GST-FT40N Fire Telephone Panel Installation and Operation Manual

Similar documents
Installation and Operation Manual

C Installation and Operation Manual

I-9105R Intelligent Reflective Beam Detector Installation and Operation Manual. The Intelligent Solution CONTENTS

CONTENTS. GstDef2.1 Defining Tool User s Manual

CONTENTS Installation Precautions... 1 Chapter 1 Product Introduction... 2 Chapter 2 Technical Specifications... 3

C-9105R Conventional Reflective Beam Detector Installation and Operation Manual. (Issue 2.01, February 2006)

I-9105R Intelligent Reflective Beam Detector Installation and Operation Manual. (Issue 2.03 February 2006)

GST Headquarters. GST Production Base

CONTENTS. GST102A/104A/108A/116A Conventional Fire Alarm Control Panel Installation and Operation Manual

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

INSTALLATION INSTRUCTIONS

Installation and user manual for the BiWire / Conventional Repeater Panel

RC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005)

Norstar. Doorphone User Guide

Conventional Fire Alarm System 2014 V1.2

TrueCom. Building Communications Systems 5115-Series , Area of Rescue Communications System. Description

CONTENTS. I Description II Specification III Structure IV Mounting and Wiring V Application VI Troubleshooting...

FX FIRE DETECTION SYSTEM

Control Panel User Guide

Alarm Tone Generator Model AG17

EX-TECH SIGNALLING SAS SD100-1 WEATHERPROOF SOUNDER/HORN TECHNICAL MANUAL

General Routing Interface

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

Basic Installation Manual

TPMS1309P05. User Manual

Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System

DESCRIPTION INSTALLATION

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

MLHG6-AU. Iso-Gard Line Isolation Monitor (LIM) Setup Guide ! WARNING. Components

rvm4c Installation Guide Remote Video Module

Intelligent Security & Fire Ltd

TECHNICAL MANUAL EDITION 1.0 VANDAL RESISTANT AUDIO AND VIDEO DOOR ENTRY SYSTEMS

Pre-Installation Requirements:

Fire Control Panel. Installation & Programming Manual TABLE OF CONTENTS

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

USER S MANUAL. Profile. MOBILE CALL GSM Alarm System

Premier Hazard STC Instructions

The following equipment is included in your Tunstall Home box t :

Signature Series Auto-Sync Output Module (CC1S)

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

Security System. User Guide for the LED Command Center

User Guide English. Manual Version 1.0

AVCOM System Installation Instructions

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

GST5000. Installation and Operation Manual

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

BENTEL SECURITY srl reserves the right to modify the technical specifications of this product without prior notice.

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

System. For a better understanding of this product, please read this user manual thoroughly before using it.

U ser's Guide PC6010

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

SIGA-CC1 Single Input Signal Module Installation Sheet

Print Specification. Publication. Instructions. Specific requirements. General requirements

ISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

ANEP S-BOX EMERGENCY TELEPHONE FOR ELEVATORS.

KSUF CONTROL AND MONITORING UNIT. Description. Installation Designed for wall installation.

Quick Alert Remote (QA216R)

Installation Manual Premier 412/816/832. Issue 10

C-Bus Four Channel General Input Unit Installation Instructions

GSM Smart Home Alarm Apparatus. [99+4 defense zones] Instruction for Use

USER MANUAL FOR OPERATING SYSTEM

SECURIT 703 USER MANUAL

5, SE GÅNGHESTER,

GT-1D. Residential/Tenant Station OPERATION MANUAL

SCAN200E USER S MANUAL

NESS 5000 SERIES DIALLER

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

Fiber Optical Multiplexer

M2500 Engine Controller Installation Manual

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Universal fault annunciator for panel mounting

XP95 Sounder VAD Base

Memcom Emergency Telephone

Destiny Destiny Owners Manual

SPECTRA 1728, 1738 CHEAT SHEET:

TECHNICAL. Voice Alarm Dialing or Store Caster Announcements from up to Eight Inputs. K-2000-DVA Multi-Input Voice Dialer/Announcer

ECC-50/100C. Emergency Command Center

SECURIT 700L USER MANUAL

CEM-24 Series. Owner's Manual - Installation and Operating Instructions

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

User Manual (LS-GSM-006)

DYGIZONE GJD910 Lighting Controller & Enunciator

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

Intruder alarm system Operating Instructions

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Operating instructions 2-channel code lock. Item No

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

Chore-Tronics Load Cell Indicator

SecurityLink Plus TM. User s Guide. K /04 Rev. A

OPERATING INSTRUCTIONS VOICE EVACUATION SYSTEM FS-7000 SERIES

Accenta/Optima. User Guide. UK Security Panels. Servicing Organisation (Installer) name: Telephone Number: Date of Installation: Account Number:

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

SMOKE User Manual. NE v2.0

1. User features of the GSM dialer

DigiAir QUICK GUIDE & INSTRUCTION MANUAL

SECURIT 700L PLUS ENGINEERING MANUAL

Fire Control/Communicator

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Security Control Panel with Communicator Interface

WARNING FIRE DOOR CLOSING

Transcription:

Installation and Operation Manual

CONTENTS 1 GENERAL...1 2 TECHNICAL SPECIFICATIONS...1 3 PANEL INSTRUCTION...2 3.1 APPEARANCE AND STRUCTURE...2 3.2 THE FRONT SURFACE...2 3.3 THE KEYS...3 3.4 INDICATORS...3 3.5 DIGITRON DISPLAY...4 4 FIRE TELEPHONE SYSTEM DESIGN...4 4.1 STAND ALONE FIRE TELEPHONE SYSTEM...4 4.2 NETWORKED FIRE TELEPHONE SYSTEM...4 5 MOUNTING & COMMISSION...5 5.1 INITIAL CHECK...5 5.2 WIRING REQUIREMENT...5 5.3 INSTALLING DIMENSION...5 5.4 TERMINALS ON THE PANEL...6 5.5 SYSTEM COMMISSIONING...7 Set panel address...7 Register the Network Panels...7 Test Functions...7 6 USER GUIDE...7 6.1 PANEL CALL HANDSET...7 6.2 HANDSET CALL PANEL...8 6.3 CALL PANELS IN NETWORK...8 6.4 PANEL TO PANEL CALL...8 6.5 INQUIRE ABOUT CONVERSATION RECORD...8 7 TROUBLESHOOTING...8 7.1 ZONE FAULT...8 7.2 NETWORK FAULT...9 Page II

1 General fire telephone panel is specialized for emergency communication, builds up convenient and prompt 2-way communication in case of fire and other abnormal conditions. It is an indispensable device in fire protection system. The panel has features as below: Standard 4U structure, rack mount installation 24VDC power supply Receiving and calling out with fire telephone handsets Networkable fire telephone panels achieve internal communication Call from handset will be transferred to networked fire telephone panels automatically after not answered by the dedicated panel The handset zones are fully monitored for fault of short circuit and open circuit. Panel will show the fault by sound and indicator. Failure of one zone will not effect on other zones The network communication is monitored. When sub-panel fails to communicate with the main panel, the main panel will get the failure message and broadcast to other networked sub-panels, both main panel and sub-panels will indicate by sound and light indication. When the fault happens on main panel, all sub-panels will show the fault message, and meanwhile the network call will be inhibited. Record: The conversation between fire telephone panel and Handset or other fire telephone panel can be recorded up to 15 minutes. The new content will cover the old one when the storage is full. 2 Technical Specifications Operation Voltage 24VDC±10% Standby Current 0.3A Maximum Current 1.2A Frequency Range 300~3400Hz Crosstalk <-60dB Transmission Loss <5dB Environment Temperature -5~40 C Relative Humidity 45%~95% Dimension 482.5mm 177mm 225mm Gross Weight 5.3 kg Network Capacity 8 panels Panel Capacity 40 zones Zone Capacity 5 handsets End of Line Resistor 10kΩ±0.5KΩ Page 1

Notes: words using within this file (Panel): Installed in fire control center, the device can communicate with field terminals, such as. Handset: Field device, which can communicate with fire control center, such as P-9911(F) and P-9911(M). Main panel: The No.1 panel in the fire telephone panel network Sub-panel: Panels other than No.1 in the fire telephone panel network 3 Panel Instruction 3.1 Appearance and Structure fire telephone panel is rack mount type, the appearance is shown in Fig.3-1 FIRE TELEPHONE PANEL Fig.3-1 3.2 The front surface Page 2

Fig. 3-2 3.3 The Keys Key Mute Network Call Zone 1-40 Description Stop the alarm sound caused by fault Answer or start network call Answer, call or hang up the corresponding zone. 3.4 Indicators Indicator Call LED, 1-40 Ring In LED Fault LED, 1-40 Network Fault LED Power LED Mute Description Red, indicating the conversation status between panel and corresponding zone. Flashing: in the process of connection On: under conversation Off: no conversation Red, fast flash when there is call in from network or zone Yellow, lit on when corresponding zone in Fault condition Yellow, lit on when there is network fault Green, lit based on usual power supply Red, lit when panel sound alarm silenced Page 3

3.5 Digitron Display State Example Description Network Free On the main panel, the first digit indicates the quantity of panels in the network, the last digit indicates its network address On sub-panel, only the last digit will show its network address Network Call The first digit indicates the address of the calling panel. The C at the last digit means Calling. Network Conversation The sample at the left shows the conversation state between No.1 panel and No.2 panel. The others will show BUSY The first digit indicates the address Network of failed panel. The E means Error. Failure 4 Fire Telephone System Design 4.1 Stand Alone Fire Telephone System Fig. 4-1 shows a standalone fire telephone system. The panel can connect maximum 40 zones with each zone maximum 5 handsets. Fig. 4-1 4.2 Networked Fire Telephone System The system consists of a group of panels as many as 8. The panel with the address 1 is the main panel and the rests are sub-panels. Please refer to commission section for setting up addresses. Page 4

Fig. 4-2 5 Mounting & Commission 5.1 Initial Check Check the appearance of the panel after open the box. Then power on and check working state. 5.2 Wiring Requirement Cross-section area of the power cable not less than 1.5mm 2 Twisted-pair cable connecting panel and handset with SA not less than 1.0 mm 2 Twisted-pair cable for the network with SA not less than 1.0 mm 2 The cable selection must comply with local code Note: the impedance of single line not more than 20Ω 5.3 Installing dimension Installing dimension: 482.5mm*177mm*225mm Page 5

5.4 Terminals on the panel Fig. 5-1 Power (+24, GND): 24VDC power in, polarized E: GND Network (+, -): Network, polarized Audio Output: Audio signal output Zn+, Zn-: Zone Terminals, connecting with handsets (a 10KΩ±0.5KΩ resistor is required to the last point of each zone). Page 6

5.5 System Commissioning Please Make Sure the Correct Wiring before Commissioning. Set panel address For standalone fire telephone system, the address can be assigned 1 or keep the default setting. There must be one panel assigned 1 in the network fire telephone system and register other panels. Addressing step: Press a key between 1-8 key of front surface, then power on, press the key over 2s, the number will become the network address of the panel. The address will not be lost when the panel is switched off. The address will not be changed unless 1-8 key is pressed when the panel is powered on. Note: The panel addresses can not be repeated in same network. Register the Network Panels After assigning the addresses, power on the sub-panels first. Then power on the main panel. The main panel will register all networked sub-panels automatically. Subsequently, the first digit of the digitron will show the number of networked panels (including the main panel). Check whether all panels have been registered according to the shown number. If no consistency, check the wiring and repeat the above-mentioned process. The registration information is saved in non-volatile memory, will not loss on power off. The registration should be carried out again in case adding or removing network panels. Not necessary for registration on sub-panel. Test Functions Test the other functions according to Operation Manual after commissioning. 6 User Guide 6.1 Panel Call Handset Press a key of zone 1 to 40, the corresponded zone will be called with Call LED slow-flashing. The conversation will be set when handset picked-up, with Call LED lit showing status. During the conversation, press the key again will stop the call. The call LED won t go out until hanging up the handset. If the handset is hung up first, the conversation will stop immediately with Call goes out. Page 7

The panel can make call to handsets in other zones when a conversation is underway. 6.2 Handset Call Panel Once the handset is picked up without being called, the call will go to the panel. The panel will ring with Call and Ring In LED fast-flashing. Press the relative key and enter into conversation with Call being on, Ring In goes out. Meanwhile, if there are other zones calling panel, Ring In will keep fast-flashing. Hang-up the handset or press the relative key on the panel will stop the conversation. 6.3 Call Panels in Network If the handset call is not answered by the panel within 12s, and the network is available, the call will be transferred to other networked panels. Press Network Call and start the conversation. Stop the conversation by handset hanging up or Network Call repressed. 6.4 Panel to Panel Call When network is available, press Network Call will send the call to entire network with the LED indicator fast-flashing. Meanwhile, the digitron on other networked panels will show by flashing X C (X- The calling panel), the Ring In and Network Call LED will fast flash with ringing sound. Press Network Call button and then start the conversation. The digitron of the panels not attending conversation will show BUSY and the ring tone stops. Panel in conversation will show the address of the other one. Either part can stop the conversation by pressing Network Call. 6.5 Inquire about conversation record Press PLAY key of the electric recorder, then the record will be played. Press FORWARD and REWIND to switch the content rapidly and press to stop. Electric recorder will start or stop recording automatically along with the conversation, The new content will cover the old one when the storage is full. 7 Troubleshooting 7.1 Zone Fault The zone fault shows an open or short circuit between panel and handsets, or the End of Line Resistor not connected. Check the cable by multi-meter, whether the resistance is roughly 10kΩ. Page 8

7.2 Network Fault The panel shows network fault when there is any of the panels powered off or network cable fault. Check the malfunction panel and wiring. Page 9

GST China Gulf Security Technology Co., Ltd. No. 80, Changjiang East Road, QETDZ, Qinhuangdao, Hebei, P. R. China 066004 Tel: +86 (0) 335 8502528 Fax: +86 (0) 335 8508942 Email: sales@gst.com.cn www.gst.com.cn GST UK Global System Technology PLC Lion Court, Staunton Harold Hall, Melbourne Road, Ashby de la Zouch, Leicestershire, England LE65 1RT Tel: +44 1283 225 478 Fax: +44 1283 220 690 Email: info@gst.uk.com www.gst.uk.com GST Dubai Global System Technology PLC PO Box 17998 Unit ZA04 JEBEL ALI Free Zone, Dubai, UAE Tel: +971 (0) 4 8833050 Fax: +971 (0) 4 8833053 Email: info@gst.uk.com www.gst.uk.com