Illumination unit For sight glass level indicator Model LGI

Similar documents
Gas cylinder scale Model GCS-1

Indoor/outdoor resistance thermometer Model TR60

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

DTS Light fittings for explosive atmospheres

Ex LED light fittings

High bay LED lighting fixture

CCA-03EX. - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22. Directional LED spotlights

60W Flameproof LED Emergency Linear Fixture V AC - (2) 30W LED Lamps - ATEX/IECEx

XLFE-4/1. Borosilicate glass globe

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

Dräger Polytron 5700 IR Detection of flammable gases and vapours

BC9700 series High Power LED Explosion Proof Light

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Universal controller for panel mounting Models CS6S, CS6H, CS6L

Fan Heaters Type VLEx

Micro and Mini Torch. Zones: 0, 1, 2, 20, 21 and 22. Product Overview. Features & Benefits. Certifications

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

Dräger Polytron 8000 Stationary gas detector (EC)

EWL. Supporting bracket

USER GUIDE EXPLOSION-PROOF TELEPHONES ATEX GASES AND DUSTS TYPE 227A1 IM2 FOR GROUP I MINING II 2GD FOR GROUP IIC AND IIIC GASES AND DUSTS

Dräger Polytron 8310 Stationary gas detector (DSIR)

Flameproof Manual Call Points Series MCP

EN54-5, ATEX and IECEx approved Highly durable Automatic reset after cooling Range of alarm temperatures

Dräger Polytron 8310 IR Detection of flammable gases and vapour

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.

ExPolar Heating System

TYPE APPROVAL CERTIFICATE

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE

TBSF/CBSF Stainless Steel Flat Roof Screwed Terminal Box Zones 1&2, 21&22

Dräger Polytron 8700 IR Detection of flammable gases and vapors

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

HDL106 LED LUMINAIRES. For Harsh & Hazardous Environments.

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

SPARTAN SPX-HPBY LED Zone 1 Bay Light - IIB Applications

INTRINSICALLY SAFE LIGHTING RANGE

Integrated Solutions Low Voltage Systems

Manual Power relay SR853

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 5720 IR Toxic Gas Detection

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

Magnetostrictive sensor For bypass level indicators Model BLM

SafeSite LED Area Light - IECEx / ATEX for Indoor and Outdoor Hazardous Areas. Patent Pending

manual addendum DELPHI Ex

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger Polytron 8700 IR Detection of flammable gases and vapors

40W Explosion Proof LED Light Fixture - C1D1, C2D1-2x2 Lay-in Troffer - ATEX/ISO Rated

EXPLOSIONPROOF LED LIGHT FITTINGS TO USE IN ZONES 1,21 & 2,22 KDB 15ATEX0049X NEW

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Phoenix Explosion-proof. Pan & Tilt heads and Camera Housings for potentially exposed environments. Answers for infrastructure.

Multiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55

Explosion-proof Immersion Heater Type D-8660

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 8200 Stationary gas detector (CatEx)

Limit Switch Box YT-870/875 SERIES

Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

ATEX. Wolf Safety Lamp Company. Includes NEW LinkEx LED. The widest range of portable ATEX lighting approved for use in explosive atmospheres

Dräger Flame 2700 (Multi-IR) Flame Detection

DICTATOR Hold-Open Systems for Hazardous Areas

Electrical Installations Design, Selection, Erection and Inspection

Dräger Flame 2500 (IR3) Flame Detection

NexLED. Ex e LED BULKHEAD. Features. Standard Specification. International Approvals. NexLED with Exit Sign kit

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Dräger Polytron 5720 IR Detection of carbon dioxide

Dräger Polytron 8100 EC Detection of toxic gases and vapors

ELECTRICAL EX EQUIPMENT

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

SOLUZIONI PER ATMOSFERA ESPLOSIVA

User s Manual. AXF Series Magnetic Flowmeter Installation Manual ATEX and IECEx Explosion Proof Type IM 01E20A01-11EN IM 01E20A01-11EN.

Dräger Flame 2350 (UV&IR) Flame Detection

Hazardous Area Portable Fan Heater The Bulldog

Stego accessories for cabinets

Explosion Proof Manual Call Points Series MCP

Dräger Flame 2100 (UV) Flame Detection

ATEX. Wolf Safety Lamp Company. The widest range of portable ATEX lighting approved for use in explosive atmospheres

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

Operating Instructions

Hazardous Area Portable Fan Heater The Bulldog

Performance Data. curus Component Recognized; File No. E IP 20

distributed by Sole Agent in Great China Universky (Jiangsu) Technologies, Inc. Phone: Fax:

Dräger Flame 2370 (UV&IR) Flame Detection

DB4 Range - SPEAKERS - Up to 25 Watts

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH

TECHNICAL MANUAL EXPLOSION PROOF STATUS LIGHT / LAMP BSL 125 / BSL 150. Scope: EXcite USER MANUAL BSL 125 / BSL 150. Date:

Certification Supplement Manual

Industrial Cast-in Circulation Heaters for ATEX/IECEx hazardous areas or in non-atex version

Guide for hazardous areas

GUB. Ex d. Screw-on lid. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 8 sizes - IP66. Polyester coating. Cast mounting feet

Transcription:

Level Illumination unit For sight glass level indicator Model LGI WIKA data sheet LM 33.02 for further approvals see page 2 Applications Better identification of liquid and gaseous phase Direct indication of the level Chemical industry, petrochemical industry, oil and natural gas extraction (on- and offshore), shipbuilding, machine building, power generating equipment, power plants Special features Simple mounting of the illumination system Illumination types available for different applications Operating temperature: depending on illumination method Matching to the respective length of the glass indicator Illumination unit with LED light source, model LGI-L Description An illumination unit model LGI can be used for transparent or refraction indicators. It improves the identification of the transition from the liquid to the gaseous phase. There are various systems available, which can be matched to the respective application. Depending on the version, LEDs, a halogen bulb or sodium vapour lamp can be used as a light source. Page 1 of 6

Model overview Model Description Temperature range LGI-L Illumination unit with LED light source -40 +85 C LGI-HD Illumination unit with halogen bulb, Ex d -20... +60 C LGI-LD Illumination unit with LED light source, Ex d -20... +60 C LGI-N Illumination unit with sodium vapour lamp -20... +150 C LGI-LE Illumination unit with LED light source, Ex e -25... +60 C Approvals Model LGI-L Model LGI-N Low voltage directive Models LGI-HD, LGI-LD Low voltage directive ATEX directive Hazardous areas II 2GD Ex db IIC T6... T3 Gb II 2GD Ex tb IIIC T54 C... T185 C Db IP66 IECEx (option) Hazardous areas Ex db IIC T6... T3 Gb Ex tb IIIC T54 C... T185 C Db IP66 Model LGI-LE Low voltage directive ATEX directive Hazardous areas II 2G Ex eb mb op is IIC T4 Gb II 2D Ex tb IIIC T130 C Db Approvals and certificates, see website Page 2 of 6

Illumination unit with LED light source For sight glass level indicator (transparent indicator) Model LGI-L 17,5 306 120,15 80 Specifications Light source used LumiFlex Economy 35 Electrical power Current Case material Electrical connection Dimensions of illumination DC 24 V 4.8 W/m 200 ma/m to 1,600 mm Aluminium 40,000 h M12 connector (male) Ambient temperature -40... +85 C Accessories (optional) 35 mm 120 mm IP66 -dependent Connection cable Page 3 of 6

Illumination unit with halogen bulb or LED light source For sight glass level indicator (transparent indicator) Models LGI-HD, LGI-LD (7) II 2GD Ex db IIC T6... T3 Gb / II 2GD Ex tb IIIC T54 C... T185 C Db IP66 (7) (approx. 190) (approx. 293) 60 (approx. 190) 60 (approx. 293) Ø 150 36 Ø 150 36 (approx. 171) (approx. 171) Specifications Halogen bulb LED light source Light source used OSRAM Halogen Classic A Eco 30... 77 W 1) Cortem LampLED 8 W Frequency AC 230 V 50... 60 Hz Electrical power 30... 77 W 1) 8 W Case material Stainless steel 1.4301 Electrical connection Dimensions of light control box 2,000 h Ambient temperature -20... +60 C Cable entry ¾ NPT female (adapter and cable gland optional) 58 mm 180... 300 mm 1) IP66 -dependent 1) Depending on the version Page 4 of 6

Illumination unit with sodium vapour lamp For sight glass level indicators (refraction indicator) Model LGI-N (approx. 171) 36 120 Specifications Light source used Philips BY22d 18/9 TV-SOX-E 35... 55 W 1) AC 230 V Electrical power of the lamp 35... 55 W 1) Current Case material Stainless steel 1.4301 (304) 16 A 6,000 h Electrical connection Cable gland M20 x 1.5 Dimensions of control cabinet Height Dimensions of light 380 mm 380 mm 210 mm 60 mm 60 mm Ambient temperature (light) -20... +150 C Light Control cabinet IP65 approx. 3 kg approx. 15 kg 1) Depending on the version Page 5 of 6

Illumination unit with LED light source For sight glass level indicators (transparent indicator) Model LGI-LE II 2G Ex eb mb op is IIC T4 Gb / II 2D Ex tb IIIC T130 C Db 10 25 A A B B C Specifications Light source used Frequency Electrical power Case material Dimensions LED light source TNCLS backlight AC 220... 240 V AC 254 V 50... 60 Hz approx. 4 W/m Stainless steel 1.4404 (316L) 60,000 h Ambient temperature -20... +70 C 100 mm 128 mm IP66 7.3 kg/m Ordering information Model / Light source / Ambient temperature min./max. / Visible length / Sight glass level indicator present (serial number, order confirmation number) / Approvals / Options 02/2019 WIKA Alexander Wiegand SE & Co. KG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. 02/2019 EN Page 6 of 6 WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg/Germany Tel. +49 9372 132-0 Fax +49 9372 132-406 info@wika.de www.wika.de