Figure 30: Sample Case 8

Similar documents
1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

Power System Protection Part 2 Dr.Prof. Mohammed Tawfeeq. Zones of Protection

I/O ZONE 560/583 AND OPERATION MANUAL

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

CONTROL PANEL INSTRUCTIONS RSQ-4

POWERFOIL X3.0 ELECTRICAL SPECS & DIAGRAMS

APPLICATION NOTE. Applying pressure sensing in arc flash protection applications with air magnetic circuit breakers

SEL Arc-Flash Solutions

SEL Arc-Flash Solutions

Products :: Circuit Protection :: Thermal Circuit Breakers

PGR-8800 TECHNICAL FAQ

things simple. At any rate, it is an elementary system and there seems to be little possibility of trouble.

Reyrolle Protection Devices. 7PG26 DAD High Impedance Current Relay. Answers for energy

Standard PRC Protection System Misoperation Identification and Correction

REA 105 Arc Protection Module. Operator s Manual

Step by Step Detailed Procedure Expected Result Observations Verify power off at all loads on emergency power. Verify all loads have power.

ELECTRICAL BULLETIN

Contents. Preface. Chapter 2 Faults, types and effects The development of simple distribution systems Faults-types and their effects 7

Appendix B. FRCC regional application of the term transmission Protection Systems

Electrical Energy department

2012 Edition. Tech Topics: Standards & Codes. Note 4, Issue 1. Points of Interest: Introduction. Background. Changes to Definitions in Article 100

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Heat Pump Water Heater (Generation 4) Troubleshooting (Effective 1 Nov 2016)

VACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES

FACILITY CONNECTION STANDARD

M2500 Engine Controller Installation Manual

NERC Requirements for Setting Load-Dependent Power Plant Protection: PRC-025-1

Standard PRC Protection System Misoperation Identification and Correction

Relay Performance Index for a Sustainable Relay Replacement Program

Three Terminal 230kV System Protection and Restoration at Calpine s Creed and Goose Haven Energy Centers Suisun City, California

SECTION AUTOMATIC TRANSFER SWITCHES

RD:30 Specification No. TI/SPC/PSI/AUTOTR/0090 For 50U5/150 MVA, 220/132 kv Auto Transformer

Standard PRC Transmission Relay Loadability

SECTION 7 AIR CONDITIONING (COOLING) UNIT 39 CONTROLS

SECTION 7 AIR CONDITIONING (COOLING) UNIT 39 CONTROLS UNIT OBJECTIVES UNIT OBJECTIVES. After studying this unit, the reader should be able to

Gasflag. Single Channel Control Panel Alarm Only Apparatus. Installation, operating and maintenance instructions, M07225.

Product Specifications 4 Breaker Main Disconnect Panel with Undervoltage Trip

.4 Do complete installation in accordance with latest Electrical Bulletins of the local inspection authority.

USER MANUAL. Fan coil units FWC06B7TV1B FWC07B7TV1B FWC08B7TV1B FWC09B7TV1B FWC06B7FV1B FWC07B7FV1B FWC08B7FV1B FWC09B7FV1B. Cover Cover.

Standard PRC 004 5(i) Protection System Misoperation Identification and Correction

ANSI/NETA Standards Update

Synco living. Train the Trainer. Commissioning Safety & Security. Spring 2008 Page 1/21 Train the Trainer - Spring 2008

Refrigeration System with a Capillary Tube and a Thermostat

UPM I. Unit Protection Module. Installation and Operation Manual (2015/06)

NFPA 70E Arc Flash Considerations for MV Equipment. By: Dominik Pieniazek, P.E. HV Engineering, LLC

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

Owner s Manual. Revillusion Suites Osbourne Revillusion Suite OSB20-AU Windlesham Revillusion Suite WDS20-AU Strata Revillusion Suite STA20-AU

SECTION LIGHTING CONTROL DEVICES

SIPROTEC Products and Solutions for Protection Systems

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Electrical. Bi-Metallic Thermal Cutouts. Linear Thermal Cutouts

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

DATASHEET. Burner control unit FDA 601x

REACH-IN SAFETEMP (-AAC)

DC INVERTER AIR TO WATER HEAT PUMP AC series Heating & Cooling series CX30

Verasys System Operation Overview Technical Bulletin

Arc Flash Codes & Compliance: What You Need to Know to Deliver Both Protection and Performance

To: Honorable Public Utilities Board Submitted by: /s/ Douglas Draeger AGM Engineering and Operations

Product Specifications 3 Breaker Main Disconnect Panel with Undervoltage Trip

SECTION ENCLOSED CONTROLLERS

Troubleshooting Guide

Heat Pump Defrost Board Replacement Kit

PART 4 ELECTRICAL STANDARDS

Molded Case Circuit Breakers, Bulletin 140G

Brown University Revised June 29, 2012 Facilities Design & Construction Standards SECTION ELECTRICAL DESIGN CRITERIA

Construction Electrical

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

TRANSMISSION ENGINEERING STANDARDS SUBSTATIONS

A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

DIGITAL TEMPERATURE RELAY TR-100

7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for Infrastructure & Cities.

INSTALLATION & OPERATION MANUAL

DEIF A/S. Description of options. Option M17, Configurable inputs and RPM supervision Engine Controller EC-1/EC-1M. Description of option

Arc Fault Protection System D1000

What Utility Analytics means to Exelon

D1000 Arc-fault Protection System

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

Student Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

TRANSMISSION ENGINEERING STANDARDS SUBSTATIONS

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

VAmP 120. Arc Flash Protection Units. Arc Protection. Customer benefits

CONTENTS AUTOMATIC TRANSFER SWITCHES

Changes to NFPA 70E. - The Role of PdM &Safe PdM Work Practices. Tim Rohrer Exiscan LLC

Why AC800M High Integrity is used in Burner Management System Applications?

The CAB & DAB Air Curtains

Memco Panachrome Universal Controller Installation Guide

Electrical Safety Through Design. Mersen EP formerly Ferraz Shawmut

Motor Solo Run. Power cable energized (2 hours)

LZP-2 ZONE CONTROL PANEL

STROBE / SOUNDER INTERFACE

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

US Navy Leading the Way in Switchboard Protection

Distribution Control Center Operator Training

General Routing Interface

NXM2G Installation and Operating Manual

Powerohm Resistors Digital HRG System

CONTACTORS FOR AEROSPACE GROW SMARTER AND MORE CAPABLE

Transmission Line Protection End to End Testing

Transcription:

6.9 Sample Case 8 C-A, φ-φ fault on Line 512 Hidden failure: Line 504 PCB scheme low set fault detector picked up This case illustrates the security of the line. With the low set fault detector of the PCB scheme picked up, the scheme operates as an overcurrent relay. The region of vulnerability is any fault with fault current greater than the high-set fault detector setting. In this example, the PCB scheme operates on fault current in 1½ cycles. Zone 1 PCB Trips Zone 1 Extension Trips Figure 30: Sample Case 8 Extension supervises the PCB scheme. Since the fault is not a zone 1 fault, but is a zone 2 fault, the method waits until the coordination timer expires before permitting a trip. The protection scheme is still dependable since a trip is eventually allowed. 42

6.10 Sample Case 9 B φ, φ-g fault on Line 502 Hidden failure: Line 301 Directional Overcurrent element failed In this case, the Line 301 Directional Overcurrent directional element fails picked up, turning the relay into a non-directional overcurrent relay. The region of vulnerability depends on fault current. The Line 301 Directional Overcurrent eventually trips on fault current. Voltage and current supervision determines the fault direction, and blocks the Line 301 DOC Trips RSS blocks trip Figure 31: Sample Case 9 trip of the relay. Therefore, line security is increased. In reality, Line 502 relays clear the fault before the overcurrent relay operates. 43

6.11 Sample Case 10 B-C, φ-φ internal fault, Transformer #1 No hidden failure This is an internal φ-φ transformer fault. The harmonic restraint percentage differential method supervises the existing transformer differential relay. The existing relay recognizes a fault in approximately 1 cycle, and the RSS permits a trip ¼ cycle Transformer #1 Differential Trips RSS Differential Trip Figure 32: Sample Case 10 later. Protection system security and dependability is maintained. 44

6.12 Sample Case 11 Transformer #1 Energization Hidden failure: Transformer #1 restraint coil shorted This case illustrates the harmonic restraint of the differential supervision method. With a restraint coil shorted, the existing transformer differential relay trips during energization of the transformer. Inrush currents are high in 2 nd harmonics. The Diff Figure 33: Sample Case 11 method restrains trip for high levels of 2 nd harmonics. This results in improved security of the protection system. 45

6.13 Sample Case 12 A-B, φ-φ fault on Line 502 Breaker B502T503 failed This is a normal breaker failure case. Line 502 relays operate for a φ-φ fault. B502 and B502T503 should operate to clear the fault, but B502T503 fails. Breaker failure is supervised by a timer in the RSS. The RSS permits the breaker failure scheme to operate when this timer expires, and if the breaker is still closed. In this instance, the RSS B502T503 Breaker failure timer B503 Opens Figure 34: Sample Case 12 breaker failure scheme opens B503. Therefore, the RSS maintains dependability. 46

6.14 Sample Case 13 Normal Mode A-B, φ-φ fault on Line 502 Hidden failure: B502T503 breaker failure timer fails picked up In this case, the B502T503 breaker failure timer fails picked up, causing an immediate operation of the breaker failure scheme on a line trip, even though B502T503 opens sucessfully. The RSS supervises breaker failure through a timer. The timer B502T503 breaker failure timer Breakers Trip Figure 35: Sample Case 13 permits the breaker failure scheme to operate when the timer expires, and if the breaker is closed. B502T503 is open in this case, so the RSS blocks the B502T503 breaker failure scheme from tripping anymore breakers. This increases protection system security. 47

6.15 Sample Case 14 Out-of-Service mode A-B, φ-φ fault on Line 501 No hidden failure This case illustrates the Out-of-Service mode of the RSS. The Line 501 PCB scheme trips for the φ-φ fault on the line, and the associated breakers operate ½ cycle later, with no involvement from the RSS. All output contacts controlled by the RSS are PCB Trips Breakers Trip set closed for this mode. Figure 36: Sample Case 14 48

6.16 Sample Case 15 Out-of-Service mode A-B, φ-φ fault on Line 507 Hidden failure: Line 501 Zone 3 Timer fails picked up This case shows the Out-of-Service mode associated with a hidden failure. The region of vulnerability for the zone 3 timer failure is the zone 3 reach beyond the remote bus. The φ-φ fault is in this region. The zone 3 relay operates in approximately 2 cycles after the fault. Since the RSS is Out-of-Service, and has set all output contacts closed, Zone 3 Trips Breakers Trip Figure 37: Sample Case 15 the breakers trip 1½ cycle after the zone 3 incorrectly operates. 49