Exit/Emergency Lighting Guide

Similar documents
TABLE OF CONTENTS. DLM LED Emergency Light DLH LED Remote Heads DLP Wet Location LED Emergency Light...25

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

IOTA Exit Signs. IOTA Emergency Fixtures

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

ILB-CP TBTS B MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED Patented. See iotaengineering.com/patents for more details

NYC Approved Product Series

DISTRIBUTOR SELECT COLLECTION. EMERGI-LITE Full range of emergency lighting solutions

The New Lux-Ray LED Emergency Lighting

PRODUCT OFFERING QUALITY VALUE VERSATILITY

Catalog Number. Notes. Type. FST Snap on frosted, diffuse L/LENS No diffuser

Exit Signs, Emergency Lighting & Fluorescent Emergency Ballasts

Catalog Number. Notes

LUCE 1 TL. specifications: internal. specifications: external. ordering logic. builder. Job/Location:

Architectural / led luminaires

Emergency Lighting. Product Guide LED. The right source for the. right light

HIGH BAY APPLICATIONS

Nightfall. led emergency egress lighting

EarthTronics products. About us. Where efficiency meets innovation. T5 & T8 Linear. Founded in 2007, EarthTronics, Inc. is a Michigan based

CHINESE NEW YEAR DEADLINE SOLUTIONS

Applications. Standard Materials

Lights the way to safety SEVERE SERIES. Certified for Food Preparation and Cold Storage Applications. NEMA-4X Certified for Harsh Environments

Dimensions (111mm) 3 (76mm) (111mm) (48mm)

SDL4 LED Strip Diffused Lens

CDL8 LED Architectural

BAS SDL8' LED Strip Diffused Lens

Step-Dimming and/or 0-10v Dimming Drivers Electro Galvanized Steel Welded Construction. Photocell Sensor - On/Off Stainless Steel Fasteners Standard

Dimensions (111mm) (111mm) 3 (76mm)

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit

MALIBU FM /2" N-Brushed Nickel. Nickel **ESTIMATED FROM LED SOURCE

Project. Comments. Prepared by. - EZ Hang feature facilitates fast - Prorated 5-year battery warranty - Overload / Short Circuit - NEC/OSHA

Millenium Os. Luminaire LED. For Stairwells and Public Spaces. Designed and manufactured in the USA. High Abuse Motion-Activated Lighting Product

Pictogram Exit Signs Catalogue

NEMA-4X Series. Certified for Harsh Environment Applications

VIENTO MEDIUM AREA & SITE LED LUMINAIRE OPTICS

FHSAC1-UNV-40L INSTALLATION INSTRUCTIONS

SECTION INTERIOR LIGHTING

I-320 SERIES AC EMERGENCY LIGHTING EQUIPMENT

Distributor Select LED Families

PSO Business Rebates Retrofit Lighting Technical Requirements

LED RETROFIT CONVERSION KITS

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

New LED Product Offerings

SECTION LIGHTING

Grüv Flare Regressed. Recessed Linear LED

RES West Coast Valued Partner Meeting September 27, 2018 Joe Calnan RES National Account Manager

LED RETROFIT SOLUTIONS

BAS SFP22 Edge-lit LED Panel

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL

Grüv Flare Regressed. Recessed Linear LED

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions

Metalux SWLED LED. Type. Catalog # Project. Date. Comments. Prepared by

SECTION INTERIOR LIGHTING

TROFFER RETROFIT KIT (TRK)

THE UNITED LIGHTING GROUP

DHL-LP-LED Low Profile LED Linear High/Low Bay

LED FIXTURE CATALOG. Shining light into the future

LiteMinder. LM Series Inverter Pure Sine Wave Modular Inverter Technology. Fast Transfer System 1.0 to 18.75KVA LED Compatible

Bdl60u Fluorescent Emergency Ballast

Sure-Lites. 13" [330mm] 3 1/8" [80mm] 4 3/4" [121mm] Emergency Light w/remote Capacity SEL SERIES

LED lighting for light industrial areas IHB series high bay LED luminaires. IHB series. High bay LED luminaires for light industrial areas

Hazardous Location LED String Lights - 5 Jelly Jar Lamps - Non Metallic - Chemical Resistant - CID2

A REA L IGHTING A DIFFERENT WAY OF LIGHT

TRMUNV220ACXXXA UNIVERSAL VOLTAGE HIGHBAY RETROFIT KIT

Step Lighting. For indoor and outdoor, stair and pathway applications. Juno Lighting Group Juno Step Lighting 1

Project. Comments. Prepared by

Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs

Lighting Solutions. from a Leader in Light Source Technology

Alliance 4 - ALI4 LED 4 Linear High Bay

UNIFIED FACILITIES GUIDE SPECIFICATIONS

80W C1D2 Hazardous Location Integrated LED - Corrosion Resistant for Marine - Emergency Backup

LED Family Series. Low energy and low maintenance for moderate budget application LIFE SAFETY EQUIPMENT

CPPG ENERGY EFFICIENT CANOPY LIGHTS FOR PARKING AREAS

THE COMPLETE GUIDE TO OUTDOOR WALL LIGHTS

Parking Garage. Lighting & Control Solutions SLGUS.COM

LUMINAIRE ID SIZE CENTER OPTICS SIDE OPTICS LIGHT SOURCE CRI LUMEN PACKAGES COLOR TEMP. VOLTAGE. LED - high performance LED 80-80CRI 90-90CRI

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

Evolve LED Garage Light

CONTENTS LITHONIA EMERGENCY SYSTEMS

LED RETROFIT CONVERSION KITS

Essentials Series 4.0

LHB LED High Bay. Technical Specifications. Description. Performance Data. Dimensions & Weights. Delivered Lumens Efficacy.

LED HIGH BAY LINEAR HL SERIES

Outdoor Emergency Lighting Application Guide

POINT HELIDECK LIGHTS PRL-LSM LED LOW SURFACE MOUNT LIGHT

Truss Surface SURFACE

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

But act fast: your order must be received by December 21st and ship by December 28th. Order quantity limited to supply in stock.

Surface Mount Series Luminaires

MN/DOT Specification Sign Lighting Luminaire With 150 or 250 Watt Metal Halide Lamps 11/05/09

CALIBER LIGHTING. SERIES 4VDWWL Shower Lens LED Dim-to-Warm Recessed Downlight, 1018 Lumen APPLICATION PRODUCT DATA. 4VLEDWL Example: 4VLEDWLSCLPF

EVT4 Series. LED & Fluorescent Technology

110 lm w STANDARD SERIES

LMV Series W Low Profile - Medium Base

Introduction. Emergency Systems Synergy Control Systems. Lithonia Emergency Systems E3 - E16 Lithonia Synergy Control SS1 - SS9.

Fino Healthcare. Asymmetric Wall Mount Indirect LED

GREENLITE.CA ACT.NOW.FOREVER GREENLITEUSA.COM 2018 LIGHTING PRODUCT CATALOG GREENLITEUSA.COM

BALLAST SOURCE EB- Electronic ballast BALLAST QUANTITY. 1-(1) 4-light ballast LAMP SPECIFICATIONS SPECIFICATIONS

Product Catalogue. Specialist in Emergency Lighting and Exit Sign

A. Furnish and install luminaires, lamps, ballasts and in-line fuses as herein specified and shown on the Drawings.

Transcription:

Exit/Emergency Lighting Guide 1

Exit/Emergency Lighting Guide Table of Contents Exit Signs... 3 Exit/Emergency Combo... 5 Emergency Lights... 7 Accessories... 14 Emergency Ballasts... 17 2

HL0301 Compact Thermoplastic Exit Sign Mounting EZ-snap mounting canopy included for top or end mount. Universal knockout pattern on back plate for wall mount. Housing Injection-molded, engineering grade, 5VA flame retardant, high-impact resistant, thermoplastic. Aesthetically pleasing, curved face, rounded corner design. EZ snap-out Chevron directional indicators. Illumination Ultra bright, energy efficient, long life Red or Green LEDs. Electrical Dual 120/277 voltage. Charge rate/power ON LED indicator light and push-totest switch for mandated code compliance testing. 1.2V Long life, maintenance-free, rechargeable NiCd battery (EM models only). Internal solid-state transfer switch automatically connects the internal battery to LED board for minimum 90-minute emergency illumination. Fully automatic solid-state, two rate charger initiates battery charging to recharge a discharged battery in 24 hours. Warranty & Listings Five year warranty on all electronics and housing. Battery prorated for five years. Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. UL Listed for damp locations (0 C 50 C). Certified to CEC under Title 20 Regulations. 4 5 /16 7 7 Sample Ordering Information HL0301B2RW Battery Backup Double Face Red Letters White Housing 11 1 Ordering Information Model Operation Number of Faces Letter Color Housing Color HL0301 Blank: AC Only B: Battery Backup 2: Double Face R: Red G: Green W: White Page 1 of 1 Rev: 3/1/2019 3

HL0330 All LED Exit & Emergency Lightpipe Thermoplastic Combo Mounting EZ-snap mounting canopy included for top or end mount. Universal knockout pattern on back plate for wall mount. Housing Injection-molded, engineering grade, 5VA flame retardant, high-impact resistant, thermoplastic in white finish. Aesthetically pleasing, curved face, rounded corner design. EZ snap-out Chevron directional indicators. Illumination Ultra bright, energy eff icient white LED emergency lighting. 4.5 watt (36 LEDs x 0.125 watts) per light pipe. Adjustable high performance, smooth, chrome-plated, metallized ref lector and acrylic, UV-stabilized Light Pipe lens for optimal light distribution. Long life, energy eff icient Red or Green LED EXIT sign illumination. Warranty & Listings Five year warranty on all electronics and housing. Battery prorated for five years. Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. UL Listed for damp locations (0 C 50 C). Certified to CEC under Title 20 Regulations. Electrical Dual 120/277 voltage. Charge rate/power ON LED indicator light and push-totest switch for mandated code compliance testing. 4.8V long life, maintenance-free, rechargeable NiCd battery. Remote capacity of 3.0 watts standard. Internal solid-state transfer switch automatically connects the internal battery to LED board and LED Light Pipe for minimum 90-minute emergency illumination. Fully automatic solid-state, two rate charger initiates battery charging to recharge a discharged battery in 24 hours. 4 9 Ordering Information Model Number of Faces Letter Color Housing Color Options HL0330 2: Double Face R: Red W: White Powder Coated Blank: None SDT: Self Diagnostic Page 1 of 1 Rev: 3/1/2019 4

HL0314 All LED Exit & Emergency Thermoplastic Combo Electrical Dual 120/277 voltage. Charge rate/power ON LED indicator light and push-totest switch for mandated code compliance testing. 9.6V Long life, maintenance-free, rechargeable NiCd battery. Internal solid-state transfer switch automatically connects the internal battery to LED board and LED lamp heads for minimum 90-minute emergency illumination. Fully automatic solid-state, two rate charger initiates battery charging to recharge a discharged battery in 24 hours. Electrical Data Input Watts (W) Catalog Number Illumination Long lasting, eff icient ultra bright white LED lamp heads. 1.0 watt (8 LEDs x 0.125W) per head. High performance chrome-plated metallized ref lector and plastic lens for optimal light distribution. Adjustable LED lamp heads provides optimal centertocenter spacing. Long life, energy efficient Red or Green LED EXIT sign illumination. Mounting EZ-snap mounting canopy included for top or end mount. Universal knockout pattern on back plate for wall mount. Housing Input Amps (A) 120V 277V 120V 277V HL0314 (Red Letters) 3.7 3.8 0.040 0.020 HL0314 (Green Letters) HL0314 (Red Letters) - RC 3.0 3.2 0.030 0.014 HL0314 (Red Letters) - RC 3.4 3.6 0.033 0.015 Warranty & Listings Five year warranty on all electronics and housing. Battery prorated for five years. Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. UL Listed for damp locations (0 C 40 C). Certified to CEC under Title 20 Regulations. Injection-molded, engineering grade, 5VA flame retardant, high-impact resistant, thermoplastic in white finish. EZ snap-out Chevron directional indicators. 45/16 8 Sample Ordering Information HL03143RWRC Red Letters White Housing Remote Capable 8 12 205/16 Ordering Information Model Number of Faces HL0314 3: Universal Letter Color R: Red G: Green Housing Color W: White Options Blank: None *RC: Remote Capable *Compatible only with Howard HLRHLED remote heads (click here). 5 Page 1 of 1 Rev: 3/5/2019

HL0409 Thermoplastic Combo LED Electrical Data Features Long life, energy saving LED lamps Injection-molded, high impact thermoplastic construction Snap-fit faceplate installs without the use of tools Field replacement chevron directional indicator knockouts Integral wiring channels to facilitate installation Universal mounting pattern knockout in back plate for J-box mounting Universal single face and double face (extra faceplate included) Snap-fit canopy (included) enables speedy top mounting Fully adjustable glare-free lighting heads, white housing is standard, with an optional black housing available Dual-voltage input 120V or 277V AC Operation Emergency unit provided with test switch, status indicator and rechargeable battery Maintenance-free, 6V sealed lead-acid battery, provides 90 minutes of emergency power Two 5.4W DC 5 wedge-base lamps for emergency light Typical Performance Red/Green Input Voltage 120 277 Input Currant (ma) 62 29 Input Power (W) 6.8 7.2 Power Factor (%) >0.9 >0.9 Current THD (%) <20 <20 Ordering Information Model Number of Faces Letter Color Housing Color HL0409 3: Universal Single/Double Face R: Red G: Green W: White Coated Page 1 of 1 Rev: 3/4/2019 6

HL0202L-W LED Thermoplastic Emergency Unit Housing Injection-molded, engineering grade, 5VA flame retardant, high-impact resistant, thermoplastic in white. Warranty & Listings Five year warranty on all electronics and housing. Batteries prorated for five years. UL (standard)/csa (optional) listed for damp locations 0 C 50 C). Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. Illumination Long lasting, efficient, ultra bright white LED lamp heads. 1.0 watt (8 LEDs x 0.125 watt) per head. High performance chrome-plated metallized reflector and plastic lens for optimal light distribution. Adjustable LED lamp heads provide optimal center-tocenter spacing. Electrical Dual 120/277 voltage standard. Charge rate/power ON LED indicator light and push-totest switch for mandated code compliance testing. 3.6V long life, maintenance-free, rechargeable NiCd battery. Internal solid-state transfer switch automatically connects the internal battery to LED lamp heads for minimum 90-minute emergency illumination. Fully automatic solid-state, two rate charger initiates battery charging to recharge a discharged battery in 24 hours. 5 Mounting Universal knockout pattern on back plate for surface mount. Snaps into place making internal electrical connections. Suitable for wall or ceiling mount. Knockout for conduit applications. 4 9 /16 3 11 /16 Ordering Information Model Number HL0202L-W Color White 12 10 1 /16 7 Page 1 of 1 Rev: 3/1/2019

LED Adjustable Optics Thermoplastic Emergency Unit HL0223L-W Mounting Universal knockout pattern on back plate for surface mount. Snaps into place making internal electrical connections. Suitable for wall or ceiling mount. Knockout for conduit applications. Housing Injection-molded, engineering grade, 5VA flame retardant, high-impact resistant, thermoplastic in white. Warranty & Listings Illumination Five year warranty on all electronics and housing. Batteries prorated for five years. UL (standard)/csa (optional) listed for damp locations 0 C 50 C). Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. Long life, efficient, ultra bright white LED lamp heads. 1.0 watt (8 LEDs x 0.125W) per head. High performance, chrome-plated metallized reflector and plastic lens for optimal light distribution. Two adjustable LED lamp heads provide optimal centerto-center spacing. Electrical Dual 120/277 voltage standard. Charge rate/power ON LED indicator light and push-totest switch for mandated code compliance testing. 3.6V long life, maintenance-free, rechargeable NiCd battery. Internal solid-state transfer switch automatically connects the internal battery to LED lamp heads for minimum 90-minute emergency illumination. Fully automatic solid-state, two rate charger initiates battery charging to recharge a discharged battery in 24 hours. Ordering Information Model Number Color HL0223L-W White 8 Page 1 of 1 Rev: 3/1/2019

HL0435 Thermoplastic Micro Adjustable Emergency Lights Features Energy Saving LED Fully adjustable, glare-free lamp heads Contemporary design UL924 listed for damp location Injection-molded, high impact, UV stabilized, thermoplastic construction Dual 120V/277V voltage Maintenance free nickel cadmium battery Universal mounting plate with quickconnect feature Universal J-box pattern knock out Ordering Information Model Number Housing Color HL0435W White Page 1 of 1 Rev: 3/1/2019 9

HL0202SW Incandescent Thermoplastic Emergency Unit Mounting Universal knockout pattern on back plate for wall mount. Snaps into place making internal electrical connections. Knockout for conduit applications. Housing Injection-molded, engineering grade, 5VA flame retardant, high-impact resistant, thermoplastic in white or black finish. Illumination Two fully adjustable 5.4 watt glare-free lamp heads. Smooth thermoplastic reflector and plastic lens for optimal light distribution. Warranty & Listings Five year warranty on all electronics and housing. Batteries prorated for two years. Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. Meets CSA C22.2 No. 141-02 Requirements for unit equipment. UL listed for damp locations (20 C 50 C). Electrical Dual 120/277 voltage. Charge rate/power ON LED indicator light and push-totest switch for mandated code compliance testing. LVD (low voltage disconnect) prevents battery from deep discharge. 6V maintenance-free, rechargeable sealed lead acid battery. Internal solid-state transfer switch automatically connects the internal battery to lamp heads for minimum 90-minute emergency illumination. Fully automatic solid-state, two rate charger initiates battery charging to recharge a discharged battery in 24 hours. 4 9 /16 Ordering Information Model Number HL0202SW Color White 16 10 Page 1 of 1 Rev: 3/1/2019

HL024 High Wattage HL024 Series Incandescent Remote Capable Thermoplastic Emergency Unit Illumination Adjustable, glare-free PAR-Type lamp heads with 9 watt incandescent lamp heads. Mounting Universal knockout pattern on back for wall mount. Knockouts for conduit feed applications. 14 13 /16 Electrical Dual 120/277 voltage. Charge rate/power ON LED indicator light and push-totest switch for mandated code compliance testing. LVD (low voltage disconnect) prevents battery from deep discharge. Internal solid-state transfer switch automatically connects the internal battery to lamp heads for minimum 90-minute emergency illumination. Fully automatic solid-state, two rate charger initiates battery charging to recharge a discharged battery in 24 hours. Electrical Data Catalog Number Input Watts (W) Input Amps (A) 120V 277V 120V 277V HL0242 19.6 23.4 0.178 0.093 HL0243 29.3 33.5 0.273 0.131 Warranty & Listings Five year warranty on all electronics and housing. Battery prorated for two years. Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. UL Listed for dry locations (25 C). 50 Watt Unit 100 Watt Unit Housing Injection-molded, engineering grade, 5VA f lame retardant, high-impact thermoplastic construction. Ordering Information Model 5 Rated Output Watts Lamp Remote Capability Total Connected Heads/Fixtures Voltage 1.5 hrs. 2 hrs. 4 hrs. 8 hrs. Wattage 4 hrs. 2 hrs. 1.5 hrs. HL0242 50 37 18-2* 3* 5* 2x9W 12V HL0243 100 75 37 18 4* 7* 10* * Based on 9 watt lamps, standard 11 Page 1 of 1 Rev: 3/29/2019

Decorative Outdoor LED AC/Emergency Light Date: HLDBEL Mounting Surface mount via easy-connect back plate that fits most standard size junction boxes. Universal K/O pattern on back plate for wall mount. Threaded opening at the top of the enclosure for conduit mount. Illumination Long life, efficient, ultra bright white LED. 12W (2 LEDs x 6.0 watt) per unit. Mirror-bright reflector and prismatic polycarbonate refractor. Can be used as a Normally-ON or Normally-OFF light as well as on a switched circuit. Provides 1286 lumens in AC mode and 350 lumens in EM mode. Electrical Universal 120-277VAC voltage. Charge rate/power ON LED indicator light and push-to test switch for mandated code compliance testing. 4.8V long life, maintenance-free, rechargeable NiCd battery. Internal solid-state transfer switch automatically connects the internal battery to LED board for minimum 90-minute emergency illumination. Fully automatic solid-state, two rate charger initiates battery charging to recharge a discharged battery in 24 hours. Self-diagnostic test feature continually diagnoses unit performance and tests system to ensure reliable operation and to meet electrical and life safety codes. Field-selectable wiring allows for AC operation of the unit to be controlled using a wall switch, a photocell, or any other switching mechanism. Photocell sensor included as a standard for use as dusk-to-dawn light. Housing Decorative, Low Profile, architectural design. Die-cast aluminum housing. Durable powder-coated finish. Sealed and gasketed. Certifications Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. UL Listed for wet locations (0 C 50 C). Options CW: Optional internal heater for extreme cold temperature applications (-30 C 50 C). Ordering Information Model Family Housing Color Options HLDBEL BR - Dark Bronze Blank - None CW - Cold Weather 6 9 /16 Sample Ordering Information Howard HLDBELB 12W 120-277 volts Bronze Housing 3-5/8 Page 1 of 1 Rev: 3/1/2019 12

HLRMR-16W MR-16 Semi-Recessed Thermoplastic Emergency Unit Mounting Universal knockout pattern on back plate for surface mount. Snaps into place making internal electrical connections. Knockout for conduit applications. Housing Injection-molded, engineering grade, 5VA flame retardant, high-impact resistant, thermoplastic in white. Illumination Two fully adjustable, semi-recessed ultra bright, 7.0 watt, MR-16 halogen lamp heads standard. High performance MR16 halogen lamps with smooth metallized reflector and glass lens for optimal light distribution. Electrical Dual 120/277 voltage. Charge rate/power ON LED indicator light and push-totest switch for mandated code compliance testing. LVD (low voltage disconnect) prevents battery from deep discharge. 6V maintenance-free, rechargeable sealed lead acid battery. Internal solid-state transfer switch automatically connects the internal battery to lamp heads for minimum 90-minute emergency illumination. Fully automatic solid-state, two rate charger initiates battery charging to recharge a discharged battery in 24 hours. 3 Warranty & Listings Five year warranty on all electronics and housing. Battery prorated for two years. Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. UL Listed for damp locations (20 C 40 C). Ordering Information Model Number Color Emergency Operations Number if Lamp Heads/Lamp Wattage Battery Voltage HLRMR-16 W: White 90+ minutes 2x 6V/7W 6V 13 Page 1 of 1 Rev: 3/1/2019

HL0202-BATT Rechargeable Sealed Lead Acid Battery Application For use with lighting equipment, communications and electrical equipment, emergency lighting equipment and fire alarm & security systems. Features Valve-regulated and safe to discharge in any position. Completely sealed and maintenance free, low selfdischarge. Impact-resistant ABS housing. Will last up to 5 years in standby applications and 200 to 1,000 cycles in cyclic applications depending on depth of discharge. Available in a variety of sizes and amp ratings. Provides reliable power output in a variety of applications, resulting in greater eff iciency and improved ability to recover from deep discharge. Cycle or standby use. Low resistance safety feature makes the batteries easy to recharge & maximizes energy output. Standard F1 or F2 f lat lugs type terminal. Ordering Information Model Number Nominal Voltage Nominal Current Weight (lbs) HL0202-BATT 6V 4.5 Amp-Hr 1.6 Page 1 of 1 Rev: 3/1/2019 14

HLRHLED LED Outdoor Polycarbonate / Die-cast Remote head Housing Available in both engineering grade, high-impact resistant polycarbonate or premium grade die-cast aluminum housing. Sealed and gasketed in standard gray or black finish. Warranty & Listings Five year warranty. UL Listed with approved Best Lighting Products. Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. Fixture Compatability Illumination Long lasting, efficient, ultra bright white LED lamp heads. 1.0 watt (8 LEDs x 0.125 watt) per head. High performance chrome-plated metalized reflector and plastic lens for optimal light distribution. Adjusta ble LED lamp heads provide optimal centertocenter spacing. HL0314 (click here) Electrical Powered from low voltage power source with low voltage wiring (not provided). 10 Mounting Universal mounting adapter plate included. Mounts to single-gang switch box. Distance of maximum run is determined by system voltage, wire gauge and total maximum wattage on the run. Suitable for wall or ceiling mount. 6 Ordering Information Model Weatherproof Number of Heads Housing Housing Color Lamp Type* HLRHLED1-PWP-CLPCXTE 1 Yes HLRHLED2-PWP-CLPCXTE 2 Polycarbonate Gray 8 LEDs 1W *Wattage rating stated per head. 15 Page 1 of 1 Rev: 3/5/2019

HLWG HLWG Series Exit/Emergency Wire Guards Features Durable 9-gauge steel construction. Mounting hardware provided for easy field installation. 6 HLWG1 Features Durable 9-gauge steel construction. Mounting hardware provided for easy field installation. HLWG2 6 30 Ordering Information Model Number For use with* HLWG1 Emergency Lights and Exit Signs 13.5 x 15 x 6 HLWG2 Combo Units 13 x 30 x 6 *Exceptions will apply, consult factory before ordering 16 Page 1 of 1 Rev: 3/1/2019

HL-BLEDEM-CP Constant-Power Emergency LED Driver Warranty & Listings UL Classified for factory or field installation. Suitable for damp locations (0 C - 50 C). 5 year warranty on all electronics and housing. Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State codes. Illumination Provides constant power output to the load during emergency mode operation. Can be operated as NORMALLY-ON, NORMALLY-OFF or SWITCHED LOAD. Electrical Universal 120-277V, 50/60 Hz input. Charge/Power ON LED indicator light and push-to-test switch for mandated code compliance testing. Long-life, maintenance free, rechargeable NiCad battery. Output short/overcurrent protection: Electronic limiting, with normal operation resuming upon removal of fault. 90 Minute minimum emergency operating time over full temperature range (other run times available upon request). Output classification: Class 2 Compliant. Surge protection: Per C62.41 (TVS). Input overcurrent protection: Fusible link. 24 Hour maximum battery recharge time. Housing LED illuminated and remote mounted test switch. Injection-molded, engineering grade, 5VA flame retardant, high-impact resistant, thermoplastic in a black finish. HL-BLEDEM-CP-800 HL-BLEDEM-CP-1200 & 1600 HL-BLEDEM-CP-2000 & 2400 Mounting Suitable for installation inside, on top, or in remote mount of the fixture. Ordering Information Model Output Operating Range Constant Output Power Voltage (Vdc) Current (madc) (Watts) (Lumens) HL-BLEDEM-CP-800 20-50 250-100 5.0 800 HL-BLEDEM-CP-1200 20-50 390-156 7.8 1200 HL-BLEDEM-CP-1600 20-50 535-214 10.7 1600 HL-BLEDEM-CP-2000 20-50 685-274 13.7 2000 HL-BLEDEM-CP-2400 20-50 850-340 17.0 2400 Lumen output based on LED light source having efficacy of 160 lumens/watt. Actual output may vary depending on light source utilized. Provides regulated power from 5.0 watts to 17.0 watts (800 to 2400 lumens) 17 Page 1 of 2 Rev: 6/8/2018

HL-BLEDEM-CP BLEDEM-CP Series System Coordination Guidelines These guidelines were developed to allow the lighting system Designer/Specifier to predict the operating performance levels of LED luminaires when powered by an electrically compatible BLEDEM-CP Series model. It is ultimately the responsibility of the Designer/Specifier to insure that the as installed system delivers codecompliant path of egress illumination. 1) Determine Electrical Compatibility A) Verify that the Luminaire LED Driver, where applicable, is Class 2 compliant. B) Verify that the Luminaire LED Lamp(s) have an operating voltage between 20Vdc and 50Vdc. C) Verify that the Luminaire LED Lamp(s) have a power rating equal to, or greater than, the emergency power rating of the BLEDEM-CP model under consideration (please refer to Table 1). 2) Calculate Lumen Output During Emergency Operation A) Access luminaire data by logging onto Designlights Consortium (www.designlights.org). B) Select Search the DLC Qualified Product List on the DLC homepage. C) Enter manufacturer name and P/N of luminaire under consideration in the search by keyword text window. D) Select Search tab to open the Qualified Products List. E) Determine luminaire Lumens per Watt efficacy in Rated Data specifications. F) Multiply luminaire Lumens per Watt by Emergency Output of the HL-BLEDEM-CP model under consideration (please refer to table 1). This figure is the Lumens available from the luminaire during emergency operation. 3) Determine Suitability of Means of Egress Lighting Levels Using industry standard lighting design software, along with IES files for the luminaire under consideration, verify that the as installed available Lumens (as calculated in 2F above) are sufficient to meet Code-compliant path of egress illumination levels. While the HL-BLEDEM-CP series has been found compliant with the requirements of UL Standard 924, it is ultimately the responsibility of the Designer/Specifier to assure the as-installed system delivers code-compliant path of egress illumination in accordance with Federal, State or local municipal requirements. Table 1 Model Output Power (constant) HL-BLEDEM-CP-800 5.0 Watts HL-BLEDEM-CP-1200 7.8 Watts HL-BLEDEM-CP-1600 10.7 Watts HL-BLEDEM-CP-2000 13.7 Watts HL-BLEDEM-CP-2400 17.0 Watts Page 2 of 2 Rev: 6/8/2018 18

BAL3000TD Fluorescent Emergency Ballast 3000 Lumens Illumination Works with or without an AC ballast to convert new or existing fluorescent fixtures in to unobtrusive emergency lighting. Operates one lamp in the emergency mode for a minimum of 90-minutes. Provides a maximum initial lumen output of 3000 lumens. Warranty & Listings Five year warranty against defects in material and workmanship (lamps excluded). Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. UL Listed for damp locations (0 C 50 C). Suitable for use in sealed and gasketed fixtures. Lamp Compatibility Compatible with most one-, two-, three-, and four-lamp electronic standard and dimming AC ballasts. Operates one or two T5, T5HO, T8, T12, T8HO, T12HO, Circular T5/T9, U-bend T8/T12, 4-Pin CFL and long CFL lamps in emergency mode. Refer to the chart on the next page for a complete list of compatible lamps. Electrical Dual 120/277 voltage. Charge rate/power ON LED indicator light and push-totest switch for mandated code compliance testing. 2.4v long life, maintenance-free, rechargeable sealed NiCd battery. Internal solid-state transfer switch automatically connects the internal battery to fluorescent lamp(s) for minimum 90-minute emergency illumination. Fully automatic solid-state, two rate charger initiates battery charging to recharge a discharged battery in 24 hours. Time delay enhancement to overcome end-of-life circuitprotection. Mounting Suitable for installation inside, on top or in remote* of the fixture. Can be used in both switched and unswitched fixtures. UL Listed for factory or field installation. 16.4 16.3 1.75 5.6 5.5 Housing Durable painted steel construction in white finish. Provided with 2 flex conduit. * When battery packs are remote mounted, the remote distance cannot exceed ½ of the distance from ballast to lamp specified by the A.C. ballast manufacturer. The maximum allowable remote mounting distance is 50 feet. 19 Page 1 of 2 Rev: 10/27/2017

BAL3000TD Fluorescent Emergency Ballast 3000 Lumens Electrical Information CATALOG NUMBERI NPUT WATTS (W)I NPUT AMPS (A) BAL3000TD 120V 277V 120V 277V 3.7 4.0 0.27 0.25 Lamp Compatibility Chart LAMP TYPEW ATTS INITIAL LUMENS 1-Lamp2 -Lamp T5 14 1150 1200 T5 21 1650 1750 T5 28 2250 2400 T5 35 2700 2800 T5HO2 4 1750 1850 T5HO3 9 2650 2750 T5HO5 4 2900 3000 T8 17 1150 1200 T8 25 1650 1800 T8 28 1700 1800 T8 32 2850 2900 T8 40 2900 2950 T8HO4 4 2900n /a T8 51 3000n /a T8 59 3000n /a T8HO8 6 2950n /a T122 09 00 950 T122 51 100 1200 T123 0 1550 1600 LAMP TYPEW ATTS INITIAL LUMENS 1-Lamp2 -Lamp T123 4 1700 1800 T124 0 2250 2400 T127 5 2950n /a T128 5 3000n /a T12HO9 5 3000n /a T12HO1 10 3000n /a T12HO1 60 3000n /a T12HO2 15 3000n /a CFL G24q-1 13 825 900 CFL G24q-2 18 925 1000 CFL G24q-3 21 10251 100 CFL G24q-3 26 1250 1300 CFL G24q-3 32 1575 1700 CFL G24q-4 42 1750 1850 CFL G24q-5 57 2350n /a CFL 2G11 18 1100 1200 CFL 2G11 24 1350 1400 CFL 2G11 36 1650 1800 CFL 2G11 40 1750 1850 CFL 2G11 36 1650 1800 LAMP TYPEW ATTS INITIAL LUMENS 1-Lamp2 -Lamp CFL 2G11 40 1750 1850 CFL 2G11 50 2200 2300 CFL 2G11 55 2450n /a CFL 2G11 80 2750n /a CFL GR10q-41 05 75 650 CFL GR10q-41 67 75 900 CFL GR10q-42 1 1050 1200 CFL GR10q-42 8 1450 1550 CFL GR10q-43 8 1675 1800 CFL GR10q-45 5 2350 2500 Circular T92 07 50 800 Circular T93 21 100 1250 Circular T94 0 1450 1600 Circular T52 2 1400 1550 Circular T54 0 1650 1800 Circular T55 5 2250 2400 U-bend T83 21 100 1200 U-bend T12 34 10251 100 U-bend T12 40 975 1050 NOTE: In 2-lamp operation, lumens are equally split between the two lamps. Page 2 of 2 Rev: 10/27/2017 20

BAL500 Fluorescent Emergency Ballast 500 Lumens Illumination Works with or without an AC ballast to convert new or existing fluorescent fixtures in to unobtrusive emergency lighting. Operates one lamp in the emergency mode for a minimum of 90-minutes. Provides a maximum initial lumen output of 500 lumens. Warranty & Listings Five year warranty against defects in material and workmanship (lamps excluded). Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. UL Listed for damp locations (0 C 50 C). Suitable for use in sealed and gasketed fixtures. Lamp Compatibility Compatible with most one-, two-, three-, and four-lamp electronic standard and dimming AC ballasts. Operates one T5, T5HO, T8, T12, Circular T5/T9, U-bend T8/ T12, 4-Pin CFL and long CFL lamp in emergency mode. Refer to the chart on the next page for a complete list of compatible lamps. Electrical Dual 120/277 voltage. Charge rate/power ON LED indicator light and push-totest switch for mandated code compliance testing. 2.4v long life, maintenance-free, rechargeable sealed NiCd battery. Internal solid-state transfer switch automatically connects the internal battery to fluorescent lamp(s) for minimum 90-minute emergency illumination. Fully automatic solid-state, two rate charger initiates battery charging to recharge a discharged battery in 24 hours. Time delay enhancement to overcome end-of-life circuitprotection. Mounting Suitable for installation inside, on top or in remote* of the fixture. Can be used in both switched and unswitched fixtures. UL Listed for factory or field installation. 9.4 5 2.4 1.5 Housing Durable painted steel construction in white finish. Compact design fits most fluorescent fixtures. * When battery packs are remote mounted, the remote distance cannot exceed ½ of the distance from ballast to lamp specified by the A.C. ballast manufacturer. The maximum allowable remote mounting distance is 50 feet. 21 Page 1 of 2 Rev: 03/21/2019

BAL500 Fluorescent Emergency Ballast 500 Lumens Electrical Information CATALOG NUMBERI NPUT WATTS (W)I NPUT AMPS (A) BAL500TD 120V 277V 120V 277V 2.5 2.7 0.27 0.25 Lamp Compatibility Chart LAMP TYPE WATTS INITIAL LUMENS 1-Lamp T5 21 450 T5 28 500 T5HO2 4 475 T8 25 375 T8 28 425 LAMP TYPE WATTS INITIAL LUMENS 1-Lamp T8 32 500 T122 5 400 T123 0 425 T123 4 450 CFL 2G11 36 375 LAMP TYPE WATTS INITIAL LUMENS 1-Lamp Circular T9 20 325 Circular T9 32 350 Circular T5 22 375 U-Bend T8 32 425 U-Bend T12 34 375 22 Page 2 of 2 Rev: 03/21/2019

BAL700TD BAL700TD Fluorescent Emergency Ballast 700 Lumens Illumination Works with or without an AC ballast to convert new or existing fluorescent fixtures in to unobtrusive emergency lighting. Operates one or two lamps in the emergency mode for a minimum of 90-minutes. Provides a maximum initial lumen output of 700 lumens. Warranty & Listings Five year warranty against defects in material and workmanship (lamps excluded). Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. UL Listed for damp locations (0 C 50 C). Suitable for use in sealed and gasketed fixtures. Lamp Compatibility Compatible with most one-, two-, three-, and four-lamp electronic standard and dimming AC ballasts. Operates one or two T5, T5HO, T8, T12, T8HO, T12HO, Circular T5/T9, U-bend T8/T12, 4-Pin CFL and long CFL amps in emergency mode. Refer to the chart on the next page for a complete list of compatible lamps. Electrical Dual 120/277 voltage. Charge rate/power ON LED indicator light and push-totest switch for mandated code compliance testing. 3.6V long life, maintenance-free, rechargeable sealed NiCd battery. Internal solid-state transfer switch automatically connects the internal battery to fluorescent lamp(s) for minimum 90-minute emergency illumination. Fully automatic solid-state, two rate charger initiates battery charging to recharge a discharged battery in 24 hours. Time delay enhancement to overcome end-of-life circuitprotection. Mounting Suitable for installation inside, on top or in remote* of the fixture. Can be used in both switched and unswitched fixtures. UL Listed for factory or field installation. 9.4 5 2.4 1.5 Housing Durable painted steel construction in white finish. Compact design fits most fluorescent fixtures. * When battery packs are remote mounted, the remote distance cannot exceed ½ of the distance from ballast to lamp specified by the A.C. ballast manufacturer. The maximum allowable remote mounting distance is 50 feet. 23 Page 1 of 2 Rev: 10/27/2017

BAL700TD BAL700TD Fluorescent Emergency Ballast 700 Lumens Electrical Information CATALOG NUMBERI NPUT WATTS (W)I NPUT AMPS (A) BAL700TD 120V 277V 120V 277V 2.9 3.1 0.27 0.25 Lamp Compatibility Chart LAMP TYPEW ATTS INITIAL LUMENS 1-Lamp2 -Lamp T5 21 575 650 T5 28 675n /a T5 35 700n /a T5HO2 46 50 n/a T5HO3 97 00 n/a T5HO5 47 00 n/a T8 25 625 700 T8 28 630 600 T8 32 600 700 T8 40 650 700 T8HO4 46 25 n/a T8 51 675n /a T8 59 700n /a LAMP TYPEW ATTS INITIAL LUMENS 1-Lamp2 -Lamp T8HO 86 700n /a T122 54 50 500 T123 05 00 550 T123 45 75 600 T124 06 25 650 T127 56 75 n/a T128 57 00 n/a T12HO9 57 00 n/a T12HO1 10 700n /a CFL G24Q-5 57 675n /a CFL 2G11 36 600 700 CFL 2G11 40 625n /a CFL 2G11 50 650n /a LAMP TYPEW ATTS INITIAL LUMENS 1-Lamp2 -Lamp CFL 2G11 55 675n /a CFL GR10q-42 85 50 600 CFL GR10q-43 86 50 n/a CFL GR10Q-4 55 700n /a Circular T92 04 00 500 Circular T93 24 50 550 Circular T94 05 00 n/a Circular T52 24 25 550 Circular T54 06 00 700 Circular T55 56 50 n/a U-bend T83 25 75 675 U-bend T12 34 550 650 U-bend T12 40 600n /a NOTE: In 2-lamp operation, lumens are equally split between the two lamps. 24 Page 2 of 2 Rev: 10/27/2017

BALT5-1300TD Low Profile T5 Fluorescent Emergency Ballast 1300 Lumens Illumination Works with or without an AC ballast to convert new or existing fluorescent fixtures in to unobtrusive emergency lighting. Operates one or two lamps in the emergency mode for a minimum of 90-minutes. Provides a maximum initial lumen output of 1300 lumens. Warranty & Listings Five year warranty against defects in material and workmanship (lamps excluded). Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. UL Listed for damp locations (0 C 50 C). Suitable for use in sealed and gasketed fixtures. Lamp Compatibility Compatible with most one-, two-, three-, and four-lamp electronic standard and dimming AC ballasts. Operates one or two T5, T5HO, T8, T12, Circular T5/T9, Ubend T8/T12, 4-Pin CFL and long CFL lamps in emergency mode. Refer to the chart on the next page for a complete list of compatible lamps. Electrical Dual 120/277 voltage. Charge rate/power ON LED indicator light and push-totest switch for mandated code compliance testing. 8.4V long life, maintenance-free, rechargeable sealed NiCd battery. Internal solid-state transfer switch automatically connects the internal battery to fluorescent lamp(s) for minimum 90-minute emergency illumination. Fully automatic solid-state, two rate charger initiates battery charging to recharge a discharged battery in 24 hours. Time delay enhancement to overcome end-of-life circuitprotection. Mounting Suitable for installation inside, on top or in remote* of the fixture. Can be used in both switched and unswitched fixtures. UL Listed for factory or field installation. 21.5 21.5 1.15 1.19 1.28 1.22 Housing Low profile galvanized steel construction. Compact design fits most fluorescent fixtures. * When battery packs are remote mounted, the remote distance cannot exceed ½ of the distance from ballast to lamp specified by the A.C. ballast manufacturer. The maximum allowable remote mounting distance is 50 feet. 25 Page 1 of 2 Rev: 10/27/2017

BALT5-1300TD Low Profile T5 Fluorescent Emergency Ballast 1300 Lumens Electrical Information CATALOG NUMBERI NPUT WATTS (W)I NPUT AMPS (A) BALT5-1300TD 120V 277V 120V 277V 2.7 2.7 0.130 0.130 Lamp Compatibility Chart LAMP TYPEW ATTS INITIAL LUMENS 1-Lamp2 -Lamp T5 14 750 800 T5 21 850 950 T5 28 1100 n/a T5 35 1250n /a T5HO2 48 00 n/a T5HO3 9 1200n /a T5HO5 4 1300n /a T8 17 950 1050 T8 25 10001 100 T8 28 10501 100 T8 32 1150 n/a T8 40 1200n /a T122 08 50 n/a T123 09 75 n/a T123 4 1050n /a T124 0 1200n /a LAMP TYPEW ATTS INITIAL LUMENS 1-Lamp2 -Lamp CFL 2G11 36 1025n /a CFL 2G11 40 1050n /a CFL 2G11 50 1100 n/a CFL 2G11 55 1150 n/a CFL GR10q-42 87 75 850 CFL GR10q-43 89 00 n/a Circular T92 06 00 675 Circular T93 27 50 n/a Circular T94 08 50 n/a Circular T52 29 75 n/a Circular T54 0 1050n /a Circular T55 5 1200n /a U-bend T82 97 25 n/a U-bend T83 27 75 n/a U-bend T12 34 675n /a U-bend T12 40 700n /a NOTE: In 2-lamp operation, lumens are equally split between the two lamps. 26 Page 2 of 2 Rev: 10/27/2017

BALT5-500TD Low ProfileFluorescent Emergency Ballast 500 Lumens Warranty & Listings Five year warranty against defects in material and workmanship (lamps excluded). Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. UL Listed for damp locations (0 C 50 C). Suitable for use in sealed and gasketed fixtures. Lamp Compatibility Compatible with most one-, two-, three-, and four-lamp electronic standard and dimming AC ballasts. Operates one T5, T8, T12, Circular T5/T9 and U-bend T8/T12 lamp in emergency mode. Refer to the chart on the next page for a complete list of compatible lamps. Illumination Works with or without an AC ballast to convert new or existing fluorescent fixtures in to unobtrusive emergency lighting. Operates one lamp in the emergency mode for a minimum of 90-minutes. Provides a maximum initial lumen output of 500 lumens. Electrical Dual 120/277 voltage. Charge rate/power ON LED indicator light and push-totest switch for mandated code compliance testing. 3.6V long life, maintenance-free, rechargeable sealed NiCd battery. Internal solid-state transfer switch automatically connects the internal battery to fluorescent lamp(s) for minimum 90-minute emergency illumination. Fully automatic solid-state, two rate charger initiates battery charging to recharge a discharged battery in 24 hours. Time delay enhancement to overcome end-of-life circuitprotection. Mounting Suitable for installation inside, on top or in remote* of the fixture. Can be used in both switched and unswitched fixtures. UL Listed for factory or field installation. 14.25 14.3 1.25 1.21 1.25 1.28 Housing Low profile galvanized steel construction. Compact design fits most fluorescent fixtures. * When battery packs are remote mounted, the remote distance cannot exceed ½ of the distance from ballast to lamp specified by the A.C. ballast manufacturer. The maximum allowable remote mounting distance is 50 feet. 27 Page 1 of 2 Rev: 10/27/2017

BALT5-500TD Low ProfileFluorescent Emergency Ballast 500 Lumens Electrical Information CATALOG NUMBERI NPUT WATTS (W)I NPUT AMPS (A) BALT5-500TD 120V 277V 120V 277V 2.7 2.7 0.130 0.130 Lamp Compatibility Chart LAMP TYPEW ATTS INITIAL LUMENS 1-Lamp2 -Lamp T5 21 450n /a T5 28 500n /a T8 32 425n /a T123 44 00 n/a Circular T93 23 50 n/a Circular T52 23 75 n/a U-bend T83 24 25 n/a U-bend T12 34 375n /a 28 Page 2 of 2 Rev: 10/27/2017

BALT5-800TD Low Profile T5 Fluorescent Emergency Ballast 800 Lumens Illumination Works with or without an AC ballast to convert new or existing fluorescent fixtures in to unobtrusive emergency lighting. Operates one lamp in the emergency mode for a minimum of 90-minutes. Provides a maximum initial lumen output of 800 lumens. Warranty & Listings Five year warranty against defects in material and workmanship (lamps excluded). Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. UL Listed for damp locations (0 C 50 C). Suitable for use in sealed and gasketed fixtures. Lamp Compatibility Compatible with most one-, two-, three-, and four-lamp electronic standard and dimming AC ballasts. Operates one or two T5, T5HO, T8, T12, Circular T5/T9, Ubend T8/T12, 4-Pin CFL and long CFL lamps in emergency mode. Refer to the chart on the next page for a complete list of compatible lamps. Electrical Dual 120/277 voltage. Charge rate/power ON LED indicator light and push-totest switch for mandated code compliance testing. 6V long life, maintenance-free, rechargeable sealed NiCd battery. Internal solid-state transfer switch automatically connects the internal battery to fluorescent lamp(s) for minimum 90-minute emergency illumination. Fully automatic solid-state, two rate charger initiates battery charging to recharge a discharged battery in 24 hours. Time delay enhancement to overcome end-of-life circuitprotection. Mounting Suitable for installation inside, on top or in remote* of the fixture. Can be used in both switched and unswitched fixtures. UL Listed for factory or field installation. 17.75 17.6 1.25 1.19 1.25 1.28 Housing Low profile galvanized steel construction. Compact design fits most fluorescent fixtures. * When battery packs are remote mounted, the remote distance cannot exceed ½ of the distance from ballast to lamp specified by the A.C. ballast manufacturer. The maximum allowable remote mounting distance is 50 feet. 29 Page 1 of 2 Rev: 10/27/2017

BALT5-800TD Low Profile T5 Fluorescent Emergency Ballast 800 Lumens Electrical Information CATALOG NUMBERI NPUT WATTS (W)I NPUT AMPS (A) BALT5-800TD 120V 277V 120V 277V 2.7 2.7 0.130 0.130 Lamp Compatibility Chart LAMP TYPEW ATTS INITIAL LUMENS 1-Lamp2 -Lamp T5 21 500n /a T5 28 750n /a T5 35 800n /a T5HO2 47 25 n/a T5HO3 97 50 n/a T5HO5 48 00 n/a T8 28 650n /a T8 32 700n /a T8 40 675n /a T124 06 50 n/a CFL 2G11 36 675n /a CFL 2G11 40 675n /a LAMP TYPEW ATTS INITIAL LUMENS 1-Lamp2 -Lamp CFL 2G11 50 725n /a CFL 2G11 55 725n /a CFL GR10q-4 28 500 550 CFL GR10q-4 38 600n /a Circular T93 24 00 n/a Circular T94 04 75 n/a Circular T52 24 25 n/a Circular T54 06 50 n/a Circular T55 57 25 n/a U-bend T83 24 50 n/a U-bend T12 40 400n /a NOTE: In 2-lamp operation, lumens are equally split between the two lamps. Page 2 of 2 Rev: 10/27/2017 30

HL-PAC0006 Fluorescent Emergency Ballast 650 Lumens Illumination Works with or without an AC ballast to convert new or existing fluorescent fixtures in to unobtrusive emergency lighting. Operates one lamp in the emergency mode for a minimum of 90-minutes. Provides a maximum initial lumen output of 750 lumens. Warranty & Listings Five year warranty against defects in material and workmanship (lamps excluded). Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. UL Listed for damp locations (0 C 50 C). Suitable for use in sealed and gasketed fixtures. Lamp Compatibility Compatible with most one-, two-, three-, and four-lamp electronic standard and dimming AC ballasts. Operates one 25W-40W T8 through T12, one 13W-42W 4-pin compact or one 18W-40W 4-pin long compact fluorescent lamps. Refer to lamp compatibility chart for a complete list of lamps. Electrical Dual 120/277 voltage. Charge rate/power ON LED indicator light and push-totest switch for mandated code compliance testing. 3.6V long life, maintenance-free, rechargeable sealed NiCd battery. Internal solid-state transfer switch automatically connects the internal battery to fluorescent lamp(s) for minimum 90-minute emergency illumination. Fully automatic solid-state, two rate charger initiates battery charging to recharge a discharged battery in 24 hours. Time delay enhancement to overcome end-of-life circuitprotection. Mounting Suitable for installation inside, on top or in remote* of the fixture. Can be used in both switched and unswitched fixtures. UL Listed for factory or field installation. Housing Durable painted steel construction in white finish. Provided with 2 flex conduits on both ends. Compact design fits most fluorescent fixtures. 2 * When battery packs are remote mounted, the remote distance cannot exceed ½ of the distance from ballast to lamp specified by the A.C. ballast manufacturer. The maximum allowable remote mounting distance is 50 feet. 31 Page 1 of 2 Rev: 3/29/2019

HL-PAC0006 Fluorescent Emergency Ballast 650 Lumens Electrical Information CATALOG NUMBERI NPUT WATTS (W)I NPUT AMPS (A) 120V 277V 120V 277V BHL-PAC0006 AL650C-4ACTD 3.8 3.8 0.270 0.270 Lamp Compatibility Chart LAMP INITIAL LUMENS 1-LAMP T8 32W 675 T12 40W 650 4-Pin PL CF 13W 450 4-Pin PL CF 18W 500 LAMP INITIAL LUMENS 1-LAMP 4-Pin PL CF 26W 575 4-Pin PL CF 32W 675 4-Pin PL CF 42W 750 LAMP INITIAL LUMENS 1-LAMP 4-Pin Long CF 18W 525 4-Pin Long CF 24W 575 4-Pin Long CF 36W 600 4-Pin Long CF 40W 650 32 Page 2 of 2 Rev: 3/29/2019

PAC0014 Fluorescent Emergency Ballast 1400 Lumens Illumination Works with or without an AC ballast to convert new or existing fluorescent fixtures in to unobtrusive emergency lighting. Operates one lamp in the emergency mode for a minimum of 90-minutes. Provides a maximum initial lumen output of 1400 lumens. Warranty & Listings Five year warranty against defects in material and workmanship (lamps excluded). Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. UL Listed for damp locations (0 C 50 C). Suitable for use in sealed and gasketed fixtures. Lamp Compatibility Compatible with most one-, two-, three-, and four-lamp electronic standard and dimming AC ballasts. Operates one or two T5, T5HO, T8, T12, T8HO, T12HO, Circular T5/T9, U-bend T8/T12, 4-Pin CFL and long CFL lamps in emergency mode. Refer to the chart on the next page for a complete list of compatible lamps. Electrical Dual 120/277 voltage. Charge rate/power ON LED indicator light and push-totest switch for mandated code compliance testing. 6v long life, maintenance-free, rechargeable sealed NiCd battery. Internal solid-state transfer switch automatically connects the internal battery to fluorescent lamp(s) for minimum 90-minute emergency illumination. Fully automatic solid-state, two rate charger initiates battery charging to recharge a discharged battery in 24 hours. Time delay enhancement to overcome end-of-life circuitprotection. Mounting Suitable for installation inside, on top or in remote* of the fixture. Can be used in both switched and unswitched fixtures. UL Listed for factory or field installation. 13.4 9.4 2.4 1.5 Housing Durable painted steel construction in white finish. Compact design fits most fluorescent fixtures. * When battery packs are remote mounted, the remote distance cannot exceed ½ of the distance from ballast to lamp specified by the A.C. ballast manufacturer. The maximum allowable remote mounting distance is 50 feet. 33 Page 1 of 2 Rev: 3/21/2019

PAC0014 Fluorescent Emergency Ballast 1400 Lumens Electrical Information CATALOG NUMBERI NPUT WATTS (W)I NPUT AMPS (A) BPAC0014 AL1400TD 120V 277V 120V 277V 3.5 3.8 0.27 0.25 Lamp Compatibility Chart 34 Page 2 of 2 Rev: 3/21/2019

BAL650C-2 Fluorescent Emergency Ballast 650 Lumens Warranty & Listings Five year warranty against defects in material and workmanship (lamps excluded). Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA, Local and State Codes. UL Listed for damp locations (0 C 50 C). Suitable for use in sealed and gasketed fixtures. Lamp Compatibility Compatible with most one-, two-, three-, and four-lamp electronic standard and dimming AC ballasts. Operates one 13W-26W, 2-pin compact fluorescent lamps with GX23 and G24D bases. Refer to lamp compatibility chart for a complete list of lamps. Illumination Works with or without an AC ballast to convert new or existing fluorescent fixtures in to unobtrusive emergency lighting. Operates one lamp in the emergency mode for a minimum of 90-minutes. Provides a maximum initial lumen output of 650 lumens. Electrical Dual 120/277 voltage. Charge rate/power ON LED indicator light and push-totest switch for mandated code compliance testing. Long life, maintenance-free, rechargeable sealed NiCd battery. Internal solid-state transfer switch automatically connects the internal battery to fluorescent lamp(s) for minimum 90-minute emergency illumination. Fully automatic solid-state, two rate charger initiates battery charging to recharge a discharged battery in 24 hours. Time delay enhancement to overcome end-of-life circuitprotection. Mounting Suitable for installation inside, on top or in remote* of the fixture. Can be used in both switched and unswitched fixtures. UL Listed for factory or field installation. Housing Durable painted steel construction in white finish. Provided with 2 flex conduits on both ends. Compact design fits most fluorescent fixtures. * When battery packs are remote mounted, the remote distance cannot exceed ½ of the distance from ballast to lamp specified by the A.C. ballast manufacturer. The maximum allowable remote mounting distance is 50 feet. 2 NOTE: In 2-lamp operation, lumens are equally split between the two lamps. 35 Page 1 of 2 Rev: 10/27/2017

BAL650C-2 Fluorescent Emergency Ballast 650 Lumens Electrical Information BAL650C-2 CATALOG NUMBERI NPUT WATTS (W)I NPUT AMPS (A) 120V 277V 120V 277V 2.8 2.6 0.270 0.260 Lamp Compatibility Chart LAMP INITIAL LUMENS 1-LAMP 2-Pin PL CF 13W 380 2-Pin PL CF 18W 550 2-Pin PL CF 26W 650 36 Page 2 of 2 Rev: 10/27/2017

Notes 37

Notes 38

Notes 39

580 Eastview Drive Laurel, MS 39443 P.O. Box 1590 Laurel, MS 39441 800.956.3456 general 601.422.0033 601.422.1652 fax www.howard-lighting.com Revision Revision Date: Date: 10/3/2017 3/29/2019 40