Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Similar documents
GETZ MANUFACTURING PART NO.: MODEL: SYS FILL SGL SV150 NEW VACUFILL SYSTEM

GETZ MANUFACTURING PART # CYLINDER DRYER

MODEL HBX-1 P/N 3G59332

GETZ EQUIPMENT INNOVATORS PART NO.: 9G58619 MODEL: SV1 150 PR VACUFILL SYSTEM (Revised 2/25/14)

GETZ MANUFACTURING PART NO.: MODEL: SV1 100 PR VACUFILL SYSTEM (Revised 6/7/05)

Xaact Spot. Xaact Hot Spot

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

SERVICE MANUAL (v1) UL / ULC. WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK

Installation Instructions / Warranty. Metris 31060XX XX XX1

Carbon Dioxide Sample-Draw Detector Operator s Manual

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

55-Gallon Dispenser Package

2001 Smith Eastern Corporation

55-Gallon Dispenser Package

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6

C-Box 100, H-Box 200 & H-Box 500

Industrial Vacuums, Inc

Operating Instructions for the BBO-1 and BBO-2 Basket Blasters

Installation Instructions / Warranty

Installation Instructions / Warranty

Frosty Factory of America, Inc.

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

Enspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS

OPERATOR S MANUAL SF-12 AND SF12A HI VOLUME WATER HEATER

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

RK-OXY Oxygen Sample-Draw Detector Operator s Manual Part Number: RK Revision: P1 Released: 7/18/02

Installation Instructions / Warranty. Massaud

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

Combustible Gas Sample-Draw Detector Operator s Manual

QUICK PRIME INSTALLATION AND SERVICE MANUAL

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

MAXUM 5 5 Gallon Box Extractor

COBRA -H EXTRACTOR 120V

FiberPRO 2.5 H. Heated Spot Extractor. Operator and Parts Manual E

e Bath Fan with Light User s Guide

Installation Instructions / Warranty

Page 1 of 18. Part# /5/2013

Installation Instructions / Warranty

WATER CLAW SUB-SURFACE FLOOD EXTRACTION TOOL AC016 - AC018. Water Claw 4282 South 590 West Salt Lake City, UT FAX

OWNER'S OPERATION AND MAINTENANCE MANUAL

RK/ RK Oxygen Detector Operator s Manual

AeroVent 3X Product Manual

INSTALLATION GUIDE Little Butler Hot Water Dispensing Faucets and Drinking Water Dispensing Faucets

RK/ RK Oxygen Detector Operator s Manual

Troubleshooting the MPH 24FP Series Pedestal Hydrant

Desiccant Air Drying System

Installation and Maintenance "L" and "LS" Series

Owner s Manual. Terpene Trap CF 1000

Installation Instructions / Warranty

Desiccant Air Drying System

STEAM WALLPAPER STRIPPER MODEL HTW5

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

WATERSHIELIJrM REVERSE OSMOSIS INSTALLA TION MANUAL ~ ~ ~ ~ ~ l ~ TO INSURE THIS PRODUCT AND THE INSTALLATION THEREOF. ~ ~ ~ ~ ~

RK / RK CO 2 Detector Operator s Manual

SSS Intrepid 16 FMS. Manual

Installation Instructions / Warranty

Operator s Manual. Stripping Solution Applicator

LIL SHARK TM AUTOMATIC POOL CLEANER. Model GW8000 OPERATION, TROUBLESHOOTING & PARTS. About Safety

INSTRUCTION MANUAL HS-229G

HOTSPOT. Two Gallon Pump Up Spotter OPERATING & MAINTENANCE

Models: GW/R-T GW/R-2-T GW/R-3-T

PULSE JET DE-ICER OPERATING MANUAL SETUP OPERATION MODEL PJDX-C (REV B) Mode Adjustment Knob WATER SERVICE LINE THAWER FLOW MODE PULSE MODE

MIRAI EXTRACTOR 100V DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THESE INSTRUCTIONS IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY

Owner s Manual Hydro-X Vacuum Pac

Air Dryers & After Coolers Dry Land

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

RK / RK Methane Detector Operator s Manual

RK-03 Hydrogen Detector Operator s Manual

OWNERS MANUAL MODEL EXTERMINATOR VS900 C/R BLACK VAPOR CLEANING SYSTEM SAFETY INSTRUCTIONS OPERATIONS CARE AND MAINTENANCE TROUBLESHOOTING WARRANTY

Installation Instructions / Warranty. Starck 10111XX XX XX1

Pump Out Vacuums Polyethylene & Steel

LITTLE BLASTER SET-UP INSTRUCTIONS FOR SHOT PEEN MACHINES WITH CARTRIDGE TYPE DUST COLLECTORS *** READ BEFORE OPERATING EQUIPMENT***

ENCLOSED UNIT TECHNICAL MANUAL Items # &

Alkaline RO System INSTALLATION MANUAL

e Bath Fan with Light User s Guide

MCD. Corona Discharge Ozone Generators MANUFACTURED BY Bullock Lane San Luis Obispo, CA

BEFORE OPERATING THE MACHINE: WARNING

MKTF CRO-Series 5-Stage Reverse Osmosis System Installation and Maintenance Manual

OPERATIONS MANUAL & PARTS LIST. BX2 Fastracts Extractor. IPC Eagle 3650 Dodd Rd, Eagan MN

Instructions Parts List. 150 psi (1.03 MPa, 10.3 bar) Maximum Air Inlet Working Pressure

HR Powder Feed Hopper

Flat Line Spray Systems Kits

SFD. Suburban Filter Dryer. User Manual Installation Instructions

XT Series Thermostats

CSD-1 CRN Electra Steam, Inc. Instruction Manual for JR06 Steam Generator, JG- and JJ- Models

Operating Instructions Model 4400/VC-115V Portable Powder Filler (115VAC. Model)

e Bath Fan with Light User s Guide

INSTALLATION MANUAL LITTLE BUTLER HOT WATER AND DRINKING WATER FILTRATION FAUCETS LB13250 LB13150 DW13050

Model OP155 Air Dryer

MN908 No. 282C Replaces 282B LB7013

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 715

Heater Installation Kit

PNEUMATIC VACUUMS ATEX Certified For Hazardous Locations OPERATING MANUAL

RK-02 Multi Point Detector Operator s Manual

Owner s Manual Refrigerated Compressed Air Dryer Model F-50

IMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.

HHP-300 EXTRACTOR 120V

FIBERPRO SPOTTER CARPET. 3.5 Gallon Carpet Spotter Machine. Operator and Parts Manual E

Transcription:

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System 1 Revised 11/18/10

2320 Lakecrest Drive, Pekin IL 61554 PH. (888) 747-4389 Fax (309) 495-0625 Website: www.getzequipment.com LIMITED WARRANTY Getz Equipment Innovators warrants its products, and component parts of any product manufactured by Getz Equipment Innovators, to be free from defects in material and workmanship for a period of twelve (12) months from the date of purchase. During the warranty period, any such defects will be repaired or the defective parts replaced (at Getz Equipment Innovators option). The warranty does not cover defects resulting from modification, alteration, misuse, exposure to corrosive conditions, extremely high temperatures, improper installation or maintenance. Warranties on component items not manufactured by Getz Equipment Innovators are provided by others whose warranty, evaluation and judgment will be final. All implied warranties, including, but not limited to, warranties of fitness for purpose and merchantability, are limited to the time periods as stated above. In no event shall Getz Equipment Innovators be liable to incidental or consequential damages. Some states do not allow limitations on how long an implied warranty lasts or the exclusions or limitation of incidental or consequential damages, so that the above limitations or exclusions may not apply to you. Getz Equipment Innovators neither assumes nor authorizes any representative or other person to assume for it any obligation or liability other than as expressly set forth herein. Mobile Service Vehicles: The warranty does not cover: Defects in the chassis and or power unit Defects in separately manufactured products not produced by Getz Equipment Innovators Deterioration due to normal wear, tear, and exposure Repairs made necessary by negligent use, misuse, abuse, loading the service vehicle beyond its gross vehicle weight limitations, accident, acts of God, or other contingencies beyond the control of Getz Equipment Innovators. Repairs deemed necessary by reason of the failure to follow ordinary maintenance procedures. Repairs deemed necessary by reason of alterations done without Getz Equipment Innovators written approval. Warranty Service: All warranty repairs will be performed by Getz Equipment Innovators in Pekin, IL, unless otherwise authorized by Getz Equipment Innovators. Freight: Getz Equipment Innovators will not be liable for shipping or transportation charges to or from customer's location. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. To obtain performance to the obligation of the warranty, write to Getz Equipment Innovators, 2320 Lakecrest Drive, Pekin IL 61554, USA for instructions.

Getz Equipment Innovators 450 ABC Dry Chemical Fill System Table of Contents Page 3. Getz Equipment Filling System 4. Parts List 5. Drawing #2 Console & Filter Assembly 6. Drawing #3 Console Lid Interior 7. Parts List 8. Drawing #3 General Arrangement 9. Assembly Instructions 10. Procedure For Discharging Fire Extinguisher 10. Procedure For Filling Fire Extinguisher 11. Trouble Shooting & Service Aids 11. Recommended Spare Parts Kit 12. Maintenance Kit Instructions 2

Getz Equipment Filling System Power Source: Air Compressor Compressed Air Nitrogen CO2 Vapor * * Customer must remove siphon tube from the supply valve of the liquid CO2 tank to have vapor, and attach an in line moisture trap. (sold separately) Wheeled units should not be discharged into portable discharge hoses. Wheeled units should only be discharged into a 1/2 hose connected to the 1/2 quick connect and ball valve (sold separately). The wheeled unit discharge port is supplied with a restrictor fitting. The correct discharge port and discharge hose is not supplied with this unit as shipped and must be purchased separately. DO NOT REMOVE RESTRICTOR FITTING To get maximum vacuum on your fill system, the operating input pressure may range from 60 to 80 psi for the portable console (70 to 90 for wheeled unit console). To set your regulator for the best results, take the (white) vacuum line (item #28) off of the elbow connector screwed into the filler tube. Turn the on-off switch (item # 7) on and put your finger over the (yellow) vacuum line. Then, adjust the regulator up or down as needed, so that you have maximum vacuum on your gauge (item #10). The 450 lb metal stand is pre-drilled for casters (3G0271). Shipping Size of container and weight (freight only) 29 X 28 X 47 125 LBS Warning: Operator must wear safety glasses when operating filling system equipment 3

DRAWING 1 ITEM NO. PART NUMBER DESCRIPTION QTY. 1 1G0020 PLASTIC JAR 1 2 1G0206 FILTER CAP 1 3 1G0067 JAR FILTER 1 4 N/A N/A 5 1G0205 JAR GASKET 1 6 N/A JAR BRACKET SCREWS 2 7 1G0015 VALVE 3 WAY TOGGLE 1 8 N/A CONSOLE LID 1 9 1G0193 BULKHEAD UNION 3/8-1/4 TUBE,M20.OX1.5 1 10 1G0018 GAUGE 30" VACUUM 2" DIAL 1 11 1G0065 UNION BULKHEAD 1/2" PLASTIC 1 12 1G0207 STEM 1 13 1G0197 BULKHEAD UNION 1/4-1/4 TUBE 2 DRAWING 2 14 1G0047 TUBING POLY 1/4 YELLOW 1 ft 15 1G0198 90 ELBOW 1/4" STEM TO 1/4" TUBE 2 16 1G0199 STRAIGHT ADAPTER 1/4" TUBE -1/8" NPT 1 17 1G0201 SWIVEL SIDE TEE 1/4" TUBE TO 1/8" NPT 1 18 1G0021 VENTURI TEE 1/4 TUBE BRASS 1 19 1G0041 CLAMP 2 - EAR 3/4" 2 20 1G0099 ELBOW POLY BARBED 1/2 X 1/2 1 21 1G0032 TUBING 1/2 I.D. CLEAR VINYL PER FT. 7 22 1G0200 SWIVEL TEE ADAPTER ¼ TUBE X 1/8 1 23 1G0048 TUBING POLY 1/4 WHITE 1 ft 24 1G0046 TUBING POLY 1/4 RED 9 ft 25 1G0327 ELBOW 90 1/4 OD X 1/8 NPT 2 26 3G0082 PUSH BUTTON W/RED COVER AIR INJECTION 1 27 1G0011 BRACKET JAR ASSEMBLY 1 28 1G0017 FILTER HOUSING ASSEMBLY 1 Please order replacement parts from: Getz Equipment Innovators Pekin, IL 61554 Phone (888) 747-GETZ (4389) Fax (309) 309-495-0625 www.getzequipment.com 4

5 DRAWING 1

6 DRAWING 2 - Inside View

DRAWING 3 ITEM NO. PART NUMBER DESCRIPTION 25 1G0032 FILL LINE - TUBING 1/2 I.D. CLEAR VINYL PER FT. 26 1G0033 DISCHARGE LINE - TUBING 1/2 REINFORCED CLEAR VINYL PER FT 27 1G0084 VALVE BALL 1/2" BRASS 28 1G0048 VACUUM LINE - TUBING POLY 1/4 WHITE 29 1G0091 CONE FILL TUBE RUBBER 30 3G0036 CONSOLE 31 1G0020 JAR 32 1G0325 (1G0326) PUSH BUTTON AIR INJECTION (RED COVER) 33 1G0046 AIR INJECTION LINE - TUBING POLY 1/4 RED 34 1G0234 LID 450 HOPPER PLASTIC 35 1G0034 LEVER LOCK RING FOR HOPPER 36 1G0250 HOPPER FILTER 37 N/A HOPPER 38 N/A METAL STAND Please order replacement parts from: Getz Equipment Innovators Pekin, IL 61554 Phone (888) 747-GETZ (4389) Fax (309) 309-495-0625 www.getzequipment.com 7

8 DRAWING 3

Assembly Instructions 1. Remove Filling System from shipping container 2. Remove lid and filter by releasing the band assembly and inside you will find an assortment of hoses and the console(s). 3. Remove all items from inside the hopper. 4. Separate the red stand from the hopper. 5. Attach the clear ½ vinyl tubing (item #25) to the 45 degree outlets at the base of the hopper; attach using provided worm gear clamps. 6. Place hopper back into stand. 7. Remove the cover from the console(s) by unscrewing the (4) lid screws from the console box. 8. Mount console(s) to the stand or wall centering it above the filling system approximately 36 above the floor. Use at least two of the four mounting holes. 9. Attach the 6 clear ½ vinyl tubing to the vent line port (item #11) on the base of the portable console(s) on the right side by pushing it over the hose barb. It is best if the vent line is directed to an exhaust fan. 10. Mount ring bracket onto the stand. 11. Attach one end of the red ¼ poly tubing to the 90 degree elbow connected to the red push button valve by pushing it firmly into the connector. The push button valve is mounted to the red stand above the white ring brackets. Attach the opposite end of the red ¼ poly tubing to shop air before regulators, max 125 psi. Caution: A moisture trap must be used to prevent moisture mixing with the dry chemical when fluffing. 12. Unscrew rubber cone (item #29) from filler tube. Bring filler tube and ½ clear vinyl up through the bottom of the ring bracket. Screw rubber cone back onto filler tube. 13. Attach white ¼ poly tubing (item #28) to the vacuum port on the base of the console (left side) by pushing it firmly into the connector. 14. Screw the discharge line (braided line with 1/2 ball valve, item #26) into the black bulkhead on the side of the hopper 15. Connect 3/8 white poly tubing to the fitting on the top of the console by pushing the air line into the fitting. Attach opposite end of 3/8 tubing to air compressor or regulator. Maximum incoming air should be no more than 80 psi for regular consoles. Maximum incoming air should be no more than 90 psi for wheeled unit consoles. 9

Portable Extinguisher Discharge Instructions 1. Make sure extinguisher is pressurized. 2. If extinguisher is not pressurized and is full/partially full of chemical, hook up re-charge adapter and pressurize to factory recommended pressure on gauge. 3. Remove hose and connect correct discharge adapter with male quick coupler (item #38) into valve assembly of extinguisher. 4. Connect portable discharge hose assembly to the discharge adapter on extinguisher. 5. Ensure that powder recovery lid and filter are secured with the lever lock ring (item #35) to hopper. 6. Close wheeled unit ½ ball valve (item #27) 7. Close ball valve (item #40) and partially discharge extinguisher into the discharge hose to inspect chemical. 8. If chemical is proper chemical for extinguisher being discharged, open ball valve (item #40) to allow chemical into hopper and allow nitrogen pressure to escape trough the powder recovery filter. 9. Discharge extinguisher and when pressure gauge reaches zero, disconnect discharge assembly hose Filling Empty Dry Chemical Extinguisher Instructions * Review Manufacturer s manual for additional recharge/filling instructions 1. Visually check with inspection light that empty dry chemical extinguisher is dry and not corroded. 2. Take clear fill line and extend it to the top of the empty cylinder to be filled. 3. Place rubber cone (item #29) into top of cylinder neck with a clockwise ¼ turn. 4. Turn off-on valve (item #7) to ON position until extinguisher reaches recommended weight. Turn valve to OFF once it is filled. **If chemical returns to plastic jar before reaching correct weight, let it settle then turn valve back on to reach desired weight. 5. Remove fill line from cylinder neck and place in ring bracket. 10

Trouble Shooting for Fill System To determine if problem is in console, take the (white) vacuum line (item #28) off of the elbow connector screwed into the filler tube. Turn the on-off switch (item # 7) on and put your finger over the (white) vacuum line (item #28). Suction should be present and gauge should read a minimum 15 of vacuum for the portables console (23 of vacuum for wheeled unit console). IF NOT, make sure jar gasket (item # 5) is in place and make sure jar is tight against gasket. DO NOT blow air through console or jar assembly. If there is suction at the end of the (white) vacuum line (item #28) the trouble is NOT in the console. Most problems are commonly outside the console such as: lumpy chemical, moist chemical or a plugged fill hose. If the console is not working properly, it is recommended to replace the venturi (item # 18). 1. Chemical will not flow when: a. Extinguisher is not vacuum tight (i.e. a cartridge extinguisher with leaky cartridge receiver). b. There is a kink in a hose. c. The fill line and/or vacuum line are clogged. d. Jar filter assembly on console is not properly sealed (must be tight). e. Air supply is not regulated and maintained at 60 80 PSI for portables console (70-90 for Wheeled Unit console) 2. Overflow jars located under console should never be allowed to fill more than halfway before emptying. a. Filter element in jars may be blown clean with an air gun (or similar tool) weekly. b. Replace filter every six months. Recommended Maintenance Getz Equipment Innovators has designed their plastic dry chemical fill systems to be the most maintenance-free available and to provide the longest equipment life. Nevertheless all equipment needs maintained and simple steps can be done to assure your fill system(s) continues to operate at optimum performance. To maintain optimum fill system performance we recommend the following maintenance items at a minimum. These recommendations are based on averages so frequencies may vary depending on number of extinguishers serviced using the dry chemical fill system(s). Daily - Empty the plastic overflow jar when dry chemical reaches the line marked on the jar. Allowing the dry chemical to go above the line on the jar will allow chemical to flow back into the console tubing causing damage to the venturi, on/off valve, and vacuum gauge. Weekly - Clean Hopper Lid Filter. Vacuum the inside of the filter. If there is dry chemical caked onto the filter is needs to be replaced. - Clean Jar Filter. Use only 10-15 psi to blow and clean the jar filter. - Discharge Hose. Look for burn/soft spot at end by coupling and replace when worn 11 Annually (See Instructions Below) - Replace Hopper Lid Filter - Replace Jar Filter - Replace Jar Gasket - Replace Venturi

Maintenance Kit Instructions 100/150 lb Dry Chemical Fill Systems (Portables) Console 3G0089 1G0024 - Hopper Lid Filter (See Drawing #3) 1. Unlatch the hopper lever lock ring (35) and remove with the plastic hopper lid (34). 2. Remove old hopper lid filter (36) and discard. 3. Install new hopper lid filter and reinstall plastic hopper lid (beveled edge on top) and lever lock ring. 1G0067 Jar Filter & 1G00205 Jar Gasket (See Drawing #1) 4. Unscrew the Plastic Jar (1) counterclockwise from the bottom of the console and the metal Filter Cap (2). The Jar Filter (3) should be loose to remove after the metal Filter Cap is removed. 5. Remove the old Jar Gasket (5). Gently clean the Filter Housing Assembly (28) being careful not to blow air up into the Housing/Console that will force chemical into the tubing. 6. Install the new Jar Gasket and new Jar Filter with the metal Filter Cap. Install the Plastic Jar. 1G0021 Venturi (See Drawing Below) 1. Remove the four corner screws on the front console lid to access the inside. 2. Remove vent line (5) from the poly elbow (6). 3. Use a 7/16 open end wrench to remove the two brass nuts at (1) and (2) and pull the clear and yellow ¼ tubing with those brass nuts from the venturi (4). 4. Unscrew (counterclockwise) the brass nut (3) using the ear clamp. This will leave the nut (3) in the vent tube (5) and the piece of ¼ clear plastic tube. 5. Remove the brass nut on the new venturi that has the piece of ¼ clear plastic tubing. The ¼ clear plastic tubing can be removed from the new venturi if the same tubing stayed in the vent tube (5). 6. Install the new venturi into the brass nut (3) that was left in the vent tube (5). 7. Remove the other two brass nuts in the new venturi. 8. Insert ¼ clear and yellow tubing and tighten brass nuts (1) and (2). 9. Insert vent line (5) into the poly elbow (6). 10. Replace front Console lid and tighten four corner screws. 12