SECTION LIGHTING

Similar documents
SECTION EXTERIOR LIGHTING

A. Furnish and install luminaires, lamps, ballasts and in-line fuses as herein specified and shown on the Drawings.

SECTION INTERIOR AND EXTERIOR LIGHTING FIXTURES

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL

SECTION INTERIOR LIGHTING

SECTION INTERIOR LIGHTING

WINDSOR FOREST HIGH SCHOOL HVAC REPLACEMENT ADDENDUM #2 SAVANNAH CHATHAM COUNTY PUBLIC SCHOOL SYSTEM FEBRUARY 18, 2016

SECTION INTERIOR LIGHTING

SECTION INTERIOR LIGHTING

Applications. Standard Materials

SECTION LIGHTING CONTROL DEVICES AND CONTROL PANELS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018

SECTION LOW VOLTAGE LIGHTING CONTROLS

LED RETROFIT SOLUTIONS

1. Division 26 Section Electrical General Requirements. 2. Division 26 Section "Wiring Devices" for wall-box dimmers and manual light switches.

B. It is recognized that these standards are updated irregularly and lighting technology is changing rapidly.

E. Luminaire: Complete lighting fixture, including ballast housing if provided.

MN/DOT Specification Sign Lighting Luminaire With 150 or 250 Watt Metal Halide Lamps 11/05/09

Catalog Number. Notes. Type. FST Snap on frosted, diffuse L/LENS No diffuser

LED RETROFIT CONVERSION KITS

SECTION ENCLOSED CONTROLLERS

Catalog Number. Notes

A. This Section includes the following lighting control devices:

2. Lighting fixtures mounted on exterior building surfaces.

SECTION CENTRAL BATTERY INVERTERS. A. This Section includes fast-transfer central battery inverters with the following features:

IBLED SERIES 4' PROJECT: FEATURES AND SPECIFICATIONS LINE DRAWING

PowerWave 2 Busway System

Dimensions (111mm) 3 (76mm) (111mm) (48mm)

A. This Section includes the following lighting control devices:

WARRANTY LED ECO PANEL.

SECTION LIGHTING CONTROLS

Dimensions (111mm) (111mm) 3 (76mm)

Emery County Senior Center Green River 06/07

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

IVR15-RPS O.D. Solid State Illuminated Rail Remote Power Supply

East Central College

LED RETROFIT CONVERSION KITS

TROFFER RETROFIT KIT (TRK)

80W C1D2 Hazardous Location Integrated LED - Corrosion Resistant for Marine - Emergency Backup

SDL4 LED Strip Diffused Lens

BAS SDL8' LED Strip Diffused Lens

SECTION LIGHTING CONTROL DEVICES

DHL-LP-LED Low Profile LED Linear High/Low Bay

VESICA LINEAR SUSPENDED VES L

CL001 >400 Watt lamp basecase, up to 600 Watt replacement fixture $95.00 Fixture

Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening.

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

FPLHB - Fidelux Premier Linear Highbay

SECTION AIR DOORS

100W Explosion Proof Ultraviolet Portable LED Fixture - 365NM - EXP Cord Caps - 150ft Cord

SECTION (15767) - UNIT HEATERS

SECTION FAN COIL UNITS

Pacific Gas and Electric Company Energy Efficiency Rebates for Your Business. Lighting Rebate Catalog Saving energy for a brighter future

LMV Series W Low Profile - Medium Base

Pro Series LED Lighting Champ LED floodlights. Champ Pro Series. LED floodlights for heavy industrial

Lighting Solutions. from a Leader in Light Source Technology

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

SECTION PANELBOARDS. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.

Emergency Lighting. Product Guide LED. The right source for the. right light

SETION EMERGENCY LIGHTING NATIONAL FIRE PROTECTION ASSOCIATION (NEPA) (2006) Life Safety Code, 2006 Edition

SECTION (16140) - WIRING DEVICES

M001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings

LUCE 1 TL. specifications: internal. specifications: external. ordering logic. builder. Job/Location:

150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam

ROAM DCM Control Specification Guideline Division 16520

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY

LED ECO PANEL.

MAR2 LED SERIES M A R 2 L E D. Linear LED Lighting for Hazardous Locations

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR

Taxonomies, Classifications, and Categories Residential dimmers, motion sensors, controls, & photo cells Rotary dimmer, single-pole

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style V Dimmable

Construction Standards Page

SECTION LIGHTING CONTROL DEVICES EATON S LIGHTING SYSTEMS (FORMERLY COOPER CONTROLS) VACANCY/OCCUPANCY SENSORS

LED retrofits! 4 T8 Specification Guide. Retrofit your existing Fluorescent Lights in Seconds No Electrician Needed! Pure Bright

VIENTO MEDIUM AREA & SITE LED LUMINAIRE OPTICS

Solid State Lighting Sub-Assembly Interfaces for Luminaires. Andrew D. Jackson Philips Lighting Corporate Regulatory and Certification Laboratory

Custom Duct Heaters. Special Applications

Explosion Proof 70 Watt Low Profile LED Light Fixture Lumens - C1D1 Group B - Hydrogen Rated

CHINESE NEW YEAR DEADLINE SOLUTIONS

Product Specifications MaxLumen MRI LED Diffused Lighting

THE HIGH STRIP FIXTURE SERIES PERFORMANCE KEY FEATURES INCLUDE: LED Fixture Series for General, Direct and Indirect Illumination

BAS SFP22 Edge-lit LED Panel

Step Lighting. For indoor and outdoor, stair and pathway applications. Juno Lighting Group Juno Step Lighting 1

LED Linear Design Highlights

Student Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

B. Section Identification for Fire Suppression Piping and Equipment.

FIRE ALARM: BY OTHERS, IF REQUIRED.

ARCHITECTURAL SPECIFICATIONS

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Lighting. Basis of Design

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

STYLISH SOLUTIONS FOR OUTDOOR AND INDOOR SPACES

PRODUCT DATA SHEET LIGHTING PRODUCTS

SECTION GAS-FIRED RADIANT HEATERS

A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings.

IN2 Lighting Control Devices

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Transcription:

SECTION 26 50 00 LIGHTING PART 1 GENERAL 1.1 DESCRIPTION A. Scope: 1. CONTRACTOR shall provide all labor, materials, equipment, and incidentals as shown, specified, and required to furnish and install lighting fixtures and associated controls. B. Coordination: 1. Coordinate location of fixtures with piping, ductwork, openings, and other systems and equipment and locate clear of interferences. 2. Coordinate fixtures to be mounted in hung ceilings with the ceiling suspension system proposed. C. Related Sections: 1. Section 01 74 05, Cleaning 2. Section 26 05 05, General Provisions for Electrical Systems. 3. Section 26 05 53, Identification for Electrical Systems. 1.2 REFERENCES A. Standards referenced in this Section are: 1. UL 844, Luminaires for Use in Hazardous (Classified) Locations. 2. UL 935, Safety of Fluorescent Lamp Ballasts. 3. UL 1029, Safety of High-Intensity- Discharge Lamp Ballasts. 4. UL 1598, Safety of Luminaires. 1.3 QUALITY ASSURANCE A. Regulatory Requirements: Comply with the following: 1. NEC Article 410, Luminaires, Lampholders, and Lamps. 1.4 SUBMITTALS A. Action Submittals: Submit the following: 1. Shop Drawings: a. Schedule of light fixtures to be furnished, indicating fixture type and location for each. b. Customized wiring diagrams. 2. Product Data: a. Manufacturer s technical information, specifications, standard wiring diagrams, and catalog cuts for lighting fixtures proposed. GA064015.0004 26 50 00-1 Lighting

b. Fixture construction details. c. ETL photometric and isocandle curves for each fixture proposed. d. Verification that recessed fixtures to be mounted in hung ceilings are compatible with ceiling suspension system proposed. B. Informational Submittals: Submit the following: 1. Manufacturer s Instructions: a. Instructions and recommendations for handling, storing, and protecting the equipment. b. Installation instructions for for the equipment, including setting drawings, templates, and directions and tolerances for installing anchorage devices. C. Maintenance Material Submittals: Submit the following: 1. Spare Parts and Extra Stock Materials: Furnish spare parts for each type of unit required as indicated in Part 2 of this Section. 1.5 PRODUCT DELIVERY, STORAGE AND HANDLING A. Delivery: 1. Upon delivery, inspect equipment for evidence of water that may have entered equipment during transit. B. Storage: 1. Store lighting fixtures, controls, related materials and equipment in clean, dry location with controls for uniform temperature and humidity. Protect materials and equipment with coverings and maintain environmental controls. 2. Store materials and equipment for easy access for inspection and identification. Keep materials and equipment off ground, using pallets, platforms, or other supports. Protect materials and equipment from corrosion and deterioration. PART 2 PRODUCTS 2.1 MATERIALS A. Type: Lighting fixtures required shall be in accordance with the Lighting Fixture Schedule on the Drawings. Fixtures shall be complete with supports, ballasts, lamps, and incidentals, as required. 1. LED fixtures shall be modular and allow for separate replacement of LED lamps and drivers. User serviceable LED lamps and drivers shall be replaceable from the room side. 2. Dimmable LED fixtures shall have either a 0-10 volt, 3-wire dimming driver, or a two-step (50%-100%) line voltage, two switch controlled dimming driver, as shown on the drawings. B. Fixtures in hazardous locations shall be listed in accordance with UL 1598 and UL 844. GA064015.0004 26 50 00-2 Lighting

C. Lamps: 1. Fluorescent: Fluorescent lamps shall be toxic characteristic leaching procedure (TCLP) compliant for low mercury content. Linear fluorescent lamps shall be T8, energy-efficient, extended life type. Compact fluorescent lamps shall be long-life, energy-efficient type. 2. High Pressure Sodium: Shall be TCLP-compliant for low mercury content. Lamps shall be clear with high-efficacy and lumen maintenance. 3. Metal Halide: Shall be fabricated for low mercury content and be TCLPcompliant when available. Lamps shall be clear-pulse, start type with highefficacy and lumen maintenance. 4. Incandescent: Inside-frosted. 5. LED lamps shall have a color temperature of 3500 degrees K, a CRI of 80 minimum, and a lumen maintenance L70 rating of 50,000 hours minimum. 6. Spare Parts and Extra Stock Materials: Ten percent spare lamps of each type and wattage. D. Ballasts: 1. Fluorescent: UL 935 listed, high power factor, energy-efficient type, equipped with thermal protectors (Type P ballast), compatible with lamps installed. Indoor two-lamp fluorescent ballasts shall be electronic type with total harmonic distortion of less than 20 percent. Ballast factor shall be 0.85 minimum with total of less than 61 watts input. Provide cold weather type ballast where indicated in the Lighting Fixture Schedule. 2. High Intensity Discharge: UL 1029 listed, high power factor, constant wattage, stabilized autotransformer with line starting current the same or less than operating current. 3. Ballasts sound level shall be 30 decibels or less, sound rating A. 4. Ballasts shall be Edison Testing Laboratories (ETL) listed and Certified Ballast Manufacturer Association, CMB-certified. 5. For fixtures utilizing double-ended lamps, provide fixture disconnecting means within the fixture. 6. LED drivers shall be electronic-type, labeled as compliant with radio frequency interference (RFI) requirements of FCC Title 47 Part 15, and comply with NEMA SSL 1 Electronic Drivers for LED Devices, Arrays, or Systems. LED drivers shall have a sound rating of A, have a minimum efficiency of 85%, and be rated for a THD of less than 20 percent at all input voltages. 7. Dimmable LED drivers shall be 0-10V type. Dimmable LED drivers shall be capable of dimming without LED strobing or flicker across their full dimming range. 8. Spare Parts and Extra Stock Materials: Ten percent spare ballasts of each type and quantity, but not less than one. E. Fixtures located in area identified as hazardous in Section 26 05 05, General Provisions for Electrical Systems, shall each be approved as a complete assembly, shall be clearly marked to indicate maximum wattage of lamps for which they are approved, and be protected against physical damage by suitable guards. GA064015.0004 26 50 00-3 Lighting

F. Hardware: Provide necessary hangers, supports, conduit adaptors, reducers, hooks, brackets, and other hardware required for safe fixture mounting. Hardware shall have protective, non-corrosive finish. G. Outdoor Fixtures: Provide each fixture to be installed outdoors with cut-off lens to reduce the fixture s light pollution emissions. H. Time Switch: 1. Type: Astronomic digital time switch with photocell input. 2. Products and Manufacturers: Provide of one of the following: a. DGLC100A-NC by Tork Time Controls, Inc. 3. Capacity: 20 amps per pole at 120-277 volts. 4. Reserve Power: Power outage backup with permanent schedule retention via capacitor. 7 days of real time backup. I. Lighting Contactor and Controls: 1. Provide a lighting contactor and control system for control of each area where shown on the Drawings. 2. Product and Manufacturer: Provide products of one of the following: a. Type SM03 by Square D Company. 3. System shall include: a. Enclosure sized as required, complete with input control fuse and screw type terminal blocks rated 300-volt, 20-amp quantity for all circuits, unless indicated otherwise on the Drawings. b. Single coil, electrically-operated, mechanically-held contactor. Contactor shall be rated 30-amp, 600-volt, with 120-volt operating coil, unless indicated otherwise on the Drawings. Number of poles shall be as shown on the Drawings. Provide multiple contactors when necessary. c. Where lighting contactors are controlled by photocell, provide a 120-volt, two-pole control relay, enclosure mounted to convert the two-wire photocell control to three-wire control required by contactor. Control shall include a cover mounted on-off-auto selector switch for manual or auto selection of operation. In auto position, contactor shall respond to photocell. d. Enclosure: As required for area classification per Section 26 05 05, General Provisions for Electrical Systems. e. Identify panel in compliance with Section 26 0 53, Identification for Electrical Systems. J. Photocell: 1. Products and Manufacturers: Provide one of the following: a. 2100 Series by Tork Time Controls, Inc. 2. Cadmium sulfide hermetically-sealed cell, fully temperature compensated, with time delay of not less than 15 seconds to prevent false switching. GA064015.0004 26 50 00-4 Lighting

3. Built-in fail safe light level selector, adjustable within limits of two to 50 footcandles and factory set at 25 foot-candles. K. Fixture-Lowering Hanger System: 1. General: a. Provide corrosion-resistant system that lowers fixtures to ground level to allow maintenance on fixtures. Provide lowering hanger system for each fixture as shown on the Drawings. 2. Products and Manufacturers: Provide one of the following: a. Thompson Hangers, by Joslyn Hi-Voltage Corp. 3. System: a. Upper or fixed housing of lowering devices shall contain: 1) Attached pulley. 2) Single point latching mechanism. 3) Guide. 4) Upper or socket electrical contacts. b. Lower or moveable housing of lowering devices shall contain: 1) Operating line termination. 2) Positioning stem and lower half of latch assembly. 3) Lower electrical contacts. 4) Fixture adapter. c. Fixtures shall be lowered on a guide line to allow operation of system in adverse weather and with structural clearance. Angles of the guide line to the structure shall be in accordance with to lowering device manufacturer s instructions. d. Operating line shall be high-strength/high-flexibility stainless steel and supplied by the lowering device manufacturer. e. Each operating line shall be encased in conduit where lower than eight feet above finished floor. f. Non-hanger termination shall be of enclosed and surface mounted design. g. Pulleys shall be supplied by hanger manufacturer as required to prevent excessive cable sag and allow lateral offsets between fixture location and cable termination. h. Provide portable manual winch. 4. Electrical: a. Contact material shall be silver-impregnated/silver-plated plate copper. Contacts shall use ball and socket design for ease of alignment and to allow for residual building vibration and movement. b. Contact pressure shall be supplied by springs remote from current conductors and shall not be part of current-carrying path. c. Termination of wiring shall be to crimp connectors. d. Provide electrical insulation of contacts by porcelain standoffs. e. Lowering device shall be make-and-break rated, UL-approved, as follows: 1) 250 VAC: 30 amps 2) 600 VAC: 15 amps 3) 250 VDC: 10 amps GA064015.0004 26 50 00-5 Lighting

f. Lowering device shall have eight contacts rated at 120 VAC, 15 amps. 5. Mechanical: a. System loading capacity: 200 pounds. b. Manual or power winch operation. c. Housing manufactured with copper-free or low copper content cast aluminum. d. Operation shall be slow pull/quick release method. e. Maintenance-free design. f. Latching means shall be single point centered design to facilitate even wear over life of hangar. g. Provide a tag line to facilitate lateral movement over inaccessible spaces. Tag line shall consist of the following parts by hanger manufacturer: 1) Termination kit for wall. 2) Manual winch. 3) Operating cable. 4) Pulley for upper mounting. L. Motion/Occupancy Sensor: 1. General requirements a. Dual technology, PIR/ultrasonic b. 120/277 VAC compatible c. White finish 2. Ceiling mount type sensor - provide one of the following: a. Leviton OSC20-MAW 3. Wall mount switch type sensor provide one of the following: a. Leviton OSSMT-GAW PART 3 EXECUTION 3.1 INSPECTION A. Examine conditions under which the Work will be installed and notify ENGINEER in writing of conditions detrimental to proper and timely completion of the Work. Do not proceed with the Work until unsatisfactory conditions are corrected. 3.2 INSTALLATION A. General: 1. Fixture mounting heights and locations indicated on the Drawings are approximate and are subject to revision in the field where necessary to clear conflicts and obstructions. 2. Mounting Heights: Mounting heights or elevations are to bottom of fixture or to centerline of device. 3. Install fixtures in accordance with Laws and Regulations, the Contract Documents, and manufacturer instructions and recommendations. GA064015.0004 26 50 00-6 Lighting

4. Mount fixtures so that sufficient access is available for ready and safe maintenance. 5. Securely fasten equipment to walls or other surfaces on which equipment is mounted. B. Suspended Fixtures: 1. Pendant-mount using 1/2-inch diameter conduit stems. 2. Ground to outlet box. 3. Attach mounting to building structure with expansion anchors. 4. Fixtures shall not be dependent on the outlet box cover screws for support. C. Surface Mounted Fixtures: 1. Attach to appropriate outlet box. 2. Attach to surface using fasteners and sealing washers when mounting fixture in damp or wet locations. D. Boxes and Fixtures: 1. For units mounted against masonry or concrete walls, provide suitable 1/4-inch spacers to prevent mounting back of box directly against wall. 2. Bolt units rigidly to building with expansion anchors, toggle bolts, hangers, or Unistrut. 3. Do not install boxes with open conduit holes. 4. Cable each circuit and identify with tag. E. Re-lamp all fluorescent fixtures provided under this Contract with new lamps following Substantial Completion. F. Mount photocells as shown and adjust foot-candle setting for proper dusk and dawn photo-control. Provide wiring in conduit from photocell to controls. G. Fixture Lowering System: 1. Hangers shall be plumb. 2. Provide adequate clearance between operating line and structural members, pipes, ducts, and other equipment and devices to avoid interference. 3. Conduit runs enclosing operating lines shall be straight with no offset bends. + + END OF SECTION + + GA064015.0004 26 50 00-7 Lighting