MacroAir by Blue Giant AirVolution HVLS Fans

Similar documents
MacroAir AirElite HVLS Fans

MacroAir AirSpan HVLS Fans

MacroAir AirVolution HVLS Fans

SECTION HVAC Fans

Make Your Employees Your Biggest Fans

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening.

SECTION INCLINE WHEELCHAIR LIFTS. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

SECTION HVAC Fans

SECTION HVAC Fans

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SECTION XPRESS II INCLINED WHEELCHAIR PLATFORM LIFT. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

SECTION HVAC Fans

DETEX ARCHITECTURAL SPECIFICATIONS, June 2012 AO19 SERIES HEAVY DUTY LOW-ENERGY ELECTRIC SWING DOOR OPERATOR

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

INSTALLATION GUIDE DO NOT DISCARD THIS DOCUMENT: SAVE FOR FUTURE USE

92 RAILWAY ST. SEAFORTH, ONTARIO CANADA, N0K 1W0 TEL: ABSOLUTE AIR INSTALLATION MANUAL

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

Today's Topics & Sustainability Themes

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

BL41 Extra-long Barrier

Linear Heat Detection Engineering Specifications

SECTION AIR DOORS

SECTION AIR DUCT ACCESSORIES

Engineering Specifications

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

A. Section Masonry Assemblies: Anchor placement in masonry.

SECTION Overhead Coiling Doors

SECTION SPRINKLER SYSTEMS

BLG77 Rising Fenced Barrier

DIVISION FINNED WATER-TUBE BOILERS

SECTION (15767) - UNIT HEATERS

fans & heaters SIMPLE, ROBUST AND RELIABLE

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

CRESTRON: GREEN LIGHT NETWORK LIGHTING CONTROLS 1

THERMA FUSER SIDEWALL LINEAR VAV DIFFUSER

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

SECTION WET AUTOMATIC FIRE SPRINKLER SYSTEMS

B. Section Identification for Fire Suppression Piping and Equipment.

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

1.3 REFERENCES A. ANSI/NFPA 70 - National Electrical Code. B. ARI Commercial and Industrial Humidifiers.

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

DIVISION FINNED WATER-TUBE BOILERS

User s Manual and Operating Instructions

GORILLA HVLS Installation & Maintenance

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

HI Industrial Utility Heater HI Soleus Air International

PANEL FAN SERIES OPERATORS MANUAL (Galvanized and Polymer)

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

24 & 30 Quiet Design Oscillating Wall Mount Fan

Industrial Fans & Blowers

Guide Specifications for InRow Direct Expansion

SECTION ROTARY-SCREW WATER CHILLERS

Guide Specifications PART 1 GENERAL 1.01 SUMMARY

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

DUST COLLECTORS & DOWNDRAFT TABLES. A division of BLOWERS

RITE-HITE FANS HVLS FANS A REVOLUTION. IN COST, COMFORT AND DESIGN.

SPECIFICATIONS: FIREGUARD CROSS CORRIDOR CC

DIVISION FINNED WATER-TUBE BOILERS

ADVANCING HVLS technology through controls and energy efficiency

SECTION FAN COIL UNITS

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Aboveground Fuel Oil Lines

Installation Manual Universal Top-of-Pole Mount UNI-TP/02

Gas Station & C Store SECTION CWM Job No

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS

SECTION OVERHEAD COILING FIRE DOORS 641 SERIES OVERHEAD COILING COUNTER FIRE DOORS

City of Duluth Festival Center 04/25

ARCHITECTURAL SPECIFICATIONS

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES

STR-Series Indirect-Fired Air Turnover Units

AEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)

Installation Manual PLEASE READ AND SAVE THESE INSTRUCTIONS. Build September MacroAir Technologies 2005, Installation Manual, Page: 1

C. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009.

Architectural 3-Part Specifications

SECTION (15900) - INSTRUMENTATION AND CONTROL FOR HVAC

Chilled Water DOAS Fan Powered Terminal Units

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

Selecting the Correct Fan

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018

A. Codes and Standards that are Standard at the University:

What s Your Favorite Position?

CR1 Series Triton Corrosion Resistant Washdown Heaters

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Above Ground Greasy Waste Disposal Lines

Guide Specifications. HyperPod System PART 1 - GENERAL 1.01 SUMMARY

Irene-H READ AND SAVE THESE INSTRUCTIONS

ultra quiet fan USER MANUAL INSTALLATION OPERATION MAINTENANCE

Eliza Hugger 56 CEILING FAN

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

Transcription:

Manufacturer: MacroAir Technologies, Inc. 794 South Allen Street San Bernardino, CA 92408-2210 Macroairfans.com SECTION 15830 INDUSTRIAL/COMMERCIAL CEILING FANS PART 1 GENERAL MacroAir by Blue Giant AirVolution HVLS Fans 1.1 SUMMARY The AirVolution-D 550 High Volume, Low Speed (HVLS) fans from MacroAir by Blue Giant create large air movement and a comfortable environment while delivering substantial cost savings. They utilize a D- Drive next-generation DC motor that delivers 50% greater continuous horsepower than traditional HVLS fans and eliminates the need for a gearbox which reduces noise and moving parts. AirVolution-D 780 also has an on-board AirBrain processor that integrates into building operating systems via gateway and automatically adapts to input voltages. 1.2 SUBMITTALS A. Submit under provisions of Section 01300. B. Product Data: Manufacturer s data sheets on each product to be used shall include: 1. Preparation instructions and recommendations. 2. Storage and handling requirements and recommendations. 3. Power and mounting requirements. C. Application Drawings: Submit plan, section, elevation and isometric views as necessary to convey the information required to detail all installation conditions for each unit specified. 1.3 QUALITY ASSURANCE A. Manufacturer Qualifications: MacroAir by Blue Giant shall provide sole source for design, engineering, manufacturing and warranty claims handling. B. Installer Qualifications: Any and all work outside the scope of the installation guide shall be outsourced. Factory trained installers are recommended and available upon request.

1.4 REFERENCES A. Underwriters Laboratories (UL 507). 1.5 PROJECT CONDITIONS A. Maintain environmental conditions (temperature, humidity and ventilation) within limits recommended by manufacturer for optimal results. Do not install products in environmental conditions outside MacroAir by Blue Giant's absolute limits. 1.6 COORDINATION A. The fan shall be capable of receiving a stop command from the fire panel, an ASD (Aspirating Smoke Detection) device, or any number of smoke, flame or heat detectors. B. The fans shall be as follows: 1. The fan shall meet the air velocity requirements of FM Global s 2.0 data sheet for ESFR sprinklers. 2. If required by the local fire prevention authority or desired by the purchaser, the fan shall be wired into the building s fire suppression system so that the fan will automatically shut off within a maximum of 90 seconds after sprinklers are activated. To facilitate this automatic shut-down, the fan shall include a Variable Frequency Drive (VFD) within the control panel. The low voltage wire and relay needed to accomplish this must be supplied by the Fire Alarm installer. 3. Upon fire detection as described above, the fans shall coast to stop as required by NFPA guidelines. 1.7 WARRANTY A. MacroAir by Blue Giant shall repair or replace warranted defective parts as follows: 1. Lifetime warranty on airfoils and mounting. 2. Twelve-year service life prorated limited warranty on all other components, which include but are not limited to: a. Motor b. Integrated Drive c. Controller / Remote B. At project closeout, provide to Owner or Owner's Representative an executed copy of MacroAir by Blue Giant's standard limited warranty against manufacturing defect, outlining its terms, conditions and exclusions from coverage.

PART 2 PRODUCTS 2.1 APROVED MANUFACTURERS A. Acceptable Manufacturer: MacroAir by Blue Giant Technologies, Inc., which is located at: 794 South Allen Street, San Bernardino, CA 92408-2210 Toll Free Tel: 866-668-3247; Tel: 909-890-2270; Web: Macroairfans.com B. Substitutions: Not permitted. C. Requests for substitutions will be considered in accordance with provisions of Section 01600. 2.2 MACROAIR BY BLUE GIANT COMMERCIAL / INDUSTRIAL HVLS FANS A. Performance The fan shall be listed to applicable UL Standards and requirements by UL. Fan Model Dia. HP Hanging Weight RPM Power Usage (kw) Forward Displacement ** Reverse Displacement ** Industry Spacing *** Max. Affected Area**** Max dba **** MA08XL5506 MA10XL5506 MA12XL5506 MA14XL5506 MA16XL5506 MA18XL5506 8ft 10ft 12 ft 14 ft 16 ft 18 ft 120lbs / 54.5kgs 128lbs / 58.2kgs 140lbs / 63.5kgs 147lbs / 66.5kgs 151lbs / 68.5kgs 160lbs / 72.6kgs 220 0.73 170 0.85 137 0.92 110 0.89 90 1.07 74 0.9 53,000 CFM (1,490 CMM) 84,000 CFM (2,380 CMM) 106,000 CFM (3,010 CMM) 132,000 CFM (3,730 CMM) 158,000 CFM (4,490 CMM) 181,000 CFM (5,130 CMM) 29,000 CFM (820 CMM) 49,000 CFM (1,400 CMM) 76,000 CFM (2,140 CMM) 86,000 CFM (2,440 CMM) 114,000 CFM (3,240 CMM) 127,000 CFM (3,580 CMM) 60ft (18.3m) 65ft (19.8m) 70ft (21.3m) 80ft (24.4m) 90ft (27.4m) 95ft (29m) 4,000 ft² (372²) 6,600 ft² (613m²) 8,800 ft² (818m²) 11,000 ft² (1,022m²) 13,000 ft² (1,208m²) 15,000 ft² (1,394m²) * Data will be added when additional testing and/or information is ready ** Calculation based on AMCA 230-99 equation *** Delivers 2.8-4.2 ft/s [0.86-1.27 m/s] of average air speed in the occupied space. This relates to perceived cooling or set point change or 4.9-6.1 F [2.7-4.3 C]. Consult our online AirViz tool for more details. **** Delivers 2.7-3.8 ft/s [0.82-1.16 m/s] of average air speed in the occupied space. This relates to a perceived cooling or set point change of 4.8-5.8 F [2.6-3.2 C]. Consult our online AirViz tool for more details. ***** Sound testing taken with the sensor 5 ft above the ground and 20 ft from the center of the fan with the fan running full speed and mounted at 20 ft high. ****** Add 70 lbs / 31.8 Kg for a guard B. Airfoils The fan shall be equipped with six (6) NASA developed XL airfoils. The airfoils shall consist of anodized 6061 T4 precision extruded aluminum and be of the MacroAir by Blue Giant XL design, with fan diameters

ranging from 8 to 18 feet in two (2) foot increments and one (1) 24-foot diameter fan. The airfoils shall be connected to six (6) individual aluminum 6005 T6 struts by means of two (2) 5/16-24 x 2-inch grade 5 hex bolts, two (2) 5/16-inch flat washers and two (2) 5/16-inch nylon lock nuts per airfoil. 1. Number of Airfoils: 6. 2. Airfoil Material: 6061 T4 Extruded Aluminum. 3. Airfoil Finish: Anodized. 4. Optional Airfoil Finish: Custom powder coated colors per Drylac RAL color chart. C. Motor The fan shall be equipped with a Transverse Flux brushless DC motor designed for low speed high torque applications. The motor shall be driven sensorlessly to eliminate the possibility of sensor or encoder failure. 1. Motor Type: Sensor-less Transverse Flux brushless DC Motor 2. Continuous Torque: 52 lbf (70 Nm). 3. Pole Count: 96. 4. IP Rating: 66. 5. Insulation Class: K (200 C). 6. Motor Finish and Color: Black Electrophoretic Paint. 7. Motor Housing: AISI 383 (ADC12). 8. Studs: AISI 4137 Grade 9 (JIS SCM435). D. Integrated Drive 1. Electrical Requirements (Low Voltage) a) 104-277 VAC single (1) phase 50/60 Hz. 181-255 VAC three (3) phase 50/60 Hz. 2. Electrical Requirements (High Voltage) a) 241-294 VAC one (1) phase 50/60 Hz. 342-636 VAC three (3) phase 50/60Hz. 3. Environment a) Operation: -10ºC to 60ºC. b) Humidity: 0-95% non-condensing c) Cooling: Centrifugal cooling through blades 4. Operating Frequency: 20-50KHz 5. Firmware Updates: Via RJ45 (remote) connector 6. Lockable disconnect switch 7. Dynamic acceleration and deceleration 8. Modbus 485 (19.2 8-N-1) 9. BACnet and LonWorks options available

10. Network touch-screen options available with: a) Live energy consumption monitor b) Live fault code monitor c) Live fan speed monitor d) Impact and solvent-resistant e) IP65 rated E. Mounting The fan mounting system shall be equipped with hardware, no less than SAE grade 5 for safe installation. The fan shall be equipped with a stress reliving swivel (SRS) mount. The fan mount shall encompass multiple mounting options for I-beam, Purlin and Glulam applications (specified upon order). 1. Standard Mount: SRS I-beam clamp with 3.5 drop. 2. Optional Mounting Hardware: Glulam Mounting Brackets. 3. Mounting Drops: Extensions available in two (2) to ten (10) foot lengths in (1) foot increments (custom sizes available). 4. Mounting and Extension Material: Steel, Aluminum. 5. Mount Finish: Black Anodized. F. Hub / Motor Housing The fan shall be equipped with an aluminum motor housing with pressed in steel studs to securely accept six (6) removable, black anodized, 6005 T6 aluminum beam struts. The struts shall be designed with airfoil guides to ensure precision alignment and enable airfoils to be inverted for full CFM output in either reverse or forward operation. 1. Material: T6 Cast Aluminum. 2. Airfoil Strut Material: 6005 T6 Aluminum. 3. Airfoil Strut Finish: Black Anodized. 4. Hardware: Twelve (12) 5/16-24 x 1-3/4 inch Grade-8 pressed in studs. 5. Hardware: Twelve (12) 5/16-inch flat washers (SAE). 6. Hardware: Twelve (12) 5/16-inch nylon lock nuts G. Safety System The fan shall include one-piece airfoil retainer links to prevent airfoil separation from the motor housing and a 3/16 safety cable attached to the lowest point of the fan. Included in the safety system shall be fuses and a disconnect to prevent fire or misuse. Each fan shall be E-stop compatible for fire and building automated systems (BAS). 1. Safety Cable Material: 3/16 x 7 x 19 Braided Steel.

2. Safety Cable Finish: Galvanized. 3. Airfoil Retainer Link Material: 10 Gauge A36 Steel. 4. Airfoil Retainer Link Finish: Black Zinc. PART 3 EXECUTION 3.1 PREPARATION A. Check accuracy of dimensions indicated for openings to receive fans. B. Check location and availability of utility services to ensure proper voltage and installation preparation. C. Coordinate location and installation of the HVLS Fans. D. Ensure building structural members are sufficient to support the weight and operation of the fan. Consult professional engineer or registered architect as required. 3.2 INSTALLATION A. Install units per manufacturer's written instructions. B. Fan airfoil height to be a minimum of 10 feet from the floor in accordance with OSHA guidelines. C. All safety and support features must be installed. These include any guy wires and safety cables as well as airfoil retainer locking features. D. Adjust unit as required for proper operation in accordance with manufacturer s installation instructions. E. Securely anchor units. F. Ensure that operating parts turn freely prior to initial startup. G. Repair or replace damaged parts, dents, buckles, abrasions or other damage affecting appearance or serviceability, as acceptable to Architect. 3.3 PROTECTION A. Protect finished Work until date of Substantial Completion. B. Touch-up, repair or replace damaged products before Substantial Completion.

3.4 CLEANING A. Clean Work per Section 01 74 00. B. Clean and inspect fans per manufacturer's instructions. C. Remove temporary protective cover at date of Substantial Completion. END OF SECTION