Annunciator unit. Application

Similar documents
Annunciator Unit SACO 16 D1. Product Guide

Analog Annunciator Unit SACO 16 A3. Product Guide

www. ElectricalPartManuals. com Annunciator unit Features Self-contained microprocessor-based annunciator unit with 64 alarm channels Application

REA 105 Arc Protection Module. Operator s Manual

SACO 16D3 Annunciator unit. User s manual and Technical description

Panel Mounted Fault Annunciator Series

SPEF 3A2 C. Fault indicator. User s manual and Technical description SPEF 3A2 C. f n SPA. Serial port. RS AA Ser.No.

Universal fault annunciator for panel mounting

Panel Mounted Fault Annunciator Series

1. General Safety Block diagram Description of operation Connections Commissioning...11

AO Annunciator Module

Window facia fault annunciators

VAMP 121. Arc protection unit. User manual

AIS750 Series Alarm Annunciator

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

TCM-2 Thyristor Control Module DATA SHEET

Parameterisable compact fault annunciator with permanent display

VAMP 120 & 121. Arc flash detection units. Product picture

Panel Mounted Fault Annunciator Series

ME 3011C / Alarm Indication / Quick Reference Guide

Multi-Gas-Controller MGC2

VAmP 120. Arc Flash Protection Units. Arc Protection. Customer benefits

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

THE SOLUTION. MSM-Product family OPERATING MANUAL. A fault annunciator of the. BSM Basic fault annunciator for panel mounting. INFOwww.ees-online.

Standard Devices. Electronic Alarm Indication Systems. ME 3011b

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

VAMP 120 & 121. Arc Flash Protection Units. Arc Protection. Customer benefits

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

DRAFT 20 October 2014

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Danfoss gas detection units

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

20 Light Remote Annunciator

FireNET Plus Wiring Instructions

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)

Installation & Operating Instructions

ME 3011 compact. Electronic Alarm Indication Systems. Power Station Control Systems. Automation Equipment. Power Distribution Control Systems

Automation System TROVIS 5400 Boiler Controller TROVIS 5474

MSM - Expansion modules

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Bionics Instrument. Alarm Handling. Gas Alarm Systems

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

For Complete Fire and Gas Solutions

Interface Modules for SENTRI

Ordering Key. Dielectric strength

Control and Annunciator Panels. Compact systems of signalling and control

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Annuciator Logic Controllers

/8 DIN Level Indicator

Model A1600 Series Annunciator

System 9000TS Sequence of Events Recorder

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Emergency power automatics MS-2. High resistance to shock, vibrations and transients. All output are 2A relay contacts

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Model A1700 Series Annunciator

Fire control panels FC360

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

APPLICATION DATA SHEET

Carbon Monoxide Transmitter

M1000 Alarm Annunciator

Instructions for the fan motor control system with integrated wiring terminals SILVER C

APPLICATION DATA SHEET

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

Two-Channel Gas Controller

Danfoss gas detection unit Type GD Heavy Duty

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

On the job around the clock 24/7: Fire detection systems

1.7. Insulation fault evaluators EDS460/490 EDS461/491

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

Danfoss gas detection units

RS485 MODBUS Module 8AI

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

Installation, Operating and Maintenance Manual

Insulation fault evaluator EDS460-DG

WM3000 WIRELESS MODULES

LINETRAXX VMD420. Multi-functional voltage relay for 3(N)AC systems, frequency/overvoltage/undervoltage, phase, phase failure, asymmetry

Gas Controller Module GC-06

CTT8 TEMPERATURE MONITOR DEVICE

DS 96/48 P. Digital indicator. Short manual 41/33-89 EN Rev. 00 DIM

SUPREMATouch. Modular Fire & Gas Detection System

Snifter ATEX22 VERSION. User Manual. Distributor

Rules for Intruder Alarm Systems

S304 and S305 Dust Emission Monitors. User Manual. Distributor

General Routing Interface

X11CA COMPUTER ANNUNCIATORS

Line Isolation Monitor (LIM) LIM2000plus

ESP TECHNOLOGIES LIMITED

MO n : 12JMC rév A

I/A Series 716C 1/16 DIN Temperature Controller

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Transcription:

Issued: April 1999 Status: April 1999 Version: B/09.11.2001 Data subject to change without notice Features Flexible, field-customizable 16-channel annunciator unit Alarm channels activated by normally open or normally closed contact Four four-output relays, i.e. two for group realarms, one for an audible device and one for the self-supervision system Parameter selection and adjustment from front panel or via serial interface First-out alarm indication with clear fourdigit display on the front panel Extensive data communication via the serial interface and the SPA bus Sophisticated hardware and software selfsupervision system for maximum operational reliability under the most demanding environmental conditions Powerful software support for parameterization of the unit via the serial interface Member of the SPACOM product family and ABB s Substation Automation system CE marking according to the EC directive for EMC Application The analog annunciator unit is used in a variety of applications requiring supervision of alarm and signalling contacts in power plants, substations and industrial process installations. The alarm unit is also approved for use in off-shore installations and marine applications. Further, the annunciator unit can be used in any application where on/off signals are to be supervised. The annunciator unit provides immediate fault recognition, fault identification and visual and audible alarm in an abnormal process situation. The annunciator unit also provides a means for subsequent fault analyses, which means that corrective measures can be carried out without delay and full control of the process can be maintained. The annunciator units can be used as independent stand-alone units, or they can be connected together via a fibre-optic bus to form complete supervision, event sequence reporting and data acquisition systems. The annunciator unit is a member of SPA- COM, the ultimate integrated secondary equipment system for power systems. 1

Design The annunciator unit is composed of four modules: an alarm annunciator module, an input/output module, a connection module and a power module, housed in a rugged aluminium casing. The alarm annunciator module includes 16 alarm channels. The channels are activated by normally open or normally closed process contacts. The required 48 V dc contact circuit voltage is generated and supervised by the annunciator unit. Each channel can separately be assigned a start delay from 5 ms to 160 s. On activation of a channel the visual indicator of the channels starts blinking. One of five standardized blinking systems according to ISA and DIN can be selected by the operator at commissioning. The annunciator is provided with a first-out indication given via the four-digit alphanumerical display on the front panel. The firstout alarm is indicated with a letter A and the channel number. The annunciator unit is also provided with an event register, which stores the last nine events in chronological order. The event register can be read via the push-buttons and the display on the front panel or via the serial interface. The annunciator holds four output relays, two of which are used as group alarm output relays. One of four modes of operation can be selected for the realarm output relays. One output relay is dedicated for the selfsupervision system and one for the control of an audible device, such as a buzzer or a horn. Any information generated in the annunciator unit can be read by a hierarchically superior system via the serial interface. Data communication The annunciator unit is provided with a serial interface on the rear panel. By means of a bus connection module type SPA-ZC 17/S or SPA-ZC 21/S the unit can be connected to the fibre-optic SPA bus. The bus connection module type SPA-ZC 21/S is powered from the host unit, whereas the bus connection module SPA-ZC 17/S is provided with a built-in power unit, which can be fed from an external secured power source. The unit communicates with higher-level data acquisition and control systems over the SPA bus. Self-supervision The annunciator incorporates a sophisticated self-supervision system which increases the availability of the device and the reliability of the system. The self-supervision system continuously monitors the hardware and the software of the unit. The system also supervises the operation of the auxiliary supply module and the level of the electronics voltages generated by the module. If a permanent fault is detected, the fault indicator on the front panel is lit, the output relay of the self-supervision system operates and the outputs are blocked. Auxiliary supply voltage The auxiliary supply of the relay is obtained from an internal plug-in type power supply module. Two auxiliary power module types are available: type SPGU 240A1 for the supply voltage range 80 265 V ac/dc and type SPGU 48B2 for the supply voltage range 18 80 V dc. The power supply module forms the internal voltages required by the annunciator. 2

Technical data 7DEOH$ODUPFKDQQHOV Capacity Type of field contact or type of incoming alarm signal 16 channels Make contact (default) Break contact Rising edge Falling edge Field contact voltage 48 V dc ±20% Loop current of closed field contact circuit 4 ma ±20% Channel input and reset delay time, field-selectable values 5 ms, 20 ms (default), 100 ms, 1 s, 5 s, 20 s, 60 s or 160 s 7DEOH([WHUQDODFNQRZOHGJHUHVHWLQSXWV Channel acknowledge/reset Audible device reset The control voltages for the acknowledge/reset circuits are obtained from the internal supply Make contact Make contact 48 V dc ±20% 7DEOH5HIODVKVLJQDORXWSXWV Reflash group alarm outputs Audible device output Internal self-supervision output Rated contact current/breaking voltage Breaking capacity for dc currents when the load time-constant L/R 40 ms at the voltage levels 48/ 110/220 V dc 2 relays, NO contact (NC by soldering) 1 relay 1 relay 3 A/250 V ac/dc 1 A/0.25 A/0.15 A 7DEOH'DWDFRPPXQLFDWLRQ Transmission mode Coding Data transfer, selectable Electrical/optical bus connection module, powered from the host unit Electrical/optical bus connection module, powered from the host unit or from an external power source for plastic core cables for glass fibre cables for plastic core cables for glass fibre cables Fibre-optic serial bus ASCII 4800 or 9600 Bd SPA-ZC 21BB/S SPA-ZC 21MM/S SPA-ZC 17BB/S SPA-ZC 17MM/S 7DEOH$X[LOLDU\VXSSO\PRGXOHV Type of module SPGU 240A1 rated voltages U n 110/120/230/240 V ac 110/125/220 V dc operative range 80 265 V ac/dc SPGU 48B2 rated voltages U n 24/48/60 V ac operative range 18 80 V dc Power consumption under quiescent/operation ~10 W/~25 W conditions 3

7DEOH7HVWVDQGVWDQGDUGV Test voltages - alarm and acknowledge/reset inputs to frame - output relay contacts to frame - auxiliary supply circuits to frame - inputs, outputs and supply circuits between themselves Dielectric test voltage (IEC 60255-5) 2 kv, 50 Hz, 1 min Impulse test voltage (IEC 60255-5) 5 kv, 1.2/50 µs, 0.5 J Disturbance tests HF test voltage (IEC 60255-6) 2.5 kv, 1 MHz Environmental conditions Ambient service temperature range -10 +55 C Ambient transport and storage -40 +70 C temperature range Long term damp heat withstand <95%, +40 C, 56 d/a (IEC 60068-2-3) Degree of protection by enclosure when IP 54 panel-mounted Weight ~4.5 kg Block diagram Alarm channels 1...16 Remote reset/ackn. Supply 1 2 Group reflash outputs Self-supervision and audible alarm output SPA-buss connection 1 2 16 1 2 SWIM 2A1 Internal supply Fig. 1 Block diagram 4

Ordering :KHQRUGHULQJSOHDVHVSHFLI\ Ordering information Ordering example 1. Type designation and quantity, 5 pieces 2. Order number RS 811 016-AA 3. Auxiliary voltage U aux = 110 V dc 4. Accessories - 5. Special requirements - 2UGHUQXPEHUV The last two letters of the order number indicate the auxiliary voltage U aux of the annunciator unit as follows: RS 811 016-AA, -BA AA equals U aux = 80 265 V ac/dc BA equals U aux = 18 80 V dc References $GGLWLRQDOLQIRUPDWLRQ Colour brochure and SACO 16D3 Colour brochure SACO User s manual 1MRS 750230-MDS EN 1MRS 750756-MDS EN 34 SACO 16 EN1 5

ABB Oy P.O. Box 699 FIN-65101 Vaasa, Finland Tel +358 10 224 000 Fax +358 10 224 1094 www.abb.com/substationautomation