Internal Use nly http://biz.lgservice.com Room Air Conditioner SVC MANUAL(Exploded View) MDEL : LSN090HSV4 / LSU090HSV4 (ASNW09GB1B0 / ASUW093BUB6) LSN120HSV4 / LSU120HSV4 (ASNW12GB1B0 / ASUW123BUB6) LSN180HSV4 / LSU180HSV4 (ASNW18GC2B0 / ASUW183CUB6) LAN090HSV4 / LSU090HSV4 (ASNW09GBRB0 / ASUW093BUB6) LAN120HSV4 / LSU120HSV4 (ASNW12GBRB0 / ASUW123BUB6) LAN180HSV4 / LSU180HSV4 (ASNW18GCRB0 / ASUW183CUB6) LAN240HSV4/LAU240HSV4 (ASNW243CRB6 / ASUW243CRB6) CAUTIN Before Servicing the unit, read the safety precautions in General SVC manual. nly for authorized service personnel.
1. Product Specifications Buyer Model (Indoor Unit / utdoor unit) LS-090HSV4 LS-120HSV4 LS-180HSV4 (LSN090HSV4 / LSU090HSV4) (LSN120HSV4 / LSU120HSV4) (LSN180HSV4 / LSU180HSV4) Unit Factory Model (Indoor Unit / utdoor unit) AS-W09GB1B0 AS-W12GB1B0 AS-W18GC2B0 (ASNW09GB1B0 / ASUW093BUB6) (ASNW12GB1B0 / ASUW123BUB6) (ASNW18GC2B0 / ASUW183CUB6) Cooling Capacity (Min ~ Rated ~ Max) kw Btu/h 0.30 ~ 2.64 ~ 3.70 1,023 ~ 9,000 ~ 12,625 0.30 ~ 3.28 ~ 4.03 1,023 ~ 11,200 ~ 13,785 0.90 ~ 5.33 ~ 8.65 3,070 ~ 18,200 ~ 29,515 Heating Capacity (Min ~ Rated ~ Max) kw Btu/h 0.30 ~ 3.16 ~ 5.00 1,023 ~ 10,800 ~ 17,061 0.30 ~ 3.90 ~ 6.50 1,023 ~ 13,300 ~ 22,178 0.90 ~ 6.45 ~ 11.40 3,070 ~ 22,000 ~ 38,898 utdoor 17ºF (Indoor 70ºF) Btu/h 8,856 (82%) 10,906 (82%) 18,040 (82%) Maximum Heating Capacity utdoor 5ºF (Indoor 70ºF) Btu/h 7,452 (69%) 9,177 (69%) 15,180 (69%) utdoor -4ºF (Indoor 70ºF) Btu/h 7,236 (67%) 8,911 (67%) 14,740 (67%) Power Input Cooling / Heating W 677 / 700 896 / 1000 1,447 / 1,760 Running Current Cooling / Heating A 2.90 / 3.04 3.90 / 4.35 6.30 / 8.20 Starting Current Cooling / Heating A 2.90 / 3.04 3.90 / 4.35 6.30 / 8.20 EER - 13.29 12.5 12.6 SEER - 21.5 21.5 20.5 CP - 4.51 3.9 3.66 HSPF (Ⅳ / Ⅴ) a) - 10.8 / 9.4 11.0 / 9.6 9.7 / 8.4 Power Supply Ø / V / Hz 1 / 208-230 / 60 1 / 208-230 / 60 1 / 208-230 / 60 Power Factor % 93.5 93.5 98.2 Air Flow Rate Indoor,Max/H/M/L utdoor,max CFM(m 3 /min) CFM(m 3 /min) 423 (12.0) / 353 (10.0) / 272 (7.7) / 191 (5.4) 1,165 (33) 423 (12.0) / 353 (10.0) / 272 (7.7) / 191 (5.4) 1,165 (33) 735 (20.8) / 622 (17.6) / 509 (14.4) / 399 (11.3) 2,119 (60) Moisture Removal pts/h (l/h) 2.3 (1.1) 2.3 (1.1) 5.5 (2.6) Indoor,H/M/L/SL (Cooling) db(a)+3 38 / 33 / 23 / 19 39 / 33 / 23 / 19 45 / 40 / 35 / 29 Sound Level Indoor,H/M/L (Heating) db(a)+3 38 / 33 / 23 39 / 33 / 23 45 / 40 / 35 utdoor,max db(a)+3 45 45 53 Type - Single Rotary Single Rotary Twin Rotary Model - GA102MFB GA102MFB GJT240MBA Compressor Motor Type il Type - - Brushless DC Motor PVE (FVC68D) Brushless DC Motor PVE (FVC68D) Brushless DC Motor PVE (FVC68D) il Charge cc 310 310 900.L.P. name - - - - Fan(Indoor) Type Motor utput - W Cross Flow Fan 30 Cross Flow Fan 30 Cross Flow Fan 30 Type - Propeller Fan Propeller Fan Propeller Fan(utdoor) Motor Type - BLDC BLDC BLDC Motor utput W 43 43 124 Circuit Breaker* A 15 15 25 Power Supply Cable No. AWG 3 14 3 14 3 12 Power and Transmission Cable No. AWG 4 18 4 18 4 18 Piping Connections Liquid Side Gas Side in (mm) in (mm) Ø 1/4 (6.35) Ø 3/8 (9.52) Ø 1/4 (6.35) Ø 3/8 (9.52) Ø 3/8 (9.52) Ø 5/8 (15.88) Drain Hose(.D, I.D.) in (mm) 27/32, 5/8 (21.5, 16.0) 27/32, 5/8 (21.5, 16.0) 27/32, 5/8 (21.5, 16.0) Dimensions Indoor (W H D) mm inch 885 285 210 34-13/16 11-1/4 8-1/4 885 285 210 34-13/16 11-1/4 8-1/4 1,030 325 250 40-9/16 12-13/16 9-13/16 utdoor (W H D) mm inch 770 545 288 30-5/16 21-1/2 11-5/16 770 545 288 30-5/16 21-1/2 11-5/16 870 800 320 34-1/4 31-1/2 12-19/32 Net Weight Indoor utdoor lbs (kg) lbs (kg) 19.4 (8.8) 75 (34) 19.4 (8.8) 75 (34) 30.9 (14.0) 120.2 (54.5) Gross Weight Indoor utdoor lbs (kg) lbs (kg) 26.0 (11.8) 78.9 (35.8) 26.0 (11.8) 78.9 (35.8) 35.3 (16.0) 130.1 (59.0) peration Range Cooling (utdoor) Heating (utdoor) ( ) DB ( ) WB 14 [0 b) ] ~ 118 (-10 [-18 b) ] ~ 48) -4 ~ 65 (-20 ~ 18) 14 [0 b) ] ~ 118 (-10 [-18 b) ] ~ 48) -4 ~ 65 (-20 ~ 18) 14 [0 b) ] ~ 118 (-10 [-18 b) ] ~ 48) -4 ~ 65 (-20 ~ 18) Refrigerant & Charge oz (g) R410A / 35.3 (1,000) R410A / 35.3 (1,000) R410A / 63.5 (1,800) Additional Refrigerant Charge oz/ft (g/m) 0.22 (20) 0.22 (20) 0.38 (35) Piping Length (Min/Max) ft (m) 6.6 (2) / 65.6 (20) 6.6 (2) / 65.6 (20) 9.84 (3) / 98.4 (30) Chargeless ft (m) 41 (12.5) 41 (12.5) 24.6 (7.5) Max. Elevation Difference ft (m) 32.8 (10) 32.8 (10) 49.2 (15) Tool Code(Chassis) Indoor + utdoor SB + UL2 SB + UL2 SC + UE1+ Temperature Control Thermistor Thermistor Thermistor Allergy free filter - - - Plasma Filter - - - Prefilter (Washable/Anti-fungus) 3M Micro Protection filter Auto Clean CHAS Wind(Auto Wind) Steps, Fan/Cool/Heat 6 / 6 / 6 6 / 6 / 6 6 / 6 / 6 Airflow Direction Control(Up& Down) Auto Auto Auto Airflow Direction Control(Left & Right) Auto Auto Auto Remote Controller Type Wireless LCD Wireless LCD Wireless LCD Functions Setting Temperature Range Note : : Applied, X : No relation, : No relation Filters are optional in some specific areas. For Circuit Breaker Rating, please conform to local standards whenever necessary. If you use Wi-Fi, Wi-Fi module must be purchased separately. Cooling[ ( )] 64~86 (18~30) 64~86 (18~30) 64~86 (18~30) Heating[ ( )] 60~86 (16~30) 60~86 (16~30) 60~86 (16~30) Auto peration (Micom Control) - - - Auto Changeover (Micom Control) Self Diagnosis Timer 24h, n/ff 24h, n/ff 24h, n/ff Sleep peration Soft Dry peration Restart Delay (Minute) 3 3 3 Deice Control (Defrost) Hot Start Jet Cool / Jet Heat Low Ambient peration Special Function Wi-Fi, Water Level sensor, Cooling nly switch, WIND BAFFLE Wi-Fi, Water Level sensor, Cooling nly switch, WIND BAFFLE Wi-Fi, Water Level sensor, Cooling nly switch, WIND BAFFLE a) HSPF Region V = HSPF Region IV / 1.15 - HSPF IV values comply with US standard. - HSPF V values comply with Canada standard. b) * : With wind baffle installed, the minimum temperature will be 0 D.B. in cooling. - 2 -
Buyer Model (Indoor Unit / utdoor unit) LA-090HSV4 LA-120HSV4 LA-180HSV4 (LAN090HSV4 / LSU090HSV4) (LAN120HSV4 / LSU120HSV4) (LAN180HSV4 / LSU180HSV4) Unit Factory Model (Indoor Unit / utdoor unit) AS-W09GBRB0 AS-W12GBRB0 AS-W18GCRB0 (ASNW09GBRB0 / ASUW093BUB6) (ASNW12GBRB0 / ASUW123BUB6) (ASNW18GCRB0 / ASUW183CUB6) Cooling Capacity (Min ~ Rated ~ Max) kw Btu/h 0.30 ~ 2.64 ~ 3.70 1,023 ~ 9,000 ~ 12,625 0.30 ~ 3.28 ~ 4.03 1,023 ~ 11,200 ~ 13,785 0.90 ~ 5.33 ~ 8.65 3,070 ~ 18,200 ~ 29,515 Heating Capacity (Min ~ Rated ~ Max) kw Btu/h 0.30 ~ 3.16 ~ 5.00 1,023 ~ 10,800 ~ 17,061 0.30 ~ 3.90 ~ 6.50 1,023 ~ 13,300 ~ 22,178 0.90 ~ 6.45 ~ 11.40 3,070 ~ 22,000 ~ 38,898 utdoor 17ºF (Indoor 70ºF) Btu/h 8,856 (82%) 10,906 (82%) 18,040 (82%) Maximum Heating Capacity utdoor 5ºF (Indoor 70ºF) Btu/h 7,452 (69%) 9,177 (69%) 15,180 (69%) utdoor -4ºF (Indoor 70ºF) Btu/h 7,236 (67%) 8,911 (67%) 14,740 (67%) Power Input Cooling / Heating W 677 / 700 896 / 1000 1,447 / 1,760 Running Current Cooling / Heating A 2.90 / 3.04 3.90 / 4.35 6.30 / 8.20 Starting Current Cooling / Heating A 2.90 / 3.04 3.90 / 4.35 6.30 / 8.20 EER - 13.29 12.5 12.6 SEER - 21.5 21.5 20.5 CP - 4.51 3.9 3.66 HSPF (Ⅳ / Ⅴ) a) - 10.8 / 9.4 11.0 / 9.6 9.7 / 8.4 Power Supply Ø / V / Hz 1 / 208-230 / 60 1 / 208-230 / 60 1 / 208-230 / 60 Power Factor % 93.5 93.5 98.2 Air Flow Rate Indoor,Max/H/M/L utdoor,max CFM(m 3 /min) CFM(m 3 /min) 423 (12.0) / 353 (10.0) / 272 (7.7) / 191 (5.4) 1,165 (33) 423 (12.0) / 353 (10.0) / 272 (7.7) / 191 (5.4) 1,165 (33) 735 (20.8) / 622 (17.6) / 509 (14.4) / 399 (11.3) 2,119 (60) Moisture Removal pts/h (l/h) 2.3 (1.1) 2.3 (1.1) 5.5 (2.6) Indoor,H/M/L/SL (Cooling) db(a)+3 38 / 33 / 23 / 19 39 / 33 / 23 / 19 45 / 40 / 35 / 29 Sound Level Indoor,H/M/L (Heating) db(a)+3 38 / 33 / 23 39 / 33 / 23 45 / 40 / 35 utdoor,max db(a)+3 45 45 53 Type - Single Rotary Single Rotary Twin Rotary Model - GA102MFB GA102MFB GJT240MBA Compressor Motor Type il Type - - Brushless DC Motor PVE (FVC68D) Brushless DC Motor PVE (FVC68D) Brushless DC Motor PVE (FVC68D) il Charge cc 310 310 900.L.P. name - - - - Fan(Indoor) Type Motor utput - W Cross Flow Fan 30 Cross Flow Fan 30 Cross Flow Fan 30 Type - Propeller Fan Propeller Fan Propeller Fan(utdoor) Motor Type - BLDC BLDC BLDC Motor utput W 43 43 124 Circuit Breaker* A 15 15 25 Power Supply Cable No. AWG 3 14 3 14 3 12 Power and Transmission Cable No. AWG 4 18 4 18 4 18 Piping Connections Liquid Side Gas Side in (mm) in (mm) Ø 1/4 (6.35) Ø 3/8 (9.52) Ø 1/4 (6.35) Ø 3/8 (9.52) Ø 3/8 (9.52) Ø 5/8 (15.88) Drain Hose(.D, I.D.) in (mm) 27/32, 5/8 (21.5, 16.0) 27/32, 5/8 (21.5, 16.0) 27/32, 5/8 (21.5, 16.0) Dimensions Indoor (W H D) mm inch 885 285 205 34-13/16 11-1/4 8-1/16 885 285 205 34-13/16 11-1/4 8-1/16 1,030 325 245 40-9/16 12-13/16 9-11/16 utdoor (W H D) mm inch 770 545 288 30-5/16 21-1/2 11-5/16 770 545 288 30-5/16 21-1/2 11-5/16 870 800 320 34-1/4 31-1/2 12-19/32 Net Weight Indoor utdoor lbs (kg) lbs (kg) 23.1 (10.5) 75 (34) 23.1 (10.5) 75 (34) 32.0 (14.5) 120.2 (54.5) Gross Weight Indoor utdoor lbs (kg) lbs (kg) 28.7 (13.0) 78.9 (35.8) 28.7 (13.0) 78.9 (35.8) 38.6 (17.5) 130.1 (59.0) peration Range Cooling (utdoor) Heating (utdoor) ( ) DB ( ) WB 14 [0 b) ] ~ 118 (-10 [-18 b) ] ~ 48) -4 ~ 65 (-20 ~ 18) 14 [0 b) ] ~ 118 (-10 [-18 b) ] ~ 48) -4 ~ 65 (-20 ~ 18) 14 [0 b) ] ~ 118 (-10 [-18 b) ] ~ 48) -4 ~ 65 (-20 ~ 18) Refrigerant & Charge oz (g) R410A / 35.3 (1,000) R410A / 35.3 (1,000) R410A / 63.5 (1,800) Additional Refrigerant Charge oz/ft (g/m) 0.22 (20) 0.22 (20) 0.38 (35) Piping Length (Min/Max) ft (m) 6.6 (2) / 65.6 (20) 6.6 (2) / 65.6 (20) 9.84 (3) / 98.4 (30) Chargeless ft (m) 41 (12.5) 41 (12.5) 24.6 (7.5) Max. Elevation Difference ft (m) 32.8 (10) 32.8 (10) 49.2 (15) Tool Code(Chassis) Indoor + utdoor SB + UL2 SB + UL2 SC + UE1+ Temperature Control Thermistor Thermistor Thermistor Allergy free filter - - - Plasma Filter - - - Prefilter (Washable/Anti-fungus) 3M Micro Protection filter Auto Clean CHAS Wind(Auto Wind) Steps, Fan/Cool/Heat 6 / 6 / 6 6 / 6 / 6 6 / 6 / 6 Airflow Direction Control(Up& Down) Auto Auto Auto Airflow Direction Control(Left & Right) Auto Auto Auto Remote Controller Type Wireless LCD Wireless LCD Wireless LCD Functions Setting Temperature Range Note : : Applied, X : No relation, : No relation Filters are optional in some specific areas. For Circuit Breaker Rating, please conform to local standards whenever necessary. Cooling[ ( )] 64~86 (18~30) 64~86 (18~30) 64~86 (18~30) Heating[ ( )] 60~86 (16~30) 60~86 (16~30) 60~86 (16~30) Auto peration (Micom Control) - - - Auto Changeover (Micom Control) Self Diagnosis Timer 24h, n/ff 24h, n/ff 24h, n/ff Sleep peration Soft Dry peration Restart Delay (Minute) 3 3 3 Deice Control (Defrost) Hot Start Jet Cool / Jet Heat Low Ambient peration Special Function Water Level sensor, Cooling nly switch, WIND BAFFLE Water Level sensor, Cooling nly switch, WIND BAFFLE Water Level sensor, Cooling nly switch, WIND BAFFLE a) HSPF Region V = HSPF Region IV / 1.15 - HSPF IV values comply with US standard. - HSPF V values comply with Canada standard. b) * : With wind baffle installed, the minimum temperature will be 0 D.B. in cooling. - 3 -
Cooling Capacity (Min ~ Rated ~ Max) Heating Capacity (Min ~ Rated ~ Max) Maximum Heating Capacity Buyer Model (Indoor Unit / utdoor unit) Factory Model (Indoor Unit / utdoor unit) LA-240HSV4 (LAN240HSV4 / LAU240HSV4) Unit AS-W243CRB6 (ASNW243CRB6 / ASUW243CRB6) kw 0.90 ~ 6.45 ~ 8.80 Btu/h 3,070~22,000~30,030 kw 0.90 ~ 8.09 ~ 11.40 Btu/h 3,070~27,600~38,898 utdoor 17ºF (Indoor 70ºF) Btu/h 22,498 (82%) utdoor 5ºF (Indoor 70ºF) Btu/h 19,097 (69%) utdoor -4ºF (Indoor 70ºF) Btu/h 18,424 (67%) Power Input Cooling / Heating W 2,040 / 2,670 Running Current Cooling / Heating A 7.9 / 10.7 Starting Current Cooling / Heating A 7.9 / 10.7 EER - 10.78 SEER - 20.00 CP - 3.03 HSPF (Ⅳ / Ⅴ) a) - 10.00 / 8.70 Power Supply Ø / V / Hz 1 / 208-230 / 60 Power Factor % 98.2 Indoor,Max/H/M/L 735 (20.8) / 622 (17.6) / 509 (14.4) / 399 (11.3) Air Flow Rate utdoor,max 2,119 (60) Moisture Removal l/h (pts/h) 5.5 (2.6) Sound Level Compressor Fan(Indoor) Fan(utdoor) Indoor,H/M/L/SL (Cooling) db(a)+3 45 / 40 / 35 / 29 Indoor,H/M/L (Heating) db(a)+3 45 / 40 / 35 utdoor,max db(a)+3 53 Type - Twin Rotary Model - GJT240MBA Motor Type - Brushless DC Motor il Type - PVE (FVC68D) il Charge cc 900.L.P. name - - Type - Cross Flow Fan Motor utput W 30 Type - Propeller Motor Type - BLDC Motor utput W 124 Circuit Breaker* A 25 Power Supply Cable No. AWG 3 12 Power and Transmission Cable No. AWG 4 18 Piping Connections Liquid Side in (mm) Ø 3/8 (9.52) Gas Side in (mm) Ø 5/8 (15.88) Drain Hose(.D, I.D.) in (mm) 27/32, 5/8 (21.5, 16.0) Dimensions Indoor (W H D) mm 1,030 325 245 inch 40-9/16 12-13/16 9-11/16 utdoor (W H D) mm 870 800 320 inch 34-1/4 31-1/2 12-19/32 Net Weight Indoor lbs (kg) 32.0 (14.5) utdoor lbs (kg) 120.2 (54.5) Gross Weight Indoor lbs (kg) 38.6 (17.5) utdoor lbs (kg) 130.1 (59.0) peration Range Cooling (utdoor) ( ) DB 14 [0*] ~ 118 (-10 [-18*] ~ 48) Heating (utdoor) ( ) WB -4 ~ 65 (-20 ~ 18) Refrigerant & Charge oz (g) R410A / 63.5 (1,800) Additional Refrigerant Charge oz/ft (g/m) 0.38 (35) Piping Length (Min/Max) ft (m) 9.84 (3) / 98.4 (30) Chargeless ft (m) 24.6 (7.5) Max. Elevation Difference ft (m) 49.2 (15) Tool Code(Chassis) Indoor + utdoor SC + UE1+ Functions Temperature Control Thermistor Allergy free filter - Plasma Filter - Prefilter (Washable/Anti-fungus) 3M Multi Protection filter Auto Clean CHAS Wind(Auto Wind) Steps, Fan/Cool/Heat 6 / 6 / 6 Airflow Direction Control(Up& Down) Auto Airflow Direction Control(Left & Right) Auto Remote Controller Type Wireless LCD Setting Temperature Range Cooling[ ( )] 64~86 (18~30) Heating[ ( )] 60~86 (16~30) Auto peration (Micom Control) - Auto Changeover (Micom Control) Self Diagnosis Timer 24h, n/ff Sleep peration Soft Dry peration Restart Delay (Minute) 3 Deice Control (Defrost) Hot Start Jet Cool / Jet Heat Low Ambient peration Special Function Water Level sensor, Cooling nly switch, WIND BAFFLE - 4 -
2. Piping Diagrams LS090HSV4 (AS-W09GB1B0), LS120HSV4 (AS-W12GB1B0), LA090HSV4 (AS-W09GBRB0), LA120HSV4 (AS-W12GBRB0) Indoor Unit utdoor Unit FIELD PIPING (Ø 1/4 Copper Tubing) 2-Way Valve Th1 Th2 M Liquid Side EEV Th6 Heat Exchanger (Evaporator) Th3 M Heat Exchanger (Condenser) Th4 Th5 FIELD PIPING (Ø 3/8 Copper Tubing) 3-Way Valve Reversing Valve Th7 Gas Side Accumulator Th8 Compressor : Cooling : Heating LC. Description PCB Connector Th1 Thermistor for indoor air temperature Th2 Thermistor for evaporator inlet temperature CN-TH1 (Indoor) Th3 Thermistor for evaporator middle temperature Th4 Thermistor for evaporator outlet temperature CN- (Indoor) Th5 Water Level Sensor (ption) CN-TH3 (Indoor) Th6 Thermistor for outdoor air temperature Th7 Thermistor for condensing temperature CN-TH1 (utdoor) Th8 Thermistor for discharge pipe temperature CN- (utdoor) EEV : Electronic Expansion Valve - 5 -
LS180HSV4 (AS-W18GC2B0), LA180HSV4 (AS-W18GCRB0), LA240HSV4(AS-W243CRB6) Indoor Unit utdoor Unit FIELD PIPING (Ø 3/8 Copper Tubing) 2-Way Valve Th1 Th2 M Liquid Side EEV Th6 Heat Exchanger (Evaporator) Th3 M Heat Exchanger (Condenser) Th4 Th5 FIELD PIPING (Ø 5/8 Copper Tubing) 3-Way Valve Reversing Valve Th7 Gas Side Accumulator Th8 Compressor : Cooling : Heating LC. Description PCB Connector Th1 Thermistor for indoor air temperature Th2 Thermistor for evaporator inlet temperature CN-TH1 (Indoor) Th3 Thermistor for evaporator middle temperature Th4 Thermistor for evaporator outlet temperature CN- (Indoor) Th5 Water Level Sensor (ption) CN-TH3 (Indoor) Th6 Thermistor for outdoor air temperature Th7 Thermistor for condensing temperature CN- (utdoor) Th8 Thermistor for discharge pipe temperature CN-TH3 (utdoor) h EEV : Electronic Expansion Valve - 6 -
3. Wiring Diagrams Indoor Unit LSN090HSV4 (ASNW09GB1B0), LSN120HSV4 (ASNW12GB1B0) * Auxiliary heater relay kit is not available on single zone wall mounted models. CN_PWER CN_MTR CN_UD CN_LR CN_LR2 CN_SCAN CN_DATA CN_TH3 CN_ CN_TH1 CN_REM CN_UART CN_CC - 7 -
LSN180HSV4 (ASNW18GC2B0) * Auxiliary heater relay kit is not available on single zone wall mounted models. CN_PWER CN_MTR CN_UD CN_LR CN_LR2 CN_SCAN CN_DATA CN_TH3 CN_ CN_TH1 CN_REM CN_UART CN_CC - 8 -
LAN090HSV4 (ASNW09GBRB0), LAN120HSV4 (ASNW12GBRB0) * Auxiliary heater relay kit is not available on single zone wall mounted models. CN_PWER CN_MTR CN_UD CN_LR CN_LR2 CN_SCAN CN_DATA CN_TH3 CN_ CN_TH1 CN_REM CN_UART CN_CC - 9 -
LAN180HSV4 (ASNW18GCRB0), LAN240HSV4(ASNW243CRB6) * Auxiliary heater relay kit is not available on single zone wall mounted models. CN_PWER CN_MTR CN_UD CN_LR CN_LR2 CN_SCAN CN_DATA CN_TH3 CN_ CN_TH1 CN_REM CN_UART CN_CC - 10 -
utdoor Unit LSU090HSV4 (ASUW093BUB6), LSU120HSV4 (ASUW123BUB6) : Factory Wiring : Field Wiring : PTIN CN_UVW CN_FAN CN_TH1 CN_ CN_EEV CN_4WAY CN_HEATER CN_CENTRAL CN_LGMV CN_CIL1 CM_RD WCN_P(L) CN2 CN_CIL2 CN3 WCN_P(N) - 11 -
LSU180HSV4 (ASUW183CUB6), LAU240HSV4(ASUW243CRB6) CN_PFC_IN CN_4WAY CN_PFC_UT CN_HEATER1 CN_ CN_TH3 CN_LGMV CN_CP_N WCN_PWER CN_CP_L CN_CENTRAL CN_MTR1 CN_EEV1 CN_CM - 12 -
4. Exploded View Indoor Unit LSN090HSV4 (ASNW09GB1B0), LSN120HSV4 (ASNW12GB1B0) 152302B 135316 268711G 135500B 268711F 268711A 131111 152302A 131410 135313 267110 149304 342800 149303 135500A 733010 354210 354212 135080 146811B 352150 359011 346810 TH1 268711B 147582 135311 145200A 145200B 147581 35211B 146811A W50400 749740 268711D 135500C 263230C 249951 W6640A LC. Description Connector Thermistor for indoor air temperature Thermistor for evaporator inlet temperature TH1 Thermistor for evaporator middle temperature 263230C Thermistor for evaporator outlet temperature Note) Please ensure GCSC since the replacement parts may be changed depending upon the buyer's request. Please check the correct parts in View RPL(Replacement Part List) on GCSC. (GCSC Website http://www.lge.com) - 13 -
LSN180HSV4 (ASNW18GC2B0) 152302B 135316 152301 268711G 268711F 268711A 131111 135511 131410 135313 149303 733010 359011 267110 342800 135500C 149304 135090 354212 W50400 352150 354210 346810 249951 135500A 146811B 35211B 268711E 268711C 147582 135500B 145200A 145200B 146811A 263230C TH1 W6640 135311 147581 LC. Description Connector Thermistor for indoor air temperature Thermistor for evaporator inlet temperature TH1 Thermistor for evaporator middle temperature 263230C Thermistor for evaporator outlet temperature Note) * Please ensure GCSC since the replacement parts may be changed depending upon the buyer's request. Please check the correct parts in View RPL(Replacement Part List) on GCSC. (GCSC Website http://www.lge.com) - 14 -
LAN090HSV4 (ASNW09GBRB0), LAN120HSV4 (ASNW12GBRB0) 135316 ption Part 159830A 131111 268711F 152302 135500B 131410 268711A 135313 149303 733010 149304 267110 342800 354210 135500A 354212 135080 352150 146811B W50400 359011 346810 268711B TH1 135500C 147582 135311 145200A 145200B 147581 146811A 35211B 268711D 749740 263230C 249951 W6640A LC. Description Connector Thermistor for indoor air temperature Thermistor for evaporator inlet temperature TH1 Thermistor for evaporator middle temperature 263230C Thermistor for evaporator outlet temperature Note) * Please ensure GCSC since the replacement parts may be changed depending upon the buyer's request. Please check the correct parts in View RPL(Replacement Part List) on GCSC. (GCSC Website http://www.lge.com) - 15 -
LAN180HSV4 (ASNW18GCRB0), LAN240HSV4(ASNW243CRB6) 135316 159830A 152301 268711F 131111 268711A 135511 131410 135313 149303 733010 359011 267110 342800 135500C 149304 354212 135090 146811B 147582 145200A 352150 145200B 354210 W50400 146811A 35211B 263230C 135500B 249951 346810 135500A 268711E 268711C W6640 TH1 135311 147581 LC. Description Connector Thermistor for indoor air temperature Thermistor for evaporator inlet temperature TH1 Thermistor for evaporator middle temperature 263230C Thermistor for evaporator outlet temperature Note) * Please ensure GCSC since the replacement parts may be changed depending upon the buyer's request. Please check the correct parts in View RPL(Replacement Part List) on GCSC. (GCSC Website http://www.lge.com) - 16 -
utdoor Unit LSU090HSV4 (ASUW093BUB6), LSU120HSV4 (ASUW123BUB6) 435301 559010 237202 137213B 437211 435512 554031 435300 263230C 549610 W4986C 546810 W4986A 554160 552202 W6631 550140 W4986B 552116B 561410 148000 552116A 261704 430410 553000 447910 152503 649950 135500 552112 661400 552200B 55211G 552203B 552203A 435513 268711B W6640 137213A LC. Description Connector Thermistor for outdoor air temperature Thermistor for condensing temperature TH1 Thermistor for discharge pipe temperature - 17 -
LSU180HSV4 (ASUW183CUB6), LAU240HSV4(ASUW243CRB6) 437211 435301 349480 435512 437210 137213A 435300 554031 W4810D 549610 352111 546810 552117 W6640 W6200 552202 559010 W6631 447910 554160 550140 152503 430410 137213B 435511B 135500 552113 552115 649950 268711 435511A 552116 561410 661400 552200 552203A 552203B W49810 55211G LC. Description Connector Thermistor for outdoor air temperature Thermistor for condensing temperature Thermistor for discharge pipe temperature TH3-18 -
US 1. Please call the installing contractor of your product, as warranty service will be provided by them. 2. If you have service issues that have not been addressed by the contractor, please call 1-888-865-3026. CANADA Service call Number # : (888) LG Canada, (888) 542-2623 P/N : MFL67501917 December, 2014