EVERY DAY IN FIRST CLASS

Similar documents
EVERY DAY IN FIRST CLASS

EVERY DAY IN FIRST CLASS

EXCELLENT BRANDING OPPORTUNITY WITH HIGHWAY 401 SIGNAGE BUILDING CLASS: FLOORS (#): 4 TOTAL SIZE: PARKING TYPE:

5580 EXPLORER DRIVE EXCELLENT BRANDING OPPORTUNITY WITH HIGHWAY 401 SIGNAGE MISSISSAUGA, ONTARIO AEROCENTRESOFFICES.COM

5 dock doors, 2 grade doors. Sprinklers throughout

$2,400,000. Fine Parts/Electronic Production Facility FOR SALE: FOR SALE 955 Green Valley Road, London ON

University Office Center - Phase I

BULLII I The Greenest Office Building in the World

Retail Box For Sublease

FENLEY OFFICE PARK B US Highway 42, Louisville, Kentucky

LEED GOLD Certified Office Building

FOR LEASE ROCKWOOD OFFICE PARK

TEN MILE & FRANKLIN LAND 39± ACRES 2954 WEST FRANKLIN ROAD MERIDIAN, ID

Auto Dealership off I-295

±12,800 SF TWO STORY BUILDING

3424 Chicago Drive Hudsonville, MI 49426

HORIZON PARK BUSINESS CENTER, Phase 2

FOR LEASE > CREEKSIDE

25 A&B Vreeland Road Florham Park, N.J.

Facility Condition Assessment Summary Report. British Columbia Institute of Technology NE6 - Plumbing and Pipefit Building

100 COMMERCE DRIVE CHRISTIANA CORPORATE CENTER NEWARK, DE

Self-Storage/Commercial Development Site

HOLUM EDUCATION CENTER. Architectural. January 13, 2014 DeForest Area School District

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

TECHNICAL SPECIFICATIONS ANZ TOWER

TECHNICAL SPECIFICATIONS 167 CASTLEREAGH STREET

Plot # R019A ± 74' ± 74' ± 65' Plot # R019A LEASE OUTLINE DRAWING GROSS LEASABLE AREA ± 4,631 S.F. DEMISING FRONT WIDTH DEPTH ± 13' ± 32' Lease Line

2233 Park Avenue. Property Features FOR LEASE > OFFICE 2233 PARK AVENUE, ORANGE PARK, FL ,200± SF AVAILABLE

2 Main Office Building BLDG-955A Building Purpose Building Area Administration offices. Training room 7,610 SF Inspection Date August 16, 2016 Inspect

FIRE/SMOKE BARRIER FUNDAMENTALS

Highly efficient space with close to 1,000 seats and over 100 meeting spaces. True plug-n-play with high-end FF&E

COVIDIEN SENECA, SOUTH CAROLINA

ARCHITECT S PRE-BID ADDENDUM

ELECTRICAL SYSTEMS ASSESSMENT Hanover High School

Request for Proposals (RFP) for: Columbia County Facilities Fire Detection and Security Improvements

THOROUGHLY THOUGHT THROUGH & THROUGH

INITIAL FIRE SAFETY ASSESSMENT

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

St Pauls Apartments. Residents Guidelines. Administrate (2009) Ltd L6, Dixon Street Te Aro Wellington. Ph:

Karrat Group City of Fountains City of Fountains Apartments City of Fountains

FIRE SAFETY INSPECTION REPORT

Fire Protection. A Health and Safety Guideline for Your Workplace. Introduction. Fire Prevention and Control. Workplace Assessment

Vacant Building Loss Prevention Best Practices

BLUEPRINT FOR PERIMETER, PHYSICAL SECURITY AND ACCESS CONTROL AT ELDO LAKES EXT. 5 & 6

ADVANCED 247 Link Walk, Eastfield, Scarborough, YO11 3LR. 24 Hour Line:

MEMORANDUM. I2 District Downtown Parking Overlay District 24,000 square feet /.55 acres. Industrial Employment District North Loop Small Area Plan

INITIAL FIRE SAFETY ASSESSMENT

PLAN REVIEW SUBMITTAL GUIDE

Paradise Marketplace. Unit # AOP +/- 1,600 SF +/- 12' +/- 11' +/- 8' 11'-7" +/- 85' +/- 74' +/- 20' MAIN FLOOR +/- 20' +/- 85' Width.

INTERNATIONAL BOULEVARD

INTERNATIONAL BOULEVARD

INITIAL FIRE SAFETY ASSESSMENT - EXPANSION

Building Self-Inspection Program

PLATTEVILLE MIDDLE SCHOOL

Paradise Marketplace REAR FRONT. Unit # AOH +/- 1,700 SF +/- 20' +/- 85' +/- 85' +/- 20' MAIN FLOOR +/- 20' +/- 85' Width. Depth

Construction Method, Material Selection, Fire Prevention & Building Security System For Project 9a : Board 4 ; For Project 9b : Part 4

HVAC / Boilers / Hot Water. Expected Life Span. very rough estimates Condition/Issue Age. Athletics / Gyms

Unit # 1038 ± 900 SF Width ± 15' Depth ± 60'

Motion Controlled Apartment Building Corridor Lighting

business park At the crossroads of innovation and industry.

FIRE SAFETY INSPECTION REPORT

FIRE SAFETY INSPECTION REPORT

TO: FROM: to help us. generates. e support.

NextGen Home Security. Quick Reference Guide

SCO # 1 & 2 PUNCLH LIST Project Name: VANCLEAVE UPPER ELEMENTARY CLA#: 13003

SERVICE REPORT REPORT SUMMARY OPTIONAL ITEMS. 1 P a g e TECHNICIAN: BOB WILDER SERVICE ADDRESS: 3047 N LINCOLN AVE SERVICE DATE: 12/2/2015

FIRE SAFETY INSPECTION REPORT

For Sale/Lease th Street North, St. Cloud, MN ,250,000. Mark A. Williams

Technical Report Two

FIRE SAFETY INSPECTION REPORT

INITIAL FIRE SAFETY ASSESSMENT

CHINO VALLEY INDEPENDENT FIRE DISTRICT FIRE PROTECTION STANDARD

Protégé Eclipse LED Keypad User Manual PRT-KLES

UBC Technical Guidelines Section Edition Interior Building Lighting Page 1 of 5

INITIAL FIRE ASSESSMENT REPORT (FAR)

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

LOCATION. By Taxi Taxis are readily available to and from 28 Hennessy Road. ACCESSIBILITY. Kowloon Tong

WHAT HAPPENS NEXT FOR ADT SMART BUSINESS CUSTOMERS

INITIAL FIRE SAFETY ASSESSMENT

State College Area School District High School South Building EXISTING CONDITIONS ASSESSMENT

Facility Explorer Asset Protection by Yorkland Controls Ltd. Fr

Unit # H ± 2,000 SF Width ± 25' Depth ± 80'

FIRE & SAFETY REGULATIONS (Updated )

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT

Emerald Lake Corporate Centre

CompleteView Alarm Client User Manual. CompleteView Version 4.6.1

Door/Window Sensor. Set-Up Guide

Paramount Property Mgmt & Realty LLC MOVE-IN / MOVE-OUT CONDITION CHECKLIST

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

Beaufort County Community College. Maintenance and House Keeping Plan

VIII - Advanced capabilities of KNX systems

Unit HH Gregg. ± 30,000 SF Width ±26' Lakeland Retail Center. Lease Outline Drawing. Unit HH Gregg. Depth ± 145' HVAC Units & Information

SMART Buildings: How sensor and information technologies are transforming the built environment

Emerald Lake Corporate Centre

INITIAL FIRE ASSESSMENT REPORT (FAR)

MOVE-IN / MOVE-OUT CONDITION

Ball Corporation 140,000 Square Feet on 27 Acres Birmingham, Alabama

Simplex Panel Interface Guide

INTERNATIONAL BOULEVARD

WHAT HAPPENS NEXT for ADT Interactive Security Customers

Transcription:

5560 EXPLORER DRIVE AEROCENTREOFFICES.COM EVERY DAY IN FIRST CLASS

EVERY DAY IN FIRST CLASS 5560 EXPLORER DRIVE SF AVAILABILTY ASKING RATE COMMENTS GROUND FLOOR SUITE 101 10,013 Immediate $17.50 Net Ground floor suite with double glass door entrance off main lobby. Ready for tenant improvements. ADDITIONAL RENT REALITY TAXES: $4.92 PSF OPERARING COSTS: $10.10 PSF TENANT HYDRO COSTS: $1.30 PSF ADDITIONAL RENT: $16.32 PSF (2018) Spend every day in first-class at Aero-Centre, an award-winning office community offering many on-site amenities. AeroCentre s prime location offers branding opportunities with exposure to Highway 401 in the prestigious Airport Corporate Centre. Easy access to Highways 401, 427 and 403 and minutes away for Pearson International Airport. Located within walking distance or short drive to numerous amenities and adjacent to Max Ward Park.

5560 EXPLORER DRIVE BUILDING SPECIFICATIONS Number of Floors: 4 Total SF: 98,111 SF Year Built/Refurb: 2000 Typical Floor Plate: Parking: 25,200 SF 3.2/1,000 SF EXTERIOR The exterior of the building consists primarily of double glazed blue vision glass and single glazed blue spandrel panels set on aluminum framed curtain wall assembly with precast decorative panels. The roof is an inverted roof membrane assembly. SUSTAINABILITY The building is BOMA BESt certified* and the recipient of the 2013 Race to Reduce Award. A risk management program run by RiskCheck Inc. provides Environmental, Health and Safety (EHS) Risk Management Service by correctly identifying, managing, and monitoring risks, and helping to establish the procedures to eliminate or control hazards. Monthly reports in addition to annual inspections provide updates on the status of current levels of statutory compliance plus a general summary of current and planned initiatives. TELECOMMUNICATIONS The building is equipped with Bell and Rogers communications fibre optics. *Under re-certification

SECURITY After-hours access to the building is provided through pass cards and they are programmed for limited access to the building. There are three CCTV cameras, one located at each entrance of the building and one exterior camera facing the driveway, all backed up into a digital video recorder. MECHANICAL Nine gas fired rooftop air handling units provide heating and cooling throughout the building. The on floor temperature is controlled and distributed by variable temperature, variable volume air distribution boxes (VVT). These in turn are controlled by the Johnson Controls Metasys BAS complete with night set back controls for energy efficiency. Supplemental heating is provided by electric heaters located at the perimeter walls of the building. All washrooms are equipped with water efficient and hands-free faucets, soap dispensers and urinals. LIGHTING The building standard lighting is T8 and electronic ballast technology, LED lamps in lobby and LED exit lights. Interior lights are managed by a computerized lighting control system. Override switches allow tenants to turn lights on in various work areas should they require additional lighting outside of regular business hours. These fixtures will automatically turn off after the override has been activated within two hours for added energy conservation. All washroom lights are on motion sensors for energy conservation. ELECTRICAL The electrical power supply is provided from a transformer located on the ground floor in the electrical room providing 1200 amps and 347/600 volts of power. EMERGENCY GENERATOR/BACK UP POWER In the event of a power failure, emergency lighting will illuminate for a span of 30 minutes. The management office located in 5580 Explorer is set up with emergency generator power to allow the management team to maintain consistency and operations in the event of a power failure. FIRE LIFE SAFETY SYSTEMS The building is equipped with sprinklers and a standpipe system. There are typically two fire hose cabinets, with extinguishers, per floor. The Simplex fire alarm panel controls detection points throughout the building and is monitored 24/7. Smoke and heat detectors and pull stations are located throughout the building. ELEVATORS Three hydraulic elevators provide speed and convenience to all floors and include hands free communication to the emergency monitoring station. TENANT SERVICES Menkes uses Angus AnyWhere Tenant Service Request. This is a fully web enabled service management solution specifically designed for commercial real estate. Detailed service requests are submitted by tenants through the Menkes website and sent to the appropriate party for action. The real-time application interacts with handheld wireless messaging device to speed service delivery and ensure prompt service action. The management team reviews reports regularly to monitor the types and frequency of various service request.

5560 EXPLORER DRIVE SUITE 101 RENTABLE AREA = 10,013 SF ABOVE INFORMATION ESTABLISHED ACCORDING TO BOMA / ANSI Z65.1 1996 SUITE 102

AEROCENTREOFFICES.COM EVERY DAY IN FIRST CLASS CONTACT US: Domenic Galati* Senior Vice President +1 416 620 2834 domenic.galati@colliers.com Ron Jasinski* Senior Vice President +1 416 620 2801 ron.jasinksi@colliers.com Colliers International Toronto West 401 The West Mall, Suite 800 Toronto, ON M9C 5J5 +1 416 777 2200 www.collierscanada.com This document/email has been prepared by Colliers International for advertising and general information only. Colliers International makes no guarantees, representations or warranties of any kind, expressed or implied, regarding the information including, but not limited to, warranties of content, accuracy and reliability. Any interested party should undertake their own inquiries as to the accuracy of the information. Colliers International excludes unequivocally all inferred or implied terms, conditions and warranties arising out of this document and excludes all liability for loss and damages arising there from. This publication is the copyrighted property of Colliers International and /or its licensor(s). 2018. All rights reserved. This communication is not intended to cause or induce breach of an existing listing agreement. Colliers Macaulay Nicolls Inc. (Toronto)