Package Hygienic Air Handling Units. PHK Series

Similar documents
Air Cooled Chillers & Heat Pumps WinPACK HE-A

Air Cooled Chillers & Heat Pumps FullPower HE-A

Enjoy the Delighting Comfort Brought by High Air Quality

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

IT COOLING CLOSE CONTROL AIR CONDITIONERS PRECISION AIR CONDITIONERS WITH INVERTER TECHNOLOGY FOR STABLE ROOM CONDITIONS

INDEX. Epilogue / 52 İÇİNDEKİLER

Heat and energy recovery ventilators

INDEX. Epilogue / 56 İÇİNDEKİLER

nemo 5,4 30,5 kw 6,4 37,4 kw R410A PLATE water cooled chillers / heat pumps and motoevaporating units COOLING HEATING

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

DVU-HP. Integrated Reversible Heat Pump System

TEXTILE AIR ENGINEERING EASY INSTALLATION HIGH PERFORMANCE ENERGY EFFICIENCY

Modular Air Cooled Scroll Chillers


Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

50VZ (40PZ/38VZ) Vertical Air-Cooled Split-System Cooling Units. Nominal cooling capacity kw

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Auxiliary Equipment and Accessories

New CGAF Air Cooled Scroll Chiller. New Air-Cooled Scroll Chiller CGAF

Roof top SPACE RPC 450Z R407C M011

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

next DX.U.S* 052.Z2.H6.DC

Launching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

CONTACT US. For more information,

CONTENTS DE-HUMIDIFICATION IN INDOOR SWIMMING POOLS 2 DESIGN PROPERTIES OF THE INDOOR POOL DE-HUMIDIFYING UNIT 4 FRAME STRUCTURE 6 PANEL STRUCTURE 6

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB

ADD-ON AIR CONDITIONING CHANGING THE GAME FOR COMFORT AND PERFORMANCE

recooler HP EQKR HEAT PUMP

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

condenciat cl Condensing units Outdoor condensing unit Variable speed propeller fan Use Description for direct expansion applications

GEA Ultra-Denco. GEA Heat Exchangers / HVAC Systems. Close Climate Control for IT Environments. Reliability with low power consumpstion

Next MTR kw. technicalcatalogue. Air conditioners for Metrology Labs with upflow air delivery T_NXTMTR_0511_GB

Roof top SPACE RPC 315Z R407C MA00

AHU Plus. DX Air Handling Units

ACMVTECH HIGH EFFICIENCY UNITARY AHU

Compact Design For Light Commercial Buildings. Benefit Points SMALL OFFICES HOTELS NEW SHOPS, RESTAURANTS. 1. Compact & Quiet design

OT 300/430/570 STEAM STERILIZERS

FOUR-HOME-CEILING Ceiling Type Residential Heat Recovery Unit. is a registered trademark of Doğu İklimlendirme A.Ş.

VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN

SysAer. An efficient rooftop unit. Chillers & Heat Pumps Water terminals Rooftops Close control Water source heat pumps Direct expansion.

Adsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system

Heat Recovery Units. Heat Recovery Units

york airside products Tailored air conditioning solutions Introducing the YORK YPRE range of custom air-to-air packaged roof top units

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

CHAPTER 6 CONDENSING UNITS

Mundaria. The new series of air-conditioning units. for operating theatres

Precision air handling cabinets Ciatronic MICRO/EXPAIR

Adconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

HANDBOOK REGULATOR VALVES. Ed REGULATOR VALVES RP-ED 01/ ENG 1

Integrated VarIable refrigerant flow ahu/pau (r410a)

Precision air conditioners with inverter technology for stable room conditions

Aquaflair TRAC-TRAF-TRAH

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

Compact SLIM. Air cooler GASC. Air coolers in a flat design with forced draught fans Optimal for commercial cooling. HFCs, CO 2 0.

AHRI Certification Program Scopes - COOLING

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

Air handling units. Technical Catalogue

MRVIII-C MRVIII-C. 4 way air return heat exchanger design. Two stages heat exchanger design. Double EEV design. Special Heat Exchanger Design

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

Technical Data OPA RKTBG-P. Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

HVS, Hydro Variable System

H Series Surgical room air conditioners. with direct expansion coil: OHA series with chilled water coil: OHU series

AIR TO WATER UNITS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS (PLUG FAN), FOR INDOOR INSTALLATION kw

Smart air handling unit for swimming pools IN CONFORMITY WITH THE REQUIREMENTS OF

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

AZURE COUNTER FLOW HEAT RECOVERY VENTILATION. aera.com.tr

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

PRODUCT RANGE: ROOFTOP PACKAGE

INDUSTRIAL DEHUMIDIFIERS. Advanced range of compressor and desiccant dehumidifiers. Dehumidification and drying

Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

RT-OA TM Rooftop Outdoor-Air (DOAS)

E U R O V E N T CERTIFIED PERFORMANCE

3 rd Generation of VRV. The professional solution for your professional project

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox.

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

Technical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Resolair 62 and 66. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 1,200 4,300 m³/h

Air Handling Units. Quick Guide to Danvent DV

air systems Roomtop RTC-RTH 15 to 30 - L

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

Transcription:

Package Hygienic Air Handling Units PHK Series 1

PHK Series PHK : Standard PHK HP : Heat Pump PHK TO : Clean Room Air Handling Unit Up to 11.000 m 3 /h Airflow Complying with DiN 1946/4 Hygiene Criteria Tests in TUV Laboratories CE Approved PED, LVD and EMC Conditions from Third Party lnstitutions Energy Saving Customized Solutions for AII Hygienic Environments Structural features Production Quality: Casing Strength, Casing Air Leakage, Filter By- Pass Leakage, Thermal Transmittance, Thermal Bridging and Acoustical Insulation In Accordance with EN 1886 Structure & Panel: Self Supporting Frame and Double Sheet Sandwich Panels Profile: Aluminum Alloy (AlMgSi0.5) Sheet Material: 304 Quality Stainless Steel Panel Thickness: 50mm (PHK-50) Air Tightness: EPDM Leak Proof Gaskets to Provide Full Air Tightness On The Panels Heat and Sound Insulation: Rock Wool Heating / Cooling Coil: Cu Pipe / Al Fin, Cu Pipe / Cu Fin, Epoxy Coated Fan: Plug Fan, EC Motor Fan Humidification: Sterile Steam Heat Recovery: Run Around Heat Recovery Compressor: Scroll Hermetic User Panel: Programmable Touch Screen Air Control Technology: Constant Airflow / Pressure Control Capacity / Thermal Control: Proportional Cooling Capacity Control Hot Gas By Pass Power And Regulation: On Board Power and Electric Regulation Board Monitoring / Management: BMS Management Compatibility Types PHK: Standard (%100 Fresh air and mixed air unit / Heat recovery unit) PHK HP: Heat Pump PHK TO: Clean Room Air Handling Unit Options / Accessories User Panel: ProgrammableTouch-Screen Display Heat Recovery: Water to air / Thermodynamics EC Motor Fan 2

PHK Series - Standard PHK Series Technical Specifications 022~101 022 033 045 058 070 085 101 Vantilator Air Flow Rate m 3 /h 2.200 3.300 4.500 5.800 7.000 8.500 10.100 Max. External Static Pressure Pa 800 800 800 800 800 800 800 Vantilator Motor Power kw 1,50 3,00 4,00 5,50 5,50 2x4,00 2x5,50 Aspirator Air Flow Rate 2.200 3.300 4.500 5.800 7.000 8.500 10.100 m 3 /h Max. External Static Pressure Pa 350 350 350 350 350 350 350 Aspirator Motor Power kw 0,75 1,10 1,50 2,20 3,00 2x1,50 2x2,20 ❷ Total Cooling Capacity kw 19,0 23,6 32,0 39,7 44,5 54,1 66,4 Compressor Absorbed Power kw 5,30 5,30 7,10 12,4 11,9 17,0 21,7 ❸ Heating Capacity (Hot Water) kw 34,1 51,5 64,7 84,1 94,6 122,5 140,8 Steam Humidifer ❹ Steam Humidifer Capacity kg/h 10,0 15,0 20,0 30,0 40,0 50,0 60,0 Steam Humidifer Power kw 7,5 11,3 15,0 22,6 30,1 37,6 45,1 Electrical Heater Capacity kw 5,0 7,5 10,0 16,0 16,0 20,0 20,0 Cooling Circuit Refrigerant Compressor Type Number of Compressor(s) 2 2 2 R410a Scroll 2 2 2 2 Number of Circuit(s) 2 2 2 2 2 2 2 Acoustics Data Sound Power - Outside Unit db(a) 59 60 62 62 65 62 64 Sound Power - Air Inlet db(a) 78 81 84 86 90 83 87 Sound Power - Air Outlet db(a) 81 82 84 84 87 84 86 Dimensions Height (H) mm 1.880 2.070 2.150 2.150 2.270 2.270 2.270 Width (W) mm 1.865 2.150 2.150 2.150 2.150 2.255 2.255 Depth (D) mm 910 910 1.060 1.300 1.350 1.840 1.840 Air flow rates are nominal values.ventilator and Aspirator flows can be choosen differently within the range ±10%. ❷ Coil inlet temperature is 19 C WB.Cooling values may differ within the range ±%2 according to coil inlet air DB temperatures. ❸ Coil inlet-outlet temperature is 90 C/70 C and outside temperature is 0 C. ❹ Steam humidifiying capacities are nominal values and for different values it is possible to make selection. 3

PHK HP Series - Heat Pump PHK HP Series Technical Specifications 022~101 022 033 045 058 070 085 101 Vantilator Air Flow Rate m 3 /h 2.200 3.300 4.500 5.800 7.000 8.500 10.100 Max. External Static Pressure Pa 800 800 800 800 800 800 800 Vantilator Motor Power kw 1,50 3,00 4,00 5,50 5,50 2x4,00 2x5,50 Aspirator Air Flow Rate 2.200 3.300 4.500 5.800 7.000 8.500 10.100 m 3 /h Max. External Static Pressure Pa 350 350 350 350 350 350 350 Aspirator Motor Power kw 0,75 1,10 1,50 2,20 3,00 2x1,50 2x2,20 ❷ Total Cooling Capacity kw 21,7 31,8 43,1 56,5 66,8 86,6 103,4 Std. Compressor Power (Cooling) kw 1,90 2,80 4,00 4,30 4,60 6,80 8,60 Inv. Compressor Power (Cooling) kw 5,90 7,70 11,7 16,4 19,7 23,3 28,5 ❸ Total Heating Capacity (Dx) kw 20,9 29,2 40,8 56,8 68,5 85,7 101,0 Inv. Compressor Power (Heating) kw 4,90 6,30 9,70 14,4 17,8 21,0 25,9 ❹ Electrical Preheater kw 12,0 18,0 23,0 29,0 35,0 43,0 51,0 Steam Humidifer ❺ Steam Humidifer Capacity kg/h 10,0 15,0 20,0 30,0 40,0 50,0 60,0 Steam Humidifer Power kw 7,5 11,3 15,0 22,6 30,1 37,6 45,1 Electrical Heater Capacity kw 5,0 7,5 10,0 16,0 16,0 20,0 20,0 Cooling Circuit Refrigerant Compressor Type Number of Compressor(s) 2 2 2 R410a Scroll 2 2 2 2 Number of Circuit(s) 2 2 2 2 2 2 2 Acoustics Data Sound Power - Outside Unit db(a) 59 60 62 62 65 62 64 Sound Power - Air Inlet db(a) 78 81 84 86 90 83 87 Sound Power - Air Outlet db(a) 81 82 84 84 87 84 86 Dimensions Height (H) mm 1.770 1.960 2.080 2.080 2.140 2.160 2.160 Width (W) mm 2.500 2.800 2.850 2.975 2.975 2.975 2.975 Depth (D) mm 910 910 1.060 1.300 1.350 1.840 1.840 Air flow rates are nominal values. Ventilator and Aspirator flows can be choosen differently within the range ±10%. ❷ Coil inlet temperature is 20 C WB. Cooling values may differ within the range ±%2 according to coil inlet air DB temperatures. ❸ Outside temperature is 0 C. ❹ Electrical preheaters are used with 3 stages, when outside temperature below 0 C. ❺ Steam humidifiying capacities are nominal values and for different values it is possible to make selection. 4

PHK TO Series - Clean Room Air Handling Unit PHK TO Series Technical Specifications 033~101 033 045 058 070 085 101 Vantilator Air Flow Rate m 3 /h 3.300 4.500 5.800 7.000 8.500 10.100 Max. External Static Pressure Pa 1.000 1.000 1.000 1.000 1.000 1.000 Vantilator Motor Power kw 3,00 4,00 5,50 5,50 2x4,00 2x5,50 ❷ Total Cooling Capacity kw 18,8 23,5 28,7 34,1 42,7 50,6 Compressor Absorbed Power kw 6,36 7,33 9,00 10,52 13,46 15,58 Total Heating Capacity (Electric) kw 14,0 18,0 24,0 30,0 35,0 42,0 Steam Humidifer ❺ Steam Humidifer Capacity kg/h 15,0 20,0 30,0 30,0 40,0 40,0 Steam Humidifer Power kw 11,3 15,0 22,6 30,1 37,6 45,1 Cooling Circuit Refrigerant Compressor Type R410a Scroll Number of Compressor(s) 2 2 2 2 2 2 Number of Circuit(s) 1 1 1 1 1 1 Acoustics Data Sound Power - Outside Unit db(a) 60 62 62 65 62 64 Sound Power - Air Inlet db(a) 81 84 86 90 83 87 Sound Power - Air Outlet db(a) 82 84 84 87 84 86 Dimensions Height (H) mm 1.960 2.005 2.005 2.105 2.055 2.155 Width (W) mm 1.600 1.760 2.040 2.140 2.530 2.530 Depth (D) mm 1.405 1.505 1.505 1.505 1.665 1.665 Air flow rates are nominal values. Ventilator and Aspirator flows can be choosen differently within the range ±10%. ❷ Coil inlet temperature is 19 C WB. Cooling values may differ within the range ±%2 according to coil inlet air DB temperatures. ❸ Conditions of entry of the air cooling the table values battery 26 C dry thermometer and 50% relative humidity. ❹ Condenser air inlet dry thermometer temperature is 35 C ❺ The values given are nominal steam humidification capacity of different values for device selection is possible. 5

Export Sales Office Address: 53. Cadde 1450. Sokak Ulusoy Plaza No: 9/50 Cukurambar, Ankara, Turkey Email: export@untes.com.tr T+90 (312) 287 91 00 F+90 (312) 284 91 00 Manufacturing Plant-1 Air Handling & Ventilations Systems, Fan Coil Systems Packaged Air Conditioning Systems Address: Istanbul Yolu 37.km Kahramankazan, Ankara, Turkey Manufacturing Plant-2 Water Chiller and Heat Pumps Address: Istanbul Yolu 24.km Saraykoy, Ankara www.untes.com untesklima Untes Heating Air Conditioner Inc. reserves the right to make changes in the products, technical data, figures, designs and materials of the products in the catalog without any notice or information. All contents are copyrighted by Untes. 6