User manual. KNXpar. version

Similar documents
User manual. KNXgal. version

User Manual Doc.Ref : EVO-KNX-UM. EVO-KNX Paradox KNX Interface ELAUSYS EVO-KNX. KNX Interface for Paradox alarm system. User Manual.

CBI-064. User Manual. Caddx to KNX-BUS Interface

PBI Manual. Paradox to KNX-BUS Interface

ModBus DE-1 INSTALLATION AND USER MANUAL

P2267 NETWORK INTERFACE

Added password for IP setup page : Password must be in IP format!

Roo232 User Guide. Revision 1.0. Copyright 2006 RoboDynamics Corp

USER MANUAL FOR OPERATING SYSTEM

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

Installation Manual GalaXy G2 / G3 / GD. o Settings GalaXy o Linking with iprotect o Keymap

User Manual Doc.Ref : JA-KNX-UM. JA-KNX Jablotron KNX Interface ELAUSYS JA-KNX. KNX Interface for Jablotron alarm system.

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

E21.X.01.6C-05 Operating Manual EB2000 MC page 1. Operating manual EB2000 MC. for up to 9 sensor modules. Version 3.0

IntesisBox BACnet/IP Server - Notifier ID3000 series

HRX3000. Technical Manual

KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no )

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D

RS485 MODBUS Module 8AI

PTE0705 Electric Fence Monitor

Compod. Instruction Manual IM-COMPOD Revision: C.1, November 2010

DTSX200 Communications(Modbus) Guide

FCD-wire Contents. List of Figures

CAN bus-based I/O module, CIO relays Mounting Terminals and wiring Commissioning, using the utility software

Shanghai Xixun-----professional supplier of Led sign control system website: un.com Step2, plug u-disk into computer, open LED editor and choose upgra

HRX Technical Manual. Version 1.2

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

DOCUMENTATION IPS640

DOCUMENTATION IPS640

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

Compod. Instruction Manual IM-COMPOD Revision: F, December 2015

GLOBAL. InstallatIon & operation manual

LineGuard 2300 Program User Manual (FloBoss 107)

Metasys Integrator Compu-Aire Application

Sensors SR Programming manual

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

Avigilon Control Center System Integration Guide

Security designed for your lifestyle

Device Technology. Supply Operating voltage Implemented via the bus KNX: V DC XIB: 12 V DC (rated voltage) Voltage range: 10.

FL500 Modbus Communication Operating Manual. Order No.: /00. MSAsafety.com

ACTIVE INFRARED BARRIER

21-light Remote Annunciator. Owner s Manual

Alarm Panel [ PRELIMINARY HARDWARE MANUAL ] USER MANUAL. v1.0a. May 7, 2008 D-OC-UM

Digital MFC software V1.10

Instruction Manual Model Backup Switch, 1 for 8

SC-F3G User Manual 1.0

User manual for CPR32-NET network controller

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

IRIS Touch Firmware Enhancements and Additions from Version to Version

C&K Software What s New. Commander II Version 3.0 Monitor II Version 3.0 Satellite II Version 1.0

Ambient Temperature/ Relative Humidity & Dew Point Temperature Sensors to USB Output. Model LFS108B

ECO N DATE DESCRIPTION OF CHANGE CHG

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

Tebis application software

READ AND SAVE THESE INSTRUCTIONS

600 Range Dialer Installation Manual. Version 1.0

NGC-UIT2 MODBUS PROTOCOL INTERFACE MAPPING FOR NGC-30 SYSTEMS. Firmware versions up to V2.0.X

CONTROL AND INDICATOR MODULE. Potok-BKI INSTRUCTION MANUAL

AK-CS On Board Guide

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Installer Manual KNX Touchscreen Thermostat

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

Metasys Integrator Vilter Application

Series Digital Controller Instruction Sheet

SCAN200E USER S MANUAL

Interface Module RS232/485. INTERFACE MODULE RS232/485 Instruction Manual 03-INT-02-17

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

USER'S MANUAL. Real Time Color Quad Processor. High Resolution, Broadcast Quality. Playback Zoom Function. RS232 Remote Control

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

FST DFS Notifier Onyx 640

AIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)

Database for CTS6000 MODBUS

FieldServer FS Secutron

ocbridge Plus SPECIFICATION 3. COMPONENTS Wireless sensors receiver, battery СR2032, manual, instalation CD.

Intelligent addressable fire alarm control panel

Guide for the integration with supervision systems FIRE DETECTION AND EXTINGUISHANT SYSTEMS GUIDE FOR INTEGRATION WITH SUPERVISION SYSTEMS

Fire control panel detect 3004 plus and accessories

EverAccess. User Manual. Volume

Connections, displays and operating elements C D E G H. Installing the control unit

80 CHANNELS WIRELESS RECEIVER WITH LCD DISPLAY M1.1.1-Hx.x-F1.1-ENG [AN] [SPV] MADE IN ITALY INSTALLATION AND USE MANUAL

Manual GPRS Data Logger PCE-GPRS 2

JA-63 Profi User manual

3 User s settings. 3.3 Internal clock setting

with internal sensor (channel 1) with an external sensor (channel 2) A-Editor software, Professional AK20 version (not for version AK4)

SECTION Process and Immersion Turbidity and Total Suspended Solids Sensor

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

T4000 Security Communicator

Simplex Panel Interface Guide

Interfacing Paging Systems

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV

FIRECLASS Networking. Addressable Fire Alarm Control Panels From Software version 21. Product Application and Design Information FC-A-FCNET-A

Gas Detection System TOX ALARM DG2000-Garage

Millennium Xtra. Millennium ATMA setup and configuration guide. May Millennium Group, Inc.

Model 135 Reference Document

Smoke Detector and Siren. Manual

D45. High performance door entry system CATALOGUE. A Group Brand

Paradox Integration Module Settings Guide

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

Transcription:

User manual version 1.3 KNXpar Management alarm control panels Paradox from KNX bus Powered from KNX bus Communication indication on KNX and with Paradox control panel DIN rail mount (1 module) Adjustable address on KNX with program KNXpar.exe (free) 1 www.foxtron.eu

RS232 KNX KNXpar is interface between alarm control panels Paradox and KNX bus. Using KNXpar it is possible to control the alarm control panel and changes in alarm control panel conditions are being sent automatically to the KNX. KNXpar does not need external power supplier - it is powered from KNX bus. Technical specification consumption (from KNX bus) 10 ma wires cross section (Paradox) 0,08 1,5 mm 2 wires cross section (KNX) 0,6 0,8 mm 2 Ingress protection degree (IP) IP20 ambient working temperature 0 50 C storage temperature -10 70 C weight 50 g Signalization RS232 RxD RS232 TxD KNX RxD KNX TxD message receiving from alarm control panel message sending to alarm control panel Message receiving on KNX addressed to KNXpar message sending on KNX RxD TxD KNXgw232 Communication with Paradox control panel With Paradox control panel communicates KNXpar by serial line RS232 on the module PRT3. Communication parameters Speed 19200 kbps Data bits number 8 bit Parity Stop bits number 1 bit 2 www.foxtron.eu

RS232 KNX Terminal connection GND Rx Tx Signal ground Data transmission Receiving data V+ 5-24V power supply of RS232 part in case of galvanic isolated buses RS232 Paradox KNX RxD TxD KNXgw232 1 V+ Rx Tx GND 1 2 3 4 5 6 7 8 9 Female wire preparation 5mm 6mm 0,6 0,8mm 2 0,08 1,5mm 2 Dimensions [mm] 90 45 17 17 58 10 3 www.foxtron.eu

Setup To setup KNXpar unit serves program KNXpar.exe. KNXpar is connected with computer by serial line, which is designated in normal usage for communication with Paradox alarm control panel. Before setup it is necessary in item COM to set the number of serial port of the computer to which is KNXpar connected. Bookmark "KNX address" Setup of physical address of the unit and group state address on KNX. Physical address is given by three numbers in the range of 0-15, 0-15 and 0-255 separated with period. In the picture is shown address 15.15.1 Upper part state address is given by two numbers in the range of 0-15 and 0-7 separated by slash. KNXpar takes 129 address on the KNX bus. Range of these address is given by the shift of Upper part address state. In the picture is shown 1/1 which means that used address will be 1/1/0 to 1/1/129. Location of individual states in this range will be described in the part List of read and controlled states. 4 www.foxtron.eu

Bookmark "Serial number, fw version" With Read buttons can be serial number and version read from KNXpar. Bookmark "firmware upgrade" To overwrite the firmware in KNXpar choose file with new firmware (*.hex) and with button write fw you start firmware overwrite. Update progress is shown. During the update do not disconnect the unit. 5 www.foxtron.eu

List of read and controlled states KNX index (x/x/index) State of Paradox alarm control panel Data direction DPT Communication KNXpar with PRT3Communication failure KNXpar with PRT3 Paradox KNX 1 (1b.) 0 0 Communication failure KNXpar with PRT3 1 Communication KNXpar with PRT3 OK 1 Communication PRT3 with control panel Paradox KNX 1 (1b.) 0 Communication failure PRT3 with DIGIPLEX 1 Communication PRT3 with DIGIPLEX OK State of subsystem Paradox KNX 7 (16b.) 15.b. 14.b. 13.b. 12.b. 11.b. 10.b. 9.b. 8.b. 7.b. 6.b. 5.b. 4.b. 3.b. 2.b. 1.b. 0.b. 2-9 1 strobe 1 in alarm 1 in programming 1 not ready 1 failure 1 zone in memory stay without delay stay force On the watch off Active is always exactly one of those five states 10-105 State of zone Paradox KNX 5 (8b.) 1 low battery 7.b. 6.b. 5.b. 4.b. 3.b. 2.b. 1.b. 0.b. 1 surveillance failure 1 fire alarm 1 in alarm Failure fire tamper opened closed Active is always exactly one of those four states Turn on the subsystem by code KNX Paradox 12 (32b.) 7.b. 6.b. 5.b. 4.Byte 4.b. 3.b. 2.b. 1.b. 0.b. 3.Byte 2.Byte 1.Byte 106-113 Stay w/o delay stay force common 1.password 2.password Code for turning on the subsystem 3.password 4.password 5.password 6.password Active is always exactly one for 4- password = 0 114-121 Turn on the subsystem by "key press" KNX Paradox 5 (8b.) 7.b. 6.b. 5.b. 4.b. 3.b. 2.b. 1.b. 0.b. stay w/o delay stay force common Active is always exactly one of those four states Turn off the subsystem by code KNX Paradox 12 (32b.) 4.Byte 3.Byte 2.Byte 1.Byte 122-129 1.password 2.password for 4- password = 0 Code for turning on the subsystem 3.password 4.password 5.password 6.password 6 www.foxtron.eu

In the table List of read and controlled states are listed all states which are being read from the alarm control panel and which are possible to write. In the column KNX index is shown the end part of the KNX address. E.g. for State of subsystem is listed 2-9. There are 8 subsystems in Paradox alarm control panel. If we set with software KNXpar.exe Upper part of group address to 1/1 as listed in chapter Setup then the first subsystem will have group address 1/1/2 and the second 1/1/2/ until the eight subsystem will have group address 1/1/9.Sent data will be data type DPT7 and will be 16 bits long as listed in column DPT. Example of communication: Turn on the subsystem by code common turn on, password 1234 On KNX will be send 4B / 32bit framework DPT12 (EIS11) with data: hex notation: 0x01001234 decimal notation: 16781876 7 www.foxtron.eu

tel: +420 274 772 527 e-mail: info@foxtron.cz web: www.foxtron.cz 8 www.foxtron.eu