Process & TeMPerATUre UniversAl input DigiTAl MeTers

Similar documents
PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Temperature Controllers

Nov 08 PRODUCT SPECIFICATION SHEET

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

I/A Series 716C 1/16 DIN Temperature Controller

Series Temperature Controller Instruction Sheet

NOVUS AUTOMATION 1/5. Range: -35 to 720 C (-31 to 1328 F) Range: -90 to 1300 C (-130 to 2372 F) Range: 0 to 1760 C (-32 to 3200 F)

General Specifications

SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting

DIGITAL METERS Large Display Temperature Meters Instruction Manual

F4 Process Controller Installation and Operation Guide

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

Series Digital Controller Instruction Sheet

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

02/11/2015

Digital Meters 2002 SINCE 1974 CATALOG. Level Flow Temperature Pressure. PRECISION DIGITAL CORPORATION

INSTRUCTION MANUAL Micro-computer based digital indicating controller

02/11/2015

COMMANDER 150. User Guide Universal Process Indicator A1

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

Instruction manual Temperature Controller KT7

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

Instruction manual for DIN rail mounting type indicating controller DCL-33A

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

SHIMADEN DIGITAL INDICATORS

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

/8 DIN Universal Process Indicator

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

Warning Caution INSTRUCTION MANUAL DIN RAIL MOUNTING TYPE INDICATING CONTROLLER

User's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT

UDC1000 & UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

Two-Channel Gas Controller

DIGITAL INDICATOR JIR-301-M

UDC100 Universal Digital Controller Specifications

7EF/7HF/7EC/7ES Temperature Controllers

Table of Contents SECTION PAGE

SA100L. General Description. Features. Temperature Limit Controller SA100L. Simple Mounting on DIN Rail. Over/Under Temperature Protection

Installation Manual Tracker 221

Instruction manual Micro-computer based digital indicating controller

UDC 700 Universal Digital Controllers and Indicator Specifications

N1540 Process Indicator

DCL-33A No.DCL31E To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual.

Carbon Monoxide Transmitter

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

RS485 MODBUS Module 8AI

MDS8PT. Universal Temperature & Process Benchtop Meter with Alarms

Specification , July 2015

INSTRUCTION MANUAL FOR MICROCOMPUTER BASED TEMPERATURE INDICATING CONTROLLER FCS-23A

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

GCS-300 No.GCS31E

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Non-contact voltage (for SSR drive): V DC DC current: 4 to 20mA DC Thermocouple: K, J, E Input. RTD: Pt100, JPt100

/8 DIN Level Indicator

Oxygen (O2) Single-Point Gas Detection System

CTT8 TEMPERATURE MONITOR DEVICE

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

PSE-369A. KL4000 SERIES 100mm chart DOT-PRINTING TYPE HYBRID RECORDER

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

User Guide. DATUM L150 Panel-Mounted Universal Level Indicator A1. ABB Instrumentation

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

User s Guide CN616A. Universal 6 Channel ¼ DIN Process Controller. Shop online at omega.com

User Guide IM/C160_8. Wall-/Pipe-mounted Universal Process Indicator C160

MO n : 12JMC rév A

Process Alarm Module RTA 421

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

User Guide IM/L160_6. Wall-/Pipe-mount Level Indicator L160

+ A B V B NO NC V COM PV PV

Model 96VTR ¼ DIN Process Controller

HTC-915-CONT. Heat-Trace Control system

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

Alarm Modules Section E

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

Micro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e

Instruction Bulletin

Tri-Stack Smart System

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

TAIE. Features. FY600 (96mm X 48mm) Application:Control temperature,humidity, FY Series Digital PID Controller

CLEANROOM MONITOR CR3A Network - Installation Instructions

COMMANDER 160 Wall/Pipe-mounted Universal Process Indicator. User Guide. ABB Automation

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

AutomationDirect. PC35 Configuration Sheet

99 Washington Street Melrose, MA Phone Toll Free Visit us at

Oakton TEMP 9500 Advanced Multiparameter Controller

Table of Contents. T538 Instruction Manual Rev # 6 June R6T538 June rtf E L Switchgear and Control Inc

Universal controller for panel mounting Models CS6S, CS6H, CS6L

Product Manual SZ1145

Model D12-IR. Digital Gas Transmitter...

Transcription:

Process & TeMPerATUre UniversAl input DigiTAl MeTers nova PD56 series Thermocouple, rtd, & Process inputs Universal Power supply 1-24 va c Up to 3 Alarm relays retransmitting 4-2 ma output input Max/Min Display reset with Digital inputs rs-485 serial communications option Modbus rtu/a scii communications Free Monitoring & Data logging software ip55 & ip65 Fronts 1/8 & 1/4 Din sizes 3 Year Warranty Precision Digital corporation www.predig.com

NOVA PD56 Series process & temperature Meters Custom Operating Displays The Nova Digital Meters have dual four-digit LEDs and can display commonly accessed parameters such as the maximum and minimum input values. Operating Display Navigation To access additional display information without the need to enter the setup menus, simply press the SET/ENT button. Example: US1 Set to Display PV Max Example: US2 Set to Display PV Min Main Operating Display PV window displays process variable Press the SET/ENT button to move to the next display window User Defined Display 1 Display any setup parameter Parameters are fully functional, and can be set through this display Set by the user with parameter US1 Press the SET/ENT button to move to the next display window User Defined Display 2 Display any setup parameter Parameters are fully functional, and can be set through this display Set by the user with parameter US2 Press the SET/ENT button to return to the main operating display Easy Setup & Programming All programming of a Nova Digital Meter is done through the front panel. No switches or jumpers are required. Front Panel Buttons Press the SET/ENT button to confirm an entered value. Hold the button for 3 seconds to enter or exit the setup groups. Press the SET/ENT button to access the next parameter when in a setup group. Press the Up button to increase numerical values or scroll through parameter options and group menus. Press the Down button to decrease numerical values or scroll through parameter options and group menus. Press the LEFT button to move to the next digit during numerical value programming. Setup Group Menus For easy parameter navigation, all parameters are grouped by category. To access the group menus, press and hold the SET/ ENT button for 3 seconds. Navigate through the group menus using the UP and DOWN arrow buttons as shown. To enter a group menu to edit or view parameters, press the SET/ENT button. Button PV Display Group Definition ENT PwD Password pq G.CTL Control Group pq G.IN Input Group pq G.ALm Alarm Group pq G.RET Retransmission Group pq G.Com* Communications Group* *This group menu appears only on models with the serial communication option. Menu Password To prevent unauthorized changes to key parameters, a user defined lockout password must be entered to access the group menus that are not commonly used during operation. Enter the password at the prompt when navigating the group menus by pressing the SET/ENT button. The default password is. Easy to Use Menu Structure Each parameter is located in an associated menu group. P u D ~ G.Ctl Hold the SET/ENT button for 3 seconds to enter the menus Select the menu group using the p and q buttons Press SET/ENT to access the parameters in the group Set the value for the parameter, and use the SET/ENT button to select the next parameter Hold the SET/ENT button for 3 seconds to return to the operating display G.In In-t In-U BS4 For a complete list of setup parameters, their functions, and setting options, refer to the PD56 Series Instruction Manual. G.Con ~ Process & Temperature Inputs Nova Digital Meters use a single universal input that accepts process and temperature inputs. Thermocouple: J, K, T, E, R, B, S, L, N, U, W, Platinel II RTD: Pt1 (.385), JPt1 (.392) Process: -1 to 2 mv, to 1 mv.4 to 2 V, 1 to 5 V, to 1 V 4 to 2 ma input with a resistor shunt 2

nova PD56 series Process & TeMPerATUre MeTers general FeATUres The PD56 Series of meters combines excellent standard features including a universal input, alarm relay, and a 4 to 2 ma retransmitting output with powerful options including an additional two alarm relays, digital inputs, and RS-485 serial communication including Modbus. Alarm relays All PD56 Series Digital Meters have a standard 3 A Form C (SPDT) alarm relay. Up to two additional 1 A Form A (SPST) relays may be added. All relays can be programmed for a variety of alarm types. High/Low Alarms Set Point Deviation Alarms Fail-Safe and Standby Alarms Relay Delays and Reset Deadbands 4-2 ma retransmitting output A 4-2 ma powered output is standard on all PD56 Series models. The output can be programmed to transmit over any input scale for any input type. Transmitter loop Power supply The 4-2 ma retransmitting output may be configured to provide a 14 to 18 VDC @ 2 ma transmitter power supply. input Bias Adjustment Up to five bias points can be used to provide precise offset adjustments at specific input values. The controller will use the offset to create a smooth input value curve leading up to the bias points. Display Max/Min input values PD56 Digital Meters can record and display maximum and minimum input values. These values will be stored until reset by the user power to the meter is lost. Through the use of the user defined displays, these values can be accessible with the push of the SET/ENT button. serial communications & Adapters Nova meters with the serial communications option can be used for data acquisition or with Modbus communication (RTU and ASCII). Nova meters transmit via RS-485. PDA7485 RS-232 to RS-485 isolated and non-isolated converters and PDA8485 USB to RS-485 isolated and non-isolated converters are available for use with the Nova Multi-Monitoring software or other PC applications. nova Pc software Any Nova Controller with the serial communications option can be configured to interface with the Nova Multi-Monitoring PC software. Up to 3 meters can be monitored and operated, and each can use independent data logging. Easy to Set Up and Use Connect up to 3 Nova meters View PV and Alarm Status Log, View, and Save Data in Spreadsheet Files Free Download from www.predig.com specifications System Requirements: Windows 95\98\ME\2\XP Communications: An RS-232 to RS-485 or USB to RS-485 converter may be used for communication with a PC and Nova Multi-Monitoring Software. Number of Units: Up to 3 Nova Controllers Baud Rate: 9,6 to 19,2 bps Data Logging: Graph and save data as.hdr format. Each controller saves graphs independently. Data exportable in spreadsheet format. Logging Interval: 1 second to 24 hours simultaneous Monitoring Simultaneously monitor up to 3 Nova Meters and view the PV and alarm status for all connected controllers. The main view screen also displays the basic model numbers of all connected units. Any series of Nova Controllers with the serial communications option may be monitored with this software. Digital input Max/Min reset Two digital inputs can be added as an optional feature. Digital inputs are activated by closing contacts or low logic levels. The configuration of the two inputs can be used to hold or reset the maximum and minimum input values simultaneously or independently. NO switches (external excitation not required) or open collector transistor Simultaneously View Up to 3 Nova Controllers 3

nova PD56 series Process & TeMPerATUre MeTers real Time indication and graphing A detailed operation screen for each controller indicates the model number of the meter, PV, alarm conditions, and maximum and minimum input values. A live updating graph shows PV information as it is logged. Data Acquisition PV data can be logged independently for each meter, and each can have a distinct file name, save location, and logging interval. This data can be graphed using the Data Viewer for quick and clear analysis. Logged data can be exported into spreadsheet format. View Logged Data Graphs and Export Data DiMensions AnD PAnel cutouts PD562 1/8 DIN (H) (96 x 48) 4.72 (12) Units: inches (mm) 1.89 (48) 1.76 x 3.61 (44.6 x 91.6) 2.76 (7) PD568 1/4 DIN (96 x 96) 3.78.45 3.92 (96) (11.4) (99.6) 4.72 (12) 1.77 (45 ) 3.78 (96) 4.23 (17.5) 3.61 x 3.61 (91.6 x 91.6) 3.78.45 3.92 (96) (11.4) (99.6) 4.72 (12) 3.78xN +.2 (96xN-4 ) MoDel number guide The following guide describes the possible PD56 Series Nova Digital Process & Temperature Meter model numbers. Refer to the price list for the complete list of models and accessories. 4

NOVA PD56 Series process & temperature Meters CONNECTIONS PD562 : Options 2 19 18 17 16 15 14 13 12 11 1 9 8 7 6 5 4 3 2 1 - PD568 Rating: 25 VAC @ 1 A Rating: 25 VAC @ 3 A 3 VDC @ 3 A - Rating: 25 VAC @ 1 A MAX: 192bps 1-24 VAC 5/6 Hz Open circuit voltage: approximately 5 VDC Logic levels: LO = to.8 VDC HI = 4.7 to 28 VDC NO switches (external excitation not required) or open collector transistor 5

NOVA PD56 Series process & temperature Meters SPECIFICATIONS Except where noted all specifications apply to operation at +25 C. General Display: Dual 4 digits, red LED, -1999 to 9999 DIN Sizes PV Display Inch (mm) SP Display Inch (mm) Weight oz (g) 1/8 (H).78 (19.8).45 (11.5) 1. (285) 1/4.81 (2.5).43 (11.) 13.9 (394) Front Panel: Panel gasket provided 1/8 DIN: IP65 1/4 DIN: IP55 Programming Methods: Four front panel buttons and Modbus Noise Filter: Programmable 1 to 12 seconds, or off Display Update Rate: 4/second Max/Min Display: Stored until reset by user or meter is turned off. Password: Restricts modification of programmed settings. Non-Volatile Memory: Settings stored for a minimum of 1 years. Power: 1-24 VAC, 5/6 Hz, 1 W Required Fuse: UL Recognized, 1 A, 25 V, slow-blow Isolation: 23 V input/output-to-power line; 4 kv relay output-to-input/ output/power line. Operating Temperature: 1 to 5 C Storage Temperature: -4 to 85 C Relative Humidity: 2 to 9% non-condensing Enclosure: 1/8 & 1/4 DIN available; impact-resistant plastic; color: black Approvals: UL & C-UL Recognized, CE Compliant UL File Number: E24427; Process Control Equipment Warranty: 3 years parts & labor Extended Warranty: 1 or 2 years, refer to Price List for details. Temperature Inputs Inputs: Factory calibrated, field selectable: J, K, T, E, B, R, S, L, U, N, W, and Platinel II thermocouples and 1 Ω platinum RTD (.385 or.392 curve) Cold Junction Reference: Automatic or off Offset Adjustment: Four programmable input bias zones Sensor Break: Up or down scale, user selectable; display reads S.OPN; alarm relays will follow the up or down scale selection. Thermocouple RTD Type Range (ºC) Range (ºF) Accuracy* K1-2 to 137-3 to 25 K2-199.9 to 999.9 to 23 >ºC: ±.1% FS ±1 count J -199.9 to 999.9-3 to 23 <ºC: ±.2% FS ±1 count T -199.9 to 4. -3 to 75 E -199.9 to 999.9-3 to 18 B to 18 32 to 33 >4ºC: ±.15% FS ±1 count <4ºC: ±5% FS ±1 count R to 17 32 to 31 S to 17 32 to 31 ±.15% FS ±1 count L -199.9 to 9. -3 to 16 >ºC: ±.1% FS ±1 count U -199.9 to 4. -3 to 75 <ºC: ±.2% FS ±1 count N -2 to 13-3 to 24 >ºC: ±.1% FS ±1 count <ºC: ±.25% FS ±1 count W to 23 32 to 42 ±.2% FS ±1 count Platinel II to 139 32 to 25 ±.1% FS ±1 count PtA -199.9 to 85. -3 to 156 PtB -199.9 to 5. -199.9 to 999.9 ±.1% FS ±1 count PtC -19.99 to 99.99-4. to 212. ±.2% FS ±1 count JPtA -199.9 to 5. -199.9 to 999.9 JPtB -15. to 15. -199.9 to 3. ±.1% FS ±1 count *Performance within recommended operating conditions (1 to 5 ºC, 2 to 9% RH) Process Inputs Inputs: Field selectable:.4 to 2. V, 1 to 5 V, to 1 V, -1 to 2 mv, to 1 mv. 4-2 ma input requires 1 Ω resistor connected across input terminals (order P/N: PDX-RES1). Accuracy: ±.1% FS ±1 count Decimal Point: Up to 3 decimals: 9.999, 99.99, 999.9, or 9999 Calibration: All inputs are calibrated at the factory Scale Range: User programmable over entire range Transmitter Supply: 14 to 18 VDC @ 2 ma; available instead of retransmitting analog output; selection is made through the front panel. Alarm Relays Ratings: 1 Form C (SPDT) standard; rated 3 A @ 3 VDC or 3 A @ 25 VAC resistive load. 1 or 2 Form A (SPST) optional; rated 1 A @ 3 VDC or 1 A @ 25 VAC resistive load. High/Low Alarm: User may program any alarm for absolute high or low operation, forward or reverse (fail-safe) mode. Alarm Deadband: -1% FS, user selectable Alarm Delay: to 99 minutes and 59 seconds Reverse Operation (Fail-Safe): Programmable, independent for each alarm. Relay coils are energized in non-alarm condition. In case of power failure, relays will go to alarm state. Forward Operation: Relay coils are energized in alarm condition. In case of power failure, relays will go to non-alarm state. Auto Alarm Initialization: Normal and standby operation independent for each alarm. Normal alarms will reflect the state of the input to the meter at all times. Standby alarms will not trigger if the change to alarm state is a result of power up cycle, set point change, or alarm configuration change. 4-2 ma Retransmitting Output Scaling Range: 4-2 ma output can be scaled for any display Accuracy: ±.1% FS Power: Internally powered 4-2 ma output Isolation: 5 V input-to-output Output Loop Resistance: 6 Ω max Digital Inputs Configuration: Two contacts. Two operating modes. Contacts: Normally open switches (external excitation note required) or open collector transistor Open Circuit Voltage: Approximately 5 VDC Logic Levels: LO = to.8 VDC, HI = 4.7 to 28 VDC Operation Modes: Mode 1: Store and reset max & min display values simultaneously. Mode 2: Store and reset max & min display values independently. Serial Communications Compatibility: EIA-485 Protocols: PC, Modbus (ASCII, RTU) Address: 1 to 99 (Max 31 units connected) Baud Rate: 6 to 19,2 bps Transmit Time Delay: to 1 ms Data: 7 or 8 bit, automatic when using Modbus protocol Stop Bit: 1 or 2 Parity: None, even, or odd LDS56_C 7/9 Precision Digital Corporation 89 October Hill Rd Holliston MA 1746 USA Tel (8) 343-11 Fax (58) 655-899 www.predig.com