Ml ['l>l'ol]

Similar documents
BST-MG08/09 Multi-gas Detecting Alarm. Manual Instruction

BST-MG07 Multi-gas Detecting Alarm Manual Instruction

B -MG0 i gle G Detecti A rm Ma a nstructio. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

BST-MG01 Single Gas Detecting Alarm Manual Instruction

IMR IX176 Portable Gas Detector User Manual

GasAlertMicroClip X3 Specifications

ALTAIR 5X Multigas Detector Product Specification

IMR EX610. Portable Gas Detector. Operation Manual

E1000 Portable gas detector

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

NATURAL GAS DETECTOR. Confined Space Monitor. Leak Investigation. Line Purge Testing. Bar Hole Sampling

MODEL: SP2nd (Portable Single Gas Detector) Operating Manual

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

DI220 Using the Optional Docking Station The maintenance and operating functions of the Micro IV can be automated with the Micro IV Docking Station.

EL-USB-1-LCD Temperature Data Logger with LCD

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

Dräger X-am 7000 Multi-Gas Detection

For the Safety of Your

RAE Systems Systems. User Presentation. October Protection Through Detection

Using the QRAE Plus personal multigas monitor

ALTAIR 5X Multigas Detector

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Micro IV. Single Gas Detector. Operations Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

Model:AS8900 MULTI-GAS MONITOR O 2 %VOL H 2S PPM LEL%VOL CO PPM. Version number:as

Safe Operation Manual. Honeywell IQ Force Gas Detector

T.ex Single Gas Detector VISA

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

MULTI-GAS MONITOR. Eastern Energy Co., Ltd. 40/4 Vitoondumri Rd., Banbueng Banbueng, Chonburi, Thailand

Technical Reference Guide. 1, 2, 3, and 4-Gas Detector

PROTÉGÉ ZM SINGLE GAS MONITOR

Operate the Mutli-Gas Monitor PID

Monitores Personales. Personal Monitor

G450. Multi-gas Detector. Operations Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

The GasWatch 2 will operate for over 3,000 hours on one battery (about 1 year normal use). And yes, the GasWatch 2 even tells the time!

portable gas analyser

Clip SGD. Portable single Gas Detector. User manual

Bacharach Bodyguard 4 User's Guide

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

User s Guide HHAQ-109. Portable Multi-gas Detector. Shop online at omega.com SM

Portable type of Carbon Dioxide Detector Model: GT220

Two-Channel Gas Controller

PERSONAL COMBUSTIBLE GAS DETECTOR

Sirius Technologies, Inc.

G460. Multi-gas Detector. Operations Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

portable gas analyser

CO2 RESPONDER Portable Carbon Dioxide Detector QUICK REFERENCE GUIDE

Micro IV Operation Manual

EasyLog Data Logger Series

Dräger Pac Ex 2. Elegant and smart... Explosive hazards and lack or surplus of oxygen under control

ENMET Corporation. PO Box 979 Ann Arbor, MI RECON. Manual. Manual Part Number MCN-410, 12/03/08

1, 2, 3, and 4-Gas Detector. Technical Reference Guide

Single Gas Monitor 777

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

up to 1.2 m or 3.9 ft. deep). So if you drop the Honeywell BW Ultra in a vat or take it into a dust-prone environment,

Hygrometer / Air Quality Meter

Dräger X-am 5000 Multi-Gas Detection

Instruction Manual Eagle Series

Single Gas Clip and SGC Plus User s Manual Rev 2.3

EasyLog Data Logger Series

Dräger X-am 5000 Multi-Gas Detection

Dräger X-am 2500 Multi-Gas Detection

VENTIS PRO SERIES. Product Guide

1, 2, 3, and 4-Gas Detector. Technical Reference Guide

1.1 Definitions of alert icons. For your safety

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL THL1

Leak detector for refrigerant gases R22, R134a, R410A, R407C...

G450. Multi-gas Detector. Field Operation Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

EL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface

User Manual R1.0 CO2Meter, Inc. Personal CO2 Monitor SAN-10

Gas Detection. Honeywell BW Solo. The next generation in portable single gas detection.

USER MANUAL USB Multi-Function Datalogger Model RHT35

BW Clip4. Portable Gas Detector. Operator Manual

Micro III (Models G203, G203S, and G213) Operation Manual

Contents. Outline of Product. Features of Product. Specifications of Product. Name and central function of section. Illustration of Terminal

Operating Instructions and Maintenance Manual

Single Gas Clip and SGC Plus User s Manual Rev 2.1 READ FIRST BEFORE OPERATION WARNING STATEMENTS / AVERTISSEMENT Activating tthe detector for the

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger

IT S WHAT S INSIDE THAT

Dräger X-am approved as type MQG 01** Multi-Gas Monitor. Technical Handbook. CO2 Vol% CH4 %UEG. CO ppm. ppm NH _01.

MGC Dock User s Manual

Dräger Pac 8500 Single-Gas Detector

QD6310. Fixed Gas Detector Operation Manual

RECON/4a Portable Multi-Gas Detector Operation and Maintenance Manual

ULTIMA X5000. MSAX5000.com

MSA Portable Gas Detection

ALTAIR 5X Multigas Detector

MGC Dock User s Manual

GX-2009 Portable Gas Monitor Operator s Manual

multi-gas detector Go the distance, and save Wear yellow. Work safe.

Dräger X-am 7000 Multi-Gas Detection

GasAlertMicro 5. 1, 2, 3, 4, and 5 Gas Detectors. Quick Reference Guide

ALTAIR 4 Four Gas Multigas Detector

EL-USB-1-LCD Temperature Data Logger with LCD

Transcription:

BST-MG0S/09 Multi-gas Detecting Alarm Manual Instruction 1. Application: This product is designed to ensure safety for users who work in dangerous places. It's used for detecting CO, 02, H2S, CH4 simultaneously and alarm users by light, sound and vibration. This device is portable, anti-explosion and intrinsically safe. 2. Features: 1. Measured gases: Combustible Gas(LEL/CH4), Oxygen(02), Carbon Monoxide{CO), and Hydrogen Sulfide(H2S). Contact manufacturer for other gas combinations. 2. It will alarm users by sound, vibration, and light with different intensity if actual 3. Operation: concentration is higher or lower than preset alarm points. 1. 4 buttons included. 0 On/Off button; OK button;.a. Up button; -.. Down button 2. Long press 0 On/Off button to activate the device. It will show below information in turn: A. Product brand B. Low Alarm [L) C. High Alarm [HJ D. STEL Alarm [SJ E. TWA Alarm [T) F. Preset Calibration Value G. Product number and next calibrate date, 30 seconds countdown H. Auto Zero option BESANTEK LLJLIU Al..i\Rll [SJ[T] ll:ii! Ml. 0. 00 02 20 9 ['l>l'ol] co [Pl'M) H2S 0 [PPM] 0 2Q16. 09. 22 II ::\i; II Alarm (9 Time / Calibr- -ation Setting LOGO Main Interface Function interface 3. In auto zero option, after seeing "Adjust Zero?", long press "OK" button to zero all sensors, short press " 0 " button to exit. When the device is zeroed in unfresh air, the system will zero itself when the device is back to fresh air, no need to worry about the accuracy. 4. In main interface, it shows 4 alarm icons on top area: [LI, [HI, [SI, [Tl, if there is any alarm, the corresponding icon will turn red. Short press ".A." to switch among STEL, TWA, PEAK, and MIN. No operation for 30 seconds will bring it back to main interface. 5. Long press "OK" button to enter function interface. Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com

6. In function interface, short press "..A." or "T" to select function, then short press "OK" button to enter corresponding function. 7. In zero interface, short press "..A." or "T" to select gas, long press "OK" button, the background of selected gas will turn red, long press "OK" button again to complete the operation with display "set OK". If there is no "set OK" showed, it means operation is failed. Short press 110 11 to exit. Notice: Use 100%vol nitrogen gas to zero oxygen sensor, for other sensors, it can be done in fresh air. m Zero Alarm Set Alarm[L] CH4 ('IVOL) 0.00 02 ('IVOL) 20.9 co [PPJJ) 0 Set low Alarm CH4 [\VOL) 0.00 Set High Alarm 02 Set STEL Alarm [\l'ol) 20.9 co Set TWA Alarm [PPll] 0 H2S [PPM) 0 H2S [PPll] 0 Zero Interface Alarm Set Low Alarm setting 8. In alarm interface, short press "..A." or "T" to select among "Set Low Alarm", "Set High Alarm", "Set STEL Alarm", and "Set TWA Alarm". Short press "OK" button to enter each setting "Alarm[L)", "Alarm[H)", "STEL[S]", "TWA[T]", short press "..A." or "T" to set the value, long press "OK" button to complete the operation with display "set OK". Short press "0" to exit. 9. In time setting interface, short press "OK" button to select "Year", "Month", "Day", "Hour", "Min", then press "..A." or "T" to adjust the value. Long press "OK" button to complete this operation with display of "Set OK". Short press "0" to exit. (9 Time l'h 2013 Month: 02 Day: 18 Hour: 09 IL! Calibration Set Set Value Common Calibration 121 Common CH4 [%VOL] 0.00 02 [%VOL] 20.9 co [PPll] 0 J:vlin: 30 H2S (PP\0 0 Time Setting Calibration Setting Common Calibration 10. In calibration setting interface, short press "..A." or "T" to select between"set Value" and "Common Calibration" A. "Set Value": user should input available calibration gas concentration here, short press "OK" button to select among gases and short press "..A." or "T" to adjust gas values, long press "OK" button to complete this setting with display of "Set OK".

Important: user should make this setting before following operations. B. In "Common Calibration" interface, short press".a. 11 or "'f//f II to select gas, long press "OK" button, the background of selected gas will turn red, connect calibration gas and after the value is stable, long press "OK" button to complete this operation with display of "Set OK". Short press "C) 11 to exit. Notice: a. Before calibration, activate this device for at least 6 minutes to allow it run stably b. When the device is alarming for low power, stop calibration and charge it right away c. Calibration gas must be standard gas used for calibration purpose d. Zero sensors firstly before calibration e. Make sure gas flow is stable before connecting calibration gas, calibration gas flow for CH4, CO, 02 is 200ml/min, 300ml/min for H2S. f. Suggested calibration gases are as following: CH4 1.00%vol, CO SOOppm, H2S S0ppm, oxygen can be calibrated in fresh air 11. In setting interface, short press,,.a." or,, 'f//f " to select among "CH4", "LEL", "PPM", "MG/m 3 ","Allow Calibration", " 11 means item is selected. Long press "OK" button to select and confirm. Short press "<9 11 to exit. Important: User can't enter calibration interface without choosing "Allow Calibration" 4. Technical Parameter: Technical Parameter Specification Measured gas Methane{CH4), Oxygen(O2), Carbon Monoxide{CO), Hydrogen Sulfide{H2S) Methane (CH4) Measurement range (o.oo~s.oo)%vol Measurement error (o.00~1.00)%vol: ± 0.10%CH4 (1.00~3.00)%vol: True value± 10% {3.00-5.00)%vol: ±0.30%CH4 Respond time 20s (T90) Resolution 1.00%vol (Adjustable for full 0.01%vol Alarm point range) Oxygen (02) Measurement range (o.o~3o.o)%vol Measurement error (o.o~s.o)%vol: 02: ±0.5%vol (> s.o~3o.o)%vol: O2:0.9%vol Respond time 35s (T90) Resolution 18.0%vol{Adjustable for full range) 0.1%vol Alarm point 25.0%vol{Adjustable for full range) Carbon Monoxide (CO) Measurement range (0~1ooo)ppm Measurement error (0~2o)ppm: ± 2ppm (>20~10o)ppm: ±4ppm Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com

Respond time (>10o~soo)ppm: True Value±S% (> soo~1ooo)ppm:true value± 6% 45s (T90) Resolution lppm I Alarm point I 24%vol{Adjustable for full range) Measurement range Measurement error Respond time (0~1oo)ppm Hydrogen Sulfide {H2S) (o~so)ppm: ±3ppm ( > so~100 )ppm: ±10% 45s (T90) Resolution lppm I Alarm point I 1oppm(Adjustable for full range) Sensor lifetime Alarms Charging time Continuous operating hours Battery model CH4: 1 year CO,H2S,O2: 2 years Audible--buzzer with 85dB @lm audible Visible--flashing red LED, 20m visible Vibration 4-Shours 13 hours PL123450, 3.7V/1500mA Protect Grade IP66 Working temperature -2s c ~ so c Size(mm) 130*70*37 Data logging for Continuously data logging MG08 only (100000 records with 1-10 minutes interval) Enclosure Display PC+ABS with resistance 10-9 Q Color Screen LCD Safety Standard: - CE: EN 50270:2006 MA/KA: GB3836-2010 EX: GB3836.1-2010 & 3836.4-2010

External Sampling Pump Manual Instruction Product description: This gas sampling pump can be used with any po1table gas detectors, and detect target gas as far as 30 meters. With 4 LED indicators, user can know power left easily. Technical parameter: Samplin2 Air Flow Samplin2 Distance Workin2 Temperature Workin2 Humidity Power Source Output Input CharITTn2 Time Weight 1600ml/min 30m -20,...,500 90%RH 3. 7V rechargeable lithium batte1y SW DCSV IA 8h 200g How to turn ON and OFF this pump: Long press power switch to activate this pump and long press power switch again to shut it off.

1. Gas Detector Data Collection Setting Gas Check User's Guide 1.1. Activate gas detector by long pressing <!) button. 1.2. Long press OK button to function inte1face 1.3. Press up/down button and choose "Setting", enter it by sho1t pressing OK button 1.4. Press up/down button and choose "Data Store",enter it by sho1t pressing OK button Use: The amount of data have been collected & stored Total: Total amount of data can be collected & stored Time: Configurable time inte1val between l-600s for data collection Stop: Stop data collection. Sho1t press OK button to switch between "Stop" and "Sta1t", long press OK button to confi1m. Start: Strut data collection. Sho1t press OK button to switch between "Stop" and "Sta1t", long press OK button to confilm. 1.5. After well setted, user can find on top of detecting inte1face, which means device is collecting& sto1ing data. Notice: when gas detector is connected with Gascheck software for real-time data collection, gas detector data collection will be out of work. 2. Gascheck Driver and Software Installation 2.1. Open CD-Rom Driver on your computer and put the offered CD into it 2.2. Read the CD and find Gas Check Driver programme, then choose light file according to your computer OS. 2.3. Double click "Prelnstaller.exe" or "CP210xVCPinstaller.exe" and click "Install", then you'll see window prompt with "Installation Successfully". 2.4. To confilm this diiver has been installed successfully: light click "My Computer''and choose "Device manager" and unfold "Po1t (COM and LPT)" you'll find "silicon Labs CP210x USB touart Blidge". 2.5. Find "Gas Check Setup", install this softwai e by double clicking this setup, follow window prompt for installation Notice: Before connecting gas detector with Gascheck software, please install & iver firstly, or gas detector can't be recognised by software. 3. Gascheck operation 3.1. Double click "Gas Check" icon on your desktop, and connect with activated gas detector using USB cable. 3.2. Click "Connect"to connect gas detector with this software, after well connected, status will become "Connected"and model number will come out. Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com

3.3. After connection, date and time on gas detector will synchronize automatically with computer. "Real-time" is for collecting real-time data, these data will only store on computer, check&analyze these data on "Data show" section "Real-time data". "History data" is for checking data collected by gas detector or data have been stored on computer A. Real-time data collection and checking Real-time m Every - minutes once Modify 1. Click "Modify" to set inte1val time from 1-10 min, click "Save"to confum. 2. Switch "Real-time" ON, you'll get real-time data and they will be shown on "Show Data" chart. 3. Stop real-time data collection by switching OFF. Show data Real-time data D Hist01ydata BST MG06001 00 2014 07 03 V 2014 07 03 V 0 li2s l"j 02 l"j CO l"j C}{4 B. Gas detector data collection and checking 1. Click "Get data" to get data collected by device, time needed is 1-6 minutes, device will show "Loading" during this period. 2. Check&analyze these data on "Data show" section "Histo1y data". 3. This softwai e can get and store data from several gas detectors, when data acquisition finished for one device, click "Disconnect" and connect with another one. 4. Click "Clear data" to delete all data collected by gas detector 5. When collecting data by device, user has 2 operation methods a. Set device following "Gas detector data collection setting" b. Set "Device setting" on softwai e iifii::1 14 MW, l1l hiiiilll 11111J 1 )Set valid sta1t and stop time, click "Modify" to set time inte1val from 1-10lll, then click "Save" to finish. 2)User will find on top of detecting inte1face, which means device is collecting& st01ing data. 3)Accident power ON or OFF duiing strut and stop time will not affect data collection, after restarting, data collection will go on. 3.4. "Show data" section Tick the colorful boxes to choose gases needed to be shown up on chart. "Real-time data" is for real-time collected data.

"Histo1y data" is for data collected by gas detector and data have been stored on computer. "Select device" to see available histo1y data of a ce1tain gas detector. "DEL" is to delete just model number of gas detectors which have been registered on this computer, this function is for a better management of more than one gas detector you use. When you register it the second time, you'll find all histo1y data. User can also check data in a ce1tain day by setting sta1t-stop time, strut and stop time need to be in same d a y; if not, you '11 get min, ave, max values for each gas and each day. Place mouse pointer on any point of collected data cmve, you'll get exact time and concentration of this data. Press left mouse and drag from left to light to spread all detailed d a ta points, and drag from 1ight to left to pull back, or click cross point of x and y axises to pull back. On 1ight side of the cha1t, you'll find 3 gas analyzing circle diagrams with "Avg" "Min""Max", tick circles below to see analysis for each gas. Click "Disconnect" to disconnect this gas detector with softwai e, stan1s will become: Disconnected Show data Reol-lrn.. Hoslo1y dolo 2014-07 04 V 2014 07 04 V Search 0 H2S 12 02 Cl co Cl Cll4 02 X:2014-7-4 11:05:06 Y: 14. 2?!vol CO:ppm 0 0 0 - to - Export Search ------------------------ Click "Expo1t" to expo1t data in excel fo1mat.