WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax

Similar documents
A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

LOW PROFILE UNIT COOLER

Super-Flo Low Profile Unit Cooler

Center Mount Unit Coolers

LOW PROFILE UNIT COOLER

MS Series UNIT COOLERS. Technical Bulletin: MSUC_005_ Products that provide lasting solutions.

Low Flow Unit Coolers

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_005_ Products that provide lasting solutions.

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_001_ Products that provide lasting solutions.

SM/SV Series PRODUCT COOLERS. Technical Bulletin. Products that provide lasting solutions.

High Profile Evaporator

Low Profile Unit Cooler. ECM Motors. All-Temp²B. Small to Medium Walk - Ins. Coolers & Freezer Applications. Now available with optional

Lo-Aire Unit Coolers. Technical Guide. bn-lftb May Models LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost.

Low Velocity Center Mount Unit Cooler. Technical Guide. Models LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost.

LOW PROFILE UNIT COOLER. Technical Guide. Models RLC Air Defrost ELC/EFC Electric Defrost GLC Hot Gas Defrost. CH-LOPTB May,

Low Profile Unit Coolers

Low Profile Unit Coolers

LH and GH/GL Series UNIT COOLERS. Technical Bulletin. Products that provide lasting solutions.

MACH N-407 Heat Pump Air-Cooled Chiller

KTL Two-Way Low Profile Evaporators

Refrigeration Systems by. Cool You Can Count On!

PRODUCT. TWB Two-Way Air Defrost Unit Coolers PRODUCT DATA & INSTALLATION. High Temperature (35 o F / 1.7 o C or Higher) Applications

CWA4 Chilled & Hot Water Fan Coil

CONDENSING UNITS-AIR SUBMITTED BY : Poppy Hudson PROJECT : Brooks Landing REV DATE : 07 Dec 2017 ORDER # : A00

Installation, Operation, and Maintenance Information

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

TABLE OF CONTENTS. FCV Nomenclature 3. FCV Features & Construction 4. FCV Engineering Specifications 5. FCV Fan/Coil Data 6

Reach-In Unit Coolers. Technical Guide. Models TA TL C VA BBM BBL KMK RAMK BTO U. LK-RITB June

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

KR Series COMPACT UNIT COOLERS. Technical Bulletin: KRUC_005_ Products that provide lasting solutions.

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_002_ Products that provide lasting solutions.

Product Chillers A P P L I C AT I O N S

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

MAC N-407 Air-Cooled Chiller

Page ` RLP R1. Supersedes all earlier versions LIST PRICES April, 2018

TLV Low Velocity Evaporators

NH 3. Dual Discharge Evaporator. Ammonia Industrial Applications 1-16 Tons MDAN

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

Reach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

1.1 This section applies to air handling units for HVAC Systems.

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

STC Series Twin Unit Coolers (E329630_A)

Compak Unit Coolers. LCA - Air Defrost LCE - Electric Defrost LCH - Hot Gas Defrost. Bulletin LC-03A August 2004 (Replaces LC-03 3/03)

Unit Dimension. Unit Nomenclature DEHUMIDIFIER NOMENCLATURE UNIT VOLTAGE: 2: 240/1/60 5: /3/60 9: 480/3/60 8: 600/3/60

Industrial Unit Coolers

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

High Heat COP. High/Low Stage

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

AIR HANDLER SPECIFICATION

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

BTL Two-Way Low Profile Evaporators

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

FX5 Series Explosion-Proof Electric Air Heaters

ThermoSaver TM Hot Gas Defrost System

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

T P A 120 S 4 S N 1 Y

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

KTL Two-Way Low Profile Unit Coolers

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

LIST PRICES SEE THE BACK COVER FOR "CONDITIONS OF SALE AND WARRANTY"

SECTION REFRIGERATION EQUIPMENT. A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories.

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Unit Coolers Evaporator & Condenser Coils Aluminum Extrusion Heat Transfer Products

TECHNICAL SPECIFICATIONS

Page ` RLP A. Supersedes all earlier versions LIST PRICES Prices effective 7/2/18

Slim Contour Unit Cooler

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

Advance Release September 2009

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

13 GEP A L P - 1 A

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS

IOM 410. Installation Operation Maintenance Information. UNIT COOLERS Super-Flo (SD Models) Easy-Flo (EF Models) Table of Contents

Concealed Ducted Split Series R-407C MBH

RGE 13 A T - 1 A

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

BN-HGDTB June Replaces BN-HGDTB, March Mohave. Technical Guide

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps

KAP Horizontal Product Coolers

Reach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5

Levitor II. AIR-COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS (Available for Fluid Cooler Applications)

MERIT Series R-410A - Upflow / Horizontal

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

SMALL AIR COOLED CONDENSERS

Microchannel REMOTE AIR COOLED CONDENSER. Technical Bulletin: MXCC_004_ Products that provide lasting solutions.

Transcription:

WIBR SERIES Unit Coolers - Technical Catalog 4492 Hunt St - Pryor, OK 74361-918.825.7222 - Fax 800.264.5329 - www.century-refrigeration.com

Features/Applications Century Refrigeration s WIBR Series Unit Coolers are designed for in between the rails commercial and industrial freezer and cooler applications at or above -30 F. The WIBR Series Unit Coolers utilize a configuration of fans, motor horsepower, coil circuiting, and blade configuration to meet your specific project needs. The following features are standard on each WIBR Series Unit Cooler: 24 models from 18,000 to 185,000 BTUH Fin spacing available at 4 or 6 FPI Aluminum plate fin coil at 4, 6, or 8 rows Insulated drain pan Adjustable defrost termination/fan delay on electric and hot gas defrost models Available in air, electric, or hot gas defrost configurations Top air discharge arrangement with V air diffuser Standard mounting configuration is ceiling hung 28 diameter fan blades with 1, 2, 3, or 4 fans 1/2 HP fan motors with 115/60/1, 208-230/60/1, 208-230/60/3, and 460/60/3 voltages In Electric Defrost and Hot Gas Defrost models, condensate drain lines must be adequately heat traced in rooms below freezing. Support piping adequately with suction line P traps at unit. Locate liquid line solenoid close to TXV. Use externally equalized TXV. Available Options Units circuited for water or glycol solutions Mounted non-fused fan motor disconnect switch standard with auxillary contact for liquid solenoid Mounted non-fused heater disconnect switch Mounted or shipped loosetxv Mounted or shipped loose electronic expansion valves Various fin materials, coatings and casing arrangements available for corrosive atmosphere applications Stainless steel hardware, fasteners, and/or housings Motor and fan blade combinations for hazardous duty applications ECM or VFD compatible motors can be supplied with overloads and single-point wiring connection ECM motors for 115-208-230/1 phase applications to comply with federal standards. Room thermostat, mechanical or electronic (shipped loose) Nomenclature MODEL KEY Series Fins/Inch Number of Fans Refrigerant 4 - R-404a 7 - R-507 WIBR 424-229 A Defrost A - Air E - Electric HG - Hot Gas BTUH 10 TD WHEN ORDERING PLEASE SPECIFY: Complete Model Number Refrigerant Room Temperature Saturated Suction Temperature Electrical Characteristic - Motors (Voltage/Phase) - Heaters (Voltage/Phase) - Control Voltage Defrost Type Accessories

Construction Cabinet Cabinets are made of heavy-gauge, rust-proof, smooth finish aluminum housing. All hardware is corrosion resistant. Full die-formed venturies minimize noise with maximum air throw. Fan guards are heavy-gauge wire basket-type coated for corrosion protection. Coil Coils are copper tube, full-collared die-formed aluminum plate fin and tube sheets. Tubes are mechanically expanded for maximum heat transfer. Coils are leak tested at 350 PSIG under water. Solder distributors have removable nozzles. Each nozzle is sized for the specified refrigerant and temperature range. All coils use an external equalized expansion valve. Fans Fans are 28 inch fiberglass reinforced polypropylene blades with steel hubs that are statically and dynamically balanced for smooth operation. They are selected for maximum air throw. Motors Motors are permanently lubricated for reduced maintenance time and costs and suitable for low temperature applications. Motors are heavy duty, high efficiency, full ball bearing and have internal thermal overloads to protect against over-amperage and overheating. Motors are suitable for single-point group fusing. Fan motors are pre-wired to terminal blocks. Refrigerants Coils are designed for use with many refrigerants. Defrost Electric Defrost models include pre-wired terminal blocks and low-watt density heaters that are housed internal to the coil for a rapid and efficient defrost. Lower coil heaters and drain pan heaters help provide fast and reliable condensate drainage. Standard operating control includes an adjustable defrost termination with fan delay. Hot Gas Defrost models include an auxiliary side port connection on the distributor, insulated drain pan with a hot gas loop in the pan, and a check valve shipped loose. An adjustable defrost termination/fan delay switch is also provided with this option for temperature termination of the defrost period. Mounting Century offers ceiling mounting for each WIBR Series model.

WIBR Model CFM FPM Capacity Evaporating Temperature -40 F -30 F -20 F -10 F 0 F +10 F +20 F +30 F +40 F 410-270 6,580 627 17,961 20,173 21,848 23,163 24,291 25,397 26,642 28,181 30,165 410-360 6,040 575 23,949 26,897 29,130 30,884 32,388 33,863 35,523 37,575 40,220 410-410 5,500 524 27,275 30,633 33,176 35,174 36,886 38,566 40,457 42,794 45,806 420-570 13,400 596 37,918 42,586 46,122 48,899 51,280 53,615 56,244 59,493 63,680 420-750 12,490 555 49,892 56,035 60,687 64,341 67,474 70,546 74,005 78,281 83,790 420-860 11,450 509 57,210 64,253 69,588 73,778 77,370 80,893 84,859 89,762 96,079 430-790 19,470 649 52,553 59,023 63,924 67,773 71,072 74,309 77,952 82,456 88,259 430-1040 17,650 588 69,184 77,701 84,152 89,219 93,563 97,824 102,620 108,549 116,188 430-1190 16,190 540 79,162 88,908 96,290 102,088 107,058 111,933 117,420 124,205 132,946 440-1050 25,960 649 69,849 78,449 84,962 90,078 94,463 98,765 103,607 109,593 117,306 440-1380 23,540 589 91,802 103,104 111,664 118,388 124,152 129,805 136,169 144,037 154,173 440-1590 21,590 540 105,771 118,793 128,656 136,403 143,044 149,558 156,890 165,955 177,634 610-320 5,990 570 21,288 23,909 25,894 27,453 28,789 30,100 31,576 33,400 35,751 610-390 5,390 513 25,944 29,138 31,557 33,457 35,086 36,684 38,482 40,706 43,571 610-430 4,830 460 28,605 32,127 34,794 36,889 38,686 40,447 42,430 44,882 48,040 620-670 12,290 546 44,570 50,057 54,213 57,478 60,276 63,021 66,111 69,930 74,852 620-820 11,120 494 54,549 61,265 66,352 70,347 73,772 77,131 80,912 85,587 91,611 620-900 10,010 445 59,871 67,242 72,825 77,210 80,969 84,656 88,806 93,937 100,548 630-930 17,500 583 61,866 69,483 75,252 79,783 83,667 87,477 91,766 97,068 103,899 630-1130 15,690 523 75,171 84,425 91,435 96,940 101,660 106,289 111,500 117,943 126,243 630-1240 14,000 467 82,488 92,644 100,336 106,377 111,556 116,636 122,354 129,424 138,532 640-1260 23,330 583 83,819 94,138 101,954 108,093 113,356 118,517 124,328 131,511 140,766 640-1510 20,920 523 100,450 112,817 122,183 129,540 135,847 142,033 148,996 157,605 168,697 640-1660 18,670 467 110,428 124,023 134,321 142,408 149,342 156,142 163,797 173,261 185,455 Capacity based on 10 F TD

WIBR Model Qty. HP 4 86 87 88 90 91 93 95 96 98 99 100 6 101 102 Fan Motor Data 115/1 208-230/1 Amps 1 208-230/3 Electrical/Specifications Defrost Heater Data Amps 2 Watts 460/3 208-230/3 460/3 Connections (in.) Approx. Refrig. Charge (lbs.) 3 Ship Weight (lbs.) Operating Weight (lbs.) 410-270 1 1/2 8.5 5.3 2 1 8,048 22 12 1/2 1 1/8 7/8 14 388 278 410-360 1 1/2 8.5 5.3 2 1 9,616 25 13 5/8 1 1/8 7/8 21 437 335 410-410 1 1/2 8.5 5.3 2 1 11,184 29 14 7/8 1 1/8 7/8 28 489 395 420-570 2 1/2 17.0 10.6 4 2 16,472 44 23 7/8 1 3/8 1 1/8 29 750 520 420-750 2 1/2 17.0 10.6 4 2 19,750 50 25 1 1/8 1 3/8 1 1/8 43 856 642 420-860 2 1/2 17.0 10.6 4 2 23,028 58 29 1 3/8 1 3/8 1 1/8 58 956 760 430-790 3 1/2 25.5* 15.9 6 3 21,180 56 30 1 1/8 1 3/8 1 1/8 38 996 704 430-1040 3 1/2 25.5* 15.9 6 3 25,350 64 32 1 3/8 1 5/8 1 1/8 58 1,137 868 430-1190 3 1/2 25.5* 15.9 6 3 29,550 75 38 1 3/8 1 5/8 1 1/8 76 1,268 1,020 440-1050 4 1/2 34* 21.2 8 4 24,464 64 34 1 3/8 1 5/8 1 3/8 33 1,266 896 440-1380 4 1/2 34* 21.2 8 4 29,164 75 38 1 3/8 2 1/8 1 3/8 76 1,452 1,133 440-1590 4 1/2 34* 21.2 8 4 33,864 85 43 1 5/8 2 1/8 1 3/8 101 1,628 1,338 610-320 1 1/2 8.5 5.3 2 1 8,048 22 12 1/2 1 1/8 7/8 14 401 291 610-390 1 1/2 8.5 5.3 2 1 9,616 25 13 5/8 1 1/8 7/8 21 459 357 610-430 1 1/2 8.5 5.3 2 1 11,184 29 14 7/8 1 1/8 7/8 28 518 424 620-670 2 1/2 17.0 10.6 4 2 16,472 44 23 1 1/8 1 3/8 1 1/8 29 786 556 620-820 2 1/2 17.0 10.6 4 2 19,750 50 25 1 1/8 1 3/8 1 1/8 43 902 688 620-900 2 1/2 17.0 10.6 4 2 23,028 58 30 1 3/8 1 5/8 1 1/8 58 1,017 821 630-930 3 1/2 25.5* 15.9 6 3 21,180 56 30 1 1/8 1 5/8 1 1/8 38 1,037 744 630-1130 3 1/2 25.5* 15.9 6 3 25,350 64 32 1 3/8 1 5/8 1 1/8 58 1,197 928 630-1240 3 1/2 25.5* 15.9 6 3 29,550 75 38 1 3/8 1 5/8 1 1/8 76 1,347 1,100 640-1260 4 1/2 34* 21.2 8 4 24,464 64 34 1 3/8 1 5/8 1 3/8 33 1,320 950 640-1510 4 1/2 34* 21.2 8 4 29,164 75 38 1 3/8 2 1/8 1 3/8 76 1,532 1,212 640-1660 4 1/2 34* 21.2 8 4 33,864 85 43 1 3/8 2 1/8 1 3/8 101 1,731 1,442 Liquid Suction Hot Gas *- Requires two electrical circuits. 1 - The fan and motor combinations for single phase motors pull less amperage than actual motor nameplate. a.115v 2.7 amps b.208v / 230V 1.9 amps 2 - Value for heater amps is total for unit. Multiple circuits are required to keep circuits within NEC guidelines of 48 amps. 3 - Refrigerant charge is applicable for types R404a and R507. Contact factory for other refrigerant types.

Dimensions

Dimensions WIBR Model 1 Fan 2 Fans 3 Fans 4 Fans 410-270 420-570 430-790 440-1050 610-320 620-670 630-930 640-1260 410-360 420-750 430-1040 440-1380 610-390 620-820 630-1130 640-1510 410-410 420-860 430-1190 440-1590 610-430 620-900 630-1240 640-1660 Height (H) 33" 35 3/4" 38 1/4" * - 5/8 diameter unit mounting holes 1 - All dimensions +/- 1/2

4492 Hunt St - Pryor, OK 74361 - (918) 825-7222 - Fax (800) 264-5329 www.century-refrigeration.com We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacement for equipment previously sold or shipped. Bulletin# C-TC-WIBR-0118