GAS DETECTOR ST400EC PART.NO

Similar documents
Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

OLC(T) 100 FIXED GAS DETECTOR

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

3M Oldham OLCT 100. Description. Fixed Gas Detector

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

Xgard. Fixed detectors For flammable, toxic or oxygen gases

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

Sieger Apex. Flexibility that meets your requirements

EC24. Operation Manual. (Type MWG 2411, MWG 2412, MWG 2413 and MWG 2414)

Micro III (Models G203, G203S, and G213) Operation Manual

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

Transmitters/Sensors. OLCT Series

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Model D12. Digital Gas Transmitter

Satellite XT. Analogue or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

FREEDOM SERIES 5000 AND 5600 GAS TRANSMITTERS

Satellite XT. Analog or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

Toxic Gas Detection. Model F12. Toxic Gas Detection

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

MICRO III (G202 / G202s / G212) Single Gas Detector

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

Monitores Personales. Personal Monitor

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

MICRO IV. Operation Manual. Single Gas Detector

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

UniSens 2-Wire Gas Transmitter

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

Frequently Asked Questions

Single Gas Detector. Long-term solution H 2 S O 2 SO 2 NH 3 PH 3. Cl 2. ClO 2 NO 2 HCN ETO O 3

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

UniSens. 2-Wire Gas Transmitter. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

Stand Alone DYNAGARD SP Operation Manual

Micro IV Operation Manual

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

GMA 36 Pro. Operation Manual. Stand Alone Monitor

GMA 36 Pro. Operation Manual. Stand Alone Monitor

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

MICRO IV. Installation & Maintenance Instructions. (G221 / G222 / G223) Single Gas Detector

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety

Fixed Gas & Flame Detection International Product Range Overview

Dräger Polytron 5700 IR Detection of flammable gases and vapours

SYSTEMS LTD. Model «FDG3» LEADERS IN PROCESS ANALYSIS AND CONTROL

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

ALTAIR 5X Multigas Detector Product Specification

IGD.CO.UK

Dräger Polytron 5100 EC Detection of toxic gases and vapors

TOCSIN 750 SERIES SAFE AREA GAS DETECTORS. 2-Wire Addressable Systems. 2 Core Cable Unscreened. 6 Standard 20mm Gland Entry Knockouts

ESD500. ESD500 Combustible / Toxic Gas Detector

TOXIC GAS AND OXYGEN DETECTOR DTX 420 INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS DTX420_MAN01_EN_V1R2

APPLICATION DATA SHEET

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

Sensepoint. The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs.

Zareba Sensepoint Pro

Micro IV. Single Gas Detector. Operations Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

P R O D U C T D ATA S H E E T

ESD3000 ESD200 Combustible / Toxic Gas Detector

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Series 3000 XPIS. 2-wire loop powered toxic and Oxygen gas detector for use in potentially explosive atmospheres

Toxic Smarter Transmitter Instruction Manual

Instructions TXL Series Oxygen and Toxic Gas Detectors 4/

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

SP-220. Features. Combustible handheld gas leakage detector

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Two-Channel Gas Controller

MDA Scientific Midas. Gas monitoring system for fast and reliable detection of flammable and toxic gases used in industrial manufacturing processes

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

Polytron 2. The smart gas detector

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]

Signalpoint. The Signalpoint range of flammable, toxic and Oxygen gas detectors offer users a low cost solution to their indoor gas monitoring needs

Midas. Gas monitoring system for fast and reliable detection of flammable and toxic gases used in industrial manufacturing processes

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

CH 4 C 2 H 2 C 3 H 8 CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2

Warranty Registration

Dräger Polytron (approved as type P3S) Transmitter for electrochemical Sensors. Instructions for Use. ST eps

Dräger Polytron 8000 Stationary gas detector (EC)

Gas Detection For Life

G-TECTA TM. Portable Gas Detection Instruments

Dräger Polytron 5100 EC Detection of toxic gases and vapors

OLCT 10N. Digital Gas Detector. User Manual. The Fixed Gas Detection Experts. Part Number: NPO10NEN Version: G.1

Carbon Monoxide CO Transmitter ADT-X3-1110

ALTAIR 5X Multigas Detector

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

THE BELGIAN PIONEER IN GAS DETECTION

The Dräger X-am 1700/2000 are a new generation of personal gas detectors.

SENSOR O2 O2-A

Dräger Polytron 8700 IR Detection of flammable gases and vapors

ExDetector HC-100. Data Sheet. Gas Measuring and Alarm Systems

Transcription:

DATA SHEET 1(7) GAS DETECTOR ST400EC PART.NO. 004461-004467 DETECTION OF TOXIC GASES AND OXYGEN SYSTEM GS5000, GS3000, SW2020, BUCONTROL / BUTOUCH GENERAL DESCRIPTION Detection of toxic gases and Oxygen ATEX certified, suitable for zone 0 One man calibration 4-20 ma output Reliable sensor technology The ST400EC, is a gas detector for the detection of Oxygen, Toxic gases or Hydrogen. De ST400EC is assembled with a chromed plated ABS housing with a transmitter board, replaceable electrochemical sensor, Stainless steel sensor holder and EMC cable gland. The transmitter is based on the one man calibration principle, this means that calibration take place at the detector head directly. The sensor is a replaceable electrochemical sensor. Operation of the sensor depends upon the changes of the electrical parameters of electrodes, in contact with an electrolyte, due to reaction of the gas on the surface of the electrodes. The chemical reaction in the sensor produces a current output signal. The obtained signal, proportional with the gas concentration, will be converted in a linear output signal, 4-20 ma, 2 wire. APPLICATIONS: Refrigeration Soil remediation Water Industry Food Industry Laboraty / Universities Storage of dangerous goods Chemical industry WE OFFER MORE THAN A PRODUCT! Tailored advice Project advice Technical support Training and education Commissioning Onsite service / maintenance / calibration Explosion proof, this sensor / transmitter is intrinsically safe in combination with the specified external isolator, according ATEX Ex ia IIC T5 G and can be used in an Ex zone 0.

DATA SHEET ST400 2(7) ORDERING INFORMATION GAS DETECTOR TYPE RANGE PART NO. OPERATING TEMPERATURE RELATIVE HUMIDITY (N.C.) ST400-AsH 3 0-500 ppb 1217518-20 tot +40 0 C 10-95% ST400-Br 2 * 0-1 ppm 1217529-20 tot +40 0 C 15-90% ST400-Cl 2 0-5 ppm 1217507-20 tot +40 0 C 15-90% ST400-Cl 2 0-50 ppm 1217530-20 tot +40 0 C 15-90% ST400EC-CO * 0-250 ppm 004463-40 tot +50 0 C 15-90% ST400-COCl 2 0-1 ppm 1217509-20 tot +40 0 C 15-90% ST400-ClO 2 0-1 ppm 1217525-20 tot +40 0 C 15-90% ST400-ETOX 0-20 ppm 1217523-20 tot +50 0 C 15-90% ST400-F 2 0-1 ppm 1217516-10 tot +40 0 C 15-90% * 0-1000 ppm 1217513-20 tot +40 0 C 15-90% (LEL) * 0-100 %LEL 1217521-20 tot +40 0 C 15-95% S (G) * 0-30 ppm 1217506-20 tot +40 0 C 10-90% S (L) * 0-30 ppm 004462-20 tot +40 0 C 15-90% ST400-HCl 0-30 ppm 1217517-20 tot +40 0 C 15-95% ST400-HF 0-10 ppm 1217512-20 tot +40 0 C 15-90% ST400-HCN * 0-30 ppm 1217508-40 tot +40 0 C 15-90% ST400-N 2 H 4 * 0-1 ppm 1217515-10 tot +40 0 C 20-95% ST400-NH 3 0-100 ppm 004464-20 tot +40 0 C 15-95% ST400-NH 3 0-1000 ppm 1217526-20 tot +40 0 C 15-90% ST400-NO 0-100 ppm 1217514-15 tot +40 0 C 20-90% ST400 NO 2 * 0-20 ppm 1217504-20 tot +50 0 C 15-90% ST400-O 2 * 0-25 Vol.% 004461-30 tot +55 0 C 5-95% ST400-O 3 * 0-1 ppm 1217510-20 tot +40 0 C 15-90% ST400-SiH 4 0-50 ppm 1217519-20 tot +40 0 C 15-95% ST400-SO 2 * 0-20 ppm 1217505-20 tot +50 0 C 15-90% ST400-TBM * 0-50 mg/m 3 (0-14 ppm) 004467-10 tot +40 0 C 10-95% *ATEX certified

DATA SHEET ST400 3(7) SPARE PARTS / CONSUMABLES SPARE GAS SENSOR PART NO. RANGE DESCRIPTION Type AsH 3 1217618 0-500 ppb Arsine sensor Type Br 2 1217635 0-1 ppm Bromine sensor Type Cl 2 1217635 0-5 ppm Chlorine sensor Type Cl 2 1217635 0-50 ppm Chlorine sensor Type CO 1217602 0-250 ppm Carbon monoxide sensor Type COCl 2 1217609 0-1 ppm Phosgene sensor Type ClO 2 1217626 0-1 ppm Chlorine Dioxide sensor Type ETOX 1217623 0-20 ppm Ethylene oxide sensor Type F 2 1217616 0-1 ppm Fluor sensor ppm 1217613 0-1000 ppm Hydrogen (ppm) sensor LEL 1217621 0-100 %LEL Hydrogen (LEL) sensor S (G) 1217606 0-30 ppm Hydrogen sulfde (G) sensor S (L) 1217622 0-30 ppm Hydrogen sulfide (L) sensor Type HCl 1217617 0-30 ppm Hydrogen chloride sensor Type HF 1217612 0-10 ppm Type Hydrogen fluoride sensor Type HCN 1217608 0-30 ppm Hydrogen Cyanide sensor Type N 2 H 4 1217615 0-1 ppm Hydrazine sensor Type NH 3 1217603 0-100 ppm Ammonia sensor Type NH 3 1217628 0-1000 ppm Ammona sensor Type NO 1217614 0-100 ppm Nitrogen Oxide sensor Type NO 2 1217604 0-20 ppm Nitrogen dioxide sensor Oxygen O 2 1217627 0-25 Vol.% Oxygen sensor Type Ozone O 3 1217624 0-1 ppm Ozone sensor Type SiH 4 1217619 0-50 ppm Silane sensor Type SO 2 1217605 0-20 ppm Sulphur dioxide sensor Type TBM 1217625 0-50 mg/m3 (0-14 ppm) TBM sensor

DATA SHEET ST400 4(7) ACCESSORIES TYPE IMAGE PART NO. DESCRIPTION Isolator barrier for EX applications 1217576 Isolator barrier for use in combination with the explosion-proof gas sensor / transmitter ST400 with an EEx application Signal cable 5150223-00A 2 core shielded cable, 2x0,75 mm 2 (flexible cores, 3+PE), per meter Duct mounting set 5150229-00A Duct mounting set for mounting in ventilation ducts Splash guard 4002716 Iinvironmental sensor protection, incl. splash water Inline flow adapter 5150228-00A Inline flow adapter for sample applications, connection 2x6mm, SS Protective hood 5150226-00A Protective hood SS, for optimal protection in wet production areas, dim. 315x300x138 mm Isolation set EMC/RFI 5150231-00A Isolation plate EMC/RFI, 160x160 mm Protective bracket 5150225-00A SS bracket, extra protection for use in e.g. warehouses Conical collector hood 5150230-00A Conical hood for ascending gases

DATA SHEET ST400 5(7) CONNECTION DIAGRAM GAS DETECTOR ST400 - non-ex zone GAS DETECTOR + +24 Vdc - Signal CONTROL UNIT ST400 with isolator - Ex zone Ex Non Ex ISOLATOR 11 0 Vdc GAS DETECTOR + 2 12 Signal - 1 13 0 Vdc CONTROL UNIT 14 +24 Vdc

DATA SHEET ST400 6(7) DIMENSIONS

DATA SHEET ST400 7(7) SPECIFICATIONS PRODUCT Gas type Sensor type Range Power supply Outpt Signal cable Cable gland Operating temperature Relative humidity Pressure range Enclosure Dimensions Weight Ingress Protection ST400EC Electrochemical sensor (2 or 3 electrodes) 12-30 VDC (max. 0,75 Watt) Analog: 4-20mA 2-wire shielded, 0.75 2.5 mm 2 (excluding earth connection) Brass-nickel plated, EMC type Toxic: Atmospheric ± 10%, Oxygen: 80 to 120 kpa Metallized ABS 145 x 175 x 55 mm (LxBxD) 0,5 kg IP 65 (excl. sensor) Enclosure gas sensor SS 316 CE marking Approvals Manufacturer ATEX (Directive 2014/34/EU) Electromagnetic Compatibility (Directive 2014/30/EU) II 1 G Ex ia IIC T5 Ga Tamb -40 0 C tot +60 0 C BUVECO Gasdetection BV, a Consilium Group Company