MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Similar documents
DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

Advance Release September 2009

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

technical guide Water-Cooled Self-Contained Units

Water-Cooled Self-Contained Units

SKYPAK II, 3 Ton Series, gives you a

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Commercial High-Efficiency Condensing Units

SKYPAK II, 3 Ton Series, gives you a

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Commercial High-Efficiency Condensing Units

SKYPAK II Heating & Cooling Self Contained Packages

Split System Heat Pumps

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

VertiCool Aurora Engineering Guide

"SWVP - SWHP" COMMERCIAL WATER SOURCE HEAT PUMPS & AIR CONDITIONERS

PACKAGE AIR CONDITIONER

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

MACH N-407 Heat Pump Air-Cooled Chiller

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

MAC N-407 Air-Cooled Chiller

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

SECTION AIR-COOLED SPLIT SYSTEM AIR CONDITIONING UNITS

WCH5**4. Product Specifications

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

C13-Series Engineering Guide

PAR5. Product Specifications

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

PAJ3. Product Specifications

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers

R4H4. Product Specifications

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers

AIR COOLED SPLIT SYSTEMS LIGHT COMMERCIAL RANGE UN-PRC001-EN

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

N4H4. Product Specifications

SECTION WATER-SOURCE UNITARY HEAT PUMPS

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

STANDARD EFFICIENCY PACKAGE A/C UNIT to 216 MBtuh

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

N4A6. Product Specifications

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

High Heat COP. High/Low Stage

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

R4H4. Product Specifications

JCseries EVAPORATIVE CONDENSER. engineering data

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

VariCool VAV Engineering Guide

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

Next-Gen Uni-Pak 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

KCC Centrifugal Fan Air Cooled Condensers

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL FEATURING

MERIT SERIES Up Flow / Horizontal

MAC-120HE-03 Air-Cooled Chiller

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

50TM TFF COMBINATION HEATING/COOLING UNITS

Call us today! (800)

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

Unit Dimension. Unit Nomenclature DEHUMIDIFIER NOMENCLATURE UNIT VOLTAGE: 2: 240/1/60 5: /3/60 9: 480/3/60 8: 600/3/60

The Premium Quality Fan Coil Units for Vertical, Horizontal (Left or Right) Application with Direct Expansion, Hydronic or Electric Heat

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

50TM COMBINATION HEATING/COOLING UNITS

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

EMI ENGINEERING SUBMITTAL

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

Today s Value-Added Performers. The DRY-30 Series Dehumidifiers from DryAire Systems.

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

CeilMate TM Series 3 and 4 tons of cooling capacity. Ceiling Mounted Systems. Air Handler with Remote Condensing Unit Air Handler designed for R-410A

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

Transcription:

1 of 3 Cooling Capacity [Btuh] 24,800 * Condensing Unit SEER: 13.0 ** Condensing Unit CFM: 1,600 Condenser Fan No./Type: 1/CENTRIFUGAL Diameter x Width [in]: 10x10 Drive: Adjustable Belt Motor HP: 0.5 Condenser Coil Face Area: 5.83 [sq ft] Rows/FPI: 4/16 * Net Capacity in combination with ESH024 horizontal air handling unit. **Rated in accordance with DOE test procedures and ARI Standard 210-240. Compressor No./Type: 1/Scroll Refrigerant Circuits: 1/Independent Capacity Steps (%): 100/0 Suction Line OD (in): 3/4 Liquid Line OD (in): 3/8 Refrigerant: Charge: R-410A n/a Unit shipped with Nitrogen holding charge only Operating Weight [lbs.]: 387 Shipping Weight [lbs.]: 407 CONDENSER FAN PERFORMANCE EXTERNAL STATIC PRESSURE - Inches W.C. OUTDOOR 0.2 0.4 0.6 0.8 CFM RPM BHP RPM BHP RPM BHP RPM BHP 1600 750 0.29 852 0.35 948 0.42 996 0.46 ELECTRICAL DATA VOLTAGE COMPRESSOR CONDENSER FAN MIN. CCT. QTY RLA LRA HP FLA AMPACITY Max Overcurrent Protection 208-230/1/60 1 @ 13.5 58.3 0.50 4.5 21.38 30 208-230/3/60 1 @ 8.6 55.0 0.50 2.2 12.95 20 35.0 KSH024 Condensing Unit Performance 30.0 65 Gross Cooling Capacity (MBh) 25.0 20.0 75 85 95 105 115 15.0 10.0 30 32 34 36 38 40 42 44 46 48 50 Saturated Suction Temperature (F) Performance data calculated at 15 o F subcooling and 20 o F superheat. Figures shown do not include capacity loss due to refrigerant line pressure drop. KSH024 PERFORMANCE DATA Form 145.28-PA1 (1108)

2 of 3 GENERAL All models 2-5 tons ship as fully assembled and wired units. Units include "Scroll" type, R-410A, hermetic compressor(s), aluminum fin/copper tube condenser coil, condenser fan and motor, and all necessary controls. Units are shipped with a Nitrogen holding charge only. All models are designed for suspended mounting via integral structural channels. CABINET All cabinets are completely constructed of heavy gauge galvanized steel. The unit interior is insulated with 1/2" thick, 2-lb density insulation. Service panels are equipped with lifting handles for ease of removal and handling. Duct flanges for condenser discharge and condenser intake are provided with the unit for field installation. REFRIGERANT CIRCUITS All models utilize "Scroll" type hermetic compressors. Compressors are mounted on rubber isolators to minimize vibration transmission. Internal overload protection is provided. External high pressure and low pressure cut-out switches are included in each compressor control circuit. Crankcase heaters are standard on all models. The 2-5 ton units have a single refrigeration circuit. CONDENSER COILS The condenser coil is constructed of internally enhanced copper tubes mechanically bonded to rippled aluminum plate fins. Coils are employed in a draw-thru configuration. CONDENSER FAN AND MOTOR Forward curved, double inlet and double width centrifugal blowers are used for condenser air movement. Blower wheels are fabricated of galvanized steel. Blowers employ solid steel shafts, supported in permanently lubricated ball bearings. All blowers are belt driven. Variable-pitch motor sheaves allow for field adjustment of blower rpm. Motor shall be 1800 RPM, open drip proof design. Three-phase motors are provided with external manual reset overload protection. Single-phase motors feature auto reset internal overloads. ELECTRICAL/CONTROLS All units are completely factory wired with all necessary controls. A manual reset circuit is also provided on each compressor control circuit in the event of high/low pressure cut-out. A 24 volt control circuit, with oversize transformer, is provided for field connection. FACTORY INSTALLED OPTIONS Corrosion Resistant Coatings. Condenser coil shall receive a 1-mil thickness of a cathodic epoxy type electro-deposition coating, applied in a multiple dip and bake process. Anti-Short Cycle Timer. Time delay relay will be provided for each compressor circuit. Compressor will be locked out for 5 minutes when thermostat contact opens, or there is a momentary power outage. FIELD INSTALLED OPTIONS Low Ambient Control. Head pressure control damper kit will allow unit operation down to 0 F ambient. Damper assembly mounts on condenser air intake. The kit includes damper actuator and low pressure switch bypass timer(s). MECHANICAL SPECIFICATION Form 145.28-PA1 (1108)

3 of 3 KSH024 & KSH036 Form 145.28-PA1 (1108)

1 of 3 Cooling Capacity [Btuh] 36,100 * Condensing Unit SEER: 13.0 ** Condensing Unit CFM: 1,950 Condenser Fan No./Type: 1/CENTRIFUGAL Diameter x Width [in]: 10x10 Drive: Adjustable Belt Motor HP: 0.75 Condenser Coil Face Area: 5.83 [sq ft] Rows/FPI: 4/16 * Net Capacity in combination with ESH036 horizontal air handling unit. **Rated in accordance with DOE test procedures and ARI Standard 210-240. Compressor No./Type: 1/Scroll Refrigerant Circuits: 1/Independent Capacity Steps (%): 100/0 Suction Line OD (in): 3/4 Liquid Line OD (in): 3/8 Refrigerant: Charge: R-410A n/a Unit shipped with Nitrogen holding charge only Operating Weight [lbs.]: 408 Shipping Weight [lbs.]: 438 CONDENSER FAN PERFORMANCE EXTERNAL STATIC PRESSURE - Inches W.C. OUTDOOR 0.2 0.4 0.6 0.8 1.0 CFM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 1950 864 0.47 949 0.55 1032 0.63 1112 0.72 - - ELECTRICAL DATA VOLTAGE COMPRESSOR CONDENSER FAN MIN. CCT. Max Overcurrent QTY RLA LRA HP FLA AMPACITY Protection 208-230/1/60 1 @ 14.1 77.0 0.75 5.5 23.13 35 208-230/3/60 1 @ 9.0 71.0 0.75 2.6 13.85 20 460/3/60 1 @ 5.6 38.0 0.75 1.3 8.30 15 575/3/60 1 @ 3.8 36.5 0.75 1.0 5.75 15 45.0 KSH036 Condensing Unit Performance 65 40.0 75 Gross Cooling Capacity (MBh) 35.0 30.0 85 95 105 115 25.0 20.0 30 32 34 36 38 40 42 44 46 48 50 Saturated Suction Temperature (F) Performance data calculated at 15 o F subcooling and 20 o F superheat. Figures shown do not include capacity loss due to refrigerant line pressure drop. KSH036 PERFORMANCE DATA Form 145.28-PA2 (1108)

2 of 3 GENERAL All models 2-5 tons ship as fully assembled and wired units. Units include "Scroll" type, R-410A, hermetic compressor(s), aluminum fin/copper tube condenser coil, condenser fan and motor, and all necessary controls. Units are shipped with a Nitrogen holding charge only. All models are designed for suspended mounting via integral structural channels. CABINET All cabinets are completely constructed of heavy gauge galvanized steel. The unit interior is insulated with 1/2" thick, 2-lb density insulation. Service panels are equipped with lifting handles for ease of removal and handling. Duct flanges for condenser discharge and condenser intake are provided with the unit for field installation. REFRIGERANT CIRCUITS All models utilize "Scroll" type hermetic compressors. Compressors are mounted on rubber isolators to minimize vibration transmission. Internal overload protection is provided. External high pressure and low pressure cut-out switches are included in each compressor control circuit. Crankcase heaters are standard on all models. The 2-5 ton units have a single refrigeration circuit. CONDENSER COILS The condenser coil is constructed of internally enhanced copper tubes mechanically bonded to rippled aluminum plate fins. Coils are employed in a draw-thru configuration. CONDENSER FAN AND MOTOR Forward curved, double inlet and double width centrifugal blowers are used for condenser air movement. Blower wheels are fabricated of galvanized steel. Blowers employ solid steel shafts, supported in permanently lubricated ball bearings. All blowers are belt driven. Variable-pitch motor sheaves allow for field adjustment of blower rpm. Motor shall be 1800 RPM, open drip proof design. Three-phase motors are provided with external manual reset overload protection. Single-phase motors feature auto reset internal overloads. ELECTRICAL/CONTROLS All units are completely factory wired with all necessary controls. A manual reset circuit is also provided on each compressor control circuit in the event of high/low pressure cut-out. A 24 volt control circuit, with oversize transformer, is provided for field connection. FACTORY INSTALLED OPTIONS Corrosion Resistant Coatings. Condenser coil shall receive a 1-mil thickness of a cathodic epoxy type electro-deposition coating, applied in a multiple dip and bake process. Anti-Short Cycle Timer. Time delay relay will be provided for each compressor circuit. Compressor will be locked out for 5 minutes when thermostat contact opens, or there is a momentary power outage. FIELD INSTALLED OPTIONS Low Ambient Control. Head pressure control damper kit will allow unit operation down to 0 F ambient. Damper assembly mounts on condenser air intake. The kit includes damper actuator and low pressure switch bypass timer(s). MECHANICAL SPECIFICATION Form 145.28-PA2 (1108)

3 of 3 KSH024 & KSH036 Form 145.28-PA2 (1108)

1 of 3 Cooling Capacity [Btuh] 48,700 * Condensing Unit SEER: 13.0 ** Condensing Unit CFM: 2,500 Condenser Fan No./Type: 1/CENTRIFUGAL Diameter x Width [in]: 12x11 Drive: Adjustable Belt Motor HP: 1.0 Condenser Coil Face Area: 7.19 [sq ft] Rows/FPI: 4/16 * Net Capacity in combination with ESH048 horizontal air handling unit. **Rated in accordance with DOE test procedures and ARI Standard 210-240. Compressor No./Type: 1/Scroll Refrigerant Circuits: 1/Independent Capacity Steps (%): 100/0 Suction Line OD (in): 7/8 Liquid Line OD (in): 1/2 Refrigerant: Charge: R-410A n/a Unit shipped with Nitrogen holding charge only Operating Weight [lbs.]: 494 Shipping Weight [lbs.]: 524 CONDENSER FAN PERFORMANCE EXTERNAL STATIC PRESSURE - Inches W.C. OUTDOOR 0.2 0.4 0.6 0.8 1.0 CFM RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 2500 645 0.53 749 0.63 812 0.74 872 0.86 945 0.98 ELECTRICAL DATA VOLTAGE COMPRESSOR CONDENSER FAN MIN. CCT. Max Overcurrent QTY RLA LRA HP FLA AMPACITY Protection 208-230/1/60 1 @ 19.9 109.0 1.00 6.3 31.18 50 208-230/3/60 1 @ 13.1 83.1 1.00 3.3 19.68 30 460/3/60 1 @ 6.1 41.0 1.00 1.5 9.13 15 575/3/60 1 @ 5.0 34.0 1.00 1.1 7.35 15 60.0 KSH048 Condensing Unit Performance 65 55.0 75 Gross Cooling Capacity (MBh) 50.0 45.0 40.0 35.0 85 95 105 115 30.0 25.0 30 32 34 36 38 40 42 44 46 48 50 Saturated Suction Temperature (F) Performance data calculated at 15 o F subcooling and 20 o F superheat. Figures shown do not include capacity loss due to refrigerant line pressure drop. KSH048 PERFORMANCE DATA Form 145.28-PA3 (1108)

2 of 3 GENERAL All models 2-5 tons ship as fully assembled and wired units. Units include "Scroll" type, R-410A, hermetic compressor(s), aluminum fin/copper tube condenser coil, condenser fan and motor, and all necessary controls. Units are shipped with a Nitrogen holding charge only. All models are designed for suspended mounting via integral structural channels. CABINET All cabinets are completely constructed of heavy gauge galvanized steel. The unit interior is insulated with 1/2" thick, 2-lb density insulation. Service panels are equipped with lifting handles for ease of removal and handling. Duct flanges for condenser discharge and condenser intake are provided with the unit for field installation. REFRIGERANT CIRCUITS All models utilize "Scroll" type hermetic compressors. Compressors are mounted on rubber isolators to minimize vibration transmission. Internal overload protection is provided. External high pressure and low pressure cut-out switches are included in each compressor control circuit. Crankcase heaters are standard on all models. The 2-5 ton units have a single refrigeration circuit. CONDENSER COILS The condenser coil is constructed of internally enhanced copper tubes mechanically bonded to rippled aluminum plate fins. Coils are employed in a draw-thru configuration. CONDENSER FAN AND MOTOR Forward curved, double inlet and double width centrifugal blowers are used for condenser air movement. Blower wheels are fabricated of galvanized steel. Blowers employ solid steel shafts, supported in permanently lubricated ball bearings. All blowers are belt driven. Variable-pitch motor sheaves allow for field adjustment of blower rpm. Motor shall be 1800 RPM, open drip proof design. Three-phase motors are provided with external manual reset overload protection. Single-phase motors feature auto reset internal overloads. ELECTRICAL/CONTROLS All units are completely factory wired with all necessary controls. A manual reset circuit is also provided on each compressor control circuit in the event of high/low pressure cut-out. A 24 volt control circuit, with oversize transformer, is provided for field connection. FACTORY INSTALLED OPTIONS Corrosion Resistant Coatings. Condenser coil shall receive a 1-mil thickness of a cathodic epoxy type electro-deposition coating, applied in a multiple dip and bake process. Anti-Short Cycle Timer. Time delay relay will be provided for each compressor circuit. Compressor will be locked out for 5 minutes when thermostat contact opens, or there is a momentary power outage. FIELD INSTALLED OPTIONS Low Ambient Control. Head pressure control damper kit will allow unit operation down to 0 F ambient. Damper assembly mounts on condenser air intake. The kit includes damper actuator and low pressure switch bypass timer(s). MECHANICAL SPECIFICATION Form 145.28-PA3 (1108)

3 of 3 KSH048 & KSH060 Form 145.28-PA3 (1108)

1 of 3 Cooling Capacity [Btuh] 61,800 * Condensing Unit SEER: 13.0 ** Condensing Unit CFM: 2,900 Condenser Fan No./Type: 1/CENTRIFUGAL Diameter x Width [in]: 12x11 Drive: Adjustable Belt Motor HP: 1.5 Condenser Coil Face Area: 7.19 [sq ft] Rows/FPI: 4/16 * Net Capacity in combination with ESH060 horizontal air handling unit. **Rated in accordance with DOE test procedures and ARI Standard 210-240. Compressor No./Type: 1/Scroll Refrigerant Circuits: 1/Independent Capacity Steps (%): 100/0 Suction Line OD (in): 7/8 Liquid Line OD (in): 1/2 Refrigerant: Charge: R-410A n/a Unit shipped with Nitrogen holding charge only Operating Weight [lbs.]: 496 Shipping Weight [lbs.]: 526 CONDENSER FAN PERFORMANCE OUTDOOR CFM EXTERNAL STATIC PRESSURE - Inches W.C. 0.2 0.4 0.6 0.8 1.0 1.2 RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 2900 723 0.79 800 0.84 871 1.07 935 1.20 996 1.55 1057 1.42 - - ELECTRICAL DATA VOLTAGE COMPRESSOR CONDENSER FAN MIN. CCT. Max Overcurrent QTY RLA LRA HP FLA AMPACITY Protection 208-230/3/60 1 @ 16.0 110.0 1.50 4.6 24.60 40 460/3/60 1 @ 7.8 52.0 1.50 2.1 11.85 15 575/3/60 1 @ 5.7 38.9 1.50 1.7 8.83 15 1.4 75.0 KSH060 Condensing Unit Performance 65 70.0 75 65.0 85 Gross Cooling Capacity (MBh) 60.0 55.0 50.0 45.0 95 105 115 40.0 35.0 30 32 34 36 38 40 42 44 46 48 50 Saturated Suction Temperature (F) Performance data calculated at 15 o F subcooling and 20 o F superheat. Figures shown do not include capacity loss due to refrigerant line pressure drop. KSH060 PERFORMANCE DATA Form 145.28-PA4 (1108)

2 of 3 GENERAL All models 2-5 tons ship as fully assembled and wired units. Units include "Scroll" type, R-410A, hermetic compressor(s), aluminum fin/copper tube condenser coil, condenser fan and motor, and all necessary controls. Units are shipped with a Nitrogen holding charge only. All models are designed for suspended mounting via integral structural channels. CABINET All cabinets are completely constructed of heavy gauge galvanized steel. The unit interior is insulated with 1/2" thick, 2-lb density insulation. Service panels are equipped with lifting handles for ease of removal and handling. Duct flanges for condenser discharge and condenser intake are provided with the unit for field installation. REFRIGERANT CIRCUITS All models utilize "Scroll" type hermetic compressors. Compressors are mounted on rubber isolators to minimize vibration transmission. Internal overload protection is provided. External high pressure and low pressure cut-out switches are included in each compressor control circuit. Crankcase heaters are standard on all models. The 2-5 ton units have a single refrigeration circuit. CONDENSER COILS The condenser coil is constructed of internally enhanced copper tubes mechanically bonded to rippled aluminum plate fins. Coils are employed in a draw-thru configuration. CONDENSER FAN AND MOTOR Forward curved, double inlet and double width centrifugal blowers are used for condenser air movement. Blower wheels are fabricated of galvanized steel. Blowers employ solid steel shafts, supported in permanently lubricated ball bearings. All blowers are belt driven. Variable-pitch motor sheaves allow for field adjustment of blower rpm. Motor shall be 1800 RPM, open drip proof design. Three-phase motors are provided with external manual reset overload protection. Single-phase motors feature auto reset internal overloads. ELECTRICAL/CONTROLS All units are completely factory wired with all necessary controls. A manual reset circuit is also provided on each compressor control circuit in the event of high/low pressure cut-out. A 24 volt control circuit, with oversize transformer, is provided for field connection. FACTORY INSTALLED OPTIONS Corrosion Resistant Coatings. Condenser coil shall receive a 1-mil thickness of a cathodic epoxy type electro-deposition coating, applied in a multiple dip and bake process. Anti-Short Cycle Timer. Time delay relay will be provided for each compressor circuit. Compressor will be locked out for 5 minutes when thermostat contact opens, or there is a momentary power outage. FIELD INSTALLED OPTIONS Low Ambient Control. Head pressure control damper kit will allow unit operation down to 0 F ambient. Damper assembly mounts on condenser air intake. The kit includes damper actuator and low pressure switch bypass timer(s). MECHANICAL SPECIFICATION Form 145.28-PA4 (1108)

3 of 3 KSH048 & KSH060 Form 145.28-PA4 (1108)