SOUNDER CONTROL MODULE SCM-AS4

Similar documents
NAM-AS3 LOOP POWERED INPUT MODULE INSTALLATION & TECHNICAL MANUAL

CONTENTS NBM-06 Bell (6") Page 1

Surveyor Envoy-MINI 4

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

OPERATION AND INSTALLATION MANUAL

Application, Installation, Operation & Maintenance Manual

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

evolution EV-H ANALOGUE ADDRESSABLE HEAT SENSOR INSTRUCTION MANUAL LPCB REF: 041h/01&02 and 842c/03&04

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

EVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR. instruction manual. evolution EVC-P Conventional Photoelectric Smoke Detector

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

System 800 Addressable Fire Detection & Alarm System

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Input/Output Modules Data Sheet

Written by: A.C. Amended by G.G. Checked by: JBJ/PB Approved by:jbj

An introduction to... Sigma

ANALOGUE ADDRESSABLE FIRE CONTROL PANELS FIREQUEST FAMILY. Section 6 Trouble Shooting Issue 1.1

Installation, Operating and Maintenance Manual

EXTINGUISHING AGENT RELEASE MODULE

Excel-EN Conventional Fire Control Panel

Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)

Evolution Analogue Addressable Fire System

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

Saffire User & Installation Manual. IMPORTANT This manual should be left with the panel after installation.

Intelligent Security & Fire Ltd

Reliably Advanced Extinguishing Control

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

installation & maintenance manual LPCB APPROVED CFP 2/4/8 ZONE FIRE ALARM CONTROL PANEL approved document no. DFU rev 5

Conventional Fire Detection

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

4100S. The operation and functions described in this manual are available from Software Version 4100S onwards.

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

Touch Screen 1 loop Addressable Fire Alarm Panel

Control Panel Engineering and Commissioning Instructions

Surveyor Excel. Fire Alarm Control Equipment Network version. Programming Manual MASTER MANUAL. VERSION 14.0 and Above

FIRE ALARM CONTROL PANEL. COMPLIES WITH EN54 part 2 & part 4 MEETS THE FUNCTIONAL REQUIREMENT OF BS:EN 5839 part 1 INSTALLATION MANUAL

The EN54 Part 2 & 4 Fire System

Intelligent Security & Fire Ltd

VoCALL - CFVCC5. Compact 5 Line Exchange Unit. Installation & Commissioning Manual

SECURIT 700L PLUS ENGINEERING MANUAL

FIREPRO INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL. Approved Document No. GLT Issue: 1. 8 Author: NRPJ Date: 7/ 3/201 4

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

Interface Modules for SENTRI

1 INTRODUCTION NOTICE WARNINGS AND CAUTIONS NATIONAL APPROVALS EN54 INFORMATION UNPACKING...

Reliably Advanced Extinguishing Control

Conventional & Twin-wire Fire System

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

Xenex Conventional Fire Detection & Alarm System

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

Door Release Power Supply

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

APPLICATION NOTE. Document Type. Application Note. Document Title. Date January Version DS0167/Iss 2. ESP Technical Summary

2000 Series Sensors Installation Guide

Precept Marine Control Panel Application Guide

EP203. Manual. Approved Document No. DFU Rev 2

Hydrosense. Vimpex Limited. Star Lane. Great Wakering. Essex SS3 0PJ. Tel: +44 (0) Fax +44 (0)

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide

5000 INSTALLATION GUIDE

Installation & Commissioning Manual

4 wire conventional alarm system

XP95 Sounder VAD Base

ZFP Networkable Analogue Addressable Fire Alarm Control Panel

General Routing Interface

SOLO Single Loop Addressable Fire Control Panel

NITTAN. EVOLUTION April 2009 EVC-DP Conventional Dual Optical Detector TECHNICAL DATASHEET. Part Numbers and Product Order Codes:Part Number

Discovery 1-4 Loop 96 Zone, 40-Character Analogue Addressable Control Panel. Application Guide

The new detector from Rafiki

MINERVA MX. 800 Series Ancillary Equipment

INPUT / OUTPUT MINI MODULES

FIRE CONTROL PANEL. Revision 1.1 January 1997 USER MANUAL. Emergi-Lite Safety Systems Ltd Bruntcliffe Lane Morley Leeds LS27 9LL

EP203. Manual. Approved Document No. DFU Rev 4

Intellia Sounder Bases and Sounder Beacon Bases

Analogue addressable devices

Product Data Sheet. Remote Terminals. Features:

Installation, Commissioning & Operating Manual

Syncro AS. Analogue Addressable Fire Control Panel. Product Manual

Fire Control Panel. Installation & Programming Manual TABLE OF CONTENTS

Menvier Fire System MF9300

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

PSN-1000 & PSN 1000(E) Installation Manual

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

5000 Series Rack Panels

Doc. No.: OMPII.DOC Rev. 2 Written By: Raj Patel Checked By: AJC Approved By: JBJ Date: 03/05/05

Operation and Maintenance Manual

TECHNICAL DATA OBSOLETE

CFDAU30 Voice Alarm System

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

PREMIER EX8 INSTALLATION MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4 INSTALLATION MANUAL

FIREQUEST ANALOGUE ADDRESSABLE FIRE CONTROL PANEL. Section 1 Installation Manual. Issue 1.3

INFINITY 8 INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL

Sita200plus. 200detectors. Single loop analogue addressable System

Addressable Carbon Monoxide Detection, Monitoring & Ventilation System

JUNO-NET. Fire Alarm Control Panel OPERATION & MAINTENANCE MANUAL

IFD-E Flame Detector User Manual

Transcription:

1 of 9 INTRODUCTION DESCRIPTION The forms part of the Nittan (UK)'s SENSORTEC-ANALOGUE range of Analogue Addressable Devices. This module is designed to control a group of bells or sounders from the detection signalling loop of an analogue-addressable fire detection system. The 'Local Silence' facility permits the connection of a momentary normally open switch, to effect local silencing of the sounders. This switch resets the Sounder Control Module's internal circuit, without affecting other parts of the fire system. Additional fire signals received from the control panel will re-energise the sounder circuit automatically. The sounder circuit is monitored with an end of line resistor, just as a conventional sounder circuit and can drive up to 500mA of sounder load. Polarised sounders are required, or a blocking diode should be used. Various combinations of MCM-AS4 modules or Sounder Control Modules may be used to interface with gas extinguishant systems, conventional fire detection systems or shopping precinct subsystems. OPERATION The fire alarm control equipment must be capable of communicating with the Sounder Control Module. If in doubt, check with panel manufacturer. The is connected on to the detection signalling loop's and -S wires, exactly as any other "AS" device. A 24V d.c. supply must be connected to the, of sufficient capacity to drive the sounders. This supply may be provided by a local PSU if required. The SCM- AS4 is able to inform the control panel if the 24V dc supply to the fails. If a local PSU is used, and it is equipped with a fault change-over relay, then the SCM- AS4 will also monitor this relay and communicate to the control panel the failure of the external PSU. Consideration should be given to the option of mounting Short Circuit Isolators on either side of, and directly adjacent to, the Sounder Control Module. This would protect the operation of the sounder circuit in the event of a short circuit on an adjacent part of the detection signalling loop. The control panel can command the to operate it's sounders continuously, or to pulse them. The pulse timing is 1s on, 1s off, generated by an on-board timer. To prevent several pulsing Sounder Control Modules from gradually drifting out of phase, which may happen due to variations in component tolerances, a synchronisation facility is provided. Synchronisation is achieved by a periodic brief 'synchronised pulse' applied to the Sounder Control Module's Sync. terminal, if this option is required. Sounder Contol Module is made up as follows:- 1 x Metal enclosure c/w 20mm knockouts 1 x PCB c/w internal plastic PCB enclosure with hinged lid. 1 x Earth point (on lid) 1 x Earth point (inside of enclosure) 1 x 200mm Earth Strap 1 x Label inside lid for product identification and device address identification. SENSORTEC-ANALOGUE FAMILY:- SENSORS:- ST-I-AS - Analogue Ionisation Smoke Sensor ST-P-AS - Analogue Photoelectric Smoke Sensor ST-H-AS - Analogue Heat Sensor STB-4 - Standard Base for above sensors DEVICES:- ST-NCP-AS - Addressable Call Point BACK BOX - Back Box for ST-NCP-AS MCM-AS4 - Zone Monitor/Control Unit - Addressable Sounder Control Module NAM-AS3 - Addressable Input Module OCM-AS3 - Output Control Module SCI-5 - Base mounted Short Circuit Isolator SCI-6 - Plate mounted Short Circuit Isolator 1-Gang Box - Single gang box for SCI-6 ADDRESSABLE SOUNDERS:- VCT-03-AS-NB - Addressable Wall Sounder c/w Vector Plate/Cap (R = Red, W = White Plate/Cap). VCT-03-CP(W) - Spare Vector Plate/Cap (White) VCT-03-CP(R) - Spare Vector Plate/Cap (Red) VCT-03-NT-AS - Addressable Sounder c/w STB-4 Base pre-wired to the sounder. VPR-SA2-NTAS - Addressable Sounder, IP65 rated, wall mounted.

2 of 9 INSTALLATION 1) a) Remove the boxed unit from its packaging. b) Remove the 4 x posi-screws holding the lid to the main enclosure of the. c) Completely remove the single top screw holding the P.C.B. enclosure to the rear of the main enclosure. d) Unscrew halfway the two remaining lower screws holding the PCB enclosure to the rear of the main enclosure. e) Gently tilt and lift out the P.C.B. enclosure and safely store the PCB enclosure until the wiring stage. (Note:Please take ESD precautions when removing the P.C.B. from the main enclosure. 2) a) Using initially a 3-4mm 'pilot' drill and then a special 'knock out' drilling tool, as shown below, drill out the required amount of knockout holes for cable gland entry to the main enclosure of. b) Using the template on page 5 of this manual, mark and drill the main enclosure screw positions in the wall. c) Position the enclosure to the wall and screw the 4 x fixing screws through the rear of the enclosure. d) Terminate all the loop cables and glands as required into the knockouts in the main enclosure. e) Insert the PCB enclosure in reverse order as per instructions above. 3) a) Terminate all the loop cables and any IP/OP auxiliary switching cables where required into the terminals on the PCB, please see page 8 of this manual for connection details. b) Please note there is an earthing stud on the lid and on the rear of the main enclosure box if an earth is required on the fire system devices. An earthing cable/strap is provided with the. c) When all the necessary commissioning has successfully been carried out, replace the lid onto the enclosure, replace the 4 x lid fixing posi-screws. Electro-static Sensitive Devices. Take suitable ESD precautions when removing or installing printed circuit boards.

-S SW2 PSU FLT SYNC B+ D+ 0V 3 of 9 ENCLOSURE DESCRIPTION TOP PCB ENCLOSURE FIXING SCREW EARTH STUD 87654321 DIL/Address Setting Switch On LED INDICATIONS COMMS TRIGGERED Ø20.0mm KNOCKOUTS FUSE S- SW1 B- NITTAN (UK) LTD - 2 X LOWER PCB ENCLOSURE FIXING SCREWS PCB/ ENCLOSURE PCB & CABLE TERMINALS TOP VIEW WITH LID REMOVED SIDE VIEW 1 Ø20.0mm KNOCKOUTS SIDE VIEW 2

4 of 9 ENCLOSURE OUTER DIMENSIONS 130mm 44mm 185mm 204mm 163mm Ø20.0mm NOT TO SCALE

5 of 9 ENCLOSURE DIMENSIONS (INTERNAL MOUNTING HOLES) 110mm 142mm Ø4.0mm Ø20.0mm NOT TO SCALE

6 of 9 ENCLOSURE MOUNTING TEMPLATE

-S SW2 PSU FLT SYNC B+ D+ 0V 7 of 9 ENCLOSURE (INTERNAL ASSEMBLY DIMENSIONS) 48mm 87654321 DIL/Address Setting Switch On LED INDICATIONS COMMS TRIGGERED SW1 B- 30mm 30mm 54mm FUSE S- NITTAN (UK) LTD - 160mm 22mm 22mm Ø20.0mm 163mm NOT TO SCALE

-S SW2 PSU FLT SYNC B+ D+ 0V 8 of 9 FIG A. CONNECTION WIRING DETAILS FOR EXTERNAL SOUNDER/BELL CIRCUIT:- LOCAL SILENCE SWITCH OPTIONAL B = Bell or Sounder LOOP IN/ OUT. S- SW1 D+ 0V SW2 PSU FLT B+ B- B B EOL 5K6 0V C/O FAULT RELAY LOCAL PSU A.C. IN + 24v FIG B. CONNECTION DETAILS AND ADDRESS SETTING CONNECTIONS TO PCB ADDRESS SETTING Address: 87654321 DIL/Address Setting Switch On LED INDICATIONS COMMS TRIGGERED = OFF = ON S- SW1 B- FUSE 128 64 32 16 8 4 2 1 Example address switch is set to 37 Decimal. ON OFF 'LOCAL SILENCE' SWITCH INPUT B See FIG A for PSU FLT, D+ and 0V connections IN/OUT OUT/IN COMMUNICATION LOOP EOL BELL/ SOUNDER CIRCUIT TO NEXT Electro-static Sensitive Devices. Take suitable ESD precautions when removing or installing printed circuit boards.

9 of 9 - TECHNICAL SPECIFICATION Part Numbers:- Model Number - -. Description - - Sounder Control Module (Boxed). Computer Reference Number - - F16N85125 Protocol:- Communication Protocol - - NISM/WFM/02 (Nittan AS Protocol). Address Setting - - 8 Bit, DIL Switch Type Identification Data - - 2 Bits Fixed. Ratings:- Current Consumption - - 250µA, (Quiescent). ( Only). Maximum Alarm Current Consumption - - 500µA, (Alarm condition). ( Only). Maximum Sounder/Bell Load - - 500mA (B+ & B-), Permissable with external PSU connected. Power Supply Requirements - - 24V d.c. +/-10%. LED Indications:- On Board LED Indication a) - - Red 'COMMS.' LED:- ('Pulses' when polled). b) - - Red 'TRIGGERED' LED:- ('Pulses' when the sounder circuit operates. Note: 'COMMS' & 'TRIGGERED' LED's both 'Pulse' simultaneously when the sounder circuit operates). General Specifications:- Mass - - 50g (PCB only). - - 1.1Kg complete (Boxed). 20mm Knockouts - - 12 nos. Operating Temperature - - -10 Deg. C. to +50 Deg. C. I.P. Rating - - I.P.43 (Boxed). Earth Strap - - 200mm length, 24/0.2Ø Green/yellow c/w 2 x 4.5-5mm ring crimp ends. On Board Fuse Rating - - 1Amp, 250V. B+& B- Circuit End of Line Resisitor - - 5K6 Ohms. NITTAN (UK) LTD. SUBJECT TO CHANGE WITHOUT PRIOR NOTICE.

Document No.: Date: Pages: 10 inc. cover. From world leaders in SENSOR TECHNOLOGY comes SENSORTEC... SOUNDER CONTROL MODULE INSTALLATION & TECHNICAL NITTAN (UK) LTD. Hipley Street, Old Woking, Surrey, England, GU22 9LQ United Kingdom. Tel: +44 (0) 1483 769555 Fax: +44 (0) 1483 756686 Quality System Certificate No. 041 Assessed to BS EN ISO 9002 Web Site: www.nittan.co.uk E-mail: sales@nittan.co.uk