Technical Data Ducted Three Phase Split System Air Conditioner

Similar documents
Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

Technical Data OPA 294, 340, 370. Ducted Three Phase Packaged Air Conditioners kw 34.0 kw 39.1 kw. Twin System Enables Staging

Technical Data ISU Series. Underceiling/Console Split System Air Conditioners kw 15 kw

Technical Data ISD 184KY / OSA 184RKTV. Ducted Split System Air Conditioner kw

Technical Data ISD 87KYX / OSA 87RKSH. Ducted Split System Air Conditioner. 8.5 kw

Technical Data OPA RKTBG-P. Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

Ducted Split System Air Conditioners Technical Data

Ducted Split System Air Conditioners Technical Data

Technical Data VPA 120, 160. Ducted Vertical Packaged Air Conditioner/Heat Pump kw 16.1 kw. Wide Ambient Capabilities

MEPS COMPLIANT. Product Review OPA-RK Series. Ducted Packaged Roof Top Air Conditioners kw 137 kw. Extra Long Life Epoxy Coated Outdoor Coil

Water Cooled Units HWP 370, 445. Cooling Capacity 36.6kW kW. Heating Capacity 34.9kW kW

Technical Data ACN Series. Modular Air Cooled Condensers. 68 kw 155 kw. Extra Long Life Epoxy Coated Outdoor Coil. Nominal Cooling Capacity

EC Motor Fan Coil Units. IMD-Y Series l/s

Packaged Air Conditioning Custom Build Solutions

EC Motor Fan Coil Units. IMDL-Y Series l/s

Cooling Capacity 3.5kW kW. Heating Capacity 4.4kW kW. Air Conditioning. Giving you complete control

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Commercial High-Efficiency Condensing Units

MACH N-407 Heat Pump Air-Cooled Chiller

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

MAC N-407 Air-Cooled Chiller

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

ROOFTOP PACKAGED AIR CONDITIONERS

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

OPA RKTG-P (ECO) Air Cooled Packaged Units - Reverse Cycle - R410A Installation & Maintenance

S Y D. HWP 35, 47, 58 (c/w EC Motor & UC7 Controller) Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

OPTIONAL SPRING MTG HANGING CENTRES WATER CONN'S: TWO BSP MALE. 19 mm (3/4") ELECTRICAL CONDUIT HOLES ACCESS PANEL OUT (WATER) IN 485 MOUNTING

PAJ3. Product Specifications

S D HWP 77, 96. Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance. Fig. 1 Nomenclature. Fig.

Condensing Units CUS 15-60

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

PRODUCT RANGE: ROOFTOP PACKAGE

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

MAC-120HE-03 Air-Cooled Chiller

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

Remote Air Cooled Condensers C2 Series

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

R4H4. Product Specifications

T P A 120 S 4 S N 1 Y

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS

PACKAGE AIR CONDITIONER

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

R407C Cellar Cooling. Fansets: Single phase, high efficiency, low

ADD-ON AIR CONDITIONING CHANGING THE GAME FOR COMFORT AND PERFORMANCE

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

GUIDE SPECIFICATIONS AQUARIUS ii

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

Cooling Capacity 3.5kW kW. Heating Capacity 4.4kW kW. eco. series. Air Conditioning. Giving you complete control

ICC COOLING STORAGE UNIT ICC/ICU SYSTEM

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Commercial High-Efficiency Condensing Units

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

High temperature air-to-water heat pumps

500 EX Fusion Compressor Series

R4H4. Product Specifications

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts

Your Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

Kirby Commander Condensing Unit

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

PUHZ-SHW140YHA PUHZ-SHW230YKA

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

G34M Bulletin #69/ August 2003

next DX.U.S* 052.Z2.H6.DC

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

Modular Air Cooled Scroll Chillers

Application guide Installation, operating and maintenance manual AIRCUBE - KSCM/KSHM. Providing indoor climate comfort

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Cooling Capacity 1.0kW - 8.5kW. Heating Capacity 1.0kW - 9.7kW. Hitachi. Inverter Wall Splits Air Conditioning. Giving you complete control

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

Transcription:

ENERGY EFFICIENT ISD / OSA 2 Technical Data Ducted Three Phase Split System Air Conditioner EXTRA LONG LIFE EPOXY COATED OUTDOOR COIL Nominal Cooling Capacity 26.5 kw (Total) JUNE 4

ISD / OSA 2 DUCTED THREE PHASE SPLIT SYSTEM AIR CONDITIONER GENERAL ISD 85Q, ISD 127Q, ISD 181Q, ISD 2Q - Indoor units usable for reverse cycle or cooling only OSA 2 - A general designation for outdoor unit OSA 2C - Outdoor unit, cooling only version OSA 2R - Outdoor unit, reverse cycle version The ISD indoor unit, together with its associated OSA outdoor unit, provides a three phase split system air conditioner designed and developed to comply with and exceed AS/NZS 3823 specified conditions (i.e. guaranteed cooling cycle performance at 43 C outdoor temperature). APPLICATIONS These units have been specifically developed for air conditioning of commercial and residential premises, e.g. offices, motels, homes, apartments, shops and restaurants. Distributing Capacity The outdoor unit can be matched to its own dedicated indoor unit. Alternatively, two split capacity indoor units can be coupled to the single compressor outdoor unit and controlled from one room thermostat. This tandem arrangement is often quieter than a larger single unit and permits air distribution closer to where it's needed most. The Indoor Unit options are: 1. One ISD 2Q (26.5 kw), 2. Two ISD 127Q (12.5 kw x 2 ), or 3. One ISD 85Q (8.5 kw) and one ISD 181Q (18.1 kw). Air Flow Selection The nominal indoor air flow and temperature /humidity conditions meet AS/NZS 3823 rating standards (incl. 5%RH). Consideration must always be given to selecting an air flow and face velocity that avoids water carry-over problems. High humidity levels can occur in tropical or subtropical conditions, and/or when heavily moisture laden fresh air is introduced. If the air returning to the indoor coil is regularly expected to be above 5%RH, then the coil face velocity should be limited to be 2.5 m/s or less (refer Air Flow graph; 2.5 m/s is clearly marked). Applications using full or high proportions of fresh air should be referred to your nearest temperzone sales office to establish the correct selection of units. FEATURES Efficient. The outdoor unit has a high efficiency scroll compressor. Heat exchange coils incorporate inner grooved (rifled) tube for better heat transfer. Performance. A dynamically balanced forward curved fan with a multi-speed motor enables fine tuning of the indoor unit to match the supply air requirements. The system includes a temperature sensing head pressure control which enables the system to run efficiently on cooling cycle at outdoor ambient temperatures below C, and heating cycle above C. Quiet. The compressor is isolated in a builtin, insulated compartment to minimise noise. The indoor unit is also insulated for noise attenuation. Slimline. The compact upright design of the outdoor unit requires only a mm gap on the coil side where installation is against a wall. Its slimline cabinet is particularly practical where there is restricted space, e.g. side access pathways, balconies, narrow ledges, etc.. Durable. The outdoor coil fins are epoxy coated for extra protection in corrosive environments, e.g. salt laden sea air. The outdoor unit's cabinet is constructed from high grade galvanised steel polyester powder coated for all weather protection (IP 45). External fasteners are stainless steel. Heat exchange coils comprise aluminium plate fins on mechanically expanded rifled copper tube. The indoor unit's cabinet is constructed from high grade galvanised steel and includes a plastic drain tray for complete corrosion resistance. Service Access. The indoor unit's built-in drain tray can be removed for ease of cleaning and service accessibility. Insulation. Closed cell foam insulation has been used in the indoor unit's cabinet to ensure no particles are introduced into the air stream. The insulation is foil faced and meets fire test standards AS 3.3 (1989) and BS 476 parts 6 & 7. Mounting. The indoor unit can be mounted rigid, or using the optional spring mounting brackets which minimise transfer of vibration. Self Diagnostics. The Outdoor Unit Controller (OUC) has a display of LEDs to indicate faults and running conditions. A general fault indicator is included for interface to external systems. ORIES Outdoor Unit: 1. LP switch. 2. Fault indicating auxillary relay board. Indoor Unit: 1. Filter box - integrated return air spigot and washable filter (rated EU2). 2. temperzone TTS-1 Wall Thermostat kit 3. Spring Mounting Kit. 4. Electric booster heater box - complete with safety cutouts required to meet AS/NZS 335.2.4 1997. ISD 85Q: 2 kw ISD 127Q: 3 kw ISD 181Q: 4.5 kw ISD 2Q: 4.5 kw. 5. Supply and return air plenums. SAFETY FEATURES 1. HP and loss of refrigerant protection. 2. Anti-rapid cycle timer and internal overload for compressor protection. 3. Circuit breaker control circuits. 4. Time-and-temperature controlled electronic de-ice switch prevents icing up of the outdoor coil during heating cycle (OSA 2R only). 5. Frost protection on cooling cycle. 6. Sensor fault indication. 7. Crankcase heater prevents liquid refrigerant condensing in the compressors during the 'off' cycle. 8. Compressor minimum run time to ensure oil return. COMPRESSOR Each high efficiency scroll type compressor is hermetically sealed, quiet running and supported on rubber mounts to minimise vibration. REFRIGERATION PIPING The standard unit allows for a line length of up to 3 m. Max. height separations between units are : Reverse Cycle systems: Outdoor unit above indoor unit : 12 m Outdoor unit below indoor unit : 12 m. Cooling Only systems: Outdoor unit above indoor unit : 18 m Outdoor unit below indoor unit : 12 m. For extended line lengths contact your nearest temperzone sales office for additional details on piping requirements. The OSA 2 is shipped from the factory with a charge of HCFC-22 (R22) refrigerant sufficient for a 1 m line length. Liquid and suction service valves are provided. Accurator expansion devices control the flow of refrigerant. The matched indoor units are shipped with a holding charge of nitrogen. Both units have one flare and one brazed pipe connection. TANDEM PIPING When connecting two indoor units in tandem to the OSA 2R outdoor unit ensure the following: 1. Maximum line length specified for the outdoor unit must include both tandem legs. 2. Tandem legs must be as close as possible to equal, after leaving the common leg. 3. Ensure each 'T' joint connection is the same size as the common leg's pipe size, downsizing if necessary from there to each indoor unit. WIRING The electrical supply required (including voltage fluctuation limits) is: 3 phase 342-436 V a.c. 5 Hz with neutral and earth. The compressor crankcase heater requires a 24 hour power supply. A control panel, located in the outdoor unit, is fully wired ready to accept the main power supply. The manufacturer operates a quality management system that conforms to AS/NZS ISO 91:.

COMBINATIONS ISD 2Q (26 kw) OSA 2 ISD 127Q (12.7 kw) OSA 2 ISD 127Q (12.7 kw) ISD 181Q (18 kw) OSA 2 ISD 85Q (8.5 kw)

PERFORMANCE DATA COOLING CAPACITY (kw) Total = Total Capacity (kw) Sens. = Sensible Capacity (kw) E.A.T. = Entering Air Temperature = Nominal Capacity (kw) Note: Capacities are gross and do not include allowance for fan motor heat loss. Capacities are for close coupled systems. Interconnecting pipework will reduce capacity (refer page 6). MODELS INDOOR INDOOR COIL FAN OUTDOOR COIL ENTERING AIR TEMPERATURE C D.B. E.A.T. Indoor Outdoor AIR W.B. D.B. 23 27 31 35 39 43 SPEED Unit Unit l/s C C Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. Total Sens. 17 23 13. 9.3 12.6 9.1 12.2 9. 11.8 8.8 11.4 8.6 11. 8.5 ISD 127Q / OSA 2 75 19 27 13.7 1.7 13.3 1.5 12.9 1.4 12.5 1.2 12.1 1. 11.7 9.9 21 31 14.5 12. 14.1 11.9 13.7 11.7 13.2 11.6 12.8 11.4 12.4 11.3 17 23 8.6 6.1 8.4 6.1 8.2 6. 8. 5.9 7.8 5.8 7.5 5.7 ISD 85Q / OSA 2 5 19 27 9.2 7. 8.9 7. 8.7 6.9 8.5 6.8 8.2 6.7 8. 6.6 21 31 9.7 7.9 9.5 7.9 9.2 7.8 9. 7.7 8.8 7.6 8.5 7.5 17 23 18.5 13.4 18. 13.1 17.5 12.9 17. 12.7 16.5 12.5 16. 12.3 ISD 181Q / OSA 2 145 19 27 19.6.3 19..1 18.5 14.9 18. 14.8 17.5 14.6 16.9 14.4 21 31.7 17.3.1 17.1 19.6 16.9 19.1 16.8 18.5 16.6 17.9 16.4 17 23 27.2 19.6 26.4 19.3 25.7 19. 24.9 18.7 24.2 18.4 23.4 18.1 ISD 2Q / OSA 2 19 27 28.7 22.5 27.9 22.2 27.2 21.9 26.5 21.6 25.6 21.3 24.8 21.1 21 31 3.3 25.4 29.5 25.1 28.7 24.9 27.9 24.6 27.1 24.3 26.2 24. Indoor Air Flow Correction Factors @ nominal conditions Indoor Air Flow (%) -% -1% Rated +1% Total Capacity.95.975 1. 1.25 Sensible Capacity.89.95 1. 1.5 PIPE LENGTH CAPACITY LOSS ON COOLING CYCLE DUE TO PRESSURE DROP Note: Loss percentage is approximate only. No allowance made for vertical piping. Pipe Size (mm) Equivalent Line Pipe Length (m) System Liquid Suction 5 1 3 ISD 85Q / OSA 2 ISD 127Q / OSA 2 ISD 181Q / OSA 2 1 13 13 16 19 22 2 % 1.6 % 2.25 % 4 % 3.2 % 4. % 6 % 4.7 % 5.6 % 8 % 7.3 % 1 13 13 19 22 28 1 %.8 % 1.2 % 1.5 % 1.6 % 1.7 % 2.5 % 2.4 % 2.25 % 3.5 % 3.2 % 2.7 % ISD 2Q / OSA 2 13 28 1.8 % 3.75 % 5 % Suction Pipe Size OD Additional Pipe Length to allow per Bend Long 9 Radius (2 x pipe dia.) 16 mm.3 m 19 mm.4 m 22 mm.5 m 28 mm. m Reverse Cycle Systems MODELS Indoor Outdoor Unit Unit ISD 85Q / OSA 2R ISD 127Q / OSA 2R ISD 181Q / OSA 2R ISD 2Q / OSA 2R INDOOR ENTERING AIR TEMP. C D.B. 25 25 25 25 HEATING CAPACITY (kw) G = Gross Heating Capacity kw, based on nominal air flows. N = Net Heating Capacity kw allowing for average defrost. = Nominal Capacity (kw) OUTDOOR COIL ENTERING AIR TEMPERATURE (E.A.T.) C D.B. -4-2 2 4 6 8 1 G N G N G N G N G N G N G N G N 6.2 5.6 6.6 6. 7.1 6.3 7.5 6.4 7.9 6.7 8.5 7.7 9. 9. 9.3 9.3 6. 5.4 6.5 5.8 6.9 6.1 7.3 6.3 7.7 6.6 8.3 7.6 8.9 8.9 9.1 9.1 5.8 5.2 6.2 5.6 6.7 5.9 7.1 6.1 7.5 6.4 8. 7.3 8.5 8.5 8.8 8.8 9. 8.1 9.6 8.6 1.3 9.1 1.9 9.4 11.5 9.8 12.4 11.3 13.1 13.1 13.6 13.6 8.8 7.9 9.4 8.4 1. 8.9 1.6 9.1 11.3 9.6 12.1 11. 12.7 12.7 13.2 13.2 8.5 7.6 9.1 8.2 9.7 8.6 1.3 8.8 1.9 9.2 11.7 1.6 12.4 12.4 12.8 12.8 12.6 11.3 13.5 12.1 14.3 12.8.2 13.1 16.1 13.7 17.3.8 18.4 18.4 19. 19. 12.3 11. 13.1 11.8 14. 12.5 14.9 12.8.8 13.4 16.9.4 17.9 17.9 18.5 18.5 11.8 1.7 12.7 11.4 13.5 12. 14.4 12.4.2 12.9 16.3 14.9 17.3 17.3 17.9 17.9 18.9 17..3 18.3 21.6 19.3 23. 19.8 24.4.7 26.1 23.8 27.7 27.7 28.7 28.7 18.5 16.6 19.8 17.8 21.1 18.8 22.4 19.3 23.8.2 25.5 23.2 27. 27. 28. 28. 17.9 16.1 19.1 17.2.4 18.2 21.7 18.7 23. 19.5 24.6 22.4 26.2 26.2 27.1 27.1

PERFORMANCE DATA ISD 85Q AVAILABLE EXTERNAL PRESSURE (Pa) 1 ISD 181Q AVAILABLE EXTERNAL PRESSURE (Pa) l/s - Pa 1.1A 1.1A 1.A.9A - - - - - - - - l/s - W 7 6 1.9A 2.5A 2.8A 3.4A 1 4 5 6 AIR VOLUME (l/s) 2.5 m/s Face Velocity l/s - Pa 2.5A 2.A 3.2A 5 4 - - - - l/s - W 1.4 1.2 1 2.8A 4.A 5.7A 4 6 8 1 1 AIR VOLUME (l/s) 2.5 m/s Face Velocity 1..8.6.4 INPUT (watts) INPUT (kw) AIR HANDLING Note: In a free blow application, beware of exceeding indoor fan motor's full load amp limit. As filters are optional, air flows given are for ISD units without filter installed. ISD 127Q AVAILABLE EXTERNAL PRESSURE (Pa) 4 1.9A 1 ISD 2Q AVAILABLE EXTERNAL PRESSURE (Pa) 2.3A.8A l/s - Pa - - - - l/s - W 9 2.4A 3.7A 4.1A 4 5 6 7 8 AIR VOLUME (l/s) 2.5 m/s Face Velocity 1 3.5A 4.A 3.6A l/s - Pa 8 7 6 5 4 - - - - l/s - W 1.8 1.6 8.4A 4.5A 7.A 1 11 1 1 14 AIR F (l/s) 2.5 m/s Face Velocity 1.4 1.2 1..8 INPUT (watts) INPUT (kw) ISD 127Q (x2) ISD 85Q + 181Q ISD 2Q E.E.R. (cooling) 2.92 2.88 2.92 Indoor Fan Full Load Amps 5. (x2) 6.3 & 3. 5. (x2) Running Amps (Total System) / 17 / 17 / 19 / 16 25 / 14 / 14 Recommended External Fuse 4 A 4 A 4 A FILTERS - PRESSURE DROP PRESSURE DROP (Pa) Based on EU-2 rated filter media 4 FINAL PRESSURE 3 DROP 125 Pa 1 INITIAL (Clean Filter).5 1. 1.5 2. 2.5 Filter Areas: ISD 85Q -.211 m 2 ISD 127Q -.2 m 2 ISD 181Q -.48 m 2 ISD 2Q -. m 2 FILTER FACE VELOCITY (m/s)

PERFORMANCE DATA Indoor Unit - Supply Air Outlet MODEL ISD 85Q ISD 127Q ISD 181Q ISD 2Q FAN SPEED - - AIR F l/s 3 4 46 54 535 7 75 8 97 126 134 1355 9 SWL db(a) 73 75 77 65 7 77 75 77 Supply Air Outlet + Insulated Duct * MODEL ISD 85Q ISD 127Q ISD 181Q ISD 2Q FAN SPEED AIR F l/s 54 75 126 9 SWL db(a) 6 125 65 7 72 7 125 6 55 SOUND LEVELS Sound Power Levels (SWL) Test Conditions: BS 848 PT2 1985. Installation Type A (free inlet and outlet). Direct method of measurement (reverberant room). Measured in decibels re 1 picowatt. 25 6 7 72 74 74 54 25 56 OCTAVE BAND FREQUENCY Hz 5 1 k SOUND POWER LEVELS (SWL) db 6 73 72 7 74 6 73 73 OCTAVE BAND FREQUENCY Hz 5 1 k SOUND POWER LEVELS (SWL) db 6 55 2 k 55 6 56 2 k 5 6 4 k 53 53 7 4 k 47 55 * 1 metre of 25 mm insulated duct Outdoor Unit OCTAVE BAND FREQ. Hz SPL OCTAVE BAND FREQ. Hz MODEL FAN SPEED SWL db(a) 125 25 5 1 k 2 k SOUND POWER LEVELS db 4 k @ 3 m db(a) 125 25 5 1 k 2 k 4 k SOUND PRESSURE LEVELS db OSA 2 7 7 79 52 54 54 51 53 5 43 48 48 5 51 42 43 Sound Pressure Level (SPL) in decibels re µpa.

Dimensions (mm) PROJECTION Not to Scale ISD 85Q, 127Q Indoor Unit ISD 85Q ISD 127Q Net Weight 38 kg 45 kg Shipping Weight 41 kg 48 kg 85 C SPRING MTG CTRS D HANGING A 225 6 ELECTRIC HEATER BOX 195 135 285 FILTER BOX Note : Allow 5 mm minimum clearance to each access panel. 5 SPRING MTG 53 HANGING B 4 MOUNTING SLOTS x 9 CONDUIT HOLES REFRIGERANT CONNECTIONS 6 FAN VIA REMOVEABLE BASE & DRAIN TRAY MODEL ISD 85Q ISD 127Q 6 A 765 91 B 265 34 C 865 1 D 825 975 E 945 195 Recommended Pipe Sizes (mm OD) ISD 85Q ISD 127Q Suction: 19 22 Liquid: 1 13 36 OA 225 1 285 6 E OVERALL DRAIN 19 OD OA ISD 181Q Indoor Unit Net Weight Shipping Weight kg kg 6 195 135 8 1285 SPRING MTG CTRS 124 HANGING 1185 23 ELECTRIC HEATER BOX 35 FILTER BOX Note : Allow 5 mm minimum clearance to each access panel. 5 SPRING MTG 53 HANGING 165 865 CONDUIT HOLES REFRIGERANT CONNECTIONS MOUNTING SLOTS x 9 6 FAN VIA REMOVEABLE BASE & DRAIN TRAY 6 Recommended Pipe Sizes Suction: 22 mm OD Liquid: 13 mm OD 425 OA 23 35 18 1365 OVERALL DRAIN 19 OD OA 6

DIMENSIONS (mm) Not to Scale ISD 2Q Indoor Unit Net Weight 84 kg Shipping Weight 93 kg 8 1285 SPRING MTG CTRS 124 HANGING 1185 23 6 195 135 5 Note : Allow 5 mm minimum clearance to each access panel. 5 SPRING MTG 53 HANGING 165 865 CONDUIT HOLES REFRIGERANT CONNECTIONS MOUNTING SLOTS x 9 85 6 ELECTRIC HEATER BOX FAN VIA REMOVEABLE BASE & DRAIN TRAY 6 FILTER BOX 555 OVERALL 23 5 DRAIN 19 OD 1365 OVERALL OA OSA 2 Outdoor Unit MIN. CLEARANCE OSA 2C OSA 2R Net Weight 7 kg 211 kg Shipping Weight 2 kg 219 kg Note Materials and specifications are subject to change without notice due to the manufacturer's ongoing research and development programme. MIN. CLEARANCE 1 MIN. CLEARANCE MIN. CLEARANCE MIN. CLEARANCE Recommended Pipe Sizes Suction: 28 mm OD Liquid: 13 mm OD SERVICE 125 OA DIA. CONDUIT HOLES PROJECTION REFRIG. CONN'S DIA. DRAIN HOLE 5 MTG CTR 65 OA DIA. DRAIN HOLE 828 MTG CTR 7 5 1 DIA. SLOTS 5 124 OA DIA. DRAIN HOLE Available from AUCKLAND Ph. -9-279 525 Fax -9-275 WELLINGTON Ph. -4-5 32 Fax -4-5 49 CHRISTCHURCH Ph. -3-379 3216 Fax -3-379 56 6/4 Pamphlet No. 2356 temperzone limited 4 temperzone limited Head Office, Auckland : 38 Tidal Rd, Mangere, N.Z. Private Bag 9333, Otahuhu, NEW ZEALAND. Email sales@temperzone.co.nz Website: www.temperzone.biz temperzone australia pty ltd Head Office, Sydney : 7A Bessemer St PO Box 48, Delivery Centre, Blacktown, NSW 2148, AUSTRALIA. Email sales@temperzone.com.au SYDNEY Ph. (2) 8822- Fax (2) 8822-51 ADELAIDE Ph. (8) 8333-1833 Fax (8) 8333-1844 SINGAPORE Ph. SNG 33 4292 Fax SNG 35 8 MELBOURNE Ph. (3) 9551-7422 Fax (3) 9551-855 BRISBANE Ph. (7) 3399-2544 Fax (7) 3399-27 NEWCASTLE Ph. (2) 49-15 Fax (2) 49-511 REGISTERED AS/NZS ISO 91: S U P P L I E R PERTH Ph. (8) 9314-3844 Fax (8) 9314-3855 TOWNSVILLE Ph. (7) 4773-95 Fax (7) 4773-91 HOBART Ph. (3) 72- Fax (3) 72-56 Manx Press