UL Electrical Equipment for Measurement, Control, and Laboratory Use; Part 1: General Requirements, Second Edition

Similar documents
Certificate of Compliance

File E Project 05ME Issued: November 1, 2005 Revised: February 27, 2009 REPORT

IECEx Certificate of Conformity

Certificate of Compliance

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

Tank Gauging System Special Safety Instruction

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

ccsaus certificate: for GSI 127 Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title Page

Certificate of Compliance

SLATE. Sub-Base Module INSTALLATION INSTRUCTIONS R8001S9001

IECEx Certificate of Conformity

File E Project 97SC January 21, 1998 REPORT

standards: standards:

File S789 Project 04ME December 20, 2005 REPORT CONTROL UNIT (UOJZ) * * * * * * * * * * * * * * * * * * * * *

Field Certification Certificate of Compliance

IECEx Certificate of Conformity

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

Certificate of Compliance

D SYSTEM CONTROL DWG. APPROVED BY. OrCAD 6 ROSEMOUNT 2410

Model 144H. Product Data Sheet , Rev DB February Content

Quick Start Guide For the

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

Hazardous Area Zirconia Oxygen Systems

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas

User s Manual YTA610 and YTA710 NEPSI Certification

J-PRO TM Cable Support System

Rosemount 752 Fieldbus Remote Indicator

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

FLAME ITEM PART NO CLIENT REF. NO. DESCRIPTION DESIGNATION MANUFACTURER CLASS UL FILE NO.

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Certificate of Compliance

7800 SERIES 22-Terminal Universal Subbase

Annubar Flowmeter Series

Certificate of Compliance

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

Certificate of Compliance

Model 144H. Product Data Sheet , Rev DB February Content

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

SmartLine. RMA803 SmartLine Remote Fieldbus Indicator Specification 34-ST-03-90, December Technical Information.

VERSAFLOW VORTEX Supplementary instructions

UL TEST REPORT AND PROCEDURE

INSTRUCTION & SERVICE MANUAL

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System

SLATE. Burner Control Module INSTALLATION INSTRUCTIONS R8001B2001

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Installation Guide. EXGP Oxygen Analyzer System (ATEX) Interface Electronics Unit

Limit Switch Box YT-870/875 SERIES

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

Fixed Gas Detection System/Meridian CERTIFICATION

CONTROL BE MADE CHANGES MAY NOT. Page 1

FMP-ULS UNIVERSAL LIQUID SENSOR INSTALLATION GUIDE

ORDINANCE NO

SmartLine Pressure Transmitter ST 700 Basic Quick Start Installation Guide 34-ST-25-57, Revision 1, December 2016

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)

Quick Start Guide. XNX Universal Transmitter

Rosemount Pipe Clamp Sensor. Reference Manual , Rev BA February 2014

Installation Instructions for 116EXMLED Series AdaptaBeacon LED Lights for Use in Hazardous Locations. Description. Installation WARNING

Electrical Safety Requirements

Explosion Proof Push Button Momentary Switch - C1D1, C2D1 - Adjustable Timer - 10 sec-170 Minutes

UL TEST REPORT AND PROCEDURE

IECEx Certificate of Conformity

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

Rosemount 8800D Series Vortex Flowmeter. Quick Start Guide , Rev FE October 2018

North American Cable Glands

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100 5/9. Overview. Configuration

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

INSTRUCTION & SERVICE MANUAL

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

SET Installation and Operating Instructions. Level switch for one sensor

Explosion Protected Panelboards D2Z Series

Installation Instructions. Distinctive Electric Cooktop. Françis : voir page 11 Español: consulte la página Rev. A. Models DECT304, DECT365

INSTRUCTION MANUAL (ATEX / IECEx)

VQ500 Series Combustible Gas Detector Elements

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Installation Instructions

Notes: Warrick Series 67 Intrinsically Safe Multi-Function Control Installation and Operation Bulletin

Certificate of Compliance

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Rosemount 2051T In-Line Pressure Transmitter

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

Rosemount 8800D Series Vortex Flowmeter

Electronic 7 Installation Instructions

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Instructions. Explosion Proof Smoke Detector U Rev: 9/

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS

Certificate of Compliance

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Fire Alarm System Accessories

Rosemount 2051 Pressure Transmitter with 4-20 ma HART and 1-5 Vdc HART Low Power Protocol

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

WFDE Series Waterflow Detector

Transcription:

File E315190 Project 07CA39477 March 5, 2008 REPORT on PROCESS CONTROL EQUIPMENT FOR USE IN HAZARDOUS LOCATIONS Litre Meter Ltd. Buckinghamshire, England Copyright 2008 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the above named company to reproduce this Report provided it is in its entirety.

File E315190 Vol. 1 Sec. 1 Page 1 Issued: 2008-03-05 DESCRIPTION PRODUCT COVERED: USL Associated Apparatus Flow Meter for use in Class I, Division 1, Groups B, C, and D Hazardous Locations. Model FPODEXD-XJLGCHN4X provides intrinsically safe circuits for use in Class I, Division 1, Groups B, C, and D Hazardous Locations when installed in accordance with manufacturer s control drawing no. IS 6095. GENERAL: Model FPODEXD-XJLGCHN4X is a permanently mounted flow meter consisting of an explosion-proof enclosure containing a PCB with LCD mounted on an internal chassis, an IS barrier, and a communication interface connected to sensor model ULCOVERXA, followed by two single digit numbers. ENGINEERING CONSIDERATIONS (NOT FOR FIELD REPRESENTATIVE S USE): USL indicates investigation to the following United States Standards: UL 61010-1 Electrical Equipment for Measurement, Control, and Laboratory Use; Part 1: General Requirements, Second Edition UL 1203 Explosion-proof and Dust Ignition-proof Equipment for Use in Class I, II and III Hazardous (Classified) Locations, Fourth Edition UL 913, Intrinsically Safe Apparatus and Associated Apparatus for Use in Class I, II, and III Hazardous (Classified) Locations, Fifth Edition RATINGS: Power Input: 24 V dc, 100 ma max, +/-10%. Signal Input (Reed Switch) 24 V dc max, 10 ma max. Control Output: 24 V dc max, 100 ma. Signal (Communications Output): 32 V dc max, 4-20 ma HART or Fieldbus Output: Terminals 1 and 2 (from IS barrier): Voc = 10.5 V Isc = 14 ma Ca = 2.4 uf La = 165 mh Temperature Rating: -20ºC < Ta < +60ºC Temperature Code: T5MARKINGS: The device is provided with the markings as shown in ILL. 1 on a riveted, aluminum or stainless steel label.

File E315190 Vol. 1 Sec. 1 Page 2 Issued: 2008-03-05 CONTROL DRAWING: A copy of the control drawing no. IS 6095, shown in ILL. 2, is provided with each device. INSTALLATION INSTRUCTIONS: Installation Instructions are provided with each device and shall include the following: 1. The supply voltage shall not exceed 36 V dc, and The supply must be isolated from mains voltage by double/reinforced insulation 2. Intended use of the equipment, technical specifications including the supply voltage and power or current rating and a description of all input and output connections, instructions for use, name and address of manufacturer or supplier from whom technical assistance may be obtained 3. A statement of the range of environmental conditions for which the equipment is designed 4. Assembly, location and mounting requirements, instruction for protective earthing, field wiring size, type, tightening torque and recommended strip length 5. That a switch or circuit-breaker shall be included in the building installation, and a recommendation that the switch or circuit breaker used as the disconnect be located near the equipment 6. Instructions for interconnection to accessories and other equipment 7. If the display (explosion-proof enclosure) needs to be mounted away from the meter care should be taken when routing the armored cable. The cable should be fixed (clamped) within 20 in. (500 mm) of the glands (both meter and enclosure) to support and maintain the integrity of the seal. After installation these seals should be visually checked for damage. The cable length will not exceed 33 feet (10 m). CONSTRUCTION DETAILS: General The device is constructed in accordance with the following figures, illustrations and descriptive pages. Dimensions are approximate unless specifically indicated otherwise. Spacings Where affecting intrinsic safety, spacings have been evaluated and found to be in accordance with Table 8.1 in UL 913, Fifth Edition.

File E315190 Vol. 1 Sec. 1 Page 3 Issued: 2008-03-05 Clearance And Creepage Distances - Requirements for clearance and creepage distances were based on Pollution Degree 2. Clearances were evaluated and determined to comply with the requirements outlined in Table 5 of UL 61010-1. Creepage distances were evaluated and determined to comply with the requirements outlined in Table 7 or UL 61010-1. Internal Wiring Unless otherwise indicated, all internal wiring is R/C (AVLV2) rated 300 V, 100ºC minimum, and 24 AWG minimum with minimum insulation thickness of 0.25 mm. Printed Wiring board - Any R/C (ZPMV2) with flame rating of V-0, V-1, or V-2 and an operating temperature of 105 C, meets UL 746 direct support requirements. DOCUMENTATION: FIG. No. The device is constructed in accordance with the following drawings: ILL. No. Description Drawing No. Revision/Date 1 FPODEXD-XJLGCHN4X, External - - 2 Internal PCBs - - 3 Rear View, PCBs - - 4 IS Barrier, Front View - - 5 Metal Partition - - 1 Label LM-UL-TAG 1 2 Control Drawing IS 6095 2 3 OVERALL BOM FPODEXD-XJLGCHN4X BOM 2008-01-28 4 FLIN Board Schematic PB23012005 1.0 5 IS Screen Illustration - 1

File E315190 Vol. 1 Sec. 1 Page 4 Issued: 2008-03-05 Revised: 2008-10-15 MODEL FPODEXD-XJLGCHN4X (OVERALL ASSEMBLY) - FIG. 1 General Shown is the assembly of Model FPODEXD-XJLGCHN4X. Please note that the labels shown in the picture are not the final versions; see ILL. 1 for the final version. The complete assembly consists of an explosion-proof enclosure containing a 2-line LCD, temperature transmitter, F-Lin PCB, internal chassis, and IS barrier; along with a flow meter sensor connected via a cable, with a maximum length of 10 m. 1. Enclosure Listed (FTRV) enclosure manufactured by Adalet-PLM Fetzer Co., Cat. No. XJLGCHN4X. Overall dimensions of 6 5/32in.H by 7in.W by 7 in.d. The enclosure is provided with a 4 in. diameter window and two 3/4 in. NPT conduit entries. The enclosure is suitable for an ambient temperature of -20ºC to +60ºC. All unused conduit entries shall be filled with a UL Listed (EBNV) Plugs suitable for at least the same class and groups as indicated under the product covered and with at least five (5) full threads engaged. Threaded Joint Metal-to-metal threaded joint between the enclosure, Item 1, and Cable Sealing Fitting, Item 8, engages not less than five full NPT threads upon assembly. 2. 2 Line LCD manufactured by Ampire, Cat. No. AC-162BYILY. Dimensions 3 1/8 in. by 1 3/8 in.. 3. Foundation Fieldbus Puck manufactured by Wika, Cat. No. TE53.10.0XX where XX = NI or IS Dimensions 1 3/4 in. diameter by 3/4 in. deep. 4. F-LIN PCB manufactured by Litre Meter, Cat. No. 23012005. Dimensions 3 1/8 in. by 2 1/2 in. 5. Internal Chassis 6. IS Barrier UL Listed (QUZW), manufactured by Measurement Technology Ltd., Part No. 5012. See FIG. 4. 7. Partition Grounded, metal partition, separating IS from non-is wiring. See ILL. 5 and FIG. 5 for views. 8. Cable Sealing Fitting UL Listed (CYMX), manufactured by Hawke, Cat. No. 711 size A. Marked for an ambient range of 50 C to +60 C. For use only with MC cable employing continuous corrugated aluminum armor with HL surface marking and either ST574 or Hawkseal (Bicaseal) Activator sealing compounds. Cable OD range over jacket is 0.492-0.823. Fittings must be installed per the manufacturer s instructions. 9. Cable UL Listed (PJPP), manufactured by Okonite, Type MC-HL cable with continuous corrugated aluminum armor. Cable has an outer diameter of approximately 0.70in. Cable contains three (one cut back) Recognized (AVLV2) 14 gauge, Type XHHW-2 copper insulated conductors. Rated 600 V. 10. Flow Meter Sensor Housing may vary, only contains reed switch. Marked with the following nomenclature: ULCOVERXAYY, where YY may be any two digit number, varying with the housing.