Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

Similar documents
Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

Drawing Submittal Package

Drawing Submittal Package

Technical Data Submittal Document

Technical Data Submittal Documents

LMR Electric Fire Pump Controllers Features

Model GPP Full Service Reduced Voltage Part Winding Electric Fire Pump Controller

LMR Electric Fire Pump Controllers Features

FDF Foam Pump Controllers Features

Model GPS Full Service Reduced Voltage Soft Start Soft Stop Electric Fire Pump Controller

Model GPA Full Service Full Voltage Across the Line Start Electric Fire Pump Controller

Model GPW Full Service Reduced Voltage Wye-delta Closed Electric Fire Pump Controller

Soft Start Series MP700 Solid State, Reduced Voltage

Across-the-Line SERIES MP300 Combined Manual and Automatic

Model GPS + GPU Full Service Reduced Voltage Soft Start Soft Stop Electric Fire Pump Controller with Automatic Power Transfer Switch

Variable Frequency Drive SERIES MP800 VFD

Transfer Switch Features

Model GPS + GPU Full Service Reduced Voltage Soft Start Soft Stop Electric Fire Pump Controller with Automatic Power Transfer Switch

Model GPW + GPU Full Service Reduced Voltage Wye-delta Closed Electric Fire Pump Controller with Automatic Power Transfer Switch

Model GPY + GPU Full Service Reduced Voltage Wye-delta Open Electric Fire Pump Controller with Automatic Power Transfer Switch

Transfer Switch Features

FT60 Reduced Voltage - Autotransformer

FD30 Full Voltage - Across the Line July 2011

Customer Connection Terminals Connection terminals for external customer connections, are located at the top of the Power I/O board.

Fire Pump Controllers Medium Voltage Controllers

FDJ SERIES Jockey Pump Controllers Features

FT40 Reduced Voltage - Part Winding. Electrically and Mechanically

DIESEL Engine Fire Pump Controllers Features. FD120 Diesel Engine Controllers

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

FT20 Full Voltage - Limited Service. Electrically and Mechanically

WITH POWER TRANSFER SWITCH STANDARD SUBMITTAL PACKAGE

Fire Pump Controllers Foam (Additive) Controllers

DIESEL Engine Fire Pump Controllers Features

Technical Data Submittal Documents

DIESEL Engine Fire Pump Controllers Features

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

SECTION FIRE PUMPS 1.00 PART 1 & GENERAL Description of Work. A. Provide pumps for fire suppression Section Includes

SECTION Fire Pumps

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Options for Diesel Fire Pump Controllers

FTA550 JOCKEY PUMP CONTROLLERS

Remote Alarm Panels Features

FTA550F JOCKEY PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

P.C. Simonton & Associates, Inc. Consulting Engineers. Paul C. Simonton

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION 4000 LIFT STATIONS

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Commercial and Light Industrial Fire Alarm Control Panel

EATON LMR Plus Electric Fire Pump Controllers

Microprocessor Based Wye-Delta Reduced Current Type Starting

Specification/ Data Sheet

Fire Pump Controller. For Electric Motor Driven Fire Pumps. Wye Delta Reduced Current Types

PILOT SERIES MPT700TS

Model GPD Diesel Engine Driven Fire Pump Controller

SECTION AUTOMATIC TRANSFER SWITCHES

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

Packaged Instantaneous Circulation Heater Full KW Selection In All Voltages, Single or Three Phase

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

VACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

University of Houston Master Construction Specifications Insert Project Name SECTION FIRE PROTECTION PUMPS PART 1 - GENERAL

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

SECTION ROTARY-SCREW WATER CHILLERS

PART GENERAL 1.01 SECTION INCLUDES

Moulded case circuit brakers

Conventional Releasing Control Panel

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

MANUAL FOR MODEL MP600 HIGH VOLTAGE ELECTRIC MOTOR DRIVEN FIRE PUMP CONTROLLERS

R E C T I F I E R I N V E R T E R C O N V E R T E R SB7

C1N Series - Light Industrial Heaters Tankless Water Heating Solutions

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G

I P. Tough Starters for Tough Environments. Explosion Proof Starter. Ready to Install, Completely Wired and Assembled

TS Series. Technical Instructions. Document No. TS-4000 June 25, TS-CE Combustion Enclosures with LMV5. Description

Discontinued. SN Series - Safety Shower Heaters Tankless Water Heating Solutions. Standard Equipment. Construction. Code Compliance and Certifications

Fluid Cooler Fan and Pump control panel

Guide Specification Model CTG Automatic Transfer Switch

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

Heating Cable. Description

Product Specifications 480 VAC, 175A Main Power Distribution Panel

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

FTA200-A REMOTE ALARM PANEL

SEQUENCE OF OPERATIONS

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

CTO BOOSTER SPECIFICATION

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018

SN Series - Safety Shower Heaters Tankless Water Heating Solutions

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH CHEETAH Xi 50 CONTROL PANEL

PUMP CONTROL CENTER (PCC)

Multi-Institutional Academic Health Science & Research Center Evansville, IN

SECTION FIRE PUMP AND CONTROLS

08/17/2011 Rev. 4 PULL STATION EXHAUST HOOD 10 TO 20 FEET FROM HOOD LOCATE ONE NEAR EVERY POINT OF EGRESS FROM HOOD

CADDY CORPORATION. Utility Distribution Systems

BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES. READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION.

600-10,000 scfm AES Series. AES Series Energy Saving. Refrigerated Air Dryer ,000 scfm. Front Page

INSTALLATION AND MAINTENANCE MANUAL FOR ELECTRIC FIRE PUMP CONTROLLERS MODEL GPX

Transcription:

Project: Customer: Engineer: Pump Manufacturer: Submittal Document Model VPS Pressure Limiting (VFD) with Soft Start Bypass Contents: Data Sheets Dimensional Data Wiring Schematics Field Connections Note: The drawings included in this package are for controllers covered under our standard offering. Actual AS BUILT drawings may differ from what is shown in this package.

From normal incoming power through Disconnecting Means (IS/CB)* CR6 CR8 CR7 1R 4R 1R 4R CR6 CR7 CR8 2R 3R FU1 SSS1 2R 3R LR1 VFD1 POWER MODULE Standard, Listings and Certifications Built to NFPA 20 (latest edition) Underwriters Laboratory (UL) UL218 - Fire Pump Controllers New York City Accepted for use in the City of New York by the Department of Buildings *Please see Disconnecting Means details on page 3. Enclosure Protection Rating Standard: NEMA 2 (IP31) Optional NEMA 12 NEMA 3 NEMA 3R IP54 Accessories Bottom entry gland plate Lifting lugs Keylock handle Paint Specifications Red RAL3002 Powder coating Glossy textured finish Shortcircuit Withstand Rating Standard 100kA Optional 150kA 200V to 208V 220V to 240V 380V to 416V 50 Hz / 440V to 480V 600V Normal Power Normal Power Normal Power Normal Power Normal Power 5-150 5-200 5-300 5-400 n/a HP Standard 50kA Optional 100kA n/a n/a n/a n/a 5-500 2

Ambient Temperature Rating Operating Modes Surge Suppression Disconnecting Means Service Entrance Rating Standard: 5 C to 40 C / 41 F to 104 F The controller shall have the capability of running the pump motor in the following three (3) modes via a speed mode selector switch: Variable mode: Upon an automatic or manual start, the controller shall start the pump through the variable frequency drive (VFD) and instantly regulate the motor speed in reference to the discharge pressure Preset mode: Upon an automatic or manual start, the controller shall start the pump through the variable frequency drive (VFD) and run the pump motor at a pre-determined speed. This pre-determined speed shall be adjustable on the variable frequency drive (VFD) itself Bypass mode: Upon an automatic or manual start, the controller shall start the pump through the reduced voltage soft start bypass circuit. Surge arrestor rated to suppress surges above line voltage Isolating switch and circuit breaker assembly: - Door interlocked in the ON position - Isolating switch rated not less than 115% of motor full load current - Circuit breaker continuous rating not less than 115% of motor full load current - Overcurrent sensing non-thermal type, magnetic only - Instantaneous trip setting of not more than 20 times the motor full load current Common flange mounted operating handle Suitable as service entrance equipment Emergency Start Handle Flange mounted Pull and latch activation Integrated limit switch Across the line start (direct on line) Locked Rotor Protector Operate shunt trip to open circuit breaker Factory set at 600% of motor full load current Trip between 8 and 20 seconds Electrical Readings Voltage phase to phase (normal power) Amperage of each phase when motor is running Pressure Readings Pressure and Event recorder Pressure Sensing Continuous system pressure display Cut-in and Cut-out pressure settings Pressure readings with date stamp Event recording with date stamp The recorder will register and keep in memory pressure fluctuations over time that have occurred over the previous seven (7) days and events, alarms, general system information that have occurred over the previous fifteen (15) Information is retrievable through DB9 communication port accessible without having to open the controller door. Pressure transducers (2) for reading of discharge pressure Pressure sensing line connection 1/2 Female NPT Rated for 0-600PSI working pressure Externally mounted with protective cover 3

Audible Alarm Visual Indications Visual & Audible Alarms Alarm buzzer Normal power available Alternate power available Normal position Alternate position Visual only Power loss Motor run Phase reversal Phase unbalance Visual and Audible Overcurrent Undercurrent Fail to start Individual phase-to-phase voltage indication + Hz frequency (normal power) Individual phase current indication Pressure indication Elapsed run time Phase loss L1 Phase loss L2 Phase loss L3 Low System pressure Presure transducer problem By-pass mode VFD Failure Undervoltage Overvoltage** Locked rotor System trouble Remote Alarm Contacts Audible only Fault SSS (soft-start) DPDT-8A-250V.AC Power available Phase loss Power loss Overvoltage Undervoltage Phase unbalance Phase reversal Bypass mode VFD Failure Motor run Common motor trouble Overcurrent Undercurrent Fail to start Pressure transducer problem Operator Interface Operation Micro-processor based Accessible without opening main door Voltage and current indication Pressure settings and system pressure indication 15 day pressure and 15 day event Automatic Start Manual Start Stopping Timers Actuation Mode Start on pressure drop Start pushbutton Remote start from manual device Manual with Stop pushbutton Automatic after expiration of minimum run timer *** Field Adjustable & Visual Countdown Visual Indication Minimum run timer ***(off delay) Sequential start timer (on delay) Periodic test timer Pressure Automatic Non-automatic ***Can only be used if approved by the AHJ 4

A06B A07B A9 A10 A11 B11 B11B B19A B19B C1 C4 C7 C10 C14 C15 C18 Lockout Circuit from other VPx Interlock Circuit from other VPx Low zone pump control function Medium zone pump control function High zone pump control function Built in alarm panel (120V.AC supervisory power) providing indication for: Audible alarm & silence pushbutton for motor run, phase reversal, loss of phase. Pilot lights for loss of phase & supervisory power available Built in alarm panel same as B11 but 220-240VAC supervisory power High motor temperature c/w thermoster relay and alarm contacts (DPDT) High motor temperature c/w PT100 relay and alarm contacts (DPDT) Extra motor run alarm contact (DPDT) Periodic test alarm contact (DPDT) Low pump room temperature alarm contact (DPDT) Low water reservoir level alarm contact (DPDT) Pump on demand / automatic start alarm contact (DPDT) Pump fail to start alarm contact (DPDT) High water reservoir level c/w visual indication and alarm contact (DPDT) Cx D1 D1A D13 D14 D14A D14B D15 D24 D26 D26A D27 D27A D28 D37 Additional visual and alarm contact (Specify function) (DPDT) Low suction pressure transducer for fresh water rated at 0-300PSI with visual indication and alarm contact Low suction pressure transducer for sea water rated at 0-300PSI with visual indication and alarm contact High withstand rating for (normal power section) 208V to 480V = 150kA 600V = 100kA Anti-condensation heater & thermostat Anti-condensation heater & humidistat Anti-condensation heater & thermostat & humidistat Tropicalization Audible Alarm Modbus with RTU frame format and RS485 connection Modbus TCP / IP provision Motor heater connection (external single phase power source and heater on/off contact) Motor heater connection (internal single phase power source and heater on/off contact) Customized drawing set Window kit for operator interface C19 Emergency start alarm contact (DPDT) C21 Deluge valve start alarm contact (DPDT) C22 Remote automatic start alarm contact (DPDT) C23 Remote manual start alarm contact (DPDT) C24 High pump room temperature alarm contact (DPDT) Note: Options chosen from this page are not electrically represented on the wiring schematics in this submittal package. 5

Operator Interface Normal Alternate Current / Time Pressure L1-L2 L2-L3 L3-L1 V. / Hz V. / Hz A. / Hr Normal Power Available Normal Position Phase Reversal Low System Pressure Altern. Power Available Alternate Position Isolating Switch in Off Position System Trouble Cut-out Cut-in Reset Test Print Paper Feed Trouble Legend : P : Pump Starting Failure O : Overcurrent Problem U : Undercurrent Problem T : Pressure Transducer Problem 6