "4" = Buckeye Gray) FILTER OPTIONS X - 2-Inch Pleated (MERV8) W - 1-Inch Washable VENT OPTIONS (See Chart Below) COLOR OPTIONS X - Beige 1 - White 4 - Buckeye Gray 8 - Dark Bronze Due to our continuous product improvement policy, all specifications subject to change without notice. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. CONTROL MODULES (See Control Module Options) COIL OPTIONS X - No Coating 1 - Phenolic Coated Evap. 2 - Phenolic Coated Cond. 3 - Phenolic Coating on both coils OUTLET OPTIONS X - Front T - Top Top Supply Outlet Conversion Kits-Field Installed (Convert Standard Front Outlet to Top Outlet) Air Conditioning Control Modules AVAILABLE CONTROL OPTIONS Models W24G, W3G, W36G W42G, W48G, WG Description Factory Installed Field Installed Factory Installed Field Installed Code No. Part No. Code No. Part No. Barometric Fresh Air Damper - No Exhaust X WGBFAD-3 X WGBFAD-5 Blank-Off Plate B WGBOP-3 B WGBOP-5 Motorized Fresh Air Damper - No Exhaust M WGMFAD-3A M WGMFAD-5A Commercial Ventilator - Spring Return w/exhaust V WGCRVS-3A V WGCRVS-5A Commercial Ventilator - Power Return w/exhaust P WGCRVP-3A P WGCRVP-5A Economizer (Internal) Fully Modulating w/exhaust E WGJIFM-3 E WGJIFM-5 Energy Recovery Ventilator - 23 Volt w/exhaust R WGERV-A3B-â R WGERV-A5B-â Energy Recovery Ventilator - 4 Volt w/exhaust R WGERV-C3C-â R WGERV-C5C-â USED WITH MODELS UNIT COLOR X - BEIGE UNIT COLOR 4 - BUCKEYE GRAY UNIT COLOR 8 - DARK BRONZE W24G, W3G, W36G TSO-WG3-X TSO-WG3-4 TSO-WG3-8 W42G, W48G, WG TSO-WG5-X TSO-WG5-4 TSO-WG5-8 CCM j HPC LPC LAC Factory Installed Code Standard Unit Field Installed Code Dehumidification Unit Field Installed Code STD STD STD X N/A N/A STD STD STD H CMA-6 CMA-28 STD = Standard equipment CCM. Compressor control module has adjustable 3-second to 5-minute delay-on-break timer. On initial power-up, or any time the power is interrupted, the delay-on-make will be 2-minutes plus 1% of the delay-on-break setting. There is no delay-on-make during routine operation of the unit. The module also provides the lockout feature (with 1 retry) for high and/or low-pressure controls, and a 2-minute timed bypass for low-pressure control. HPC. High pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note. LPC. Low pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note. LAC. Low ambient control permits cooling operation down to F. Optional Field Installed Accessories DESCRIPTION PART NUMBER Natural Gas High Altitude Pressure Switch Kit ( - 1, Feet) 862-189 Note: Natural Gas Orifice Change May Be Required Depending Upon Altitude and Gas BTU content. See Orifice and Altitude Tables. Propane Gas Conversion Kit ( - Feet Altitude) WGCK-1 Propane Gas Conversion Kit ( - 1, Feet Altitude) WGCK-2 Vertical Vent Kit (Includes all parts for 5 foot vertical vent) VVK-5A Additional 1 foot vertical vent pipe section for VVK-5A 862-21 Additional 2 foot vertical vent pipe section for VVK-5A 862-1 Additional 3 foot vertical vent pipe section for VVK-5A 862-2 Additional 5 foot vertical vent pipe section for VVK-5A 862-171 Form No. S351 October, 216