Cooling Capacity CFM in. w.c. (125 Pa)

Similar documents
Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM range

Wt. Lbs Model Number (BTUH) Hz

TSTAT0101SC Recommended (order separately)

Cooling Capacity CFM in. w.c. (125 Pa)

TSTAT0101SC Recommended. Cooling Capacity CFM in. w.c. (125 Pa)

TSTAT0201CW Recommended (sold separately)

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

T9MPV. 2- Stage Variable Speed 90. Flexibility. Comfort. Efficiency. Quality. Service (05/2006)

T9MPV SmartComfort VS90 Product Specifications

H9MPV. 2- Stage Variable Speed 90. Flexibility. Quality. Comfort. Efficiency. Service (7/2004)

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

Product Data PG9MXA 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

TECHNICAL SPECIFICATIONS

COMFORT CONTROL 90 PLUS WITH DUAL TWO-STAGE UPFLOW GAS FURNACES

TECHNICAL SPECIFICATIONS

Multi-Position Gas Furnaces

Product Data. 925SA PREFERREDt SERIES SINGLE -STAGE 4-WAY MULTIPOISE CONDENSING GAS FURNACE, SERIES A LIMITED WARRANTY*

Product Data. 59TP5A Performance Boost Two---Stage Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY*

Product Data A {Jurisdictions where warranty benefits cannot be conditioned on registration

Product Data. 59SP5A Performance Boost, Single---Stage Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY*

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE

Product Data. 58STA/STX WAY MULTIPOISE INDUCED --- COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 160

Product Data. 59TN6A InfinityR Two---Stage, Variable Speed Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY*

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

Ruud Achiever Series Multi position Gas Furnaces

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat

Ruud Achiever Plus Series Multi-position Gas Furnaces

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Product Data PG96VAT TWO -STAGE, 4 -WAY MULTIPOISE VARIABLE -SPEED CONDENSING GAS FURNACE

Product Data. ama. 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces. 58BLA Low-Boy. Copyright 1996 Carrier Corporation

Product Data OBM/OVM. MULTIPOISE OIL FURNACE INPUT CAPACITIES 70,000 thru 154,000 BTUH THE LATEST IN OIL FURNACE TECHNOLOGY

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

Rheem Classic Series Multi-position Gas Furnaces

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE 3 -PASS PRIMARY HEAT EXCHANGERS FLOW -THROUGH SECONDARY HEAT EXCHANGERS MONOPORT INSHOT BURNERS

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

MERIT SERIES Downflow

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

Product Data 987MA EVOLUTIONR MODULATING 4 -WAY MULTIPOSE, VARIABLE SPEED CONDENSING GAS FURNACE, SERIES A LIMITED WARRANTY*

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

MULTI POSITION GAS FURNACE

Product Data. S QuieTecht noise reduction system. S SmartEvapt -Humidity control when using a Thermidistat Control

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

Product Data PG95XAT CONDENSING GAS FURNACE SERIES B STANDARD FEATURES

Product Data. 58PAV Energy-Efficient Induced-Combustion Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh. 80% AFUE At Budget Price

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

Product Data. S Unit may also be sidewall vented with an approved A S OVL units equipped with optional ECM 2.3 Variable

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. )

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

Product Data. 59SC2A Comfort Series Single---Stage Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY*

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. )

GAS FURNACES. RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above)

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

TECHNICAL SPECIFICATIONS

Product Data. S HYBRID HEAT Dual Fuel System compatible S All models are chimney friendly when used with accessory vent kit

Product Data STANDARD FEATURES

Model PG9MAB MULTIPOISE CONDENSING GAS FURNACE SS-PG9MAB-01. Time Roman FEATURES. burners seldom, if ever, needs cleaning.

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

GAS FURNACES CLASSIC 95% A.F.U.E. HIGH EFFICIENCY UPFLOW GAS FURNACES

G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2.

MULTI POSITION GAS FURNACE

Rheem Classic Plus Series Multi position Gas Furnaces

Product Data. 59MN7A Infinityr Modulating Way Multipoise Condensing Gas Furnace Series 100

Product Data. S Noise elimination combustion system. S Compact design only 33-1/3 in. (846 mm) tall

RG7D 1-Stage Heat Series

Rheem Classic Series Downflow/ Horizontal Gas Furnaces

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG:

Product Data. 58STA/STX WAY MULTIPOISE INDUCED --- COMBUSTION GAS FURNACE Input Capacities: 45,000 thru 155,000 Btuh Series 140, 150

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Ruud Acheiver Series Upflow Gas Furnaces

90TJ SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to kw] (All Models 90% A.F.U.E. or Above)

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

GAS FURNACES. ACHIEVER SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES w/ecm MOTOR

G61MP. ELITE SERIES Multi Position Two Stage Heat G A S F U R N A C E S. AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal Add on Cooling 2.

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY UPFLOW GAS FURNACES

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

GAS FURNACES SELECT 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

Product Data. 925TA PREFERREDt SERIES TWO -STAGE 4-WAY MULTIPOISE CONDENSING GAS FURNACE, SERIES B

XV80i. Upflow/Horizontal 80% 2-Stage, Variable Speed Gas-Fired Furnace with Whole House Air Cleaner PUB. NO

Product Data. 58MCA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 111 Input Capacities: 40,000 thru 120,000 Btuh

Product Data. 58TUA WeatherMaker 8000TS with Comfort Heat Technology Upflow Furnace. Series 120 Input Capacities: 40,000 thru 135,000 Btuh

GAS FURNACES 90 PLUS WITH DUAL COMFORT CONTROL TWO-STAGE UPFLOW GAS FURNACES

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:

Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace

Product Data. 925SA PREFERREDt SERIES SINGLE -STAGE 4-WAY MULTIPOISE CONDENSING GAS FURNACE, SERIES A. Select Models

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

GAS FURNACES SILHOUETTE II PLUS 2 LXE TWO STAGE 80% A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

Transcription:

93% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 93% AFUE, all models all positions F9MES 50 Hz Product Specifications Certified to leak 2% or less of nominal air conditioning CFM delivered when pressurized to 1-inch water column with all present air inlets, air outlets, and condensate drain port(s) sealed TOUGHER Flame roll out sensors standard Adjustable heating blower OFF delay Factory set blower ON delay RPJ primary heat exchanger Stainless steel secondary heat exchanger High temperature limit control prevents overheating Direct ignition with Silicon Nitride ignitor High quality, corrosion resistant, prepainted steel cabinet EASIER TO INSTALL AND SERVICE Direct vent (2 pipe), single pipe venting or ventilated combustion air 24 VAC humidifier terminal & electronic air cleaner terminal 35 (889mm) high, for ease of installation Simplified, factory installed internal condensate drain system Innovative knobs for easy door removal and secure attachment Factory shipped for natural gas, with propane gas conversion kits available Four position upflow/downflow/horizontal (left/right) installation F9MES1002120 and F9MES1202420. Upflow/horizontal installation for F9MES1402420. At least twelve different venting configurations Through the casing flue pipe for counterflow or horizontal applications with accessory (order separately) Concentric vent available Self diagnostics with super bright LED Slide out heat exchanger and blower assembly Illustrations and photographs are only representative. Some product models may vary.! WARNING CARBON MONOXIDE POISONING AND FIRE HAZARD Failure to follow this warning could result in personal injury, death, and/or property damage. This furnace is not designed for use in recreation vehicles or outdoors. This furnace is designed for use in manufactured (Mobile) homes when an optional Mobile Home accessory kit is installed. Failure to follow this warning could result in personal injury, death, and/or property damage. THIS MODEL 93.0 Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org. Model Number Input (MBTUH) Efficiency AFUE Cooling Capacity CFM range @.5 in. w.c. (125 Pa) Dimensions H x W x D Inches (Millimeters) Shipping Wt. Lbs (Kg) F9MES1002120A 100,000 93% 1341-2069 35 x 21 x 29-1/2 (889 x 533 x 750) 171 (78) F9MES1202420A 120,000 93% 1330-2026 35 x 24-1/2 x 29-1/2 (889 x 622 x 750) 188 (85) F9MES1402420A 140,000 93% 1323-2011 35 x 24-1/2 x 29-1/2 (889 x 622 x 750) 192 (87) Specifications are subject to change without notice. 440 21 4700 02 4/25/14

MODEL NUMBER IDENTIFICATION GUIDE DIGIT POSITION 1 2 3 4 5 6,7,8 9,10 11,12 13 14 Mainline F 9 M E S 100 21 20 A 1 9 = 90+% AFUE EFFICIENCY M = Multiposition POSITION E = Export TYPE S = 50 Hz FEATURE 100 = 100,000 BTU/hr 120 = 120,000 BTU/hr 140 = 140,000 BTU/hr HEAT INPUT 21 = 21 24 = 24 1/2 CABINET WIDTH 20 = 2000 CFM NOMINAL MAXIMUM COOLING AIRFLOW @.5 IN. W.C. SALES (MAJOR) REVISION DIGIT ENGINEERING (MINOR) REVISION DIGIT ACCESSORIES PART NUMBER IDENTIFICATION GUIDE DIGIT POSITION 1 2 3 4 5, 6, 7 8, 9 10, 11 N A H A 001 01 DH N = Non Branded BRANDING A = Accessory H = Heating A = Original B = 2nd Generation Product Identifier Number Package Quantity Type of Kit (Example: DH = Draft Hood Chimney Adapter) PRODUCT GROUP KIT USAGE MAJOR SERIES 2 440 21 4700 02

PHYSICAL DATA UNIT SIZE (NATURAL GAS Ratings) 1002120A 1202420A 1402420A Input Heat (BTUH) 100,000 120,000 140,000 Output Heat (BTUH) 97,000 117,000 135,000 Efficiency AFUE % (ICS) 93.0 Certified Temperature Rise Range ºF (ºC) 40 70(22 39) 45 75(25 42) ICS Isolated Combustion System AIRFLOW CAPACITY AND BLOWER DATA UNIT SIZE 1002120A 1202420A 1402420A Rated External Static Pressure in.w.c.(kpa) Airflow Delivery @ Rated ESP (CFM) Cooling Capacity (tons) @ 400, 350 CFM/ton Direct Drive Motor Type Heating 0.20(.050) 0.20(.050) 0.20(.050) Cooling.5 (.125) Heating 1680 2245 2175 Cooling 2065 2105 2035 400 CFM/ton 5 5 5 350 CFM/ton 6 6 6 PSC Permanent Split Capacitor Direct Drive Motor HP 1 1 1 Motor Full Load Amps 13.8 14.1 14.1 RPM Range 500 1150 Speed Selections 5 5 5 Blower Wheel Dia x Width (inches) 11 x 10 11 x 11 11 x 11 Air Filtration System Filter Used for Certified Watt Data CONTROLS External Field Supplied NAHA00706FB UNIT SIZE 1002120A 1202420A 1402420A Gas Connection Size 1/2 NPT Burners (Monoport) 5 6 7 Gas Valve (Redundant) Manufacturer White Rodgers Gas Conversion Kit Natural to Propane Gas Conversion Kit Propane to Natural Ignition Device Minimum Inlet Gas pressure in. w.c. (kpa) 4.5 (1.1) Maximum Inlet Gas pressure in. w.c. (kpa) 13.6 (3.4) NAHA01101LP NAHA01101NG Silicon Nitride Limit Control 180 160 155 Heating Blower Control (Heating Off Delay) Cooling Blower Control (Time Delay Relay) Thermostat Connections Accessory Connections Adjustable: 108, 144, 180, 216 seconds 108 seconds R, W, Y, G, C EAC (220vac); HUM (24vac) ELECTRICAL DATA UNIT SIZE 1002120A 1202420A 1402420A Input Voltage (Volts Hertz Phase) 220 50 1 Operating Voltage Range Min. Max. 198 242 Maximum Input Amps Amps 7.66 Unit Ampacity Amps 10.47 Minimum Wire Size AWG 14 Maximum Wire Length @ Min Wire Size Feet (M) 35(10.7) Maximum Fuse/Circuit Breaker (Time Delay Type Recommended) Amps 15 Transformer Capacity External Control Power Available Heating Cooling 24 VAC Output / 40 VA 27.9 VA 34.6 VA 440 21 4700 02 3

UNIT DIMENSIONS FURNACE SIZE 1002120 1202420 1402420 4 A CABINET WIDTH 21 (533) 24 1/2 (622) 24 1/2 (622) B OUTLET WIDTH 19 3/8 (492) 22 7/8 (581) 22 7/8 (581) C BOTTOM INLET WIDTH 19 1/2 (495) 23 (584) 23 (584) D AIR INTAKE 10 1/2 (267) 12 1/4 (311) 12 1/4 (311) SHIP WT. LB (KG) 173.5 (78.1) 191.0 (85.9) 195.0 (87.8) 440 21 4700 02

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS FOR ALL UNITS POSITION CLEARANCE In(mm) REAR 0 FRONT (Combustion air openings in furnace and in structure) 1 (25) Required for service *24 (610) All Sides of Supply Plenum *1 (25) Sides 0 Vent 0 Top of Furnace 1 (25) * Consult your local building codes. Table 1 COOLING AIR DELIVERY - CFM and L/s (with filter 1 ) AIRFLOW DELIVERY @ EXTERNAL STATIC PRESSURE (in. w.c.) UNIT SIZE 1002120 1202420 1402420 UNIT SIZE 1002120 1202420 1402420 RETURN-AIR- CONNECTION TWO-SIDES 3,4 TWO-SIDES 3,4 TWO-SIDES 3,4 RETURN-AIR- CONNECTION TWO-SIDES 3,4 TWO-SIDES 3,4 TWO-SIDES 3,4 COOLING 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 WIRE COLOR TONS CFM Black 5.0 2260 2215 2165 2115 2065 2010 1950 1890 1825 1750 Blue 5.0 2140 2100 2050 2005 1960 1915 1855 1800 1740 1680 Yellow 4.0 1815 1775 1735 1690 1645 1600 1545 1490 1420 1405 Orange 3.5 1665 1625 1575 1535 1495 1455 1410 1355 1300 1245 Red 3.5 1515 1475 1435 1390 1350 1310 1260 1210 1160 1110 Black 5.0 2215 2160 2105 2050 1990 1925 1855 1785 1720 1655 Blue 5.0 2070 2020 1975 1920 1860 1800 1735 1675 1615 1560 Yellow 4.0 1770 1725 1680 1630 1570 1520 1465 1420 1370 1315 Orange 3.5 1595 1550 1505 1455 1410 1365 1315 1270 1215 1170 Red 5 3.5 1460 1415 1365 1315 1270 1230 1180 1130 1075 1015 Black 5.0 2195 2145 2090 2035 1980 1915 1855 1795 1735 1675 Blue 5.0 2055 2005 1955 1905 1850 1795 1740 1685 1630 1575 Yellow 4.0 1755 1710 1660 1610 1565 1515 1465 1415 1365 1310 Orange 5 3.5 1590 1540 1495 1450 1400 1355 1310 1260 1205 1145 Red 5 3.5 1450 1400 1355 1310 1265 1220 1175 1120 1060 1015 AIRFLOW DELIVERY @ EXTERNAL STATIC PRESSURE (in. w.c.) COOLING 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 WIRE COLOR TONS L/s Black 5 1065 1045 1020 995 970 945 920 890 860 825 Blue 5 1005 990 965 945 925 900 875 845 820 790 Yellow 4 855 835 815 795 775 755 725 700 670 660 Orange 3.5 785 765 740 720 705 685 665 635 610 585 Red 3.5 715 695 675 655 635 615 590 570 545 520 Black 5 1045 1015 990 965 935 905 875 840 810 780 Blue 5 975 950 930 905 875 845 815 790 760 735 Yellow 4 835 810 790 765 740 715 690 670 645 620 Orange 3.5 750 730 710 685 665 640 620 595 570 550 Red 5 3.5 685 665 640 620 595 580 555 530 505 475 Black 5 1035 1010 985 960 930 900 875 845 815 790 Blue 5 965 945 920 895 870 845 820 795 765 740 Yellow 4 825 805 780 755 735 715 690 665 640 615 Orange 5 3.5 750 725 705 680 660 635 615 590 565 540 Red 5 3.5 680 660 635 615 595 575 550 525 500 475 NOTE: 1. A filter is required for each return air inlet. Airflow performance includes a 3/4 in. (19 mm) washable filter media such as contained in factory authorized accessory filter rack. See accessory list. To determine airflow performance without this filter, assume an additional 0.1 in. w.c. available external static pressure. 2. Blower speed taps are not always in the same order. Factory Default blower connections are as follows: Heating airflow BLUE (also used for Continuous Fan) Cooling airflow BLACK (enabled when the Y terminal is energized) ADJUST THE BLOWER SPEED TAPS AS NECESSARY FOR THE PROPER AIR TEMPERATURE RISE FOR EACH INSTALLATION. 3. Airflows over 1800 CFM require bottom return, two side return, or bottom and side return. A minimum filter size of 20 x 25 (508 x 635 mm) is required. 4. For upflow applications, air entering from one side into both the side of the furnace and a return air base counts as a side and bottom return. 5. Highlighted areas indicate that this airflow range is beyond the range allowed for heating. THESE AIRFLOW RANGES MAY ONLY BE USED FOR COOLING. 440 21 4700 02 5

ACCESSORIES PART NUMBER COMPONENT NAME DESCRIPTION 1002120 1202420 1402420 NAHA00101CT EXTERNAL TRAP KIT CONDENSATE TRAP NAHA00110DA DRAIN ACCESSORY 1/2 CPVC TO 3/4 PVC (10 PACK) NAHA00301CV 2 CONCENTRIC VENT X VENT TERMINATION KIT NAHA00401CV 3 CONCENTRIC VENT NAHA00301VT 2 BRACKET X DIRECT VENT TERMINATION KIT NAHA00401VT 3 BRACKET COUPLING FOR NAHA00101CK INLET AIR PIPE COUPLING POLYPROPYLENE VENT SYSTEMS NAHA00101HV HORIZONTAL INSTALLATION KIT TRAP GROMMET (DIRECT VENT APPLICATION ONLY) NAHA00101HH FREEZE PROTECT KIT CONDENSATE DRAIN LINE TAPE NAHA00201HH CONDENSATE FREEZE PROTECTION KIT CONDENSATE TRAP WITH HEAT PAD NAHA01101SB FLOOR BASE KIT COMBUSTIBLE FLOOR NAHA01101LP* NATURAL TO PROPANE GAS CONVERSION KIT NAHA01101NG* PROPANE TO NATURAL WASHABLE FILTER NAHA00706FB WASHABLE FILTER PACK 1 X 24 X 25 (6 PACK) NAHB00701FF NAHB00801FF NAHA01001FF EXTERNAL BOTTOM FILTER RACK SIDE FILTER RACK (NOT ADJUSTABLE) 21 X 25 WASHABLE FILTER INCLUDED 24 1/2 X 25 WASHABLE FILTER INCLUDED 16 X 25 RACK FILTER NOT INCLUDED X X X NAHA01006FF SIDE FILTER RACK PACK 16 X 25 RACKS (6 PACK) NAHB00101CA WITH NO OFFSET NAHB00201CA COIL ADAPTER KIT WITH SINGLE OFFSET NAHB00301CA WITH DOUBLE OFFSET NAHA02101RA RETURN AIR KIT 21 WIDE X NAHA02401RA RETURN AIR KIT 24 1/2 WIDE X X X Accessory available Suitable for side return filter rack and 17 inch external bottom filter rack. * Factory authorized and field installed. Gas conversion kits are CSA recognized. Part Number Gas Type Orifice Size Part Number Gas Type Orifice Size Part Number Gas Type Orifice Size 1185612 Natural 42 1183809 Natural 46 1184256 Propane 54 1176928 Natural 43 1185613 Natural 47 1185615 Propane 55 1185574 Natural 44 1185614 Natural 48 1185616 Propane 56 1177213 Natural 45 1185617 Propane 1.25 mm 1185618 Propane 1.30 mm Copyright 2014 International Comfort Products PO Box 128 Lewisburg, TN 37091 USA 6 440 21 4700 02