MPCA RSB

Similar documents
MPCA HSB PACKAGED AIR TO WATER HEAT PUMP COOLING/HEATING OUTDOOR INSTALLATION

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

LPCA RMB PACKAGED AIR COOLED WATER CHILLER COOLING ONLY OUTDOOR INSTALLATION

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Condensing Units CUS 15-60

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

AQUASNAP JUNIOR 30RHV

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

Modular Air Cooled Scroll Chillers

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

MODELS LIST. Nominal Capacity RT

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

.2 Section Waste Management and Disposal.

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

MAC N-407 Air-Cooled Chiller

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

MACH N-407 Heat Pump Air-Cooled Chiller

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

LZT High efficiency air to water heat pumps with E.V.I. compressors

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

PYXIS U PYXIS U. rcgroupairconditioning

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

AWR MTD2 XE. Versions

MAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water.

Call us today! (800)

HT V2 HT Split

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Water chillers water/water type SIGMA Technical information manual

AIR COOLED PACKAGED CHILLER

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

Ultimate energy saving technology

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

GLIDER EVO GLIDER EVO. rcgroupairconditioning

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

MAC-120HE-03 Air-Cooled Chiller

Concealed Ducted Split Series R-407C MBH

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

Chiller units and air-water heat pumps RANGE OPERATING LIMITS

Ultimate energy saving technology

HYDRONIC RESIDENTIAL

30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG +

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

LZT High efficiency air to water heat pumps with E.V.I. compressors

<IMG INFO> 339,95 195, ,35 14,15-1. ENERGY 400 Four Steps Chiller Heat Pump Controller

30RB/RQ Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump 30RB: Nominal cooling capacity: kw 30RQ: Nominal cooling capacity:

High temperature air-to-water heat pumps

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

LZA High efficiency air to water heat pumps with HP compressor

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

GLIDER EVO CLA GLIDER EVO CLA HIGHEFFICIENCY ACLASS. rcgroupairconditioning

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

EPCE00-10B. Powerful. air cooled. Hydronic systems EUWA*40-200K(A)X

ENERGY 200 Electronic Control for mono & bi- Compressor CHILLERS. User Manual

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

30RH B Nominal cooling capacity kw Nominal heating capacity kw

Call us today! (800)

Neosys Product catalogue

Call us today! (800)

Industrial cooling solutions

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Transcription:

MPC 00-0-0-09-0-09 0-06RB PCKGED IRCOOLED WER CILLER COOLIG OLY OUDOOR ILLIO Cooling Capacity: 8, - 6, R0c croll Features he Interklima MPC - RB medium capacity series are packaged air cooled water chillers for cooling applications and outdoor installation. hey are available in 8 models with nominal capacities ranging from 8, to 6,. his series is ideal in combination with Interklima fan coils or air handling units for residences, offices, hotels, hospitals, shopping malls, shops, restaurants, etc., or for supplying chilled water for industrial applications. Optimized design for R0c refrigerant. Casing: Galvanized steel plate with polyesteric coating. ssembly Fully bolted/welding free. Compressor: ermetically sealed scroll type. ir heat exchanger: Cross fin coil. Internally grooved copper tubes and louvered aluminium fins. Direct drive propeler fan: Low rpm, quiet operation. Water heat exchanger: hell and tube type. afety and functional devices: - igh/low pressure switch. - Linear fan speed regulation according to coil temperature. - Differential water pressostat. - Evaporator low water temperature protection. - Electronic microprosessor control with digital display. - Phase sequence-phase failure-reverse phase and voltage monitoring device. - igh and low pressure manometers.

OMECLURE Range -small M-mid L-large R-screw-series Packaged Chiller ir-cooled PC Model numbers 00-0-0-09-0-0-09-00-0-06-0-08-0-0-06-0 Cool / eat Model R-cooling only -heat pump Compressor type -scroll M-tandem scroll R-reciprocating -twin screw 6 Refrigerant type -R B-R0c Electrical Characteristic - ingle phase -Ommited hree phase

Contents. echnical Description. pecifications. Capacity ables. Water Pressure Drop Curves. Operation Range 6. ound Data. Outlook Drawings 8. Refrigerant Circuit Diagrams 9. Wiring Diagrams 0. Installation. Guide pecifications MPC 00-06RB ñ R0c/croll

. echnical Description General he MPC-RB series air-cooled water chillers consists of 8 models covering capacities from 8, up to 6,. It is the end result of a thorough study, and accurate design by experienced Interklima research and development teams, to develop a mid size chiller series with compact shape, high performance, and reliability of the highest quality standards. his series meets the highest levels of aesthetic and technical requirements using the latest technological innovations including environmentally friendly R0c refrigerant that is Chlorine-free and has zero ozone depletion potential. MPC-RB units are therefore ideal for installation in urban environments due to their elegant design, selected materials and low operating sound levels. Casing ll units use metal parts that are fabricated from heavy gauge galvanized steel sheets, formed to ensure maximum rigidity that guarantees and preserves the units operation during the years. fter fabrication these are degreased, phosphatised, and electrostatically powder coated with an epoxy-polyester RL 900 coating of a thickness of 60-0 Ì. his fully automatic process ensures superior corrosion resistance against the most aggressive ambient conditions. he treatment can successfully withstand a salt spray test of 00 hours, according to M B-. ll components are assembled together using bolts thus avoiding the need for welding which may harm the galvanization of the steel, and ensures that the whole assembly can fully withstand adverse weather conditions. he compact footprint of the unit arises from detailed study and design by our engineering teams and results in a machine, which fits easily in restricted areas and is simple and easy to install and maintain, and has been designed with special fittings for easy transport and lifting. Removable side panels with special locks are used to permit access only to authorized personnel to internal components of the unit for inspection and maintenance. Electrical and electronic equipment and components for proper unit operation are located in a weather proof (IP ) electrical panel with access via a special key. Compressor ll units use low-noise, maintenance free, ermetic croll compressors with low vibration levels, specially optimized for use with R0c refrigerant. hey are equipped with a crankcase electrical heater for the oil, and are internally protected against potential overloading or electrical spikes. he compressors are mounted on special antivibration rubber mounts to eliminate vibration from the unit s operation. ir heat exchanger ll air heat exchangers are manufactured from high quality seamless inner grooved copper tubes according to M B-80, having an outside diameter of 9, mm (/8"). he fins are manufactured from aluminium and form the secondary extended heat transfer surface. he fins are continuous across the heat exchanger and are fabricated in high precision dedicated press lines. he fin surface is waffle formed, so as to increase the fin rigidity, and have special louvers that help increase heat transfer. he combination of internally grooved Copper-tubing and louvered fins has resulted in a heat transfer performance 0% superior to that of a conventional coil for this particular application. he assembly of the finned pack is achieved by mechanical expansion of the tubes in such a way as to form a perfect mechanical bond with the fins. For this purpose, the fin holes have a peripheral extrusion (collar) of adjustable height. his extrusion serves to define the distance between fins (and consequently the total heat transfer surface) and to ensure perfect contact of the fins to the tubes. lternative fin materials are available upon request such as epoxy coated aluminium and or copper for applications in especially aggressive environments. Water heat exchanger ll units are equipped with a hell and ube water direct expansion type evaporator that has two separate cooling circuits, one for each independent refrigerant circuit. he casing is of steel and the internal tubes are of copper. here is an air vent valve, drain valve, probes for water temperature sensors, differential pressure switch and the whole heat exchanger is wrapped in a heavy insulation material appropriate for external installation. ir heat exchanger fans ll unit fans are of the axial type, single phase, 6 poles, internally protected against potential overheating, silent and suitable for outdoor installation. Due to the sophisticated aerodynamic design of the blades and inlet cones, as well as the perfect static and dynamic balancing, their operation is completely vibration-free. he fan-motor assembly has a protective grid against accidental contact with moving parts, which is designed according to IO regulations. Fan motors are of the external rotor type, aerodynamically shaped so as not to interfere with the airflow, and have permanently lubricated bearings that do not require servicing. Continuous linear fan speed regulation control is achieved according to coil temperatures including fan silent mode operation. his standard feature for Interklima MPC units saves energy and reduces sound levels dramatically, optimizing performance. MPC 00-06RB ñ R0c/croll

Microprocessor controller ll units are equipped with a sophisticated controller that combines intelligence with operating simplicity. he controller constantly monitors all machine parameters and precisely manages among others: ñ utomatic compressor control function through return water temperature. ñ Continuous fan speed control based on coil heat exchanger temperature. ñ ydraulic circuit pump control. ñ Compressor starting order control to reduce starting current. ñ Compressor operation control based on running time. ñ Compressor start up time delay function. ñ Compressor running time records. ñ Water pump running time records. ñ Over 0 programmable parameters. ñ Fan motor overload protection. ñ uto diagnostic stop function due to low water circulation high/low operating pressures, and compressor/pump thermal overload. ñ uto diagnostic function and digital display of approximately 0 possible error codes including thermistor faults. ñ Digital displays of inlet / outlet water as well as coil temperatures of each circuit. ñ Remote on/ off switch. ñ Remote alarm indication capability. ñ Phase sequence - phase failure - reverse phase and voltage monitoring. ñ Many optional control capabilities (listed in optional accessories). Optional accessories Microprocessor controller options ñ Remote keyboard. ñ Dynamic set point program via a -0ma proportional signal. ñ BM module interface kit for Modbus connection. ñ Parallel chiller operation with standard controller for up to units ( compressors). ñ Microprocessor parameter reprogramming card. Other unit accessories/option ñ Option of reciprocating,scroll, or tandem scroll compressor based on specification. ñ R0c or R refrigerant. ñ Condenser fins made of copper or prepainted aluminum, and Blygold treatment for corrosion protection. ñ Glycol application for low chilled water temperature down to o C. ñ Pressure relief valve on compressor discharge. ñ -meter, V-meter. ñ ydraulic module without buffer tank. ñ Water heat exchanger antifreezing electrical heater. ñ Compressor noise reduction jacket. ñ Compressor chamber noise reduction kit. Refrigerant circuit ll units have two separate refrigerant circuits one per compressor. Each circuit consists, depending on the size, of either a restrictor or thermal expansion valve. Other components fitted are a shut off valve, solenoid valve (0-06), large capacity filter dryer with a replaceable core or fixed one depending on the size, sight glass (0-06), and high / low pressure manometers. Unit protection is provided by a high-pressure switch with manual reset, and a low-pressure switch with auto reset. MPC 00-06RB ñ R0c/croll

. echnical specifications. MPC 00-06RB ype ominal cooling capacity Construction Compressor Quantity Capacity steps bsorbed power ominal operating current Maximum operating current Condenser Evaporator Quantity Water content Max. Operating pressure Connections ominal water flow Water pressure drop Minimum system water content Fan Quantity peed otal air flow bsorbed power ominal operating current Maximum operating current Electrical characteristics otal absorbed power ominal operating current Maximum operating current Compressor carter Power cables cross section per phase Fuses Voltage operating limits Refrigerant circuit umber of circuits Expansion device Refrigerant type oise level at m Dimensions hipping weight R Btu/h Material/Color l Water side bar Refrigerant side bar l/h kpa l rpm m /h mm V db() Width mm Length mm eigth mm kg MPC-00 8. 0.9 0.909.9..0 0 9 /" 6.60.0 0 800 6.0.. 6.0. 9.8 0.0 0.0 6 x0 00 6 00 MPC-0 MPC-0 MPC-09 6.. 9.0. 9.0 0.0 0 9 /" 8.0. 80 800 6.0.. 6.0.. 6.0 0. 6 x0 00 6 00 60.0. 8.09 Galvanized steel / Light grey-beige (RL 900) CROLL 6. 0.6. 0 9 /" 9.88 9. 800.0.. 6.0. 6.0 0.0 0. 6 x6 00 6 00 60 66. 8.8.68 0.. igh capacity cross finned coil with internally grooved tubes and louver fins hell and ube Electric network 00 V/Ph/0z 60-0V Restrictor R0c 6.0 0 9 /".86 6. 9 800.00.8 8. 9.0..6 6.0 0. x6 00 68 00 0 6 MPC 00-06RB ñ R0c/croll

ype ominal cooling capacity Construction Compressor Quantity Capacity steps bsorbed power ominal operating current Maximum operating current Condenser Evaporator Quantity Water content Max. Operating pressure Connections ominal water flow Water pressure drop Minimum system water content Fan Quantity peed otal air flow bsorbed power ominal operating current Maximum operating current Electrical characteristics otal absorbed power ominal operating current Maximum operating current Compressor carter Power cables cross section per phase Fuses Voltage operating limits Refrigerant circuit umber of circuits Expansion device Refrigerant type oise level at m Dimensions hipping weight R Btu/h Material/Color l Water side bar Refrigerant side bar l/h kpa l rpm m /h mm V db() Width mm Length mm eigth mm kg MPC-0 80.9.0.9.6. 6 8. 0 9 /".9 8. 8 800.090.8 8. 9.0 6...0 0. x80 6 00 68 00 0 MPC-09 MPC-0 MPC-06 0. 0. 6.9.. 80.0 0 9 " 8.6 9. 6 800 9.0. 0.8.0.9 66. 9.0 0. 0 x00.6 8.0. Galvanized steel / Light grey-beige (RL 900) CROLL 0. 0. 0. 0 9 ".99. 80 6 800.860. 6. 8.0.8 86..0 0. 0 x60 hermal expansion valve R0c 6 68 90 90 600 06 60 60.0.0 6..0 6 8. 8. igh capacity cross finned coil with internally grooved tubes and louver fins hell and ube Electric network 00 V/Ph/0z 60-0V. 0 9 D00 8.. 99 6 800.860. 6. 8.0.6 99..0 0. 9 x60 69 90 06 60.0 OE ominal conditions are as follows entering/leaving chilled water temperature / o C; ambient o C DB electrical installation specifications are purely indicative and non-binding, all connections to the system and the electrical installation must be in full accordance with all applicable national and local codes. MPC 00-06RB ñ R0c/croll

MPC 00-06RB ñ R0c/croll 8. Capacity tables MPC-00 MPC-0 MPC-0 MPC-09 MPC-0 MPC-09 MPC-0 MPC-06 Water outlet ÆC Cooling capacity bsorbed power Current bsorbed power Current Cooling capacity bsorbed power Current Cooling capacity bsorbed power Current Cooling capacity bsorbed power 0 0 Current Cooling capacity 0 0 0 0 0 0 0 0 0.. 9. 8.8. 9.0 6.6 6.0 68. 69..0 8. 8. 9. 0..8. 6...9.. 8.9 0.9 9. 9. 9.....9.8.8 6. 6. 6. 9. 9. 9..9.9 6.0..6.9 8.6 8.8 9..8.8.8.9.9.9 6. 6. 6. 0. 0. 0....0 6. 6.8.0 60. 60. 60.8 0. 0.8..8.0 6. 6.0 9.... 6. 6. 0.6 9.0 9.9 86. 96. 06.. 8..8.9 6. 6. 6.9 98.8 0.6 0. 0..8.8.... 8. 8. 8..8.8.8 8.9 9.0 9. 6.0 6. 6..9...9.9.9... 8. 8. 8....8 0.0 0.0 0.0 0.6 0. 0.9 6. 6.8 6. 6. 6.6.0. 8... 6.. 0.0.0 60. 6. 66...9 80.9 90. 99. 0. 0...6 0.. 6. 86..0.9.9... 6. 6. 6. 0. 0. 0..6.6.... 0. 0. 0. 8.0 8. 8.... 9.0 9.0 9.0 0.6 0. 0....6...... 0.0 0. 0. 8. 8. 8.9.0.9 0. 0.. 8.9 6. 0. 6..0 6. 69. 69.8. 8. 9.8 99.6... 9. 0.6.9.8.6.. 6. 6. 6. 8. 8. 8.....9.8. 6. 6. 6.....8.9. 6. 6. 6..0.0 0.9...0 8.8 8.8 8.9... 60. 60.8 6.0 6. 6. 6.6 9.6 9. 9.0 0.6... 0...0 6.6..6.0 6. 6.6 69.9 8.6 8. 9.6 0. 0..6.6. 9. 8.... 8.0 8.0 8. 0.6 0. 0. 6.0 6.0 6.... 0.9.0. 0.9 0.9 0.9 60. 60. 60.6 8. 8. 8.... 6.0 6.0 6.0.6..8.9.9.0 6. 6. 6. 8. 8. 8. 0. 0. 0. ype mbient temperature o C Cooling capacity table for MPC 00-06RB OE Bold values show nominal cooling capacities. bsorbed power and current refers to the compressor. bove figures are valid for water t = o C.

. Water pressure drop curves MPC 00-06RB PD 00 90 80 0 60 0 6 0 kpa 0 0 0 0 0 I/h 0 0 0 60 0 WF 80 00x0 OE PD: pressure drop WF: water flow rate. MPC 00-0RB. MPC 0RB. MPC 09RB. MPC 0RB. MPC 09RB 6. MPC 0RB. MPC 06RB EYLEE GLYCOL CORRECIO FCOR % EYLEE GLYCOL BY VOLUME Freezing point o C Output duty Input power Equivalent Flow rate L/ Equivalent Pressure drop kpa UI 0-0,99 0,99,0,06 0-9 0,98 0,98,0, 0-0,9 0,98,08,8 0-0,96 0,9,, MPC 00-06RB ñ R0c/croll 9

. Operation range O Outdoor emperature ( CDB) OE Protect the water circuit against freezing 0-6 Leaving water temperature( o C) - he accompanying operating limits are for general guidance only. It may be possible for certain units to operate outside the confines of the graph. Please contact Interklima if further clarification is required. - For operation with leaving water temperature below 6 o C it is required to confirm with Interklima at the time of order and the addition of glycol into the system. 6. ound data ype Octave band center frequency (z) MPC-00 MPC-0 MPC-0 MPC-09 MPC-0 MPC-09 MPC-0 MPC-06 Power Pressure @ m Pressure @0 m Power Pressure @ m Pressure @0 m Power Pressure @ m Pressure @0 m Power Pressure @ m Pressure @0 m Power Pressure @ m Pressure @0 m Power Pressure @ m Pressure @0 m Power Pressure @ m Pressure @0 m Power Pressure @ m Pressure @0 m db() 66 6 6 6 69 9 8 0 0 89 8 6 90 8 6 9 8 6 6 8 0 0 8 0 0 8 0 0 9 9 80 8 8 0 6 0 6 0 6 6 6 8 8 6 6 8 0 6 6 6 6 6 9 80 8 00 6 6 6 6 6 9 9 8 000 6 6 6 6 6 8 86 8 8 8 9 9 000 6 6 6 6 6 66 8 8 6 9 80 8 000 6 8 8 8 0 0 8 0 0 8 0 0 9 66 6 66 6 66 6 8000 9 9 9 9 0 0 66 8 8 6 9 9 66 8 8 0 MPC 00-06RB ñ R0c/croll

. Outlook drawings. MPC 00-0RB YPE B C MPC-00 90 6 0 MPC-0 90 6 0 MPC-0 00 90 0 9 00 00 C 00 60 B 6. MPC 09-0RB YPE B C MPC-09 90 096 MPC-0 80 80 00 68 00 00 C 00 60 B 68 MPC 00-06RB ñ R0c/croll

. MPC 09RB 60 60 90 00 6 0 600. MPC 0-06RB YPE B C MPC-0 0 608 MPC-06 00 0 80 90 60 C 90 00 B 06 MPC 00-06RB ñ R0c/croll

8. Refrigerant circuit diagrams 8. MPC 00-09RB 8. MPC 0RB 6. 6. OE. Compressor. hell and tube heat exchanger. Condenser coil. Filter dryer. Expansion device (restrictor). Expansion device (hermal expansion valve) 6. olenoid valve MPC 00-06RB ñ R0c/croll

8. MPC 09-06RB 6.. 6 8 8 OE. Compressor. hell and tube heat exchanger. Condenser coil. Filter dryer. Expansion device (restrictor). Expansion device (hermal expansion valve) 6. olenoid valve. ight glass 8. hut off valves MPC 00-06RB ñ R0c/croll

9. Wiring diagrams 9. MPC 00-0RB FROM POWER CIRCUI L L L REMOE O-OFF COROL CIRCUI Off O FF EMI FILER F F VC V RFORMER C LL GD CDC K C GD ID ID LP L P ID ID ID LP L P C C EERGY 00 GD GD K ID0 ID9 C W ID ID8 FLOW WIC F F 6 ID F ID6 C 0V F C P P P P F C F F Ltc, LF 6 8 9 0 - + C C FM FM CC CC PUMP ERML P C L L 9. MPC 09-0RB FROM POWER CIRCUI L COROL CIRCUI L L REMOE O-OFF Off O FF EMI FILER F F VC V RFORMER 0V C LL GD CDC K C GD ID ID LP L ID ID ID P LP L P C C EERGY 00 GD GD K ID0 ID9 C W ID ID8 F FLOW WIC F 6 ID F F ID6 C F F C P P P P Ltc, F F F C CC CC LF 6 8 9 0 - + v v C V V FM C C FM FM CC CC PUMP ERML P C L L MPC 00-06RB ñ R0c/croll

9. MPC 09RB L L L FROM POWER CIRCUI FF EMI FILER FF EMI FILER F 0V F V VC C LL GD C DC K GD ID COROL CIRCUI REMOE O-OFF OFF O ID L ID ID L ID C LL GD C DC K GD ID0 C ID9 F ID ID8 6 ID ID6 + F F _ F COROL F LF F COROL F LF C LP P LP P C P P P P W F F C C EERGY 00 C C C C FM FM FM FM CC CC 6 8 9 0 V V Ltc Ltc L L V V C CC CC P 9. MPC 0-06RB FROM POWER CIRCUI L L L FF FF F F VC C C LL GD DC K GD ID COROL CIRCUI REMOE O-OFF OFF O ID ID ID ID C LL GD C DC K GD ID0 C ID9 ID ID8 6 ID ID6 + EMI FILER EMI FILER 0V V L L F F F _ F F COROL COROL F F LF LF C LP P LP P C P P P P W F F6 F F C EERGY 00 FM FM FM FM FM FM6 V V L L V V C CC C CC CC 6 8 9 0 Ltc CC Ltc P 6 MPC 00-06RB ñ R0c/croll

9. MPC 00-06RB L L L M POWER CIRCUI Mp PE FC FC FC CC FC CC VC CC CC U V W U V W C C C C CM CM LEGED F COROL CIRCUI BREKER F LOW VOLGE ( V) CIRCUI BREKER FF CIRCUI F CIRCUI BREKER FF CIRCUI F CIRCUI BREKER F, CODEER F PEED COROLER VC VOLGE URVEYOR CC COMPREOR COCOR CC COMPREOR COCOR V CIRCUI LIQUID LIE OLEOID VLVE V CIRCUI LIQUID LIE OLEOID VLVE C COMPREOR ERML PROECIO C COMPREOR ERML PROECIO F CODEER F ERML PROECIO P IG PREURE PREO CIRCUI LP LOW PREURE PREO CIRCUI P IG PREURE PREO CIRCUI LP LOW PREURE PREO CIRCUI EERIG WER EMPERURE EOR LEVIG WER EMPERURE EOR CIRCUI COIL EMPERURE EOR CIRCUI COIL EMPERURE EOR R RFORMER 0/V C FM CODEER F FM CODEER F FM CODEER F FM CODEER F FM CODEER F FM6 CODEER F 6 ª GEERL CIRCUI BREKER Cª COMPREOR Cª COMPREOR FC COMPREOR CIRCUI BREKER FC COMPREOR CIRCUI BREKER FC COMPREOR CRKCE EER CIRCUI BREKER C CRKCE EER COMPREOR C CRKCE EER COMPREOR LC 0 V FOR COMP. ERML PROECIO LC 0 V FOR COMP. ERML PROECIO C-P PUMP COMMD (0 V C) - PUMP ERML PROECIO (DRY COC) F-W DIFF. WER PREURE WIC O-OFF REMOE O-OFF WIC (DRY COC) L-L LRM IGL (DRY COC) PUMP COMMD (0 V C) PUMP ERML PROECIO DIFFEREIL WER PREURE WIC REMOE WIC O-OFF COMMD 0 V FOR I FREEZE EER (OPIOL) 0 V C LRM IGL (.O. COC) EERIG WER EMP.EOR () LEVIG WER EMP. EOR () CIRCUI COIL EMPERURE EOR () CIRCUI COIL EMPERURE EOR (6) F ERML PROECIO F ERML PROECIO F ERML PROECIO F ERML PROECIO F ERML PROECIO F 6 ERML PROECIO COMPREOR ERML PROECIO COMPREOR ERML PROECIO IG PREURE PREO CIRCUI LOW PREURE PREO CIRCUI IG PREURE PREO CIRCUI LOW PREURE PREO CIRCUI 0 V FOR ERML PROECIO COMP. CIRCUI LIQUID OLEOID VLVE CRKCE EER COMPREOR 0 V FOR ERML PROECIO COMP. CIRCUI LIQUID OLEOID VLVE CRKCE EER COMPREOR C P F W O OFF L L F C C P L P P L P F F F F F6 LC V C LC V C 0 V C LRM E00: REMOE O/OFF I OFF POIIO E0: IG PREURE CIRCUI E0: LOW PREURE CIRCUI 0: ERML PROECIO COMP. E0: ERML PROECIO WIC COD.F E06: PROBE FUL (WER OULE) E0: PROBE FUL (COIL ) : ERML PROECIO WIC COMPREOR E: IG PREURE CIRCUI E: LOW PREURE CIRCUI E: PROBE 6 FUL (COIL ) E0: PROBE FUL (WER ILE) E: DIFFEREIL WER PREURE WIC FIELD COECIO W O OFF C P F L L V V MPC 00-06RB ñ R0c/croll

0. Installation 0. election of location - service space he MPC-RB unit should be installed in a location that meets the following requirements:. he foundation is strong enough to support the weight of the unit, and the floor is flat to prevent vibration and noise generation.. he space around the unit is adequate for servicing and the minimum space air inlet and air outlet is available. If several units are being installed side by side in parallel, the minimum service space between them must be taken into account.. here is no danger of fire due to leakage of inflammable gas.. Ensure that water cannot cause any damage to the location in case it drips out the unit.. Make sure that the air inlet and outlet of the unit are not positioned towards the main wind direction. Frontal wind shall disturb the operation of the unit. If necessary, use a windscreen to block the wind. 6. In heavy snowfall areas, select an installation site where snow shall not affect operation of the unit.. Make sure that the unit can be fixed directly on concrete. 8. In order to avoid the transmission of vibration from the operating unit to its carrying structure, the use of antivibration material to install under the supports of the unit is recommended. It is suggested to install a rubber pad between the points of support and the base of the unit, or spring antivibration mounts under each point of support of the unit. 000mm 000mm 000mm 00mm 000mm 0. Centre of gravity ªPC 00-0RB 0 80 8 MPC 00-06RB ñ R0c/croll

ªPC 09-0RB 0 00 ªPC 09RB 9 00 ªPC 0-06RB 9 0 MPC 00-06RB ñ R0c/croll 9

0. Recomendations concerning the hydraulic circuit ñ ll field connections must be carried out by a licensed technician and must comply with the applicable local and national codes ñ Evaporator water connections should be made in accordance with the unit outlook respecting the water inlet and outlets ñ Water piping to be arranged so that the circulating pump discharges directly into the evaporator ñ Install a flow switch or water differential pressostat (standard component) in the water outlet piping to prevent the unit from operating at a water flow, which is too low. terminal is provided in the switch box for the electrical connection of the flow switch in the control circuit. ñ o avoid erosion, it is recommended to install a filter in the water inlet pipe. ñ It is essential to install a thermometer in the water inlet/ outlet pipe to check temperatures. ñ Provide heat insulation with suitable vapour barrier around the chilled water piping to prevent condensation and capacity loss. ñ Provide drain connections at all low points of the system to permit complete drainage for maintenance and/ or shutdown. ñ ir vents should be provided at all high points in the system located where they are easily accessible for servicing. he water inlet pipe is specially designed to obtain a complete air purge of the evaporator. ñ Install an expansion tank on the suction side of the water pump so that the water pressure on the pump suction shall be positive. ñ o avoid frequent on/off operation of the compressor, a minimum water volume is required in the system (table 0.). ñ o assure proper operation of the unit, the water flow through the evaporator must be within the specified limits in (table 0.). MPC 6 6 9 0 8 Example with one central pump 8 0 MPC 00-06RB ñ R0c/croll

MPC 6 6, 6, 6, 6 9 0 8 8 Example with internal loop pump and external zone pumps OE. Flexible. hermometer. Manometer. ir vent. hut off valve 6. Pump (primary circuit) 6. Pump (secondary circuit). Water filter 8. Drainage 9. Flow switch (optional) 0. Balancing valve. Buffer tank. Electric resistance. utomatic make up water valve. Expansion membrane. Check valve 6. afety valve MPC 00-06RB ñ R0c/croll

0. Watercharge, flow and quality o ensure proper operation of the unit, a minimum water volume is required in the system and the water flow must be within the operation range as specified in the table. MPC-00RB MPC-0RB MPC-0RB MPC-09RB MPC-0RB MPC-09RB MPC-0RB MPC-06RB Minim um water volume (l) 0 80 9 8 6 80 99 Minim um water flow (l/h) 8 09 660 866 09 0 ominal water flow (l/h) 660 80 988 86 9 86 99 8 Maxim um water flow (l/h) 86 00 60 9 00 8 0 Be sure the water quality is in accordance with the specifications below OE he above tables are purely indicative and non-binding Items Items to be controlled: P Ô C lectrical conduct (m/m) at Ô C Chloride ion (mg CI-/I) ulfate ion (mg O //I M-alkalinity (ph.8) (mg O/I) otal hardness (mg CaCO/I ) Calcium hardness (mg CaCO/I) ilica ion (mg io/i Items to be referred to: Iron (mg Fe/I) Copper (mg Cu/I) ulfide ion (mg -/I) monium ion (mg +/I Remaining chloride (mg CI/I) Free carbide (mg O/I) tability index Circulating water 0C Evaporator water 6.8-8.0 below 0 below 0 below 0 below 0 below 0 below 0 below 0 below.0 below.0 ot detectable below 0. below 0. below 0. - upply water 6.8-8.0 below 0 below 00 below 0 below 0 below 0 below 0 below 0 below 0. below 0. ot detectable below 0. below 0. below.0 - Circulating water 0C-60C.0-8.0 below 0 below 0 below 0 below 0 below 0 below 0 below 0 eated water below.0 below.0 ot detectable below 0. below 0. below 0. - upply water.0-8.0 below 0 below 0 below 0 below 0 below 0 below 0 below 0 below 0. below.0 ot detectable below 0. below 0. below.0 - endency if out of criteria corrosion + scale corrosion + scale corrosion corrosion scale scale scale scale corrosion + scale corrosion corrosion corrosion corrosion corrosion corrosion + scale 0. Operating pressure of the refrigerant circuit It is important to check the high and low pressure of the refrigerant circuit to ensure the proper operation of the unit and to guarantee that the rated output shall be obtained. ttention: he pressures measured shall vary between a maximum and minimum value, depending on the water and ambient temperatures at the moment of measurement. Cooling mode (region) low pressure high pressure Minim um (outdoor temp. Ô ominal Maximum CDB) (leaving water temp 6 Ô (outdoor temp. CDB) C) (leaving water temp, Ô (outdoor temp. 8 Ô CDB) C) (leaving water temp, Ô C),- bar -9 bar - bar - bar,-6 bar -6 bar MPC 00-06RB ñ R0c/croll

0.6 Digital controler User interface MPC 00-06RB he interface on the front panel can be used to carry out all the operations connected to the use of the instrument, and in particular to: et operating mode Check the state of resources Respond to alarm situations 0.6. Keys Front panel of the instrument elects operating mode (eating/defrost refers only to MPC- series): If the heating mode is enabled, each time the key is pressed the following sequence occurs: tand-by Cooling eating tand by If cooling mode is enabled: eating tand-by Cooling eating tand by In menu mode, this key acts as a CROLL UP or UP key (increasing value). Resets alarms, and turns the instrument on and off. Press once to reset all manually reset alarms not currently active. old down the key for seconds to turn the instrument from on to off or vice versa. When it is off, only the decimal point remains on the display. In menu mode this key acts as a CROLL DOW or DOW key (decreasing value). Pressing the mode and on-off keys at the same time. If you press both keys at the same time and then release within seconds, you shall move one level deeper in the display menu. If you press both keys for more than seconds you shall move one level up. If you are currently viewing the lowest level in the menu and you press both keys and release within seconds, you shall go up one level. 0.6. Displays 0.6.. Display ormal display shows: ñ Regulation temperature in tenths of degrees celsius with a decimal point, or in degrees fahrenheit without a decimal point. ñ he alarm code, if at least one alarm is active. If multiple alarms are active, the one with greater priority shall be displayed, according to the able of larms. ñ If temperature control is not analogue and depends on the status of a digital input ( or configured as digital inputs), the On or Off label shall be displayed, depending on whether temperature control is active or not. ñ When in menu mode, the display depends on the current position; labels and codes are used to help the user identify the current function. ñ Decimal point: when displaying hours of operation, indicates that the value must be multiplied x 00. 0.6.. Led Led compressor. O if compressor is active OFF if compressor is off Rapid BLIK if safety timing is in progress low BLIK if compressor is currently set to defrost (heat pump version) Led compressor. O if power step is active OFF if power step is not active Rapid BLIK if safety timing is in progress low BLIK if step is currently defrosting Led compressor. O if power step is active (compressor ). OFF if power step is not active Rapid BLIK if safety timing is in progress low BLIK if step is defrosting Led compressor. O if power step is active OFF if power step is not active Rapid BLIK if safety timing is in progress low BLIK if step is defrosting MPC 00-06RB ñ R0c/croll

Defrost led (heat pump version) O if defrosting is in progress OFF if defrosting is disabled or has been completed BLIK if timing is in progress (defrost interval) 0. Remote keyboard he remote keyboard on the display is an exact copy of the information displayed on the instrument, with the same leds; Electrical heater/boiler led O if the internal anti-freeze electrical heater or boiler is on OFF if the internal anti-freeze electrical heater or boiler is off eating led (heat pump version) O if the device is in heating mode Cooling led O if the controller is in cooling mode If neither the EIG led nor the COOLIG led is on, the controller is in D-BY mode It performs exactly the same functions as those described in the display section.he only difference is in use of the UP and DOW keys (to increase and decrease value), which are separate from the MODE and O/OFF keys. Connection with the controller is illustrated below: PCB COROL BORD + - BCK VIEW REMOE 6 + - MPC 00-06RB ñ R0c/croll

. Guide specifications MPC 00-06RB he supply, transport to jobsite, installation, commissioning and start up of an air cooled water chiller with the following technical characteristics. he unit shall be factory assembled, charged with R0c refrigerant and factory tested. he capacity of the unit shall be no less than: mbient air temperature (DB) Entering water temperature Leaving water temperature ÆC ÆC ÆC he unit shall operate unhindered within 6 to ÆC water outlet temperature,. to ÆC water temperature difference and up to ÆC ambient air temperature. he structural requirements shall be the following: UI OUIG he unit housing shall be fabricated from heavy gauge galvanized steel sheets, formed to ensure maximum rigidity that shall guarantee and preserve the unit operation during the years. ll metal parts after fabrication shall be degreased phosphatized, and electrostatically powder coated with epoxy- polyester RL 900 coating of a thickness of 60-0 m. he corrosion resistance treatment must successfully withstand a salt spray test of 00 hours, according to M B-. ll components shall be assembled exclusively together using bolts, without welding. he unit shall have removable access panels, designed in such a manner as to permit easy access to internal compartments only by authorized personnel. Electrical and electronic equipment and components for proper unit operation shall be located in a weather proof (IP ) electrical panel with access via a special key. COMPREOR hall be of the hermetically sealed scroll type, with low noise and vibration levels, specially optimized for use with R0c refrigerant. hey shall be equipped with a crank case electrical heater, to separate refrigerant and oil when the unit is not operating. hey shall also include internal protection against overloading or electrical spikes. he compressor shall be mounted on special anti vibration rubber mounts to absorb and eliminate any vibration that can be generated from the unit base. IR E EXCGER he air hear exchangers shall be manufactured from seamless copper tubes and an outside diameter of 9.mm (/8'') of high quality according to M B 80. he tubes shall be internally grooved to achieve optimized heat transfer between refrigerant and tube. he fins shall be manufactured from aluminium. he fins shall be continuous across the heat exchanger and the fin surface shall be waffle formed and louvered so as to increase the fin rigidity and heat transfer. he combination of internally grooved copper tubing and louvered fins must result in a heat transfer performance 0% superior to that of a conventional coil. he assembly of the finned pack shall be achieved by mechanical expansion in such a way as to form a perfect mechanical bond with the fins. For this purpose, the fin holes shall have a peripheral extrusion (collar). WER E EXCGER ll units shall be equipped with a hell and ube water direct expansion type evaporator that has two separate cooling circuits, one for each independent refrigerant circuit. he casing shall be of steel and the internal tubes of copper. here shall be an air vent valve, drain valve, probes for water temperature sensors, differential pressure switch and the whole heat exchanger shall be wrapped in a heavy insulation material appropriate for external installation. IR E EXCGER F he unit shall be equipped with axial type fans, single phase, and 6 poles, internally protected against potential overheating, noiseless and suitable for outdoor installation. he design of the blades and inlet cones shall be aerodynamic, and the fan motor assembly shall be perfectly statically and dynamically balanced allowing a completely vibration free operation. he fan motor assembly shall have a protective grid against accidental contact with moving parts according to IO. he fan motor shall be of the external rotor type with permanently lubricated bearings that do not require servicing. he motor shall be aerodynamically shaped so as not to interfere with the airflow. he unit shall be equipped with a continuous linear fan speed regulation control according to coil temperature. COROL YEM WI MICROPROCEOR COROLLER he control system shall possess a sophisticated controller that shall constantly monitor all machine parameters and particularly manage among others: ñ utomatic compressor control function through return water temperature. ñ Continuous fan speed control based on coil heat exchanger temperature. MPC 00-06RB ñ R0c/croll

ñ ydraulic circuit pump control. ñ Compressor start up time control function. ñ Compressor running time records. ñ Over 0 programmable parameters. ñ Fan motors overload protection. ñ uto diagnostic stop function due to low water circulation, high / low operating pressures and compressor thermal overload. ñ uto diagnostic function and digital display of approximately 0 possible error codes including thermistor faults. ñ Digital displays of inlet/outlet as well as condensing temperatures of each circuit. ñ Phase sequence phase failure - reverse phase and voltage monitoring device. ñ Remote cool/ heat and on / off selection. ñ Various other optional control capabilities (listed in options). REFRIGER CIRCUI he unit shall have two refrigerant circuits one per compressor. he circuits depanding the size shall consist of a filter dryer with replacable core, expansion device, solenoid valve, sight glass, shut off valves, high pressure switch with manual reset and a low pressure switch with auto reset. OE he consultant may if required add the below mentioned optional accessories / functions. ñ Remote keyboard. ñ Dynamic set point program via a 0 m proportional signal. ñ BM module interface kit for modbus connection. ñ Parallel chiller operation with more than units with optional controller. ñ Microprocessor parameters reprogramming card. ñ Condenser fins made of prepainted aluminum or copper, and blygold treatment for additional corrosion protection. ñ hell and tube exchanger-freezing protection for low chilled water temperature controlled by microprocessor. ñ Glycol for low chilled water temperatures. ñ Pressure relief valve on compressor discharge. ñ ydraulic module without buffer tank. ñ Compressor chamber noise reduction. ñ Compressor noise reduction jacket. 6 MPC 00-06RB ñ R0c/croll

Engineering Data 006 Products are manufactured in IO 900:000 certified factories. IO 900:000 pertains to quality assurance regarding design, development, manufacturing and installation of products as well as to services related to the product. Interklima units comply with the European regulations that guarantee the safety of the product pecifications subject to change without notice IERKLIM PRODUC RE DIRIBUED BY: EGB-B---0/06