Installation, Operation and Maintenance Manual

Similar documents
Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual

VENTLESS EXHAUST HOOD OPERATORS MANUAL AND PARTS LIST REV. MAY 2016

Installation, Operation and Maintenance Manual

Introduction to the Exhaust Fan Interceptor Commercial Exhaust Fans from a Service Perspective

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Technical Installation, Start-up, Operation & Maintenance Manual For ENERGENICS KARTWASH PREMIER WITH TOUCHPAD DISPLAY

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual RTE14S & RTE14S-2. For the Taco Bell "Rethermalizer" Model Numbers

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

Technical Installation, Start-up, Operation & Maintenance Manual For ENERGENICS KARTWASH PREMIER WITH TOUCHPAD DISPLAY

Control Panel For Water Wash Hoods AM2

Installation Instructions Remote Blowers

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY

Winnipeg Fire Department Fire Prevention Branch

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

AccuBrine automated brine maker Technical Specifications

Standard Features. Performance/Capacities

Lombard Fire Department Bureau of Fire Prevention COMMERCIAL HOOD & DUCT SYSTEMS

.4 Section Ductwork Low Pressure Metallic to 500 Pa..3 ANSI/ARI 640 Commercial and Industrial Humidifiers.

Installation Instructions Dual Fuel Ranges

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment

EVALUATION SUBJECT: FIRE SUPPRESSION RANGE HOOD DIVISION: MECHANICAL SECTION: COMMERCIAL-KITCHEN HOODS.

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY

NFPA 96, 2017 REVIEW SUMMARY

INSTALLATION AND OPERATION MANUAL STEAM COIL BASE CONVECTION STEAMER MODEL SCX-16

08/17/2011 Rev. 4 PULL STATION EXHAUST HOOD 10 TO 20 FEET FROM HOOD LOCATE ONE NEAR EVERY POINT OF EGRESS FROM HOOD

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

ACT Cartridge Dust Collector

DIVISION FINNED WATER-TUBE BOILERS

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL AUTOBOOSTER IMPORTANT SAFETY INFORMATION

Steam Humidifier Models 1150 and 1160

Installation & Operation Manual For ENERGENICS In-Line Space Saver Lint Filters

INSTALLATION OPERATION MAINTENANCE

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

PRO SERIES IMPORTANT SAFETY INFORMATION

INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS: GTS-30 GTS-40

SE Series Modular Electric Stone-Hearth Deck Oven INSTALLATION & OPERATION MANUAL LBC BAKERY EQUIPMENT, INC st Ave NE Tulalip, WA 98271, USA

INSTALLATION and OPERATION MANUAL DIRECT STEAM KETTLES MOUNTED ON ELECTRIC BOILER BASE CABINET MODELS: EMT-6 EMT-10 EMT-12 EMT-6-6 EMT-10-6 EMT-10-10

FT1000 FLIGHT-TYPE DISHWASHER

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Installation Instructions

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

SECTION PACKAGED HEAT TRANSFER SYSTEM

1-866-PENNERS

FT1000 ENERGY RECOVERY WITH BLOWER DRYER FLIGHT-TYPE DISHWASHER

40LM Hz INSTALLATION, START-UP AND SERVICE INSTRUCTIONS CHILLED WATER FAN COIL UNIT

FT900SDBD DUAL RINSE FLIGHT-TYPE DISHWASHER

Dear Concessionaire,

HOMEADVANTAGE II IMPORTANT SAFETY INFORMATION

MODEL: JRSVH SERIES JEAN S RESTAURANT SUPPLY 426 SOUTH STAPLES CORPUS CHRISTI, TEXAS PH: (361)

Project Name: Project Address: Installer Name: Installer Address: Date of Inspection:

ATKINSON DYNAMICS SPEAKERS

XRRS Specification Fire Ready Hood

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

TABLE OF CONTENTS INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation.

Installation and operation manual

DS 2001 REVISED Humidifier Assembly and Instruction Manual

FT900BD FLIGHT-TYPE DISHWASHER

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

CAUTION signals a situation where minor injury or product damage may occur if you do not follow instructions.

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

Installation, Operation and Maintenance Manual

Commercial Water Source Heat Pump Water Heater Operations and Installation Manual

DIVISION FINNED WATER-TUBE WATER HEATERS

Cascade Premier and Elite Premier Bathing Systems with Aqua-Aire Installation / Assembly Instructions

Revitalize Building Mechanical Systems (4619)

DIVISION FINNED WATER-TUBE BOILERS

Energy-Saving Demand Ventilation System

FT1000 ENERGY RECOVERY WITH BLOWER DRYER FLIGHT-TYPE DISHWASHER

ClearFire. Startup Guide. Model CFH. Horizontal Steam Boiler

User Manual AIR HOG. Vacuum Booster REV. 3/20/ Stowe Dr. Poway, CA P: (858) F: (858)

SYSTEM 2000 CHILLED WATER (CAC) EC SERIES -INSTALLATION OPERATIONS AND MAINTENANCE MANUAL-

Operation & Maintenance Manual MONSOON WET DOWNDRAFT TABLE. Visit our Website for more information on this product.

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

FINNED WATER-TUBE POOL HEATERS

FT1000S BASE FLIGHT-TYPE DISHWASHER

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

WATER-TUBE POOL HEATERS

Installation Instructions

INSTALLATION, OPERATION AND MAINTENANCE

INSTALLATION GUIDE Dual Fuel Ranges

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

INSTALLATION & OPERATION MANUAL FOR Achiever Charbroilers

DIVISION FINNED WATER-TUBE BOILERS

SECTION COMMERCIAL-KITCHEN HOODS

Installation Instructions

DIVISION FINNED WATER-TUBE WATER HEATERS

Installation Instructions

K Specifications. Max. Water Volume

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

Installation, Operation & Maintenance: Field-Installed Electric Heater for RXT Series Units

Transcription:

Document 483502 Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with these instructions will result in voiding of the product warranty and may result in personal injury and/or property damage. The duct sump is a piece of duct designed to be installed at the low point(s) of long horizontal duct runs to collect and drain off moisture, liquid grease, etc. The Uniform Mechanical Code (UMC) and International Mechanical Code (IMC) specifies horizontal grease duct run must slope not less than one-fourth unit vertical in 12 units horizontal (2% slope) towards hood or toward the sump if less than 75 feet. If greater than 75 feet, the horizontal duct run must slope not less than one unit vertical in 12 units horizontal (8.3% slope). This product allows the more complex duct runs where sloping horizontal runs back to the hood are not feasible and stays within a workable horizontal clearance. The duct sump is controlled by an Auto Scrubber Control Panel. Table of Contents Receiving, Unpacking, Storage, Handling.... 2 System Components.... 2 Auto Scrubber Control Panel (ASCP).... 2 User Interface.... 2 Installation.... 3 Auto Scrubber Control Panel (ASCP).... 3 User Interface.... 3 Plumbing Connections.... 4 Typical Plumbing Connection Layout.... 4 Electrical Connections.... 5 Typical Electrical Connection Layout.... 5 Wash Operation.... 6 Wash Sequence of Operation.... 7 Detail.... 8 Typical Layout.... 8 Maintenance.... 9 Maintenance Log....10-11 Our Commitment....Backcover General Safety Information Only qualified personnel should install this unit. Personnel should have a clear understanding of these instructions and should be aware of general safety precautions. Improper installation can result in grease fires as well as other potential hazards. If more information is needed, contact a licensed professional engineer before moving forward. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC), and the National Fire Protection Agency (NFPA), where applicable. Follow the Canadian Electric Code (CEC) in Canada. Never open the access panel on the duct sump if the exhaust fan is on or if the sump is washing. Duct sumps are shipped with and controlled through the Auto Scrubber Control Panel (ASCP). The ASCP will be provided with a separate installation, operation, and maintenance manual. For more detailed information on the ASCP, please refer to manufacturer s website. 1

Receiving Upon receiving the product, check to make sure all items are accounted for by referencing the bill of lading to ensure all items were received. Notify the carrier if any damage is noticed. The carrier will make notification on the delivery receipt acknowledging any damage to the product. All damage should be noted on all of the copies of the bill of lading which is countersigned by the delivering carrier. If damaged upon arrival, file a claim with the carrier. Any physical damage to the unit after acceptance is not the responsibility of the manufacturer. Unpacking Verify that all required parts and the correct quantity of each item have been received. If any items are missing, report shortages to your local representative to arrange for obtaining missing parts. Storage If a duct sump must be stored prior to installation, it must be protected from dirt and moisture. Indoor storage is highly recommended. Handling Carefully move the sump to prevent denting or damaging. System Components The duct sump consists of a piece of pitched ductwork fabricated from 16 gauge stainless steel designed to the specific duct size and equipped with a spray manifold, and drain with pre-flush and overflow. Access panel(s) are provided and designed per NFPA 96. Auto Scrubber Control Panel (ASCP) The control cabinet contains the water and electrical components, including the Programmable Logic Controller (PLC), that controls wash sequencing and operations. The control cabinet also includes the detergent reservoir, detergent pump, and other water piping. User Interface The user interface will be either a keypad with LCD screen or touch screen. It can be mounted on the Auto Scrubber control cabinet, hood or shipped loose for remote mounting. It will provide a WASH button (WASH ON/OFF with touch screen), and a means of turning on/ off hood fans and lights, if applicable. It also includes system alarm notifications to alert of any faults on the system, such as low detergent alarm. SYSTEM FAULT MENU NAV Keypad Touch Screen 2

Installation 1. Position duct sump inline with the horizontal ductwork. Per IMC and UMC, the horizontal duct run must slope not less than one-fourth unit vertical in 12 units horizontal (2% slope) towards hood or toward the sump if less than 75 feet (22.8 m). If greater than 75 feet (22.8 m), the horizontal duct run must slope not less than one unit vertical in 12 units horizontal (8.3% slope). Per NFPA 96, duct sump along with ductwork has to be at least 18 inches (45.7 cm) to combustible material, 3 inches (7.6 cm) to limited combustible material, and 0 inches (0 cm) to non-combustible material. Make sure these and all local code requirements will be met before welding. Duct sump is not intended to be mounted outdoors. 3. After welded in place, make all plumbing connections, refer to page 4. If ductwork and duct sump need to be fire wrapped, make sure access panel(s) (if equipped) on the duct sump can still be removed. If ductwork and duct sump are to be enclosed in a field-applied grease duct enclosure, make sure the enclosure also doesn t block these access panel(s). ASCP and User Interface Consult ASCP Installation, Operation, and Maintenance manual for installation information. 2. Weld ductwork on inlet and outlet of duct sump. Welds need to be liquid-tight, continuous and external. One inch flanges are provided at the inlet and outlet collars. Acceptable duct-to-duct connections (per NFPA 96) include flange with edge weld or flange with filled weld. Butt-welded connections are not permitted. Consult NFPA 96 for details. Ductwork Duct Sump Ductwork Duct Sump Flange with Edge Weld Flange with Filled Weld 3

Plumbing Connections 1. Install factory provided backflow preventer (shipped loose with ASCP) and drain connection per local code. FROM 1 INCH HOT WATER SUPPLY Backflow Preventer TO ASCP 1 INCH HOT WATER INLET 2. Bring 1-inch (25.4 mm) hot water supply line to the backflow preventer. 3. Plumb 1-inch (25.4 mm) line from the outlet of the backflow preventer to the hot water inlet connection in the ASCP. 4. Plumb 1-inch (25.4 mm) line out of ASCP hot water outlet connection to (each) duct sump solenoid valve (factory provided valve, shipped loose) and Auto Scrubber hood (if applicable). Each duct sump valve is a 3/4-inch valve; a reducer (by others) will be needed. 5. Plumb 3/4-inch (19.05 mm) line from solenoid valve to inlet fitting on the side of the corresponding duct sump. 6. Plumb 1-1/2 inch (38.1 mm) drain from bottom of sump to a grease trap in the building. Consult local code for grease trap requirements. Hot water temperature should be 140 F (60 C) While the duct sump is washing, water pressure in the control panel should be between 40 and 70 PSI (275.8 and 482.6 kpa). Typical Plumbing Connection Layout Building Water Supply Plumbing Key Hot Water Piping Cold Water Piping Backflow A Preventer Provided by Accurex; D B field installed. Drain required for backflow preventer. Plumbing connections made here Auto Scrubber Control Panel (ASCP) C E First Auto Scrubber Hood (if applicable) F HOT WATER CONNECTIONS: A 1-inch hot water supply from building to Backflow Preventer B 1-inch hot water piping from Backflow Preventer to control cabinet C 1-inch hot water piping from control cabinet to hood(s) and/or sump(s) COLD WATER CONNECTIONS, optional with continuous cold water mist D 3/4-inch cold water supply from building to control cabinet E 3/4 inch cold water piping from control cabinet to hood(s) DRAIN CONNECTIONS FROM AUTO SCRUBBER HOOD(S): F 2-inch male NPT connection to building drain with grease trap (one per hood section) G 1.5-inch female NPT connection to building drain with grease trap (one per sump) Each additional Auto Scrubber Hood (if applicable) F G 4

MENU NAV SYSTEM FAULT Electrical Connections All wiring of electrical equipment must be done to meet NEC and local codes. It is recommended that shielded wire be used for all low voltage connections (24V or less) to prevent signal interference with other high voltage circuits. All 115 VAC field wiring (or higher) must be high temperature rated and must be routed through hard or flex conduit. All low voltage field wiring should be plenum rated if not routed through conduit. To reduce the likelihood of electromagnetic disturbance, avoid routing high and low voltage cables in the same conduit. Consult ASCP Installation, Operation, and Maintenance manual for complete wiring instructions for the ASCP control panel. Solenoids if equipped Each duct sump will be provided (shipped loose) with a 3/4-inch solenoid valve. Each valve will need to be wired back to the ASCP panel. Solenoids are 24 VAC (use 18 gauge, stranded wire). U1 NO_ NO_ NO_ NO_ WO-_A WO-_A WO-_A WO-_A WASH SOL _ SV_ WASH SOL _ SV_ WASH SOL _ SV_ WASH SOL _ SV_ 24C This is an example of four duct sumps being controlled by one ASCP panel REMOTE SOLENOID(S) DUCT SUMP Typical Electrical Connection Layout Electrical connections made in here F or User Interface (Keypad or Touch Screen) Building Breaker Panel (by others) A B C D E G H I First Auto Scrubber Hood (if applicable) Auto Scrubber Control Panel (ASCP) G H I Each additional Auto Scrubber Hood (if applicable) Wiring Key High Voltage ( 115V) Low Voltage ( 24V) A B C D E F G H I J K L 115/1, 15A Circuit (Control Power) 115/1, 15A Circuit (Light Power) Input Power for Exhaust Fan(s) (if applicable) Input Power for Supply Fan(s) (if applicable) Input Power for Supply Fan(s) Controls (if applicable) Control Wiring to User Interface (Keypad or Touch Screen) Cable(s) provided by Greenheck Power to Hood Lights Control Wiring to Wash Solenoids Control Wiring to Temperature Sensors Output Power to Exhaust Fan(s) (if applicable) Output Power to Supply Fan(s) (if applicable) Control Wiring to Supply Fan(s) (if applicable) H J K L Exhaust Fan(s) : Exhaust fan wiring will depend on type of exhaust fan Supply Fan : Supply fan wiring will depend on type of supply fan 5

Wash Operation For ASCP controller menu navigation, user interface navigation, and initial start-up procedures, see ASCP Installation, Operation, and Maintenance manual. A duct sump wash can be initiated through a number of different options. Wash by Button (Factory default = ON): A wash can be initiated through pressing either the WASH button (if equipped with a keypad) or by pressing WASH ON/ OFF icon (if equipped with a touch screen). Wash by Digital Input (Factory default = OFF): A was can be initiated through engaging a configured digital input on controller. For the correct terminals to wire this digital input, please reference the Auto Scrubber Control Panel wiring diagram. Wash by BMS Interface (Factory default = OFF): A wash can be initiated daily at a specific time. If this option is enabled, this time can be field adjusted within the controller and touch screen, if equipped. Wash by Scheduler (Factory default = OFF): A wash can be initiated daily at a specific time. If this option is enabled, this time can be field adjusted within the controller and touch screen, if equipped. When a wash cycle has been initialized, all connected Auto Scrubber hoods will individually be washed first, then the duct sumps will be washed in order starting with 1. If Auto Scrubber hoods are also connected to the system, they will be individually washed first (before the sumps). A wash cycle can be stopped at any time by pressing the WASH button (if equipped with a keypad) or by the WASH ON/OFF icon (if equipped with a touch screen). When duct sumps are washing, fans cannot run, unless: A kitchen fire is detected A sensor linked to any Auto Scrubber hood fails, or any temperature sensor exceeds the temperature interlock on setpoint If the Auto Scrubber control panel is equipped with no fan controls (ASCP-W) and the fan input is triggered 6

Wash Sequence of Operation The previously stated items regarding ending a wash cycle/skipping a hood wash still apply. Please use this in conjunction with the information found in Wash Operation section found on page 6. WASH CYCLE ENABLED by User Interface Wash Button by Digital Input by BMS Interface by Scheduler Sump Wash Cycle Factory Default Times (seconds) Sump Prewash 10 NO Any Auto Scrubber Hoods configured with system? Hood Pre-Wash Delay Start next Auto Scrubber Hood Wash Sump Wash Times 60 Sump Detergent Injection Times 15 (starts 5 seconds after wash time begins) Pre-Soak Solenoid 1 Opens Delay for 30 seconds Start Sump Washes Pre-Soak Spray Time Detergent pump ON Turn off all fan(s) Solenoid 1 Closes Pre-Soak Detergent Injection Time Sump Pre-Wash Delay Soak Time Wash Top of Filters Solenoid 1 Opens Detergent pump OFF Sump Solenoid Opens Wash Sump Delay for 5 seconds Delay for 5 seconds Top of Filters Wash Time Solenoid 1 Closes Between Sequence Delay Detergent pump ON Top Wash Detergent Injection TIme Detergent pump OFF Sump Wash Time Sump Solenoid Closes Detergent pump ON Sump Detergent Injection Time Detergent pump OFF Wash Bottom of Filters Solenoid 2 Opens Delay for 5 seconds Another Sump available to be washed? YES Between Sump Delay Bottom of Filters Wash Time Detergent pump ON NO Solenoid 2 Closes Bottom Wash Detergent Injection TIme WASH CYCLE COMPLETED Drip Dry Time Detergent pump OFF Fan Dry Enable OFF Another Auto Scrubber hood available to be washed Average water usage will be 1.1 GPM per linear feet (depth) of duct sump (at 40 PSI). ON (Default) NO Fans controlling Auto Scrubber Hood ON Fan Dry Time Fans controlling Auto Scrubber Hood OFF Sumps available to be washed? NO WASH CYCLE COMPLETED YES Wash times are based on factory tests. Actual required cleaning time will vary based on cooking equipment, fuel type, cooking frequency, and the food prepared. The table shown above should be used as a starting point. After a few weeks, the field can make adjustments as necessary based on cleanliness of sump upon inspection. 7

Detail 3/4 inch Inlet Water Connection Bolted Access Panel (both sides if width is greater than 36 inches) AVAILABLE SIZES: Width: 14 50 inches Height: 12 48 inches Length: 24 inches Slope duct to sump as per local codes Slope duct to sump as per local codes Length 1-1/2 inch Drain Overflow Height 1-1/2 inch Drain plumb according to local code 1/8 inch Copper Pre-flush Line helps keep the drain clear Width Typical Layout 3/4 inch Remote Solenoid Valve Factory Provided, Installed in Field 24 VAC from Controls 3/4 inch Remote Solenoid Valve Factory Provideed, Installed in Field 24 VAC from Controls To Exhaust Fan Slope Slope Slope Slope Slope 1 inch Hot Water Supply from Reduced Pressure Backflow Preventer (RPBP) (RPBP provided with ASCP) PIPE BY OTHERS KITCHEN HOOD To Drain To Drain 1 inch Hot Water Line outgoing to Dump Sumps Pressure Gauge Temperature Gauge Check Valve Shock Arrestor 1 inch Ball Valve TANK W/ FLOAT Detergent Pump ELECTRICAL CONTROLS Auto Scrubber Control Panel (ASCP) WATER REQUIREMENTS Water Temperature = 140 F Water Pressure = 40 PSI to 70 PSI Average Water Usage = 1.1 GPM per Linear Foot of Duct Width (at 40 PSI) 2.5 gallon Detergent Tank 8

Maintenance It is recommended that the duct sump(s) be washed daily using the ASCP control system on a schedule (during non-cooking operation). Detergent must be refilled when low detergent is detected. Duct sumps opened up (via access doors) and washed manually with the rest of the ductwork as required when cleaning the entire exhaust system. Manually cleaning frequency shall be determined based on routine inspections and a determination by the AHJ. NFPA 96 (2017) Table B.11.3 provides the following grease build-up inspection frequency table. Schedule of Inspection for Grease Buildup Type of Volume of Cooking Inspection Frequency Systems serving solid fuel cooking Monthly operations *Systems serving high-volume Quarterly cooking operations Systems serving moderate-volume Semiannually cooking operations Systems serving low-volume Annually cooking operations * High-volume cooking operations include 24-hour cooking, charbroiling, and wok cooking. Low-volume cooking operations include churches, day camps, seasonal businesses, and senior centers. Reproduced with permission from NFPA 96-2017: Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations, Copyright 2016, National Fire Protection Association. This material is not the complete and official position of the NFPA on the referenced subject, which is represented only by the standard in its entirety which can be obtained through NFPA web site at www.nfpa.org 9

Maintenance Log 10

Maintenance Log 11

Our Commitment As a result of our commitment to continuous improvement, Accurex reserves the right to change specifications without notice. Specific Accurex product warranties are located on accurex.com within the product area tabs and in the Library under Warranties. P.O. Box 410 Schofield, WI 54476 Phone: 800.333.1400 Fax: 715.241.6191 Parts: 800.355.5354 accurex.com 12 483502, Rev. 1, August 2018 2018 Accurex, LLC