FIRE STOP 200/30. High technology system for first attack of fire with high pressure nebulized water (Water mist) FD 907. Ed.

Similar documents
MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle.

Fire fighting with fast deployment units. CRISTANINI Spa Via Porton 5, Rivoli Veronese, ITALY

SPECIAL HAZARDS THE MOST ADVANCED TECHNOLOGY FOR PROTECTING

Ceasefire Watermist Hydrant Systems

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle. TM TM

Fire Safety. Presenter, Kevin V Coleman September 14 th 2016

Basic Fire Safety Awareness Training.

PRO JET RANGE FOR A PRODUCTIVE, CLEAN & HEALTHY WORK ENVIRONMENT

So what is a fire hazard?

What is HI-FOG? The natural enemy of fire

Institute for Plasma Research Welcomes you all on

& Fire Extinguisher Training

Dual Agent Unit w / Atmospheric Tank 200 Litres DAHR 01

Level 2 Award in Fire Safety (QCF) (SCQF Level 5 in Scotland) Unit 1 title: Fire safety principles

Tel Web: dyayan.com

Element C3.4 Fire Fighting Equipment

The Combustion Process THE FIRE TETRAHEDRON FUEL TEMPERATURE

Fire is No Accident Fire is No Accident It can be prevented.

DRY POWDER FIRE EXTINGUISHER (Stored Pressure) ABC TYPE - PORTABLE

PORTABLE FIRE EXTINGUISHERS. Fire Safety.

FIRE AND FIRE FITTING By Mr. Prashant Sansare

Why is this important?

Title: Fire Protection Effective Date: 7/1/2013 Control Number: THG_0039 Revision Number: 1 Date: 10/23/2015 Annual Review Completed: 5/13/2015

Employers Responsibilities

Fire fighting Questions

Safety is more than just being careful: it

KRISHNAMURTI FOUNDATION TRUST FIRE SAFETY POLICY. Last Review Date 30 June Next review date 30 August Health and Safety Officer

K Air Con. Induction motor regulation and swivel-mounted joint. Vario Power Jet Short 360 with infinitely variable pressure

Fire Safety & Evacuation Procedures

"USING FIRE EXTINGUISHERS"

w-fog RG-SYSTEMS W-FOG WATER MIST CO-OPERATI

Foam Products ENGLISH

National Fire Authority

RE: BASIC FIRE SAFETY PROCEDURES AND OPERATION OF FIRE EQUIPMENT

INSTRUCTOR GUIDE COURSE: FIREFIGHTER PRE-BASIC SESSION REFERENCE: 1 TOPIC: ORIENTATION AND FIRE BEHAVIOR LEVEL OF INSTRUCTION:

Fire protection for buildings

DSEAR - Requirements

PHIREX AUSTRALIA. FOGEX & MISTEX WATER MIST FIRE PROTECTION

Ceasefire Automobile Firefighters

AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS

To understand FIRE and how to EXTINGUISH it, we first need to know: What is FIRE?

Using Fire Extinguishers. Leaders Guide and Quiz

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

INDEPENDENT FIRE EXTINGUISHER SALES & SERVICES. Your First Line of Defense Since 1971

FIRE TETRAHEDRON. Consists of 4 Sides. Oxygen. Fuel. Chain of reaction

INFRARED PARAFfIN / KEROSENE / model No: ir20.v2 1. SAFETY INSTRUCTIONS RECOMMENDED FUSE RATING: 5AMP

Three elements of fire. Heat Oxygen Fuel. Remove one of the three and the fire is extinguished.

MB05. RESPOND TO EMERGENCIES BASIC KNOWLEDGE OF EMERGENCY PROCEDURES, INCLUDING EMERGENCY SHUTDOWN

Exploration and extraction can be on land or on offshore platforms. Once extracted, ground transportation is done by means of oil or gas pipelines,

PLUS SIZE EXTINGUISHERS CEASEFIRE PLUS

FIGHTING FIRE as easy as blowing out a match

Portable Fire Extinguishers

Mist-Tech Fire Fighting Equipment

Fire Safety Plan (FSP) Review Checklist 1

Fire Safety Plan (FSP) Review Checklist 1

International Safety Guide Chapter 30 for Inland Navigation Tank-barges and Terminals. Chapter 30 FIRE-FIGHTING

City of Cleveland. Division of Fire Fire Prevention Bureau 1645 Superior Avenue Cleveland, Ohio Standard Operating Procedure 18

Fire Safety PPT-SM-FIRESFTY V.A.0.0

A full range of UK manufactured portable and wheeled fire extinguishers

With combustion engine HD 801 B. Equipment: Trigger gun Extended highpressure. Technical data

automatic FiReFighTing SYSTeMS in PainT booths

Fire Risks in our Woodshops. Sam Altshuler January 2018

Safe working with flammable substances

Aluminum Dust Management in a Metallizing Facility

FKO KOM4T PRODUCTS RANGE FKO KOM4T 1.6 FOAM FKO KOM4T 5.6 FOAM - 1.6kg package based on - 5.6kg package based on a foam fluid

SUPPRESSION SALES I INSTALLATION I SERVICE

Cold water compact class HD 5/12 C Plus

SECURITY BLANKET Foam Fire Protection Products

Technical Ventilation

Amerex Fire Suppression Systems. Because Operators and the Environment are NOT Disposable Quality is Behind the Diamond.

E4218 Fire Extinguisher Basic Training. Leader s Guide

HD 7/11-4 Cage Classic

Fire Suppression Systems

Essentials of Fire Fighting, Fourth Edition Transition Guide. Chapter 1: The History of the Fire Service (Essentials, Chapter 1)

Fire protection on chemical manufacturing sites

Design and Supply of Fire Equipments. External Fire Fighting Systems.

STORED PRESSURE YES TEST STANDARDS: CAN/ULC S504 & ANSI/UL 229 CAN/ULC S508 & ANSI/UL 711. Available Options: Stationary Design Tow Loop

Safe Fire Extinguisher Use

FIRE EXTINGUISHERS: UNDERSTANDING FIRE EXTINGUISHERS DEFINITIONS, DESCRIPTIONS, SIZES, TYPES, CLASSES AND MEDIUMS

Case study: EconAqua water mist sprinkler system

IMO. Resolution A.951(23) Adopted on 5 December 2003 (Agenda item 17) IMPROVED GUIDELINES FOR MARINE PORTABLE FIRE EXTINGUISHERS

Lamorinda CERT - Unit 2 09/15/2016

Fire Safety Handbook

Fire Extinguisher Training

"FIRE PREVENTION IN HEALTHCARE FACILITIES"

Ensuring safe passage HI-FOG for underground stations

Risk Management Department. Fire Extinguishers

INFRARED PARAFFIN/KEROSENE/ DIESEL HEATER 28/37kW 230V

What are the four things that must be present at the same time to produce fire?

The Nilfisk range of ATEX-certified vacuum cleaners

INNOVATIVE TECHNOLOGY OF FIRE PREVENTION

HOT WASHER MODEL NO: KING150

Fire Safety. Version 1.0

Operation Refilling and Maintenance Manual SFS-10. Hatsuta Seisakusho Co. Ltd. SFS-10-E1404-(A-012)

HOW TO USE YOUR 2500 RANGE L.P.G. COOKER OR HOB UNIT

Cadet Entry Level Award(ELA) Part Four. Fire Safety

Ceasefire s Watermist Compressed Air Foam System. 400 times more power.

Dangerous Goods Logistics

Fire Protection in High-rise Buildings

GUIDELINES FOR THE APPROVAL OF HELICOPTER FACILITY FOAM FIRE-FIGHTING APPLIANCES

Transcription:

NCAGE A5009 CONFORM TO THE QUALITY SYSTEM STANDARD AQAP 2110 and ISO 9001:2008 FD 907 Ed. 07/2016 FIRE STOP 200/30 High technology system for first attack of fire with high pressure nebulized water (Water mist)

FIELDS OF APPLICATION - SHOPPING MALLS AND SHOPS - CINEMAS AND THEATRES - WAREHOUSES AND PRODUCTION DEP. - HOMES AND HOTELS - HOSPITALS - PLACES OF WORSHIP - GARAGES - AIRPORTS - SHIPS AND OFFSHORE PLATFORMS - CONCERTS AND EVENTS WITH PUBLIC PERFORMANCES - NEIGHBOURHOOD MARKETS - MAJOR RELIGIOUS EVENTS - CAR AND MOTORCYCLING RACES - CAMPSITES - PORTS - FOREST - ETC. 2

CHARACTERISTICS OF USE RAPID, LIGHT AND EASY TO USE The FIRE STOP 200/30 is the most suitable response for first attack fire fighting in any environment, as its extinguishing capacity is much higher than all the classic extinguishing systems. The reduced overall size allows transport with small vehicles, making it absolutely versatile to use in all environments that are hard to reach with normal emergency vehicles. Thanks to its capacity of use, the FIRE STOP 200/30 can be used by anyone and in particular by workers appointed for fire prevention and fire fighting now present in all companies. It is so practical that it can be used by only one operator. The successful system of the FIRE STOP 200/30 is thanks to the Water Mist technology. At high pressure, the water is pulverized forming millions of micro-particles, the effect of which is to smother the fire and cool down the combustible. EXTINGUISHING CAPACITY The FIRE STOP 200/30 has a very high capacity of extinguishing fire, well above all the traditional extinguishing systems. It can be used in: - Fires of solid and liquid flammable material of categories A, B and C. - Activities with particular requirements, complementary to a hydrant system. - Environments at a specific risk with the presence of hazardous substances. - Activities subject to visits and inspections of fire prevention and companies at the Risk of Significant Accidents. 3

THE WATER MIST TECHNOLOGY Normally the fire is schematized by a triangle with the sides representing the 3 elements necessary for combustion. The 3 elements are: - THE COMBUSTIBLE - THE COMBURENT (oxygen) - THE SPARK AND THE HEAT THAT FOLLOWS ON THE REACTION oxygen (air) combustible spark The principle underlying all classic extinguishing systems is the elimination of at least one factor that contributes to combustion. For example, water cools down the combustible then removes the spark; powders and foam separate the combustible from the oxygen in the air by smothering the reaction. The water produced by the FIRE STOP 200/30 with the Water Mist system does not act only by cooling down the combustible but also by smothering, as the millions of micro-particles saturate the environment, replacing the air and therefore the oxygen in the environment. The FIRE STOP 200/30 thus acts both by cooling and by smothering the fire. In addition, the cooling capacity of the micro-pulverized water with Water Mist technology is increased hundreds of times, as: - One drop of the volume of 1 litre of water, at the pressure of 1 bar, has a contact surface with the fire of 0.048 m 2 ; - 1 litre of misted water, at a pressure of 200 bar, generates 160 million micro-particles, which generate a contact surface with the fire of 20 m 2, i.e. 416 times more than that generated with 1 bar. One of the most important aspects of Water Mist technology is the reduction to a minimum of the water used to extinguish a fire. With the traditional extinguishing systems (hydrants, hoses etc.), a large amount of water has to be used, which often flows towards the lower floors, creating great damage and contamination of large surface areas and volumes. The FIRE STOP 200/30 with Water Mist technology limits to a minimum the water necessary for extinguishing a fire. 1 LITRE OF WATER AT THE PRESSURE OF: 1 BAR 200 BAR 0,048 m 2 20 m 2 HAS A CONTACT SURFACE WITH THE HOT GASES OF: 4

USING FOAM AND OTHER EXTINGUISHING OR RETARDANT AGENTS The FIRE STOP 200/30 can also use foam or other extinguishing or retardant agents which increase its extinguishing capacity even more. The quantity of extinguishing product can be adjusted on both systems of aspiration, at high and low pressure. An aspiration device is placed on the water line at the entrance of the high pressure pump and a second aspiration device is situated on the high pressure line, after the pump. Less than 1 minute to extinguish a car on fire. THE REAL FIRE THE ACTION OF THE FIRE STOP 200/30 IN THE FIRST PHASES The temperature of a real fire in a confined place increases in time, during which 4 very specific phases can be identified. 1) IGNITION PHASE 2) PROPAGATION PHASE 3) GENERALIZED FIRE PHASE 4) EXTINGUISHING AND COOLING PHASE There may be a variable time from between 5 to 30 minutes, for the most distant places, from the emergency call to the arrival on site of the fire-fighters. This first phase, from the onset of a fire to the arrival of the fire fighting teams, may be the most important to save a person s life or a whole business. The action of the company s team in the first phases may prevent the fire from spreading and causing major damage to people or the destruction of important facilities. Temperature CRITICAL POINT IGNITION PROPAGATION GENERALIZED FIRE EXTINGUISHING AND COOLING Time 5

FIRE STOP 200/30 TECHNICAL INFORMATION ITS MAIN ELEMENTS 8 1 4 6 9 11 5 3 2 7 10 COMPONENT DESCRIPTION 1 CHASSIS 2 THERMOSTATIC VALVE Painted steel - Dimensions: 1020x550x610 mm The chassis has 4 handles for lifting and transport. This protects the packings of the pump from any overheating of the water in recirculation, caused by prolonged operation of the unit with the nozzle shut. 3 SUPPLY WATER FILTER This allows filtering the water entering the high pressure pump. It is made of stainless steel. 4 SYSTEMS OF ASPIRATION OF SELF-EXTINGUISHING PRODUCTS Two devices, one for aspiration by the pump and the other for delivery from the pump, which allow using a wide range of extinguishing/foaming products with different mixing percentages with water. 5 HOSE REEL Manual, capacity of 40 m of high pressure hose. 6 HIGH PRESSURE FIRE FIGHTING LANCE 7 FUEL TANK 8 WATER TANK With a pistol, it allows dispensing different shapes of water jets, or water mixed with foaming and extinguishing products, and Water Mist nebulized water (p.7) Made of stainless steel, it has a capacity of about 6 litres, allowing a continuous operating autonomy of the unit of about 2 hours. Complete with: a) visual control of the level - b) connection for filling with water c) opening to clean tank - d) discharge cap 9 SUPPORT FOR PRODUCT CONTAI- NER HOLDER Allows housing the container of the extinguishing products. 10 TRUCK WITH WHEELS It has two large wheels (diameter 300 mm) which can be quickly removed. 11 CONTAINER FOR CHEMICAL PRODUCTS For extinguishing or retardant products. 6

TECHNICAL FEATURES ENGINE TYPE ENGINE POWER ELECTRICAL STARTER HIGH PRESSURE PUMP FEATURES OF HIGH PRESSURE PUMP CAPACITY OF WATER AND EXTINGUISHING/FOAMING PRODUCT TANK MAXIMUM RANGE OF WATER RANGE OF WATER + EXTINGUISHING/FOAMING PRODUCT MAXIMUM FLOW RATE EXTINGUISHING/FOAMING PRODUCT DIMENSIONS AND WEIGHT WITHOUT TRUCK AND WITHOUT TANKS DIMENSIONS AND WEIGHT WITH TRUCK AND TANKS (EMPTY) LENGTH OF STANDARD HOSE Petrol, two-cylinder 14.7 kw 12 V 3 ceramic and titanium pistons 200 bars 30 l/m 120 litres of water 30 litres of foam 16-17 m (direct jet) 8 m (diffused jet) 16-17 m (direct jet) 3 l/m 900x500x600 mm 136 Kg 1320 x 700 x 1200 mm 175 Kg 40 m The maintenance of the FIRE STOP 200/300 system is simple and immediate and can also be done by unskilled personnel. It also uses components which are easy to find internationally. FUNCTIONS OF THE LANCE WATER MIST TECHNOLOGY Nebulizing only water, or water + foam with micro-particles of water to saturate the environment and cool down the combustible. Water + foam with semi-open jet at low pressure Only water, or water + foam at high pressure Water + foam to rapidly cover the area concerned 7

LIGHTWEIGHT UNIT OF RAPID ATTACK This is a unit which has a FIRE STOP 200/30 installed (fixed or semi-fixed) on the vehicle, with a capacity of 25 30 l/m, with a water tank and hose reel. Its aim is to perform first attack fire-fighting in the fire control operations carried out by fire-fighters/company s fire protection operators. A lightweight vehicle equipped with the FIRE STOP 200/30 system. It is a complete system which can be operated by only one person and can extinguish fires or block them until the arrival of larger units. THE PECULIARITIES OF THIS SYSTEM - Versatility and speed of movement. - Access to difficult areas (narrow streets, heavy traffic, commercial areas such as squares and pavements, natural areas, etc.). - Low water consumption. - Capacity to apply foams and retardant products. - Less damage caused by water. - Easy to use: requires only one operator. - Its capacities can be increased with optional accessories, such as larger water tanks, depending on the requirements. - Modular base: if the vehicle does not work, the system can be moved on to another one in order not to lose its working capacity. CRISTANINI 37010 RIVOLI VERONESE - VERONA - ITALY Tel. +39-045-6269400 - Fax +39-045-6269411 cristanini@cristanini.it - www.cristanini.com