INSTALLATION AND USER'S GUIDE

Similar documents
MW001 Integrated Dishwasher. Manual for Installation, Use and Maintenance

Pump WaterVISE, FloVISE

User Manual. Dishwasher ZDM17301SA ZDM17301WA

FAVORIT DISHWASHER USER MANUAL

FAVORIT34502VIO. EN User Manual

FAVORIT 34502VI0. EN User manual

User manual. Dishwasher ZDT15002

Instructions for installation and use English. More documents on: H B /09

User manual. Dishwasher ZDT12041FA

User manual. Dishwasher ZDI12001

User manual. Dishwasher ZDI12010XA

FAVORIT W0P. EN User manual

User manual. Dishwasher ZDT15010FA

FAVORIT VI DISHWASHER USER MANUAL

User Guide. For THE SWIMSUIT DRYER. Swimsuit Dryer manual Final 120v 60Hz. Copyright 2017 Page of 20

User manual. Dishwasher ZDF14001WA ZDF14001KA ZDF14001SA

MP920 SALT CHLORINATOR

FAVORIT W0P. EN User manual

MW401 Integrated Dishwasher

wc431 Slimline Integrated Dishwasher Manual for Installation, Use and Maintenance

HX-30/40 and HX-30/40 S Glass and Dishwashers

15KW ELECTRIC FAN HEATER

FAVORIT 66609M0P FAVORIT 66609W0P. EN User Manual

30KW ELECTRIC FAN HEATER

5KW ELECTRIC FAN HEATER

POOL WINTERIZING INSTRUCTIONS

Installation, Operation & Maintenance Guide

Adjustable Electric Heater

Installation Instructions & Operating Manual

Installation and Operation Manual

RC411 Operator Manual

Glass and Dishwashers 402/452/502. (original instructions) (incl. Australian /502) Starting from Serial No.:

User Manual Dishwasher FAVORIT 56302MO FAVORIT 56302WO

TWLRZ-238 REFRIGERATOR

CE Unit is suitable for material transport. The transported gas may be up to 80 C.

User Manual Dishwasher FAVORIT 66602VI0P

MW402 Integrated Dishwasher

User manual. Dishwasher ZDTS102. Downloaded from manuals search engine

INSTRUCTION MANUAL HAND HELD STEAM CLEANER JQ688A-1

Get usage advice, brochures, trouble shooter, service information: Register your product for better service:

ISTRUZIONI PER L USO. Climatizzatore CT300 - CT300H

DELUXE COLLECTION Executive Filtered Water Cooler AQP-WCM-FBOT4

1. Information before installation General terms of delivery, storage and transport

INSTRUCTIONS FOR CARBON INFRARED HEATER

User Guide. For THE SWIMSUIT DRYER. Swimsuit Dryer manual Final. Copyright 2014 Page of 20

ESL 5201LO EN DISHWASHER USER MANUAL

INSTALLATION AND OPERATION MANUAL

WC141 Integrated Dishwasher Installation, Use and Maintenance

WC600 Integrated Dishwasher Installation, Use and Maintenance

GETTING STARTED? EASY.

GLASS DECORATIVE COOKER HOOD INSTRUCTION MANUAL READ AND SAVE THE MANUAL BEFORE INSTALLATION AND USE

WF140 Freestanding Dishwasher

Installation & Operating Instructions. Models: York Midi & Serrano Electric Stoves

DH 100 P. Always Dry dehumidifier. with. Condensation Removal System

instructions OIL FILLED RADIATOR V V and V551225

GETTING STARTED? EASY.

CONTENT PAGE INFORMATION INSTALLATION BREWER SETUP BREWING CLEANING KEY BREWER GRINDER MANUAL MODE DILUTION GRINDER MODE PACKS MODE

HOT WASHER MODEL NO: KING150

READ AND SAVE THESE INSTRUCTIONS

Closing procedures for in-ground pools

CHH30 Dishwasher. Wiring Diagram. Spare Parts List. Installation / Operation

2.8KW ELECTRIC FAN HEATER

3. Before switching the equipment on, make sure that the model plate data conforms to that of the electrical and water distribution network.

INSTALLATION MANUAL GUTHD2. Universal Two Way Digital Thermostatic Valve for Shower Systems

PANEL RADIATOR. USER MANUAL HSDOnline.co.uk 2KW OIL FILLED POH04

Glass and Dishwashers AMX / AUX Series

WC370 Integrated Intelligent dishwasher Manual for Installation, Use and Maintenance

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

Adjustable Standing Patio Heater 2000w

/09.15_00. De Longhi Appliances via Seitz, Treviso Italia

SAND FILTER PUMP MANUAL

Solar Pool Ionizer and Purifier

installation and operation manual for Hunter Ceiling Fans

HW3 Handwash Installation and Operating Instructions

Menumaster. Commercial Microwave Oven Use and Care Manual CFSP70 GSAND-7D SAND-7D SAND-700

smardy - pure water Reverse osmosis system YR100-A 75 GPD

User Instruction &)+ 4: CFH110QB

INSTALLATION AND USER MANUAL

EN Bagged Vacuum Cleaner

16 Stand Fan with Remote Control Model No: FS3-40R-30

OPERATING INSTRUCTIONS

Safety Is a Good Habit to Get Into

OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS

Slimline Dishwasher Instruction Manual

Closing procedures for above-ground pools

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

Installation and Operation Manual For Hunter Ceiling Fans

Bar Fridge USER MANUAL MB46W

INSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / , , , IMPORTANT INFORMATION

DOMESTIC STEAM GENERATOR Installation Instructions

Instructions for installation

User manual. Washing Machine ZWP 581 ZWQ 5102 ZWQ 5103 ZWQ 5122

Operating instructions for the radio heat detector GS412

Water Boilers ME10EN, ME15EN. Table of Contents

Rapide Deluxe PT. User Guide V-026PTS. Performance is everything. vax.co.uk

CHAMPION PUMP OWNER S MANUAL

HARTFORD SLIM ASSEMBLY INSTRUCTIONS. IMPORTANT - RETAIN FOR FUTURE REFERENCE - READ CAREFULLY.

Lifting Station Type ABS Sanimax

1. Information before installation General terms of delivery, storage and transport

Transcription:

INSTALLATION AND USER'S GUIDE FILTRATION BLOCKS Infinity (U) 25 m 3 /hour and 20/50 m 3 /hour Equipment of high-alloy steel for cleaning and filtering water in the pool

2

TABLE OF CONTENTS Page APPLICATION. 4 SHORT IMPORTANT INFORMATION.. 4 DISPOSAL of PACKAGING... 4 1 INTRODUCTION TO THE FILTRATION BLOCKS INFINITY (U) COMPLETE SET... 5-8 The general scheme. 5 INFINITY without heating 6 INFINITY + heat exchanger with electronic thermostat.. 7 INFINITY + electric heater flow type with a control unit. 8 2 - DIMENSIONS OF EQUIPMENT... 9 3 - INSTALLATION AND CONNECTION. 10-13 Installation of the technical part... 11 Ventilation.. 11 Grounding 11 Connecting to water supply network 12 Compound filtration compartment with the technical part. 13 Connection to drainage system... 13 4 - SAFETY AND WARNINGS. 14 Electrical safety. 14 Electrical cables. 14 Differential switch 14 Other security measures 14 5 ELECTRICAL CONNECTIONS... 15-20 Electrical control panel.. 15 Wiring diagram of the electrical control panel.. 16 Connecting boxes...... 17-18 Electrical wiring diagram of heat exchanger. 18 Hydraulic wiring diagram of heat exchanger. 19 Table of circulation pumps for heat exchanger. 19 Wiring diagram of electric heater.. 20 6 PUTTING INTO OPERATION.. 21 Filling of swimming pool 21 Adjusting the device of automatic water adding. 21 Initial start-up 21 Timer setting for electrical control panel 21 7 FILTRATION MEMBRANE... 22 Replacement and cleaning 22 8 - VACUUM CLEANER CONNECTION AND OPERATION. 23 9 REPLACING THE BULB IN SPOTLIGHT. 23 10 DISINFECTION OF SYSTEM... 24 Parameters of a weekly chlorination... 24 рн 24 11 CARE PRODUCT 25 12 MALFUNCTIONS.. 25 13 - MAINTENANCE OF EQUIPMENT IN THE WINTER 26 14 TECHNICAL SUPPORT CENTER.. 26 CERTIFICATE OF WARRANTY.. 27 WARRANTY CONDITIONS. 28 3

APPLICATION Congratulations on the purchase of modern high-quality products. Filtering block Infinity is designed for cleaning and filtering water in the pools of all types. The combination of efficiency and a more simplified operation will bring you satisfaction. Please carefully read this guide for a secure connection, effective operation and proper maintenance of the product. Keep the user guide for subsequent use or for next owner. Serial number of the filtration unit is shown below. This will help get more detailed answers to your questions at the center of technical support. The guide is structured in such a way that you step by step to carry out the necessary work. The manual contains instructions for connection, operation and maintenance of this product. To facilitate access to information manual provided with the content. Follow the advice and guidance contained in this user guide, and VSV Aqua Group products will make you happy for a long time. SHORT IMPORTANT INFORMATION Do not use Filtering block Infinity (U): - without grounding; - in pools with sea water; - in pools with ozone or electrolysis system. To avoid corrosion it is important to follow these instructions: 1. The pool must maintain required ph, chlorine, salts, etc. The ph in the pool should be in the range from 7,2 to 7,6. If the level of ph above 7,6, then in water will precipitate calcium salts, which will fall on the stainless steel equipment. If the ph is below 7,0, the water is highly corrosive, which also adversely affects the status of stainless steel products. The content of free chlorine in the pool water should not be higher than 0,5 mg / liter. Excess chlorine contributes to the formation of rust. 2. Adding to the pool of chemicals should be performed at a sufficient distance from parts made from stainless steel to avoid getting chemicals on stainless steel equipment. Otherwise, on the surface of stainless steel can form rust and turbidity. 3. Spread the chemicals in various fields of the basin. Do not add the chemical in one place, it could lead to the formation of regions with high acidity, which can lead to corrosion of the equipment pool. Always use floating dispensers when you adding chemicals. A complete description, see Section 10 "Disinfection System." 4. Check the filter membrane. Keep your pool clean, do not allow accumulation of leaves, grass, etc. Their decay can lead to increased ph-factor. 5. Do not allow that on the surface of stainless steel remained dust, cement, dirt during the construction of a swimming pool. Avoid contact of stainless steel with other materials (especially iron), as this may lead to the formation of yellow pigments, especially at the welded joints in filtration unit. 6. All the polished surface of the product require periodic care by special means (not use abrasive cleansers). In the indoor pool concentration of corrosive vapors resulting from the use of chemicals, higher than outdoor pools, so the indoor pool cleaning parts from stainless steel should be performed more frequently than in the open. 7. Stainless steel parts should not be stored and transported close to the chemical reagents and dosing devices. In case of violation of these requirements, the manufacturer is not liable for the loss of the appearance of products, qualities and properties needed for full operation. DISPOSAL of PACKAGING The packaging material was used to protect equipment during transportation. The packaging recyclable and does not harm the environment. Please make a contribution to environmental protection and return the packaging for environmental disposal. Warning! Do not let children play with the packaging. They can choke locked in a box or entangled in the packaging film! The manufacturer reserves the right to make changes without notice in design and component products. 4

1 INTRODUCTION TO THE FILTRATION BLOCKS INFINITY (U) COMPLETE SET This guide is valid for several models of filtration blocks Infinity. Therefore, can be some differences in the drawings. The general scheme 25 m 3 /hour and 20/50 m 3 /hour The filtering part includes pre-filter basket + cover for connection with water vacuum cleaner, standard filter membranes (6-15 microns), front skimmer, nozzle, LED lights 2x10W 12000K, pneumatic switch button of spotlights, pneumatic button for counter flow function, the device of automatic water adding, the suction pipe with pre-filter, grounding bolt. Technical part depending on the model ladder includes one-speed pump 220V (in model Infinity 25) or two-speed pump 220V with a control unit for the function of counter flow (in model Infinity 20/50), the transformer spotlights, drain outlet, connection box, connecting pipes, grounding bolt. The technical part can be installed at distance of 3 meters (minimum) and 7 meters (maximum) from the pool. Electrical control panel includes a timer, a differential switch (breaker), fuses, mode selector switch, LED lights switch. 5

BLOCK Infinity (U) 25 m 3 / hour BLOCK Infinity (U) 20/50 m 3 / hour INFINITY without heating Total assigned power of 0,82 kw (with spotlights 2х10W): - one-speed pump 0,8kW (50Hz) - performance (capacity) 25 m 3 /hour - height (H) max. 14 m Total assigned power of 1,62kW (with spotlights 2х10W): - two-speed pump 0,3/1,6kW (50Hz) * - performance (capacity) 20/50 m 3 /hour - height (H) max. 19 m * The counter flow The counter flow activated by pressing a pneumatic button on the instrument panel in the filtering part (only in models with two-speed pump Infinity 20/50). WARNING! Do not leave the filtration turned on for a long time in a counter-flow mode, as this function is not designed for continuous operation. The technical part without heat exchanger / electric heater 6

INFINITY + heat exchanger with electronic thermostat (for use with boilers) Heat transfer 15 kw min. - 70 kw max. BLOCK Infinity (U) 25 m 3 / hour + heat exchanger Total assigned power of 0,823 kw (with spotlights 2х10W): - one-speed pump 0,8kW (50Hz) - performance (capacity) 25 m 3 /hour - height (H) max. 14 m BLOCK Infinity (U) 20/50 m 3 / hour + heat exchanger Total assigned power of 1,623kW (with spotlights 2х10W): - two-speed pump 0,3/1,6kW (50Hz) - performance (capacity) 20/50m 3 /hour - height (H) max. 19 m The technical part with heat exchanger 7

INFINITY + electric heater flow type with a control unit (capacity 12 kw) BLOCK Infinity (U) 25 m 3 / hour + electric heater Total assigned power of 1,82kW (with spotlights 2х10W) 13,25kW (with electric heater 12 kw) - one-speed pump 0,8kW (50Hz) - performance (capacity) - 25 m 3 /hour - height (H) max. 14 m BLOCK Infinity (U) 20/50 m 3 / hour + electric heater Total assigned power of 1,62kW (with spotlights 2х10W) 13,62kW (with electric heater 12 kw) - two-speed pump 0,3/1,6kW (50Hz) - performance (capacity) 20/50 m 3 /hour - height (H) max. 19 m The technical part with electric heater 8

2 - DIMENSIONS OF EQUIPMENT 9

3 INSTALLATION AND CONNECTION Place the block on the wall of the pool, as shown below, taking care not to damage the waterproofing coating (liner). If necessary, align it with the water level and fasten the block mounting bolts in a projected place. TOP VIEW POSITION OF THE HOLES FOR FIXING BOLTS 10

Installation of the technical part Preparation of the basis for technical compartment The technical part should be installed in Zone 2 (VDE 0100-702). To install the technical part, create a foundation of sand and rubble. Thickness of a basis should provide the satisfactory base. Sizes of the pit should not restrict your access for installation of the pipeline and electric cables. The upper edge of the technical part without the cover should be the same level as playground around swimming pool. Align the technical compartment and make backfill by sand. VENTILATION Warning! Never cover the ventilation holes in the lid of the technical compartment. Otherwise the equipment will have to work with increased productivity, which increases power consumption and can cause overheating and damage of motor. Grounding Perform the grounding of the filtration equipment according to the norms of your country. Connect the filtration equipment to the ground by flexible copper wire cross section of 10 mm 2. WARNING! Absence of grounding life-threatening. If your filtration equipment is not connected to ground or incorrectly grounded, there is the risk of corrosion because of the potential difference. The manufacturer cannot be held responsible for any damages arising from absence of grounding or an incorrectly grounding. 11

Connecting to water supply network Connecting to the water supply network must necessarily be conducted before the electrical connection by a competent person in accordance with local Requirements developed by the company responsible for water supply in your area. Adding of water Bring the pipe to filtration unit and connect it to the inlet (thread 3 / 8 inches), provide a tight seal. Filtration unit must be connected to the water supply of cold water with a hydraulic pressure not exceeding 4.5 Bar, because the device of automatic water adding is designed to pressure 4.5 Bar (max). Adjust the screw after filling the pool. Water must be 1 cm lower of the upper edge of skimmer (see pict.). 12

COMPOUND THE FILTRATION COMPARTMENT WITH THE TECHNICAL PART a) compound with a pump Connect each input and output apertures with pipes diameter 50 mm, as specified in Section 3 "Installation and connection." Pipes must be laid in such a way that they form expansion joints to prevent damage to pipes due to thermal expansion. Pipelines must be laid at a depth corresponding to the climate zone for your region. b) compound with a pneumatic button of counter flow To avoid damage to the pneumatic tubes, it is necessary to lay her in a protective tube of suitable diameter. Spend a pneumatic tube through a seal in body of the technical part. Connect the pneumatic tube with pneumatic button on the dashboard of the filtration unit and with pneumatic button of control unit of the pump in the technical part (for model Infinity 20/50). WARNING! Not bend the pneumatic tube! c) laying of cables spotlights (Follow the instructions in Section 4, "Safety instructions and warnings"); Lay the protective pipe of suitable diameter between the filtering part and the technical part. Spend inside a pipe flexible copper cable 2 x 2,5 mm 2. One end of the cable must be in the technical part near the transformer of spotlight. Other end must be near the terminals in the filtering part. With the help of terminals make connect cable wires in the filtration compartment. Connect terminals between themselves and slide pipe on the terminals. Heat the pipe by air-heater so that it is tightly compressed terminals. Connect the second end of cable to transformer. Tighten cable gland in the technical compartment. d) compound with a pneumatic button of spotlights To avoid damage to the pneumatic tubes, it is necessary to lay her in a protective tube of suitable diameter. Spend a pneumatic tube through a seal in body of the technical part. Connect the pneumatic tube with pneumatic button on the dashboard of the filtration unit and with pneumatic button of control unit of the pump in the technical part. WARNING! Not bend the pneumatic tube! Connection to drainage system DRAINAGE With the help of tubes 50 mm in diameter, connect the drainage pipe of filter equipment with a drainage system. Create a slope pipelines to avoid raising the water level inside the technical part. WARNING! Follow the connection so that water from other drainage systems does not leak to drainage system of filtration unit. 13

4 - SAFETY AND WARNINGS Before introducing the equipment in operation carefully read the instructions on installation and operation! Make sure you understand all instructions. Do not take any action not described in this guide, as this could lead to a situation dangerous to humans and / or equipment. ELECTRICAL SAFETY To avoid danger of injury or electric shock when connecting and using your equipment, always follow safety standards in your country and observe the rules of connectivity, developed by local companies for electricity. All electrical connections must be performed by a qualified person in compliance with the enclosed instructions and wiring diagrams. Connections shall comply with electrical codes in your country. Electrical control panel for the filter should be installed no closer than 3.5 meters from the pool. All connections in the electrical control panel should be tightened. At the beginning of the power supply circuit electrical control panel should be fuse 16 A (before differential protection). An all pole disconnection should be provided in the fixed wiring. ELECTRICAL CABLES Perform the electrical connection with a copper cable 3 x 2,5 mm 2 (for cable lengths up to 20m) by acceding to the upper terminals of the differential switch in the electrical control panel of filtration equipment with the correct polarity. It is necessary to laid cable in a protective tube. If the cable is not protected you must install warning tape on top of the cable. Under roads cables are laid at a depth of not less than one meter. In all other cases, the depth of the cable - 0.6 m WARNING! The technical part with electrical equipment should be securely closed with a cover and fixed with screws. Disconnect power supply before performing any operations in the technical part of the equipment. Filtration unit must be connected to ground (see section Grounding ). Please check the rules of your country. DIFFERENTIAL SWITCH Attention! Filtration unit is connected to power supply only through the differential switch 30mA. Your electrical control panel has a differential switch, which provides special protection against electric shock and disables the filtration unit in the event of an incident. IMPORTANT NOTICE! You should check the differential switch at least once a month. To test, press the test button on the differential switch. At the time of triggering of the security mechanism you should hear a click OFF. Then turn ON the differential switch again. When testing the differential switch must be under tension. If you pressing the test button and differential switch does not turn off, you must disable electricity and contact a qualified electrician. OTHER SECURITY MEASURES Filtration equipment is not intended for use by person (including children) with reduced physical, sensory or mental capabilities, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the equipment. 14

5 ELECTRICAL CONNECTIONS Electrical control panel 15

WIRING DIAGRAM OF THE ELECTRICAL CONTROL PANEL Connection of power supplies is made to the upper terminals of the differential switch, observing polarity. Power supply cable for pump and transformer of spotlight is connected to terminals according marking on the cable wires and according to the attached scheme. 16

CONNECTING BOXES of the filtration blocks Infinity (U) Enter the power supply cable for pump and transformer of spotlight in the technical part through O-ring. Tighten the nut of seal to avoid getting water into the technical part. Enter the cable into the connection box and connect the wires according to the scheme. Connecting box without water heating Connecting box with Heat exchanger 17

Connecting box with electric heater ELECTRICAL WIRING DIAGRAM of HEAT EXCHANGER Connect the filtration unit with electrical control panel according to this scheme. electric control panel of filtration unit thermal protection switch switch phase (from electronic thermostat) heat exchanger circulation pump electromagnetic valve N 18

HYDRAULIC WIRING DIAGRAM OF HEAT EXCHANGER Connect the heat exchanger with gas boiler according to the attached scheme. circulation pump of heating circulation pump of heat exchanger 3-position valve valves thermal protection switch pipe 26/34 boiler non-return valve electromagnetic valve filtration unit electrical control panel expansion tank technical compartment of filtration unit heat exchanger pump electronic thermostat suction pipe discharge pipe Choose the circulation pump of necessary capacity according table below. Table of circulation pumps for heat exchanger Capacity of the circulating pump Power of the circulating pump 0,72 m 3 /h 15 kw 1,44 m 3 /h 29 kw 2,16 m 3 /h 44 kw 2,88 m 3 /h 59 kw 19

WIRING DIAGRAM OF ELECTRIC HEATER Electrical connection is made to the upper terminals of the differential switch, observing the phase rotation. Please note, that the cross section and amount of cable cores corresponded to your model of heater. Power supply single-phase heater Power supply three-phase heater - neutral; - phase; - ground; - neutral; - 3-phase; - ground; Electrical control panel - neutral; - phase; - ground; - neutral; - 3-phase; - ground; main power supply main power supply to electric heater control box Yellow-green Brown Blue cable 2x1,0mm 2 to connection box electric heater control box Brown Blue Yellow-green cable 2x1,0mm 2 to heater cable 4x2,5mm2 to heater cable 4x6mm2 to electric heater electrical control panel 3 phase fuse cable 1 phase fuse cable 6 kw 9 kw 10A 16A 4x2,5mm 2 4x4mm 2 6 kw 32A 3x6mm 2 12 kw 20A 4x6mm 2 20

6 PUTTING INTO OPERATION FILLING OF SWIMMING POOL Once again check connection of all pipes (see Section 3. "Installing and Connection") and start to fill the pool by water. Stop filling when the water reaches a level 1 cm below the upper edge of the skimmer (see "Connecting to the water network). PLEASE OBSERVE THE FOLLOWING REQUIREMENTS AT THE TIME OF FILLING THE POOL: If the water does not meet the established standards (not clean enough), you can use for cleaning of water the filter bag, which is included in the complete set of filtration unit. To do this, insert the hose into the filter membrane fix the membrane on the hose and start to fill the pool. At the end of the swimming pool filling, rinse the membrane by water under pressure. ADJUSTING THE DEVICE OF AUTOMATIC WATER ADDING To keep water in the pool always at one level (1 cm below the top of skimmer) necessary to adjust the screw of automatic water adding in filtration compartment. INITIAL START-UP Following the instructions from Section 4, "Safety and warnings", do the electrical connections. To remove air from the piping and pump, connect to the water supply flexible hose. WARNING Do not put the flexible hose in the discharge nozzle. Enough to keep the hose near the discharge nozzle. Stop filling pipelines by water when the air bubbles will stop. After filling the pipeline, make sure, that no leaks in the joints of pipes. Then fill the sand around the technical part and pipeline. Insert the filter membrane inside of filtration unit (see Section 7 "Filtration membrane). Turn on filter equipment and start primary cleaning of water in a manual mode. To do this, set the switch on the electrical control panel in "manual ". After two or three days of filtration unit in a manual mode, turn the switch on the electrical control panel in "automatic mode" and Install on a timer duration cycles of water filtration. TIMER SETTING You can use the timer of electrical control panel to set the daily filtration time of your pool. REMEMBER, the more often filtered swimming pool, the cheaper to maintain it! Adapt the time of filtering to water temperature (time of filtering = temperature of water divided by 2). For example, if the temperature of water in your swimming pool = 24 С, then 24:2=12 hours (time which filtration unit must work). To set filtration time, it is necessary carefully to pull out the segments. One segment corresponds to 30 minutes. To set timer s clock, it is necessary to rotate dial face clockwise until a set time. It is forbidden to rotate a dial face counter-clockwise, it can damage it. 21

7 - FILTRATION MEMBRANE WARNING! Do not operate the filtration unit without filtration membrane as it can break the motor. In filtration blocks Infinity water is sucked through the skimmer and cleaned through the filter membrane, then clean water flows back into the pool through a nozzle. Before the filtration membranes installed pre-filter basket designed to remove the largest size impurities, for example leaves. The efficiency of your filtration equipment will depend on cleanness of pre-filter baskets and filtration membrane. WARNING! Insert the filtration membranes into openings of the holding plate inside the filtration unit such a way that the lock ring should remain on the holding plate. Install the pre-filter baskets and switch on filtration unit REPLACEMENT AND CLEANING WARNING! Replacing contaminated filter membranes can be performed only after turning off the filtration unit. Switch off filtration equipment from power supply. Remove the pre-filter basket and rinse with water. Then remove the filtration membrane and rinse with water under pressure. You can washed filter bag in automatic washing machine at a temperature not exceeding 30 0 C, but in any case after being washed from a hose. Do not use any detergents. It is necessary clean the filter membranes not less than once a week, or when contaminated. Optimum service life of the membrane is two years. Do not use membrane after the expiration date. The manufacturer guarantees the quality of water treatment only with membrane VSV. WARNING! If near your pool there are leafy trees, please every time check pre-filter basket and from plugging with fallen leaves. This impairs the efficiency of the filtration unit and may damage the motor. Pure pre-filter basket improves the efficiency of the filtration unit. 22

8 - VACUUM CLEANER CONNECTION AND OPERATION Put down in the swimming pool a hose of vacuum cleaner. Keep a hose near the nozzle and fill with water. Take the cover from vacuumcleaner and insert on a pre-filter basket. Connect hose to the cover with hole and start cleaning of swimming pool. CAUTION! It is forbidden to use function of counter-flow for cleaning! WARNING! Vacuum cleaner hose must be tightly connected to the tip of hose to avoid air suction and getting into pump. WARNING! Do not connect the vacuum cleaner through the skimmer, it can damage the skimmer! When membrane during pool cleaning dirty, turn off the filtering from power supply, clean or replace the filter membrane. After cleaning swimming pool, again turn off filtration unit, remove the cover from the basket, replace the dirty membrane on clean. Then turn on filtering. 9 - REPLACING THE BULB IN SPOTLIGHT Disconnect the power supply of filtration unit. Rotate the spotlight in a clockwise direction until the latches spotlight will not fall into the grooves on the front of the filter. Pull out the spotlight from the water, slowly pull surplus of cable Take a spotlight s cup and unscrew counterclockwise decorative nut of spotlight. Remove a glass and take out a bulb. Replace by new bulb. Then assemble the spotlight in the return sequence. Densely tighten a decorative nut of spotlight. Insert a spotlight on the place of braces in the grooves, and then rotate in clockwise direction to lock it in place on the front of the filter. ATTENTION! Spotlight works only with transformer 230 / (2х12V, 10VA). 23

24 10 DISINFECTION OF SYSTEM WARNING! Excess of chlorine can cause a corrosion of the system. Make sure that the chlorine level was within the limits recommended by the manufacturer of chemicals, and are assigned to the type of pool, for example, private, hotel, school or municipality, but under no circumstances it should not be above 0.5 mg/liter. Put the chlorine tablets in the chlorinator (floating dispenser). Keep all chemicals out of reach of children, away from sunlight, in well-ventilated area. Never add to the pool at the same time two different products. Chlorine is the most effective way of disinfecting the pool water. Weekly chlorination For weekly chlorination use a slow-acting product. For example, 200 gram tablets dissolve slowly and continuously disinfect the pool water. Normally one tablet is enough for 20 m 3 of water for one week. Parameters of a weekly chlorination Required dose of chlorine depends on the frequency of bathing, water temperature, sunlight, and the size of the pool. To measure the amount of chlorine you must use the test kits. When ph adjusted Water volume Slow chlorination 40 m 3 2 tablets 50 m 3 2 tablets 60 m 3 3 tablets 70 m 3 3 tablets 80 m 3 4 tablets 90 m 3 4 tablets 100 m 3 5 tablets WARNING! When using chemicals from different manufacturers, the dosage may to change in depending on the concentration. Attentively read the instructions on the labels of chemicals. Summary: water in the pool always been a clean, you need every week to check the ph and chlorine in the pool and when need to make balance рн The ph is a measure of the acidity of the water. The ph scale goes from 0 to 14, where ph 7 is neutral. If the ph is above 7, the water is basic; if it is below 7 the water is acid. The optimum ph for pool water is 7.4, since this is the same as the ph in human eyes and mucous membranes. A ph of 7.4 also gives good chlorine disinfection. A low ph gives: - aggressive water, which damages the mechanical components of the pool - irritations of the eyes and mucous membranes - damage to the pool liner A high ph gives: - poorer chlorine disinfection - skin irritation - lime precipitation - cloudiness The guideline ph figure is 7.2 7.6.

WARNING! Do not use abrasive cleaners! 11 - CARE PRODUCT Filtration systems for swimming pools are made of high-alloy stainless steel. However, over time, depending on water quality and climatic conditions on the surface of the product may be formed of pollution in the form of lime or fatty deposits. Information about care product designed specifically for cleaning steel products, you can get online support center. 12 - MALFUNCTIONS Sometimes the cause of the problem can be easily eliminated. Therefore, before contacting the Service, check whether you can solve the problem yourself, as recommended below: 1. 2. 3. 4. 5. 6. 7. MALFUNCTION POSSIBLE REASON ELIMINATION Filtration unit does not work in a manual and automatic mode Filtration unit does not work in a filtration mode Filtration unit does not work in counter swimming mode Filtration unit spotlight does not shine (filtration unit is working) Filtration unit is working, but skimmer is closed In the water from discharge nozzle there are many air bubbles, the water flow is lower (acceptable operational mode) The water vacuum cleaner does not collect a dirty from a bottom of pool The water vacuum cleaner does not collect a dirt from a bottom of pool (filtration membranes are clean) Triggering of differential switch in the electrical control panel Power supply is switched off Triggering of safety fuse 6A in the electrical control panel Pneumatic button s pipeline is disconnected from the pneumatic button or from the pneumatic switch Triggering of a safety fuse 16А in the electrical control panel of filtration unit Triggering of heat protection in the pump s electric motor Pneumatic button s pipeline is disconnected from the pneumatic button or from the pneumatic switch Triggering of protection fuse in spotlight transformer Spotlight bulb burned out Filtration membranes are dirty Prefilter baskets are dirty Too much aeration in the water Filtration membranes are dirty Mouthpiece of vacuum cleaning hose is badly connected with hose Switch on the differential switch Check up, whether there is power in electricity network Replace safety fuse 6A Connect the pneumatic pipeline Check a safety fuse 16А Switch off a filtration unit for 15 minutes and switch on again. Connect the pneumatic pipeline Call service department Replace the bulb as written in section 9 on page 23 Replace or clean filtration membranes Clean prefilter baskets Switch off filtration unit for 30 seconds and then switch on again Replace or clean filtration membranes Take out the vacuum-cleaning hose from the cup, connect hermetically mouthpiece of hose with vacuum-cleaning hose. 25

13 - MAINTENANCE OF EQUIPMENT IN THE WINTER WARNING! representative. To make correct MAINTENANCE OF EQUIPMENT IN THE WINTER, contact your local WARNING! All electrical work must be performed by a qualified person in compliance with the enclosed instructions. If your filtration unit operated in a region where there is a risk of low temperatures, we recommend you to complete conservation for WINTERIZING (if the water freezes inside the filter, some parts of the filtration equipment can be damaged). For this purpose you should switch off the differential switch in the electrical control panel for the whole conservation period. Shut off the water supply line to the pool and make sure it does not contain water. Drain the water from the basin to a level of 1m from the top edge of the pool. In the technical compartment in the multiconductor connection box disconnect the electric motor wires. Unscrew the nut joining the pump and remove the pump from the technical part. Ensure that after draining the water from the pump, it was kept in a dry place. Turbine pump must be rotated manually 2-3 times during the winter. Upon completion of the work do not forget to close the lid of filtration equipment and lock screws. 14 - Technical Support Center If you have questions or suggestions, or need additional technical information, please contact technical support at: e-mail: info@vsv-group.com If you want to get information about other product of VSV Aqua Group, instructions for their use and installation, we invite you to visit us at INTERNET: www.vsv-group.com. COPYRIGHT VSV Aqua Group reserves the right without notice to make changes to this manual, related to the improvement of equipment, and in case of inaccuracies and typographical errors. All these changes will be incorporated into new editions of this manual. You should visit our page on the Internet: www.vsvgroup.com to obtain updated information and new developments. VSV Aqua Group has full rights to patents, patent applications, trademarks, copyrights and other intellectual property associated with the content of this guide. This manual does not give you any license or other legal rights to the use of the above without the express written permission of VSV Aqua Group. CE declaration of conformity is issued in compliance with the 89/336/EEC rule of electromagnetic compatibility and with 73/23/EEC rule of safety requirements for electric equipment. 26