OWNER S MANUAL. General Ventilation Fans Electric Driven. PAL Series (Incl. 24 & 30) HD Series (Incl. -T & -S) 0316_01A

Similar documents
OWNER S MANUAL. Power Blowers TM Cone Air Flow (CAF) - Electric Driven. (Incl. BASIC) 0216_01A

Industrial Ventilation Equipment

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

Operating Manual Model BP500 and BP500 IJ Tape Dispenser

MN908 No. 282C Replaces 282B LB7013

3800 North Mill Road Vineland, NJ USA Tel: Fax: Web: Rev. A

22In. Oscillating Pedestal Fan. Owner s Manual

OWNER S MANUAL MULTIPURPOSE UTILITY AIR MOVER PLEASE READ AND SAVE THESE INSTRUCTIONS X-400WFK (WITH FILTER KIT) ITEM NO:

1 HP Air Mover. Owner s Manual

High-Velocity Floor Fan

User s Manual and Operating Instructions

16 OUTDOOR MISTING FAN

HYBRID DRYER. PDH1 - PDH2 Series. Save These Instructions

TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive. Installation & Operator s Instruction Manual

HYBRID DRYER. PDH1 - PDH2 Series WARNING: OPERATOR MUST READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THIS EQUIPMENT.

HGW-308R Wall Mountable Micathermic Heater w/ Remote. Model No. HGW-308R Soleus Air International

SPECIFICATIONS FEATURES

Installation and Operation Manual

Model: C C Ambassador 20. Automatic Carpet Scrubber OPERATION SERVICE PARTS CARE

HM & HM Ultra Thin Micathermic Heater. Model No. HM / HM Soleus Air International

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

Cleanshield HEPA 550 Owner's Manual

HI Industrial Utility Heater HI Soleus Air International

Service Manual Models CPH2 & CPH3

Model 2016, 2025, 2025BN, 2025ST Staging Cabinets Instruction Manual

PROFESSIONAL AIR MOVER OWNER S MANUAL

GX200/ GX200L. Owner s Manual

20In. Oscillating Wall-Mount Fan. Owner s Manual

OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS WHOLE ROOM RADIATOR HEATER. Model: HO-0221 THERMOSTAT

DH07, DH07A /DH08, DH08A CONVECTED AIR DISH HEATERS

Operation and Maintenance Manual 120V/60HZ

P4000 Construction Heater

BIG BEAR VORTEX FAN MODEL #BB-2

M Series Fan Filter Units

Instruction Manual. 36 in. and 42 in. Popcorn Staging Cabinets

CONVEYOR TOASTER MODEL QCS QCS Installation and Operation Instructions 2M-HG0657 Rev. D 6/13/05

Owner's Manual Paramount 65X GRAPHIC LAMINATION PRODUCTS

CABINET INFRARED HEATER

OWNER S MANUAL. Model No. B-16 STAND PET DRYER

Thank You & Congratulations On Your Purchase of: ARBE Model # SS-206 Table Top Dust Collector

Operation and Maintenance Manual GLACIER TALL BASE CS5-16-VD-TB CS5-18-VD-TB2 120V/60HZ

Store Name: Location: Date Purchased: Serial Number (located on back of unit):

40E ELECTRIC FAN HEATER

VARIABLE SPEED GRINDER OWNER S MANUAL R MANUAL VERSION SERIAL #

HR1-08R-21 Reflective Heater Operating Instructions. Model No. HR1-08R Soleus Air International

Instruction Manual. Cheddar Easy All-In-One Cheese Corn Shop

MANUFACTURING NUMBERS: CORN CAROUSEL. Model CC-19 Series P/N /99. Owner s Manual

Instruction Leaflet. Read instructions before operating. Retain for future reference.

ANYWHERE. U.S. Patent(s) Pending INSTRUCTION MANUAL WARRANTY CERTIFICATE

User s Manual and Operating Instructions

HC Ceramic Tower Heater Operating Instructions HC Soleus Air International

Operation and Maintenance Manual 120V/60HZ

Floss Machine Instruction Manual Model #3024

Model No. CZ2011O Oak Finish CZ2011C Cherry Finish CZ2011W Walnut Finish CZ2011B Black Finish DIGITAL QUARTZ INFRARED HEATER OWNER S MANUAL

Integra Family. Operations Manual. Models: Integra TX SS, Integra HD, Integra DS, Integra DS LA, Integra UHS, Machine Name: Serial Number:

Air Storm Fans. Air Storm 18 Fiberglass Fan Installation and Operation Manual

Operation and Maintenance Manual BLIZZARD50 CS6-50-VD 120V/60HZ

UB20 12V DC. Owner s Manual

Field Top Mounted Condensing Unit

60In. Ceiling Fan. Owner s Manual

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

Operating Instructions & Parts Manual Models 99533, 99532

USER GUIDE. This manual covers the description, cautions, operation and maintenance of Super Vac confined space electric ventilators CONTENTS

Manual No: Revision: E. Groundwater Sensor. Installation Guide

GRIND PRO DUAL OR DISC SANDER. Operator Manual

ATD PEDESTAL FAN INSTRUCTIONS

OPERATION, SERVICE & PARTS MANUAL

TACH-IT MODEL #3568 SEMI-AUTOMATIC TWIST TIE MACHINE OPERATION MANUAL AND PARTS LIST

40E ELECTRIC FAN HEATER

OPERATIONS MANUAL DALPH1002, DALPH1503 PELLET HEATERS PALPH1002, PALPH1503 PLATE HEATERS. Alliance Products, LLC Murfreesboro, TN

USER GUIDE CONTENTS. Please take the time to read this manual before operating the ventilator. Save this guide for future reference.

Instruction Manual. Cheese Warmer with Pump

Indoor/Outdoor Electric Patio Heater Model No: HP Operating Instructions HP Soleus Air International

owner s manual & parts list

Quest Power Electric Heat EHS 62 Pro

SELF-CONTAINED POWER MISTER

Direct-Drive Gas Power Blowers

Instruction Manual. Dogeroo, Super Dogeroo, and Mini Dogeroo

HotPoly Tote Tank / IBC Heaters (TTH Series)

Ledco XL-44 Wide Format Pouch Laminator

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

MRS-6 Maxi-Guard II. Model: C , 12, 13, 14 OPERATION SERVICE PARTS CARE. Revised 2/02

Instruction Manual. Double Candy Apple Cooker

INSTALLATION AND OPERATING INSTRUCTIONS. For Reliance Controls Emergency Power Transfer Switch Kit Model Number 30216BRK

Operating Instructions (ENG) MODEL: 115 V UL LISTING FOR 1/2 HP MODELS ONLY. Read instructions before operating the machine J 07/05/07

CL & CLG Clamp Mount Mixers

EBAC MODEL KOMPACT INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

FD Heavy Duty Feeder for FD 280 Tabbing System

E1.5 ELECTRIC FAN HEATER

Infrared Portable Space Heater

User s Manual and Operating Instructions

CAR-MON DUST COLLECTORS SERIES 207, 2410, 3015

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

Installation and Maintenance Manual Please retain this manual for future reference.

B.I.C.A Built-In Coffee Appliance

W Model 1RKU2 w/optional Wall mount. Unit Model Weight (Lbs) Kilowatts Volts- Phase Amps Fan Output Heat Output

IMPORTANT SAFETY INFORMATION:

36 & 48 E-Z Cone Fan. Installation & Operator s Instruction Manual (Direct Drive)

5-Gallon Pail Mixer OWNERS MANUAL M-2000 SERIES MIXERS. Contents: Page: Safety, General & Receiving... 2 Operation... 3 Parts List...

Wheelbarrow Mixer Operations Manual

Transcription:

OWNER S MANUAL General Ventilation Fans Electric Driven HD Series (Incl. -T & -S) PAL Series (Incl. 24 & 30) 0316_01A

INTRODUCTION Thank you for choosing Tempest Technology Corporation for your ventilation needs. With this manual we hope to help you operate your Tempest product safely and to its full potential. Maintained according to the specifications set in this manual, it is not uncommon to receive many years of use and operation out of your Tempest equipment. This manual is produced solely for the use of purchasers and operators of Tempest Technology Corporation equipment. Any reproduction, retransmission, or other use of the contents of this manual without written consent of Tempest Technology Corporation is strictly prohibited. It is the intent of this manual to provide the owner/operator of Tempest Technology Corporation products with both general and specific information regarding the safe and proper operation and maintenance of the equipment described within. CONTACT If after careful review, any questions arise concerning any portion of this manual, please contact Tempest Technology Corporation for assistance: ABOUT TEMPEST Tempest Technology Corporation is the leading manufacturer of products and accessories for environmental management in firefighting and industrial applications. Tempest began as a manufacturer of gasoline and electric powered blowers for the fire service. Fire departments use the Tempest Power Blower TM to provide Positive Pressure Ventilation / Attack (PPV/PPA) to remove heat, gases and smoke from the interior of a burning structure. Tempest has expanded into other industries and found new applications for its products. The Tempest Power Blower TM and PPV/PPA are used by industrial applications to control dust, fumes and unhealthy gases like carbon monoxide, greatly improving safety in confined spaces. Tempest Technology Corporation has earned a reputation as a leader and innovator in the air movement industry and continues in that role today. TEMPEST TECHNOLOGY CORP. 4708 N. BLYTHE AVENUE FRESNO, CA 93722 Toll Free: 800.346.2143 t: 559.277.7577 f: 559.277.7579 response@tempest.us.com www.tempest.us.com TABLE OF CONTENTS ABOUT TEMPEST 2 SAFETY GUIDE 3 GENERAL INFORMATION 3 GENERAL VENTILATION FAN DATA 4 OPERATING PROCEDURES 5 MAINTENANCE PROCEDURES 6 TROUBLESHOOTING 6 NOTES 7 WARRANTY BACK COVER POSITIVE PRESSURE VENTILATION/ATTACK 2

SAFETY GUIDE Failure to follow the operating, maintenance and lubrication requirements set forth in this manual may result in serious personal injury or death and/or damage to equipment or property. The following WARNING statements indicate potentially hazardous conditions for operators and equipment. Make certain that anyone who works on or around the fan has read and fully understands the safety precautions listed. 1. Carefully read this owner s manual before attempting to operate, service or disassemble any part of your Tempest Ventilator. 2. DO NOT operate the unit when mentally or physically fatigued or impaired. 3. Stay away from rotating parts; avoid wearing loose jackets, shirts, and ties. Keep hands and feet away from moving parts. 4. Keep all unauthorized personnel at a safe distance from the fan. 5. Keep all guards in place. DO NOT make repairs while the unit is running. DO NOT operate if any guard or grille is not in place. 6. Always wear eye protection. Loose debris can be picked up in the air stream and flown in the air. 7. Hearing protection is required. Engine and air noise may exceed safe db levels. 8. Always ensure proper voltage and amperage is delivered to your Tempest Ventilator. 9. Only a qualified technician should perform repairs or maintenance on electric components. 10. Never operate your Tempest Ventilator with electric components exposed. 11. Never operate your Tempest Ventilator with damaged, exposed or frayed wiring. 12. It is the sole responsibility of the owner/operator to develop procedures for proper use of the Tempest Ventilator in accordance with generally accepted ventilation techniques as well as the organization s own operating procedures, before placing the unit into service. GENERAL INFORMATION BLOWER IDENTIFICATION Each Tempest Ventilator has a part number as well as a serial number. The part number identifies the type of unit (size, drive, etc.) while the serial number relates to information referencing the date of manufacture. This information is useful should it become necessary to contact the factory regarding your ventilator. SERIAL NUMBER LOCATIONS The serial number is typically located on the frame just right or left of the motor mount. Please write the Serial Number of your Tempest Ventilator in the spaces below. This will aid us in identifying which model you have when assisting you. Model (Part No.) Date Serial No. WARRANTY Warranty information on your unit can be found on the back page of this manual. For further information, please contact Tempest Technology Corp. 3

GENERAL VENTILATION FAN DATA TYPE: DRIVE: EP OPTION: BLADE: BUSHING: SHROUD: FRAME: TILT MECHANISM: GRILLE: WHEELS: General Ventilation Fan Single Speed Models: Direct-Drive Single Speed 110-120V, 60Hz or 220-230V, 50Hz Electric Motor, GFCI Compatible Variable Speed Models: Direct-Drive Variable Speed 110-120V, 60Hz or 220-230V, 50Hz Electric Motor, GFCI Compatible, NEMA-4 Rated Drive Hazardous Locations Class I, Group C & D and Class II, Group F & G Environments AirFlex Fiberglass Reinforced Polyamide Blades Keyed Shaft and Set or Cap Screws HD Models: Rolled Steel w/ Powder-Coat Finish PAL-24 Models: Turbo 2000 Tapered Aluminum w/ Durable Powder-Coat Finish Rugged, Lightweight, Square-Steel or Round-Steel Tubing with Powder-Coat Finish 24-HD Models: Manual Set Leg Extensions, Three Position Tilt, +15, +5, 0 24-HD-T Models: Manual Set, Eight Position Fan/Motor Tilt, 10 Increments, +30 to -50 24-HD-S Models: Manual Set, 360 Swivel & Eight Position Fan/Motor Tilt, 10 Increments, 0 to -80 Continuous Circular-Wound, External-Weld Steel Wire with 8 Tie Points for Additional Safety Meets UL & European CE Safety Standards PAL & HD Models (Non -S): 10 Solid Rubber w/ High Strength Polymer Hubs 24-HD SPECIFICATIONS: 24-HD 913-1160 24 1.0 12,867 28.75 x 26.00 x 34.50 120 lbs. 24-HD-EP 913-1161 24 1.0 12,867 28.75 x 26.00 x 34.50 125 lbs. 24-HD-T SPECIFICATIONS: 24-HD-T-EP 913-1180 24 1.0 12,867 31.00 x 32.25 x 64.25 150 lbs. 24-HD-S SPECIFICATIONS: 24-HD-S 913-1170 24 1.0 12,867 31.00 x 23.00 x 29.00 89 lbs. 24-HD-S-EP 913-1171 24 1.0 12,867 31.00 x 23.00 x 29.00 94 lbs. 24-HD-S-VSR 913-1172 24 2.0 15,663 31.00 x 23.00 x 29.00 117 lbs. PAL-24 SPECIFICATIONS: PAL-30 SPECIFICATIONS: PAL-24 913-1065 24 1.0 12,867 31.00 x 23.00 x 40.75 133 lbs. PAL-24-EP 913-1070 24 1.0 12,867 31.00 x 23.00 x 40.75 138 lbs. PAL-24-VSR 913-1060 24 2.0 15,663 31.00 x 23.00 x 40.75 158 lbs. PAL-30 913-1080 30 1.5 13,000 33.00 x 22.00 x 35.50 133 lbs. PAL-30-VSR 913-1085 30 2.0 15,072 33.00 x 22.00 x 35.50 158 lbs. 4

OPERATING PROCEDURES PRE-OPERATION After receiving and unpacking your fan, be sure to carefully inspect it for any damage that might have occurred during shipping. Should you find any damage: PLEASE NOTIFY TEMPEST TECHNOLOGY CORP. IMMEDIATELY AT 800.346.2143 OR RESPONSE@TEMPEST.US.COM. OPERATION SET-UP, STARTING AND STOPPING Assuming the previous Pre-Operation and safety instructions have been followed, the fan is now ready to run. WHEN USING A GENERATOR, IT IS IMPERATIVE THAT THE GENERATOR BE RUNNING AT FULL CAPACITY BEFORE PLUGGING IN ANY ELECTRIC FAN. ALWAYS VERIFY SUFFICIENT GENERATOR OUTPUT BEFORE USE. IMPROPER VOLTAGE SUPPLY MAY DAMAGE UNIT AND VOID WARRANTY. CAUTION: DO NOT MOVE THE FAN WHILE IT IS IN OPERATION. SEVERE PERSONAL INJURY IS POSSIBLE AS WELL AS DAMAGE TO THE FAN. ALWAYS SHUT-DOWN THE FAN PRIOR TO MOVING. SET-UP Position the fan in the desired location, making sure it is placed on a flat, hard and debris free surface. SINGLE SPEED REQUIREMENTS Based on 110-120V fan on 20 amp circuit. Motor HP 0.3 1.0 1.5 Starting Amps 10.9 48.0 54.6 Starting Watts 1300 6,000 6,300 Runnings Amps 6.3 13.4 14.2 Runnings Watts 756 1,900 2,100 MAXIMUM POWER CORD LENGTH Based on 1 fan on 20 amp circuit. Motor HP 0.3 1.0 1.5 14 Gauge 215 60 45 12 Gauge 330 95 65 10 Gauge 550 150 115 8 Gauge 850 240 190 6 Gauge 1,350 380 300 STARTING - VARIABLE SPEED 1. Check that the toggle switch is set to STOP. 2. Plug the fan cord into power source receptacle. If power is properly brought to the control, the POWER LED and the STATUS LED indicators will be lit. 3. Engage START toggle. The toggle is momentary switch to start. The center position is the run location. 4. Adjust the rheostat knob to the desired speed/load. STOPPING 1. Stop unit before unplugging from power source. Make sure toggle is set to STOP. NOTE: The following sections cover separate operating instructions for both single speed and variable speed fans. Please be sure to follow the operating instructions specific to your particular fan model. STARTING - SINGLE SPEED No Switch: Plug fan into power source. Unit will begin running automatically. With Switch: 1. Ensure fan toggle is switched to the OFF position. 2. Plug fan into power source. 3. Switch toggle to the ON position. STOPPING No Switch: Unplug unit from power source or switch off power source. p/n 400-090 VARIABLE SPEED DRIVE With Switch: Stop unit before unplugging from power source. Make sure toggle switch is set to STOP. 5

MAINTENANCE PROCEDURES Although Tempest electric ventilators are designed to eliminate most maintenance issues, it is imperative that the fans be inspected before startup on each use. Please review the following list before using this product. MAINTENANCE SCHEDULE EVERY USE INSPECT FAN FOR DAMAGE AND FIX IF ANY TIGHTEN/REPLACE ANY LOOSE OR MISSING PARTS EVERY MONTH OR 10 HOURS INSPECT & CLEAN SHROUD & GRILLES IMPORTANT: Always operate the fan in an area free of debris which may be pulled into the unit s blades. If you suspect the fan s blade may have contacted a hard object, thorough inspection of the blade assembly should be conducted immediately to ensure safety. You may contact Tempest Technology Corp. in order to find out how to properly inspect the blade assembly. TROUBLESHOOTING Various factors can contribute to or be the sole cause of problems for electric fans. This section will identify some of these problems and provide solutions to correct them. SINGLE SPEED FAN FAILS TO START Make sure the unit is connected to the power source. Thoroughly check the power cord. If the cord shows any signs of serious wear it may need to be replaced before running properly. Many fans are equipped with an automatic reset. This reset will kill power to the fan when the unit is at risk of overheating. Let the fan cool and attempt to start it again. There may be damage to the internal wiring. Have a qualified technician or electronics specialist examine the fan circuitry and wiring and make any necessary repairs. If your Tempest Single Speed Fan is not running after completing the steps mentioned above, please contact us at 800.346.2143 or response@tempest.us.com. VARIABLE SPEED IF THE POWER AND THE STATUS LEDS DO NOT LIGHT UP Make sure the unit is connected to the power source. Confirm that adequate power is being supplied to fan. If power supply is adequate, DISCONNECT FAN FROM POWER SOURCE and check for loose or faulty wiring on fan electrical system and have a qualified professional perform repairs if needed. Connect fan to power source and attempt restarting. If fan still does not run, contact Tempest at 800.346.2143 or response@ tempest.us.com. FAN SURGES WHEN RUNNING ON GENERATOR: Check that the generator meets the proper voltage output to operate the fan. If fan is still surging, contact Tempest at 800.346.2143 or response@tempest.us.com. 24-HD & 24-HD-T FAN DOESN T REST EVENLY ON LEVEL SURFACE Ensure fan is resting on a level surface, free from any debris or objects which may be located under its feet. Make sure the unit is not running. Then, place the unit on its back, resting it on its rubber stops (or wheels on -T models). Using a 9/16 wrench, adjust the jam nut located just above the foot pad to loosen the foot (it may be necessary to put 24-HD models in the first tilt position to gain access to the nut). Screw the foot pad in or out as necessary to make it level with the fan s other feet. Once adjusted, re-tighten the jam nut against the upper portion of the fan s leg and set the fan upright again. 6

NOTES 7

WARRANTY INFORMATION Except as otherwise set forth below, any claim by Customer with reference to the Goods sold shall be deemed waived by the Customer unless submitted in writing to Tempest within the earlier of (i) five (5) business days following the date Customer discovered, or by reasonable inspection should have discovered, any claimed breach of the foregoing warranty, or (ii) thirty (30) calendar days following the date of shipment. Any cause of action for breach of the foregoing warranty shall be brought within one (1) year from the date the alleged breach was discovered or should have been discovered, whichever occurs first. Limited Power Blower Warranty Tempest warrants to the original purchaser that all Tempest gasoline and electric powered blowers (except the engine or motor and drive) will be free from original defects in workmanship and material, under normal-use conditions, and Tempest will replace any defective power blower part (except the engine or motor and drive) if returned during the applicable warranty period, for the time frame indicated below: Firefighting Industry: Five (5) years from date of shipment Industrial/Rental Industry: One (1) year from date of shipment Blower Engine / Motor & Drive Warranty The engines manufactured by Honda and Briggs & Stratton are covered by a separate manufacturer s warranty for a period of two (2) years. Electric motors manufactured by Magnetek, Marathon, Baldor, Franklin Electric and Multi-Fan are covered by a separate manufacturer s warranty for a period of one (1) year. Note: Unauthorized repair or modification of the factory assembly or parts voids the warranty. All information provided in this operations manual is subject to change without notice. Please refer to our website for the most recent sales terms and conditions. Tempest Technology Corporation 4708 N. Blythe Avenue, Fresno, CA 93722 t: 559.277.7577 f: 559.277.7579 response@tempest.us.com www.tempest.us.com