AGT 1 Confined Space. Authorised Gas Tester 1. Scienco Limited. Authorised Gas Tester 1 1

Similar documents
T.ex Single Gas Detector VISA

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex

NJSP HMRU. Module 5 B HM Operations 1

Training, Assessment, Consultants for Hazardous & Industrial Areas

Operate the Mutli-Gas Monitor PID

GENERAL STANDARD FOR GAS DETECTORS ORIGINAL EDITION MAY 1997

Polytector III G999 for Ex zone 0

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview

Understanding the practicalities of using gas detectors in confined spaces

INTERNATIONAL STANDARD

AS/NZS :2008

Level 2 Award in Fire Safety (QCF) (SCQF Level 5 in Scotland) Unit 1 title: Fire safety principles

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Selecting Gas Detectors for Confined Space Entries

NZQA registered unit standard version 1 Page 1 of 5. Install fixed gas detection apparatus in hazardous areas

Training Authorised Gas Tester Level 1. Basic Information

BP MAINTENANCE WORK INSTRUCTIONS FREQUENTLY ASKED QUESTIONS

Review Fire Test Report

Dräger X-am 7000 Multi-Gas Detection

Training Standard. Draft

Portable Gas Detection Practice

Datalogging as standard

Use of R1234yf, R744 (CO 2 ) and R134a in automotive air conditioning

Explosive atmospheres Part 29-2: Gas detectors Selection, installation, use and maintenance of detectors for flammable gases and oxygen

SOUTH AFRICAN NATIONAL STANDARD

Microtector II G gas-detector with performance test approval. Worldwide Supplier Of Gas Detection Solutions

Gas Detection GAS BOOK.

Signalpoint. The Signalpoint range of flammable, toxic and Oxygen gas detectors offer users a low cost solution to their indoor gas monitoring needs

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Process Control PIP PCEA001 Fixed Gas Detection Guidelines

intrinsically safe detector for hydrocarbon gases

Presentation to. IOSH Food and Drink Group. Danny McDougall Richard Perkin

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Facilities and Estates. Hot Works: Standard Operating Procedure. Document Control Summary

Guided Learning Hours (GLH) 4 Invigilated Assessment (IA) 1 Total Qualification Time (5)

Health and Safety Policy. Version Author Revisions Made Date 1 Colin Campbell First Draft March 2014

At the end of this study topic, you will be able to discuss the chemistry of fire; discuss the fire dynamics in a compartment fire; and explain the

G-TECTA TM. Portable Gas Detection Instruments

KRISHNAMURTI FOUNDATION TRUST FIRE SAFETY POLICY. Last Review Date 30 June Next review date 30 August Health and Safety Officer

Properly calibrating catalytic bead sensors: A practical guide

HeatExchangerSpares.com Ltd HRS Heat Exchangers Ltd HRS Hevac Ltd HRS Hevac Engineering Ltd HRS International Ltd HRS Investments Ltd

Fact Sheet No.2. CompEx Modules EX01 to EX04 for Gas and Vapour Environments

Fact Sheet No.4. CompEx Modules EX01R to EX04R for Gas and Vapour Environments

Gas Detection. - Disposable - Serviceable. Single Gas Detectors

TECHNICAL GUIDE ON DIRECT-READING DEVICES FOR AIRBORNE AND SURFACE CHEMICAL CONTAMINANTS

Leaders in health, safety & environmental consultancy & training

IMO Resolution MSC 61 (67) 1996; Annex 1, Part 2. Smoke & Toxicity Test. WF Report Number: Date: 13 th August Test Sponsor:

Zareba Metro Gas Detector

Choosing the best confined space gas detector

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Fire risk management plan. MH/05/Revised/06/17

Sieger Apex. Flexibility that meets your requirements

Product Supply, Hire & Service. Complete Safety Solutions for the Oil, Gas, Marine & Energy Industries. Safer.Smarter.Tyco.

Legislation & Standards

Electrical Safety Policy

Leaders in health, safety & environmental consultancy & training

Dräger Configuration and Evaluation Software

Choosing the best detection technologies for measuring combustible gas and VOC vapors

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

Fire Policy. Fire Safety Order (2005) Dangerous Substances and Explosive Atmospheres Regulations (2002)

APPLICATION DATA SHEET

Dräger Catalytic Ex-Sensors DrägerSensors

Thank You for Attending Our February Webinar:

PRODUCT GUIDE. ionscience.com Unrivalled Gas Detection.

IMO Resolution MSC 61(67): Annex 1: Part 2

IGD.CO.UK

Dräger Pac 7000 Single-Gas Detection Device

Bw Gas Alert Clip 2 H2s Extreme User Manual

QUALIFICATIONS AND CREDIT FRAMEWORK (QCF) LOGIC CERTIFICATION LIMITED (LCL) QUALIFICATION SPECIFICATION

STANDARDS FOR VAPOUR EMISSION CONTROL SYSTEMS ( MARPOL reg VI/15 )

Dräger X-am 2500 Multi-Gas Detection

ARE YOU AN AUTHORISED REFRIGERATION GAS PRACTITIONER?

Safe Operation Manual. Honeywell IQ Force Gas Detector

Gas Technology Services

NATIONAL RULES FOR ELECTRICAL INSTALLATIONS IN POTENTIALLY EXPLOSIVE ATMOSPHERES. ET 105:2001 (Second Edition)

The smart alternative

THE MARINE SUPPLY COMPANY WITH A 4 HOUR RESPONSE GUARANTEE

Catalytic Bead DrägerSensor Sensors for Fixed Gas Detectors

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Catalytic Bead DrägerSensors for Fixed Gas Detectors

IFE Level 3 Diploma in Fire Science and Fire Safety

POLICY FOR FIRE SAFETY MANAGEMENT

Dräger Pac 5500 Single-Gas Detection Device

Fire Risk Assessment 2017

HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT

1.1 Definitions of alert icons. For your safety

PRODUCT SAFETY DATA SHEET

SMOKE CONTROL - NEW DIRECTIONS

Construction Heat CH-02 (up to 400,000 BTU) Record of Training Curriculum Document

THE BELGIAN PIONEER IN GAS DETECTION

Sensepoint. The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs.

Why is this important?

Guidance on Video Smoke Detection Technology (VSD)

ST Safety to go. DRÄGER PORTABLE GAS DETECTION INSTRUMENTS

Laboratory Inspection (version 3) Criteria Action Plan

TOXIC GAS AND OXYGEN DETECTOR DTX 420 INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS DTX420_MAN01_EN_V1R2

Touchpoint 4. The Touchpoint 4 controller provides protection of personnel and plant from flammable, toxic and Oxygen gas hazards

INSTALLATION & MAINTENANCE of FIRE ALARM SYSTEMS

Transcription:

Scienco Limited AGT 1 Confined Space Authorised Gas Tester 1 Instructor: Gary Taylor E-Mail: gary@scienco.com Phone: +44 117 971 0001 Office: 10 Chapel Way, Bristol UK BS4 4EU Office Hours: 08:30 to 17:00 Authorised Gas Tester 1 1

Overview The following programme is designed to meet the initial training and validation requirements for those intending to work as Authorised Gas Testers. We actively work with our clients to produce tailored training courses that meet the specific needs of those active in all industries including oil & gas exploration, oil and gas transportation and storage, petrochemical, shipping, manufacturing, tank & vessel cleaning and inspection companies. AGT Level 1 is required for those involved with performing a tests for oxygen, flammable and toxic gases up to and including working in confined spaces. NOTE: Persons undertaking Safety Watch duties at the entrance to a confined space should also attain AGT Level 1. Programme Format Delegates attending this training programme are given a series of presentations and scenarios, which explain and demonstrate the safe and proper use of gas detectors. The course covers: 1. An introduction and definition of a confined spaces 2. Interpreting operational instructions 3. Legislation, Codes of Practice and Guidance Notes 4. Testing requirements for oxygen, flammable and toxic gases 5. Procedures for confined space atmosphere testing 6. Selection and use of suitable gas detectors 7. Properties of gases and vapours 8. Identify problems and limitations in their knowledge and expertise 9. Interpretation and recording of results 10. Personal protective equipment 11. Examples and experiences of good and bad practice 12. Assessment and certification Materials All material will be provided although suitable PPE may be required for site specific assessments. Details Location All courses may be undertaken at Scienco s offices and training facilities or at your own place of employment. Course Length The course including assessments normally last 2 days unless amended to suit specific needs. Physical Demands All those who undertake the course should be medically fit and able to participate fully. The responsibility for ensuring those who attend are fit to do so rests with the delegate and company sponsoring them. Requirements There are no pre-requisites for attending the course; however, those attending should note the technical nature of the material means a reasonable scientific and academic ability would be advantageous. Evaluation Students are tested and assessed using a series of multiple-choice written tests and a multifaceted scenario, which they are required to complete. A score of 80% is required in each of the sections for a pass to be awarded. Authorised Gas Tester 1 2

Course Timetable: 1. Overview: 2. Module 1 Introduction 3. Module 2 4. Module 3 5. Module 4 6. Module 5 To introduce the safe operation of portable gas detectors used by your organisation for confined space testing. Completion of the course results in the delegate being issued with a Certificate of Attendance and Authorised Gas Tester Certificate Level 1 (Confined Space) Purpose of the training Summary of the day ahead Introduction of the assessment scenario Composition of air and how it becomes contaminated Reasons for gas testing Overview of legislation Definition of a confined space Introduction to air quality Identification of hazards associated with oxygen deficiency or enrichment, toxic and flammable gases Developing risk assessments to identify hazardous gases prior to entering a confined space Safe systems of work Duties of gas testers (Safety Watchers) Your company procedures and their interpretation The implications of organisational and statutory requirements Working within Permit to Work systems Raising of alarms and initiating emergency response The requirement to measure oxygen Oxygen depletion Oxygen enrichment Alarms The requirement to measure flammable gases & vapours Chemistry of fire Lower explosive limits Flashpoint and ignition temperatures Toxicity of gases, mists and fumes Workplace Exposure Limits (WEL s) Control of Substances Hazardous to Health (COSHH) Hydrogen sulphide Carbon monoxide Carbon dioxide Hydrocarbons Benzene Authorised Gas Tester 1 3

7. Module 6 8. Module 7 9. Module 8 10. Module 9 Personal protective equipment Selection and use Examples Provision of PPE Inspection of PPE Maintenance and storage Properties of gases Definitions & physical properties Density Neutral buoyancy effect Temperature effects Implications of the storage conditions Inside and outside buildings and plant Positioning of sensors and survey techniques Portable gas detectors Selection of personal, portable and area monitors Sensors o Catalytic beads o Infra-red o Photo ionisation o Electrochemical o Colour indicator tubes o Adsorption tubes and badges Sensor selection Pumped and diffusive sampling Sample tubing selection Pre-start checks Calibration Practical on-site testing Selection of the correct gas detector and setup for confined space entry checks To introduce the operation and maintenance of portable gas detectors Pre-start checks (repeated) Understanding gas detector calibration The behaviour of different flammable and toxic gases Range and frequency of atmosphere tests Understanding of safe entry concentrations, alarm levels and WEL s Sampling methods and how to obtain a representative sample Monitoring and re-tests Positioning of static equipment Interpreting and documenting of results Sources of errors in gas measurement and methods of minimising these 11. Module 10 Case studies Examples of good and bad practice Video presentation 12. Module 11 Theory assessment questions Authorised Gas Tester 1 4

13. Module 12 (optional) 14. Module 13 Gas detector user training o X-am 2000 o X-am 7000 o Accuro Pump and tubes o CMS o Multi PID o X-Zone Bump-testing and function checking Gas detector calibration (practical) Introduction to the practical assessment Scenario Individual practical assessment Authorised Gas Tester 1 5