ESD3000IR ESD3000IR. Infrared Gas Detector

Similar documents
ESD3000 ESD200 Combustible / Toxic Gas Detector

ESD500. ESD500 Combustible / Toxic Gas Detector

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]

MERIDIAN UNIVERSAL GAS DETECTOR

Installation and Wiring 1.

TECHNICAL NOTE. Response Factors for Flame Ionization Detector Operation FLAME IONIZATION DETECTOR OPERATION BASICS

Meridian. Universal Gas Detector. Description. Features. Minimal drift High specificity Digital ID Broader toxic gas detection

APPLICATION DATA SHEET

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

Dräger Polytron SE Ex Fixed Gas Detector

PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases

Dräger PEX 3000 Flammable Gas Detection

MICROpeL 75 Combustible Gas Sensor Part Number: PM

LFL Monitoring. MEGTEC Systems

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Installation & User Manual

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

GAS PLUS ALARM SYSTEM

VSD AND SS DRIVING ATEX MOTORS February 2014

Type SP87300 SAFE-T SHP9 Explosion Proof Stirring Hot Plate

Explosion protection Marijan Gorše, dipl. ing.

Combustible Gas Detection and Control System

Explosion-proof Duct Heaters

Thank You for Attending Today s Webinar:

Electron Microscopy Sciences

1. GENERAL TECHNICAL INFORMATION

and storage tanks. CO and NOx detection from diesel engine emissions Hospitality Hotels and restaurants LPG detection in commercial kitchens

Operation and Maintenance Manual

ia d ATEX 100 II 2G D MT 99 ATEX G 001 x EX-METER II Series [ Versatility in Explosive Atmospheres]

OLC(T) 100 FIXED GAS DETECTOR

THE BELGIAN PIONEER IN GAS DETECTION

Gas detector INSTRUCTION MANUAL THE BELGIAN PIONEER IN GAS DETECTION

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

SEC Millenium Hydrocarbon Gas Detector

CC28. Operation Manual. Transmitter for flammable gases and vapours

Explosion Proof Speaker, Ringer & Speaker/Ringer

FACT SHEET Program: Lab Fire Safety

Operation Manual Infrared Hydrocarbon Gas Detector SGOES

THE BELGIAN PIONEER IN GAS DETECTION

Guide for hazardous areas

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

Fire Alarm System Accessories

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

3M Oldham OLCT 100. Description. Fixed Gas Detector

GMA101. Operation Manual. Worldwide Supplier of Gas Detection Solutions

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres C E R T I F I E D DANISH TECHNOLOGICAL INSTITUTE

PREMIER PLATINUM INFRARED GAS SENSOR

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]

SAFETY APPROVED FLASHLIGHTS: UNDERSTANDING THE REQUIREMENTS INTRODUCTION & OVERVIEW

OLCT IR TECHNICAL MANUAL INFRARED DETECTOR FOR FLAMMABLE GASES OR CO 2. The Fixed Gas Detection Experts. Part Number : NPOIRGB Revision : E

A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

Explosion-protected actuator Page 259 of 292

Model FP-424C ma Combustible Gas Sensor (0-100% LEL) Operator s Installation & Instruction Manual. May 18, 2010 Document #2243T Version 3.

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

BSF4-AH80. Flameproof Type Light Curtain Type 4. Globally-compliant flameproof structure. Ample protective height 1,595 mm 62.

ST Explosion Protection GAS DETECTION SYSTEMS

Selection guide...p.457~ SF-C13...P.663~ Glossary of terms... P.1549~ General precautions... P panasonic.net/id/pidsx/global

DESIGN MANUAL MODEL GIR900 INFRARED COMBUSTIBLE GAS SENSOR

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Model C Combustible Gas Transmitter. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

SBS-H2 Hydrogen Gas Detector Kit

Dräger Flame 2500 Flame Detection

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres

Beamex Calibration White Paper. Calibration in hazardous areas

User Manual. PolyGard AT-3300 V3. Transmitter for Combustible Gases. Serial No. ET April 2009

Model D12-IR. Digital Gas Transmitter...

Detcon MicroSafe. FP-624HT Combustible Gas Sensor (0-100% LEL) Specialized Version For High Temperature Operation of Sensor Head

OLCT IR TECHNICAL MANUAL INFRARED DETECTOR FOR FLAMMABLE GASES OR CO 2. The Fixed Gas Detection Experts. Part Number : NPOIRGB Revision : G.

P R O D U C T D ATA S H E E T

Hydrocarbon Gas Detector

LOW POWER VERSION DUAL HYDROCARBONS AND CARBON DIOXIDE SENSOR Exd Certified VERSIONS *** Available in EN50271 / SIL1 Certified versions ***

Fire Alarm System Accessories

Dräger Flame 2100 Flame Detection

Dräger Flame 2500 (IR3) Flame Detection

Beamex. Calibration White Paper. Calibration in hazardous areas

Flameproof Type Light Curtain Type 4

GMA 41. Operation Manual. Worldwide Supplier of Gas Detection Solutions

Operation and Maintenance Manual

ATEX Safety Switches. More than safety.

Hazardous area descriptions

GMA44 Operation Manual

GG-LEL2 COMBUSTIBLE GAS SENSOR. Installation and Operation Manual

INSTRUCTION MANUAL Detcon Model FP-524D-HRT

Dräger Polytron 8700 IR Detection of flammable gases and vapors

SP-220. Features. Combustible handheld gas leakage detector

Portable Combustible Gas Detector GP-1000 Operating Manual (PT0-120)

700 IR Series. Instruction Manual. Infrared Gas Detector for Combustible and CO 2 gases OLCT 700 OLCT 710. The Fixed Gas Detection Experts

INSTRUCTION MANUAL Detcon Model FP-524D

PRODUCT CATALOG 2016 PT. Victoria Globalindo Teknik PT. Victoria Agfasindo

THERMAL ELECTRIC ELEMENTS

Explosion Proof Speaker, Ringer & Speaker/Ringer

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Transcription:

ESD3000IR ESD3000IR Infrared Gas Detector Infrared gas sensor Ex-proof certificate Exd ⅡC T6 Gb Dust Ex-proof certificate Ex td A21 IP66 T80 Site LCD display HART communication Replaceable sensor design With audial & visual alarm and relay output 34

ESD3000IR Infrared Gas Detector Specifications Detected gas: combustible gas/ carbon dioxide Detection theory: Infrared Spectroscopy absorption Measure scope: 0~100%LEL (combustible gas)/ 0~5%v/v (carbon dioxide) Accuracy: ±3%LEL (combustible gas)/±3%fs (carbon dioxide) Repeatability: ±2% Response time: T90<20S Electrical Power supply: 24VDC (normal working voltage: 10-30VDC) Power consumption: <2.5W Output signal: 3-wire 4~20mA+HART+relay (1A@24VDC)+audial & visual alarm (96dB @0.1m) Structural Main parts material: ADC12 aluminum alloy/316 stainless steel Thread: M20X1.5, 1/2NPT internal thread ( select G3/4 or G1/2 or 3/4NPT) Weight: 2.17kg (aluminum alloy) /4.1 kg(stainless steel) Certificate Ex-proof certificate: Exd ⅡC T6 Gb/Ex td A21 IP66 T80 Fire safety certificate: CCCF Metrological certificate: CMC Standard implemented: GB 15322.1-2003, GB 3836.1-2010, GB 3836.2-2010, GB 3836.4-2010, GB 12476.1-2013, GB 12476.4-2010, GB 12476.5-2013, JJF 1368-2012 Operating condition IP rating: IP66 Temperature: -40 ~70 Humidity: 10~95%RH (Non-condensing) Pressure: 86~106KPa 35

Dimension 97 121.0 205 Unit: mm Display Product fault Alarm indicate Density value Gas density unit detected HART communication guide Zeroing indicate 36

Mounting bracket 17 1 42.5 1 04 Ø 40- Ø 80 86.00 102.00 36 Unit: mm Mounting style Horizontal pole Vertical pole Wall type 37

Components Visual alarm assembly Audial alarm assembly EMC components Terminal cover assembly Display cover assembly Display assembly Peripheral components Enclosure assembly Sensor assembly Explosion-proof cover Weatherproof cover Commissioning and calibration Controller Detector Pressure relief valve with flow meter Calibration cup Conduit Standard gas cylinder 38

Site commissioning Terminal wiring Wiring terminal with relay Wiring terminal 39

Electrical wiring Controller 1 V+ 1 V+ Detector 2 S 2 S RL V- V- 3 3 Equipment connected with relay Equipment power supply Equipment J 4 K 5 connection of 3-wire detector with controller (with relay) Flameproof wiring style Flameproof adaptor Cable Cable peeling position Wiring Terminal Take equipment with relay for instance 40

Selected cross-sectional area of selected cable and transportation distance is as follows (when connected with ExSaf controller): Cross-sectional Area(mm 2 ) 1.00 1.50 2.50 Resistance (ohms per km) 18.1 12.1 7.4 Maximum Distance (m) (loop distance) 1500 2500 3000 ESD3000IR Gas Detector Type Selection Table Model Product illustration ESD3000IR Gas detector Code Sensor type code H infrared Code Gas type KXXX Combustible gas (see combustible gas list) CO2 Carbon dioxide Code Range LEL 0-100%LEL 5V 0-5%v/v Code Electrical interface M20 M20 12NPT 1/2NPT G34 M20X1.5 rotate to G3/4 G12 M20X1.5 rotate to G1/2 34NPT M20X1.5 rotate to 3/4NPT Code Output signal 3HJS 3-wire 4~20mA+HART+relay+audial and visual alarm Code Enclosure material C12 ADC12 aluminum alloy 316 316 stainless steel Code Mounting style P Normal mounting style Code System name X ExSAF gas detection system ESD3000IR H K001 LEL G34 3HJS C12 P X (product type selection demonstration) 41

ESD3000IR Detectable Combustible Gas List NO. Gas name Formula Corresp. D. Flash point ( ) Combustible limit (V %) LFL UFL Ig. TEMP ( ) MESG (mm) TEMP G. Grade K001 Methane CH 4 0.55 5 15 540 1.14 T1 IIA K002 Toluene C 6 H 5 CH 3 3.2 4.4 1.2 7.1 480 T1 IIA K003 Methanol CH 3 OH 1.11 11 6.7 36 385 0.92 T2 IIA K004 Methyl formate HCOOCH 3 2.07-18.9 5 23 465 T1 IIA K005 Ethyl formate HCOOCH 2 CH 3 2.65-20 2.8 16 455 0.91 IIA Ethyl methyl K006 Ether CH 3 OCH 2 CH 3 2.1-37 2 10.1 190 T4 IIB K007 Ethane CH 3 CH 3 1.04 3 15.5 515 0.91 T1 IIA K009 Ethanol CH 3 CH 2 OH 1.59 12.8 3.3 19 422 0.91 T2 IIA K010 Ethyl benzene CH 3 CH 2 C 6 H 5 3.66 15 1 6.7 430 T2 IIA K012 Methyl acetate CH 3 COOCH 3 2.56-10 3.1 16 501 T1 IIA K013 Ethyl acetate CH 3 COOCH 2 CH 3 3.04-4.4 2.2 11 427 0.99 T2 IIA K014 N-butyl acetate CH 3 COOCH 2 (CH 2 ) 2 CH 3 4.01 22 1.7 7.3 425 1.04 T2 IIA K015 Propane CH 3 CH 2 CH 3 1.56 2.1 9.5 466 0.92 T1 IIA K016 Propyl alcohol CH 3 CH 2 CH 2 OH 2.07 25 2.1 13.5 440 0.89 T2 IIB K017 Propylene CH 2 =CHCH 3 1.5 2 11.1 460 0.91 T1 IIA K018 Acetone (CH 3 ) 2 CO 2-17.8 2.6 12.8 465 1.01 T1 IIA K019 Butane C 4 H 10 2.05 1.9 8.5 405 0.9 T2 IIA K020 Butanone CH 3 CH 2 COCH 3 2.48 1.1 1.8 10 404 0.84 T2 IIB K021 Butadiene CH 2 =CHCH=CH 2 1.87 2 12 420 0.79 T2 IIB K022 Pentane C 5 H 12 2.48 <-40 1.4 7.8 260 0.93 T3 IIA K023 Hexane CH 3 (CH 2 ) 4 CH 3 2.97-22.8 1.1 7.5 225 0.93 T3 IIA K024 Heptane C 7 H 16 3.46-3.9 1.1 6.7 215 0.91 T3 IIA K025 Octane CH 3 (CH2) 3 CH 3 3.93 13.3 1 6.5 220 0.94 T3 IIA K026 Nonane CH 3 (CH 2 ) 7 CH 3 4.43 31 0.7 5.6 205 T3 IIB K031 Isobutane (CH 3 ) 2 CHCH 3 2 1.8 8.4 460 0.95 T1 IIA K032 Isopropanol (CH 3 ) 2 CHOH 2.07 11.7 2 12 399 1.00 T2 IIA K033 1-butanol CH 3 (CH 2 ) 2 CH 2 OH 2.55 28.9 1.4 11.2 365 0.94 T2 IIA K034 Cyclohexane CH 2 (CH 2 ) 4 CH 2 2.9-20 1.3 8 245 0.94 T3 IIA K035 Cyclopentane CH 2 (CH 2 ) 3 CH 2 2.4 <-6.7 1.4 380 1.01 T2 IIA K036 Propylene oxide CH 3 CHCH 2 O 2-37.2 2.8 37 430 0.7 T2 IIB K037 Ethylene oxide CH 2 CH 2 O 1.52 <-17.8 3.6 100 435 0.59 T2 IIB K038 Diethyl ether (CH 3 CH 5 ) 2 O 2.55-45 1.9 36 170 0.87 T4 IIB K039 Dimethyl ether (CH 3 ) 2 O 1.59 3.4 27 240 0.84 T3 IIB K040 Xylene C 6 H 4 (CH 3 ) 2 3.66 25 1 7 464 1.09 T1 IIA K041 Gasoline C 4 ~C 12 hydrocarbon mixture 0.73 <-20 1.1 5.9 280 T3 IIA K042 Jet fuel, kerosene C 9 ~C 16 hydrocarbon mixture 0.8 <30 0.6 210 T3 IIA 42