NH 3. Dual Discharge Evaporator. Ammonia Industrial Applications 1-16 Tons MDAN

Similar documents
Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Compact CUBIC. Air cooler GSF. Highly efficient compact air cooler Optimal for commercial refrigeration. HFCs 1 55 kw

Air-Cooled Condensers

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax

MACH N-407 Heat Pump Air-Cooled Chiller

FX5 Series Explosion-Proof Electric Air Heaters

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:

MAC N-407 Air-Cooled Chiller

GHF CXGHF GGHF. The all-in-one solution for commercial refrigeration! Güntner Info. High efficiency wall/ceiling-mounted air cooler. 0.

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

Compact SLIM. Air cooler GASC. Air coolers in a flat design with forced draught fans Optimal for commercial cooling. HFCs, CO 2 0.

Güntner Info GHN. Vario Cubic for all refrigerants kw. Variable aircooler for industrial refrigerationw

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Advance Release September 2009

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

LOW PROFILE UNIT COOLER

Super-Flo Low Profile Unit Cooler

EHH SERIES DRAW THROUGH FAN COILS CFM

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:

PACKAGE AIR CONDITIONER

C13-Series Engineering Guide

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG:

KIC Air Curtains. Technical Guide

Stars Management JLT SUBMITTAL. EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series)

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:

Concealed Ducted Split Series R-407C MBH

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS

The ideal cooler at a competitive price KELVION TEC COMMERCIAL AIR COOLER

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

CENTRAL SPLIT UNIT UNIC

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

ELECTRICAL QUANTITY WEIGHT (LB)

PAJ3. Product Specifications

Portable Vertical Air-Conditioning and Heating Systems

LOW PROFILE UNIT COOLER

Installation, Operation, and Maintenance Information

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

Split System Cooling Product & Performance Data

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

VertiCool Aurora Engineering Guide

Installation, Operation, and Maintenance Information

ULTRA-SAFE Explosion-proof Duct Heaters

Evaporators 60HZ version

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

T P A 120 S 4 S N 1 Y

Vertical Upflow Horizontal Left Air Handlers

LH and GH/GL Series UNIT COOLERS. Technical Bulletin. Products that provide lasting solutions.

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil

MS Series UNIT COOLERS. Technical Bulletin: MSUC_005_ Products that provide lasting solutions.

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

AIR COOLED CONDENSERS

Modular Multi-position Air Handlers

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

CF1 ProVector Explosion-Proof Heaters

Innovative Engineering. Catalogue. Heat Exchangers. Evaporators. EKL1. Extra low temperature applications (60 Hz)

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_005_ Products that provide lasting solutions.

Unit Features & Benefits RQPM/RQRM Series

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½

Air-Cooled Condensers

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Cooling/Heat Pump Convertible Air Handlers

SMALL AIR COOLED CONDENSERS

Cooling/Heat Pump Convertible Air Handlers

High Heat COP. High/Low Stage

Cooling/Heat Pump Convertible Air Handlers

50TM TFF COMBINATION HEATING/COOLING UNITS

Modular Multi-position Air Handler

LOW RECIRCULATION RATE EVAPORATORS

VERSO Air Handling Units

Commercial High-Efficiency Condensing Units

High Profile Evaporator

SM/SV Series PRODUCT COOLERS. Technical Bulletin. Products that provide lasting solutions.

50TM COMBINATION HEATING/COOLING UNITS

Transcription:

NH 3 Dual Discharge Evaporator Ammonia Industrial Applications 1-16 Tons MDAN > > U s e d f o r S m a l l t o m e d i u m I n d u s t r i a l A m m o n i a a p p l i c a t i o n s Manufactured with Stainless steel tubes.

The Global Leader In Heat Exchange Technology With seven decades of experience and commitment to total client satisfaction, Guntner has earned a reputation as the global leader in heat exchange technology. Supported by the best R&D engineers in the business, cutting-edge technology, and eight manufacturing facilities around the world, Guntner continues to break new ground in the demanding market of finned heat exchangers for industrial refrigeration, HVAC, and process cooling applications. Our high standards and dedication to society and the environment around us have earned us the respect of the industry, and the privilege of long-term relationships with our customers around the world. keep(s) your quality keep(s) your quality. www.guntnerus.com

The Guntner Product Calculator MPC With the Guntner product calculator MPC, we are able to offer you more than just an overview of prices or the complete product range. This thermodynamic selection program enables you to calculate your own tailored selections based on precise and actual thermodynamics rather than factors or multipliers. A team of experts stand by to guide you through the selection process. Guntner Product Calculator The program can be updated via the internet ensuring that you always have the most exact and precise information for proper selection. We recommend using Guntner s Product Calculator for exact thermodynamic calculations. Varying conditions such as refrigerants, humidity levels and material combinations are all taken into account by the software to most accurately select products to fit your specific needs. > > calculations made easy with our precise MPC software www.guntnerus.com keep(s) your quality. 1

Standard Features of Construction Casing: The casing is corrosion resistant Aluminum (AIMg3) and seawater resistant up to fan diameter 20 (500 mm). From fan diameter 26 (650 mm) and larger, the casing is treated and painted corrosion resistant galvanized steel. All casings are powder coated - color RAL 9003 (Signal White) and suitable for all stringent food industry applications. Construction detail takes accessibility into account and does not allow for tight spots. All parts are easily accessible for service and cleaning purposes. Fan orifices are optimized by the manufacturer to ensure maximum efficiency, air throw and airflow. All fans are individually compartmented within complete tube sheets. All hangers and fittings used for construction and assembly are manufactured from stainless steel 304. Products have easily removable side panels for access to internal and electrical components. Tray: All models have corrosion resistant light weight Aluminum (AlMg3) and are seawater resistant. Trays are powder coated color RAL 9003 (Signal White). All trays are our unique fold down type and can be either folded down or completely removed, if required, for for cleaning purposes. The sloped design of the tray ensures maximum and efficient drainage during defrost cycle. Drain outlet connection can be either 2 x 1 1/4 NPT or 2 x 3/4 NPT. 2 keep(s) your quality. www.guntnerus.com

Tube: All tubing, headers and connections are manufactured from the highest quality 304 stainless steel 5/8 (15mm) tubing. Parallel, in-line, 1.969 x 1.969 (50 x 50mm) allows the reduced air-side pressure to drop through the coil. Tubes are mechanically expanded to ensure mechanical bonding coupled with the best heat transfer efficiency ratio from fin to tube. Our proven floating coil with support tubes does not permit the refrigerant carrying tubes to come into contact with the tube/end plates, and eliminates the risk of tube failure at the tube end plates. All coils are pressure tested to 450 psig with dry air under water, and shipped with a holding charge. Fins: Aluminum fins with a corrugated pattern provide enhanced air turbulence, guaranteeing contact with all surface areas within the coil bundle. 100% drawn die formed finned collars are standard and result in accurate fin spacings of 6.3, 3.6 and 2.5 FPI (4, 7 and 10 mm). All fins are manufactured with a continuous fin sheet in order to reduce the risk of frost build up, air-side pressure drops, dust, dirt and bacteria - simplifying any cleaning procedure. Coil Circuiting: Each unit is specifically circuited to optimize coil performance and capacity with a low pressure drop (consult with selection software to obtain best circuiting for each application). Horizontal headers are standard for re-circulated and flooded applications. Coil connections are manufactured from 304 stainless steel in accordance with ASME B31.5 requirements. Fans & Motors: External rotor axial fans are standard for the entire range. Internal motor thermo contacts must be incorporated into the control circuit for motor protection. All motors are aluminum die cast and of the highest efficiency. They are also maintenance free with guaranteed long life and low noise levels. Fan guards are galvanized steel and PVC coated. All motors are of the blow through type. Standard voltages are 230V and 460V for 3~ / 60Hz applications and 400V for 3~ / 50Hz applications. Defrost: Standard defrost options for all units include air, electric or hot gas. Electric heater elements are stainless steel sheathed and fit directly into tubes within the coil bundle to provide enhanced heat transfer during the defrost cycle. Elements are held in place with clips to prevent them from moving during transport or operation. Electrical: All fan motors are factory wired to the junction box with single point connection. However, factory installed jumpers can be removed for individual / capacity control. All heater wiring is terminated within a junction box for quick and simple field connections. When heater circuit amperages exceed 48 amps, multiple circuits are provided in order to comply with the NEC limitation of 48 amps per circuit. Delivery & Packing: All units are crated and shipped in a position to help facilitate installation. www.guntnerus.com keep(s) your quality. 3

Optional Features Construction Materials The entire casing unit, tube sheets and tray manufactured with either 304 or 316 stainless steel. Insulated pan (required by the USDA for certain food / processing applications). Insulated fan panel. Epoxy coated aluminum or stainless steel (304 or 316) fins. Units are supplied standard with carbon steel black pipe connections but can be ordered with either stainless steel pipe, flanges (ANSI B16.5) or carbon steel threaded connection (ASME B1.20). Re-heat coils separated from the cooling coil by means of an air gap. Foot mounts for floor mounting. For unit operation below -40ºF consult sales office. Fans and Motors Oversize motors for higher face velocities and / or external pressures. Defrost Options The use of fan ring heaters is recommended for low temperature applications available in 230 and 460V). For electric defrost - defrost termination and fan delay thermostat factory fitted. Heater limit thermostat fitted and pre-wired. Factory installed check valve between tray and coil for hot gas defrost. Electrical No wiring. All motors wired to common / individual non-fused disconnect. All motors wired to common fused disconnect with thermal protection for each motor. All motors wired to fused disconnect with single starter and thermal protection for each motor. Various wiring options are available please consult with factory for an alternative to suit your specific requirements. Two speed, high efficiency or explosion proof motors. Draw through option on some models (down blow). 4 keep(s) your quality. www.guntnerus.com

Evaporator MDAN MDAN 051 C/ 1 7 -A L Product Line Voltage X 1/230/60 J 3/400/60 l 3/460/60 s 3/400/50 U 3/230/60 Fan Diameter 16 041 18 046 20 051 26 066 A E H Defrost AIR ELECTRIC HOT GAS Rows DeeP C/ No. of Fans 1 Fin Spacing 4 4mm - 6.3 PPI 7 7mm - 3.6 PPI 10 10mm - 2.5 PPI Unit Model Fan Fan Diameter Fan Motors- Electrical Specifications Motor Ratings @3Ph/60Hz (ea.) Sound Power Level Guntner mm Voltage HP rpm FLA db (A) Spare Part No. 041 400 16 046 450 18 051 500 20 066 650 26 460 1/4 1490 0.58 73.0 230 1/4 1400 0.9 72.0 460 1/4 1390 0.62 73.0 230 1/4 1270 1.1 70.5 460 1/2 1350 0.96 75.5 230 1/3 1210 1.65 73.0 460 1/2 860 1.25 77.0 230 1/2 790 2.2 74.8 VT0354U VT01174U VT01176U VT01178U www.guntnerus.com keep(s) your quality. 5

Performance Data: All Models Model No. MDAN COil Wet Frosted Surface Area Tube Volume Fin Spacing Btu/hr/ F TD Btu/hr/ F TD ft 2 ft 3 fpi 1 FAN 041A/14-1,732 1,219 372 0.24 046A/14-2,474 1,664 497 0.29 051C/14-4,891 3,190 931 0.53 066C/14-7,356 5,541 1490 0.82 041C/17-1,817 1,386 329 0.35 046C/17-2,323 1,908 439 0.44 051C/17-3,123 2,350 548 0.53 066C/17-4,681 3,852 877 0.82 066D/17-6,665 4,997 1169 1.10 041C/110-1,483 1,222 237 0.35 046C/110-2,005 1,555 316 0.44 051C/110-2,549 2,122 395 0.53 066C/110-4,027 3,157 631 0.82 066D/110-5,440 4,526 842 1.10 2 FAN 041A/24-3,468 2,444 745 0.41 046A/24-4,956 3,333 993 0.53 051C/24-9,447 6,989 1862 0.97 6.3 3.6 2.5 6.3 066C/24-15,148 11,100 2979 1.53 041C/27-3,638 2,779 658 0.62 046C/27-4,905 3,818 877 0.79 051C/27-6,249 4,970 1096 0.97 066C/27-9,873 7,971 1754 1.53 066D/27-13,339 10,001 2339 2.04 041C/210-2,969 2,449 474 0.62 046C/210-4,014 3,114 631 0.79 051C/210-5,099 4,249 789 0.97 066C/210-8,041 6,724 1263 1.53 066D/210-10,878 9,059 1684 2.04 3.6 2.5 3 FAN 041A/34-5,225 3,847 1117 0.59 046A/34-7,087 5,403 1490 0.77 6.3 051C/34-14,714 9,584 2793 1.41 066C/34-22,074 17,237 4469 2.24 041C/37-5,220 4,282 987 0.88 046C/37-7,472 5,727 1316 1.15 051C/37-9,377 7,058 1645 1.41 3.6 066C/37-15,038 11,558 2631 2.24 066D/37-20,918 15,482 3508 2.98 041C/310-4,462 3,488 710 0.88 046C/310-6,104 4,893 947 1.15 051C/310-7,870 6,374 1184 1.41 2.5 066C/310-12,252 10,122 1894 2.24 066D/310-16,372 12,745 2526 2.98 6 keep(s) your quality. www.guntnerus.com

Model No. MDAN Air Flow Sound Pressure Level Air Throw Sound Pressure Level Electric Defrost Total Coil Tray Amp Draws @ 3/460/60 @ 3/230/60 @3/460 @3/230 cfm fpm cfm fpm ft db (a) kw W W A A 041A/14-1,913 496 1,795 466 2x20 58 3.4 1,800 1600 4.3 8.5 046A/14-2,737 532 2,531 493 2x26 58 5 3,000 2000 6.3 12.6 051C/14-3,502 545 3,178 495 2x33 60 6.2 3,800 2400 7.8 15.6 066C/14-5,150 501 4,738 462 2x36 61 9.8 6,600 3200 12.3 24.6 041C/17-1,825 473 1,677 436 2x20 58 4 2,400 1600 5.0 10.0 046C/17-2,649 515 2,472 481 2x26 58 5 3,000 2000 6.3 12.6 051C/17-3,649 568 3,296 513 2x33 60 6.2 3,800 2400 7.8 15.6 066C/17-5,415 527 4,974 484 2x39 61 9.8 6,600 3200 12.3 24.6 066D/17-4,974 484 4,561 444 2x36 61 12 8,800 3200 15.1 30.1 041C/110-1,854 481 1,707 443 2x20 58 4 2,400 1600 5.0 10.0 046C/110-2,678 521 2,501 487 2x26 58 5 3,000 2000 6.3 12.6 051C/110-3,649 568 3,325 518 2x33 60 6.2 3,800 2400 7.8 15.6 066C/110-5,533 538 5,062 493 2x39 61 9.8 6,600 3200 12.3 24.6 066D/110-5,062 492 4,650 453 2x33 61 12 8,800 3200 15.1 30.1 041A/24-3,826 497 3,590 466 2x26 61 5.9 3,300 2600 7.4 14.8 046A/24-5,474 533 5,062 492 2x36 60 9.2 6,000 3200 11.5 23.1 051C/24-7,004 545 6,357 495 2x46 63 11.4 7,200 4200 14.3 28.6 066C/24-10,300 501 9,476 461 2x49 63 18.4 13,200 5200 23.1 46.2 041C/27-3,649 474 3,355 435 2x26 61 7 4,400 2600 8.8 17.6 046C/27-5,297 516 4,944 481 2x36 60 9.2 6,000 3200 11.5 23.1 051C/27-7,298 568 6,592 513 2x46 63 11.4 7,200 4200 14.3 28.6 066C/27-10,830 527 9,947 484 2x52 63 18.4 13,200 5200 23.1 46.2 066D/27-9,947 484 9,123 444 2x49 63 22.8 17,600 5200 28.6 57.2 041C/210-3,708 481 3,414 443 2x29 61 7 4,400 2600 8.8 17.6 046C/210-5,356 521 5,003 487 2x39 60 9.2 6,000 3200 11.5 23.1 051C/210-7,298 568 6,651 518 2x46 63 11.4 7,200 4200 14.3 28.6 066C/210-11,065 538 10,124 493 2x52 63 18.4 13,200 5200 23.1 46.2 066D/210-10,124 493 9,300 453 2x52 63 22.8 17,600 5200 28.6 57.2 041A/34-5,739 496 9,150 466 2x33 62 8.9 5,100 3800 11.2 22.3 046A/34-8,211 533 12,900 492 2x42 62 13.6 8,800 4800 17.1 34.1 051C/34-10,506 545 16,200 495 2x56 64 17 10,800 6200 21.3 42.7 066C/34-15,450 501 24,150 462 2x59 64 26.8 19,200 7600 33.6 67.3 041C/37-5,474 473 8,550 435 2x33 62 10.6 6,800 3800 13.3 26.6 046C/37-7,946 515 12,600 481 2x46 62 13.6 8,800 4800 17.1 34.1 051C/37-10,948 568 16,800 513 2x56 64 17 10,800 6200 21.3 42.7 066C/37-16,245 527 25,350 484 2x65 64 26.8 19,200 7600 33.6 67.3 066D/37-14,921 484 23,250 444 2x62 64 33.2 25,600 7600 41.7 83.3 041C/310-5,562 481 8,700 443 2x36 62 10.6 6,800 3800 13.3 26.6 046C/310-8,034 521 12,750 487 2x46 62 13.6 8,800 4800 17.1 34.1 051C/310-10,948 568 16,950 518 2x56 64 17 10,800 6200 21.3 42.7 066C/310-16,598 538 25,800 493 2x65 64 26.8 19,200 7600 33.6 67.3 066D/310-15,185 492 23,700 453 2x62 64 33.2 25,600 7600 41.7 83.3 1 FAN 2 FAN 3 FAN * Units with heater amp draws greater than 48 amps will be supplied with multiple circuits- as required by the NEC www.guntnerus.com keep(s) your quality. 7

Dimensions: All Models Model No. MDAN L UNIT DIMENSIONS CONNECTIONS *With Water Defrost Option Add 4 Inches to H. Refrigerant Hot Gas Drain Net Weight B H* E F in NPS out NPS in NPS NPT lb 041A/14-39 3/8 61 5/8 17 11/16 23 5/8 59 7/16 1/4 1/4 1/2 3/4 146 046A/14-47 1/4 61 5/8 17 11/16 31 1/2 59 7/16 1/4 1/4 1/2 3/4 171 051C/14-55 1/8 61 5/8 17 11/16 39 3/8 59 7/16 3/4 3/4 1/2 3/4 227 066C/14-72 7/8 76 5/8 20 47 1/4 74 1/2 1 1 1/4 1/2 1 1/4 437 041C/17-39 3/8 61 5/8 17 11/16 23 5/8 59 7/16 1/4 1/4 1/2 3/4 149 046C/17-47 1/4 61 5/8 17 11/16 31 1/2 59 7/16 1/4 1/4 1/2 3/4 175 051C/17-55 1/8 61 5/8 17 11/16 39 3/8 59 7/16 3/4 3/4 1/2 3/4 197 066C/17-72 7/8 76 5/8 20 47 1/4 74 1/2 3/4 3/4 1/2 1 1/4 392 066D/17-72 7/8 76 5/8 20 47 1/4 74 1/2 1 1 1/4 1/2 1 1/4 431 041C/110-39 3/8 61 5/8 17 11/16 23 5/8 59 7/16 1/4 1/4 1/2 3/4 149 046C/110-47 1/4 61 5/8 17 11/16 31 1/2 59 7/16 1/4 1/4 1/2 3/4 174 051C/110-55 1/8 61 5/8 17 11/16 39 3/8 59 7/16 3/4 3/4 1/2 3/4 196 066C/110-72 7/8 76 5/8 20 47 1/4 74 1/2 3/4 3/4 1/2 1 1/4 391 066D/110-72 7/8 76 5/8 20 47 1/4 74 1/2 1 1 1/4 1/2 1 1/4 427 041A/24-63 61 5/8 17 11/16 23 5/8 59 7/16 3/4 3/4 1/2 3/4 240 046A/24-78 3/4 61 5/8 17 11/16 31 1/2 59 7/16 3/4 3/4 1/2 3/4 291 051C/24-97 5/8 61 5/8 17 11/16 39 3/8 59 7/16 1 1 1/4 1/2 3/4 417 066C/24-120 76 5/8 20 47 1/4 74 1/2 1 1 1/4 1/2 1 1/4 748 041C/27-63 61 5/8 17 11/16 23 5/8 59 7/16 3/4 3/4 1/2 3/4 249 046C/27-78 3/4 61 5/8 17 11/16 31 1/2 59 7/16 3/4 3/4 1/2 3/4 303 051C/27-97 5/8 61 5/8 17 11/16 39 3/8 59 7/16 1 1 1/4 1/2 3/4 355 066C/27-120 76 5/8 20 47 1/4 74 1/2 1 1 1/4 1/2 1 1/4 648 066D/27-120 76 5/8 20 47 1/4 74 1/2 1 1 1/4 1/2 1 1/4 735 041C/210-63 61 5/8 17 11/16 23 5/8 59 7/16 3/4 3/4 1/2 3/4 249 046C/210-78 3/4 61 5/8 17 11/16 31 1/2 59 7/16 3/4 3/4 1/2 3/4 302 051C/210-97 5/8 61 5/8 17 11/16 39 3/8 59 7/16 1 1 1/4 1/2 3/4 354 066C/210-120 76 5/8 20 47 1/4 74 1/2 1 1 1/4 1/2 1 1/4 646 066D/210-120 76 5/8 20 47 1/4 74 1/2 1 1 1/4 1/2 1 1/4 732 1 FAN 2 FAN DrawingS for All models 8 keep(s) your quality. www.guntnerus.com

Model No. MDAN L UNIT DIMENSIONS CONNECTIONS *With Water Defrost Option Add 4 Inches to H. Refrigerant Hot Gas Drain Net Weight B H* E F in NPS out NPS in NPS NPT lb 041A/34-89 3/4 61 5/8 17 11/16 23 5/8 59 7/16 3/4 3/4 1/2 3/4 345 046A/34-113 1/2 61 5/8 17 11/16 31 1/2 59 7/16 1 1 1/4 1/2 1 1/4 428 051C/34-143 3/4 61 5/8 17 11/16 39 3/8 59 7/16 1 1 1/4 1/2 1 1/4 602 066C/34-167 3/8 76 5/8 20 47 1/4 74 1/2 1 1 1/4 1/2 1 1/4 1074 041C/37-89 3/4 61 5/8 17 11/16 23 5/8 59 7/16 3/4 3/4 1/2 3/4 351 046C/37-113 1/2 61 5/8 17 11/16 31 1/2 59 7/16 1 1 1/4 1/2 1 1/4 435 051C/37-143 3/4 61 5/8 17 11/16 39 3/8 59 7/16 1 1 1/4 1/2 1 1/4 513 066C/37-167 3/8 76 5/8 20 47 1/4 74 1/2 1 1 1/4 1/2 1 1/4 920 066D/37-167 3/8 76 5/8 20 47 1/4 74 1/2 1 1 1/4 1/2 1 1/4 1044 041C/310-89 3/4 61 5/8 17 11/16 23 5/8 59 7/16 3/4 3/4 1/2 3/4 350 046C/310-113 1/2 61 5/8 17 11/16 31 1/2 59 7/16 1 1 1/4 1/2 1 1/4 434 051C/310-143 3/4 61 5/8 17 11/16 39 3/8 59 7/16 1 1 1/4 1/2 1 1/4 511 066C/310-167 3/8 76 5/8 20 47 1/4 74 1/2 1 1 1/4 1/2 1 1/4 912 066D/310-167 3/8 76 5/8 20 47 1/4 74 1/2 1 1 1/4 1/2 1 1/4 1047 3 FAN DrawingS for All models www.guntnerus.com keep(s) your quality. 9

keep(s) your quality. www.guntnerus.com