GENERAL ELECTRIC VERTICAL PACKAGED UNITS

Similar documents
Concealed Ducted Split Series R-407C MBH

GENERAL ELECTRIC AIR HANDLING UNITS DIRECT EXPANSION. ABQ Series ABQ03 thru ABQ TR thru 30 TR 9 kw thru 105 kw

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Commercial High-Efficiency Condensing Units

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

PAJ3. Product Specifications

PACKAGE AIR CONDITIONER

Concealed Fan Coil Units DY18/KY018 thru DY60/KY TR thru 5 TR 5 kw thru 17.5 kw Cool & Heat pump models

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

General Description. Operation

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

MACH N-407 Heat Pump Air-Cooled Chiller

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

PAR5. Product Specifications

MAC N-407 Air-Cooled Chiller

Commercial High-Efficiency Condensing Units

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Product Data. 50ZP (60Hz) Single-Package. Air Conditioners 3-5 Nominal Tons

Product Data. 50EES--ZP (50Hz) Single Package Air Conditioners 3-5 Nominal Tons

INSTALLATION, OPERATION & MAINTENANCE MANUAL SINGLE PACKAGED ROOF TOP AIR CONDITIONERS 'PT' SERIES MODELS: PT036 - PT360

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

WJH4 Product Specifications

MAC-120HE-03 Air-Cooled Chiller

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

WCH5**4. Product Specifications

Product Data. Features/Benefits All in one package high cooling efficiency, installation convenience, ease of accessibility for timesaving

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

VertiCool Aurora Engineering Guide

Advance Release September 2009

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

R4H4. Product Specifications

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS

50TJM Nominal Cooling Capacity Tons HFC R - 410A Refrigerant

EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, Standard CFM / Ls EER

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

VariCool VAV Engineering Guide

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

Product Data. Features/Benefits. 50ZP Single-Package Electric Cooling Units. 2 to 5 Nominal Tons

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

THE WALL-MOUNT TM SIX TON AIR CONDITIONER

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

SINGLE-PACKAGE ROOFTOP HEAT PUMP UNITS INDEX. VOLTAGE (3 Ph, 60 Hz) ACCESSORIES

R4H4. Product Specifications

C13-Series Engineering Guide

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

Product Data. 50ZPB Single---Packaged Air Conditioner System With R---410A Refrigerant Single Phase 2 to 5 Nominal Tons (Sizes )

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

GENERAL ELECTRIC CONCEALED SYSTEMS

Product Data. PA4Z SINGLE -PACKAGED AIR CONDITIONER SYSTEM WITH PURONr (R -410A) REFRIGERANT SINGLE PAHSE 2 TO 5 NOMINAL TONS (SIZES )

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

GREEN REFRIGERANT R-410A

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

N4H4. Product Specifications

Product Data PA3Z- B SINGLE- PACKAGED AIR CONDITIONER SYSTEM WITH R- 410A REFRIGERANT SINGLE PHASE 2 TO 5 NOMINAL TONS (SIZES )

Product Data. Features/Benefits These dependable split systems match Carrier s indoor-air handlers and directexpansion

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

EHH SERIES DRAW THROUGH FAN COILS CFM

1. Product Lineup. 2. External Appearance. 3. Nomenclature M R C 36 H W N1 - R. Power supply R: 380~415V 3Ph~ 50Hz. Refrigerant type N1: R410A

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

Model 655A Sizes

WALL-MOUNT HEAT PUMPS - (60HZ)

Wiring Diagrams. 38ARZ ARS ARD Air-Cooled Condensing Units 50/60 Hz

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

Model PA1Z SINGLE PACKAGED AIR CONDITIONERS. Size SS-PA1Z-01 DESCRIPTION FEATURES

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

ComPac I & ComPac II 1 to 6 Ton Vertical Wall Mount Air Conditioners Models AVP

Product Data. 50ZP Single-Package Air Conditioners. 2 to 5 Tons

Product Specifications. Vertical Floor Consoles By First Co.

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

CENTRAL SPLIT UNIT UNIC

Models: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

Product Data. Features/Benefits All in one package high cooling efficiency, installation convenience, ease of accessibility allow for timesaving

Product Data. Features/Benefits. 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes. 2to4NominalTons

Transcription:

GENERAL ELECTRIC VERTICAL PACKAGED UNITS APF Series APF036 thru APF060 3 TR thru 5 TR 10 kw thru 17.5 kw GE_APF_Series.indd 1

CONTENTS Model decoding 3 Unit features 4-5 General data 6 Cooling capacities 7 Electrical data 7 Dimensions 8 Access details 9 Typical schematic wiring diagram 10-11 Continuing research results in steady improvements. Therefore, these specifications are subject to change without notice 2 GE_APF_Series.indd 2

MODEL DECODING 1, 2 &3 BASIC 4, 5 & 6 NOMINAL COOLING CAPACITY (MBH) 7 ELECTRICAL SUPPLY V-Ph-Hz 8 REFRIGE- RATION CIRCUIT 9 COMPRESSOR TYPE 10 BLOWER MOTOR 11 DRIVE OPTIONS 12 HEATER 13 COND. MOTOR 14 EVAPORATOR COIL 15 CONDENSER COIL 16 FILTER APF G E VE R T IC AL P AC K AG E D UNIT 036 048 060 L 380/415-3-5 0 (4 WIR E ) S S ING L E S S C R OL L V S T D. N DIR EC T N N O N S T D. A ALUMINU M A ALUMINU M N O HER METIC MOTOR DR IV E HE AT E R F IN F IN F ILT E R G " R R E C IP R O - C AT ING HER METIC B C OAT E D ALUMINUM F IN B C OAT E D ALUMINUM F IN N 2 P LE AT E D F ILT E R C C OP P E R F I N C C OP P E R F IN 17 UNIT ACCESSORIES N S T D. UNI T 18 APPLICA TION S N S T ANDAR D AP P LIC AT ION C C OMMUNIC A - TION S HE LT E R AP P LIC AT ION 19 OPTIONS 20 DIS- CHARGE (SUPPLY AIR) 21 ACCESS N S T D. R H F FR ON T R L L H ( ) 3 GE_APF_Series.indd 3

UNIT FEATURES A. GENERAL The wall mounted vertical packaged units from GE are designed for optimum cooling, convenience and dependability, which make them suitable for the most demanding applications such as telecom industry, beside general airconditioning applications. These self contained units have the sheet metal panels designed to provide service access for compressors and electrical controls even when two units are mounted side by side with minimal space in between. Filters and controls are accessible from the back of the unit. B. UNIT ENCLOSURE Panels are of heavy gauge, G-90 galvanized steel sheet with removable access panels, completely weatherized for outdoor installation and properly reinforced & brazed. Panels and access doors will provide easy inspection and access to all internal parts. Enclosures are provided with adequately reinforced points of support for wall mounting application. Steel sheet panels are zinc-coated and galvanized by the hot dip process of lockforming quality conforming to ASTM A 653 commercial weight G-90, followed by baked-on electrostatic polyester dry powder coat, and capable of withstanding 1500 hours in salt spray test. C. COMPRESSOR Compressors are fully hermetic type, provided with all standard controls necessary for safe operation. These are equipped with internal motor protector, factory-installed crankcase heater and rubber vibration isolators for quiet and efficient operation. Scroll compressors are installed as standard on these units. Reciprocating hermetic compressors can be available as an option. D. AIR COOLED CONDENSING SECTION 1. The air-cooled condensing section is enclosed within the unit housing and consists of condenser coil, fan, electric motor and inherently protected compressor. All condenser coils are of the enhanced fin-and-tube type and mechanically bonded to aluminum fins. As an option, corrugated copper fins or enhanced coated aluminum fins may be provided. Tube support sheets are galvanized steel, formed to provide structural strength. 2. Fans are propeller type, direct drive, with side air discharge through the condenser coil. 3. Motors are totally enclosed air-over type. Inherent thermal protection is automatic reset type. E. EVAPORATOR COIL SECTION 1. All cooling are of the enhanced fin and tube type, constructed of enhanced copper tubes and mechanically bonded to aluminum fins. As an option, corrugated copper fins or enhanced coated aluminum fins may be provided. Tube support sheets are galvanized steel, formed to provide structural strength. The refrigerant metering device is a thermostatic expansion valve. A coated galvanized steel condensate drain pan is provided. 2. Insulation Insulation is supplied in adequate thickness (1/2 ) and density to prevent condensation from forming on the unit casing. Insulation meets the requirements of NFPA 90A and is protected against deterioration and erosion from air panels. F. EVAPORATOR BLOWER ASSEMBLY. The direct drive evaporator blowers are of the centrifugal forward curved design. The twin blower wheels are constructed of steel, and they are statically and dynamically balanced for quiet and smooth performance. Motors are permanent split capacitor type with tapped speed windings to suit various air delivery requirements corresponding to each model. The bearings are of sleeve type. G. FILTERS Two inch Pleated high efficiency filters are provided as standard. 4 GE_APF_Series.indd 4

UNIT FEATURES H. ELECTRICAL CONTROLS 1. For normal air-conditioning applications TM This packaged unit control consists of Systemizer Microprocessor Based Electronic Control Board, incorporating the following features (a) Compressor Lockout. If any of the unit s safety controls trips due to abnormal conditions the Electronic Controls lockout the compressor, preventing restart, unless attended by service personnel. The unit can be re-started only by reset of thermostat a er ensuring safe system conditions. (b) Anti recycle timer for compressor safety in case of accidental manual reset or immediate recycling of thermostat due to load demand. (c) Indicator LED lights Green Power ON. Red Fault indication. (d) Typical single stage thermostats to be ordered (part number 800-646-91). 2. For communication shelter applications (To be ordered separately) The set of two APF units (when used for communication shelter applications) is provided with a dedicated control with the following features (a) Auto-reset High Pressure Switch Built in lockout circuit with auto reset. Provides protection to the compressor. (b) Auto reset Low Pressure Switch Built in lockout circuit and low-pressure timed bypass circuit. (c) Microprocessor based electronic board provides the compressor lockout, if any of the unit safety controls trip due toabnormal conditions. (d) Auto lead/lag controller The Auto lead/lag controller is a complete control package designed to operate a fully or partially redundant air conditioning system having two units paired together. It consists of a thermostat and solid state timer with selectable changeover intervals (typical 7 days). This control unit is factory-wired, tested and mounted in separate enclosure for quick installation inside the air-conditioned space. (e) Low ambient control By using automatic condenser fan speed controls. I. OUTSIDE AIR OPTIONS Fresh air Inlet with manual damper can be provided as an option for adding up to 25% fresh air as required. 5 GE_APF_Series.indd 5

GENERAL DATA MODEL NUMBER APF036 APF048 APF060 NOMINAL C AP AC IT Y (TONS ) 3 4 5 COMPRESSOR Power supply (V-Ph-Hz) 380/415-3-50 T ype S croll Quantity 1 1 1 Oil (oz) 42 66 60 R efrigerant R -22 Operating C harge (oz) 115 148 159 CONDENSER FAN Power supply (V-Ph-Hz) 220/240-1-50 T ype P ropeller Quantity Diameter (inch) 1 18 1 24 1 24 Nominal CFM 1900 2750 2500 Motor HP R P M 1/4 900 1/3 950 1/3 950 CONDENSER COIL T ype Corrugated Fin and Tube Tube dia. - Rows - Fins per inc h 3/8-3-1 6 3/8-3-16 3/8-4-16 T otal face area (S q. ft.) 6.4 8 8 EVAPORATOR BLOWER T ype C entrifugal S ize (inch) 7 x 9.5 (2 Nos.) 8 x 8.5 (2 Nos.) 8 x 8.5 (2 Nos.) Drive type Direct drive Nominal airflow, CFM 1200 1600 1800 Motor watts 450 600 650 EVAPORATOR COIL T ype Corrugated Fin and Tube Tube dia. - Rows - Fins per inc h 3/8-4-14 3/8-4-14 3/8-4-14 T otal face area (S q. ft.) 3.4 5 5 R E T UR N AIR F ILT E R S Quantity 1 1 1 S ize (inch) 30 x 22 x 2 36 x 22 x 2 36 x 22 x 2 WEIGH T K gs. 190 255 267 6 GE_APF_Series.indd 6

COOLING CAPACITIES / MODEL NO. APF036, APF048 & APF060 CONDENSER ENTERING AIR TEMP. ( 0 F) TC 85 SC kw TC 95 SC kw TC 105 SC kw TC 115 SC kw TC 125 SC kw APF036 APF048 APF060 EVAPORATOR AIRFLOW, CFM/DR 1200/0.038 1600/0.059 1800/0.067 EVAPORATOR ENTERING AIR, WBE ( 0 F) 62 67 72 62 67 72 62 67 72 33.5 36.1 39. 2 46.9 52.1 57. 1 57.3 62.3 67. 7 30.1 27.2 25. 9 45.6 37.8 29. 7 53.5 44.1 34. 5 3.54 3.95 4.12 4.94 5.12 5.32 5.64 5.89 6.12 32.3 34.8 37. 0 44.8 49.0 54. 1 54.6 60.0 64. 6 29.0 26.4 25. 3 43.6 36.8 28. 8 52.0 43.0 33. 5 4. 1 4.1 8 4.3 6 5.1 7 5.3 8 5.6 1 6.0 1 6.2 9 6.54 32.0 33.2 35. 3 42.2 46.5 51. 1 51.9 56.4 61. 4 27.1 25.5 24. 2 41.1 35.8 27. 8 49.4 42.0 32. 5 4.14 4.56 4. 6 5.4 0 5.6 4 5.8 7 6.4 2 6.7 3 7.02 30.8 32.8 33. 7 39.6 43.7 48. 1 49.1 53.4 58. 1 26.5 24.3 23. 7 38.5 34.8 26. 9 46.8 40.9 31. 5 4.65 5.1 5.19 5.61 5.86 6.13 6.87 7.22 7.55 28.9 29.0 31. 8 36.9 40.7 45. 0 46.2 50.2 54. 7 24.2 22.7 20. 7 35.8 33.7 25. 9 44.0 39.8 30. 5 5.39 5.66 5.49 5.80 6.08 6.35 7.36 7.76 8.14 TC Total Capacity (1000 Btuh) Gross SC Sensible Heat Capacity (1000 Btuh) Gross DBE Dry Bulb Temp. ( 0 F) of Air Entering Coil WBE Wet Bulb Temp. ( 0 F) of Air Entering Coil DBL Dry Bulb Temp. ( 0 F) of Air Leaving Coil WBL Wet Bulb Temp. ( 0 F) of Air Leaving Coil kw Total unit power input DR Wet Bulb depression ratio NOTES 1. Direct interpolation is permissible Do not extrapolate. 2. Capacities above are based on DBE = 80 0 F. For higher or lower DBE, add following correction factor to sensible capacity = 1.08 x CFM (1 DR) (DBE 80). 3. To calculate leaving conditions, follow this procedure DBL = DBE (Sensible Capacity (Btuh) / 1.08 x CFM); WBL = DBL [DR (DBE WBE)]. 4. Above data is based on scroll compressors. For hermetic reciprocating compressors, multiply capacity by 0.97 and power input by 1.06. ELECTRICAL DATA MODEL No. APF036 POWER SUPPLY (V-Ph-Hz) VOLTAGE RANGE COMPRESSOR * FAN * BLOWER MOTOR MOTOR FLA FLA MIN. MAX. RLA LRA MCA MOCP 380/415-3-50 342 462 7.1 46 1.9 3.6 14. 4 20 MODEL No. APF048 POWER SUPPLY (V-Ph-Hz) VOLTAGE RANGE COMPRESSOR * FAN * BLOWER MOTOR MOTOR FLA FLA MIN. MAX. RLA LRA MCA MOCP 380/415-3-50 342 462 10 65.5 2.1 4.1 18. 7 25 MODEL No. APF060 POWER SUPPLY (V-Ph-Hz) VOLTAGE RANGE COMPRESSOR * FAN * BLOWER MOTOR MOTOR FLA FLA MIN. MAX. RLA LRA MCA MOCP 380/415-3-50 342 462 10 74 2.1 4.1 18. 7 25 LEGEND FLA Full Load Amps RLA Rated Load Amps LRA Locked Rotor Amps MOCP Maximum Over Current Protection MCA Minimum Circuit Amps * Single phase motors 7 GE_APF_Series.indd 7

DIMENSIONS / APF036 - APF060 B C TOP VIEW 610 [24] EVAPORATOR COIL SUPPLY AIR OPENING F RETURN AIR OPENING MOUNTING FLANGE FILTER CONTROL BOX I E G SUPPLY AIR RETURN AIR A H 51 [2] D FRONT VIEW CONDENSER COIL END VIEW COND. AIR INLET MODEL NUMBER A DIMENSIONS B C D E F G H I APF036 2000 (78.7) 980 (38.6) 920 (36.2) 908 (35.8) 457 (18) 762 (30) 203 (8 ) 762 (30) 350 (13.8) APF048 2134 (84) 1143 (45) 1067 (42) 662 (26.1) 762 (30) 767 (30.2) 251 (9.9) 759 (29.9) 403 (15.9) APF060 2134 (84) 1143 (45) 1067 (42) 662 (26.1) 762 (30) 767 (30.2) 251 (9.9) 759 (29.9) 403 (15.9) NOTES 1. All dimensions are in millimeters, (dimensions in brackets are in inches). 2. Service clearance should be 915 mm (3 feet) on all sides (other than the front supply & return air opening side). 8 GE_APF_Series.indd 8

ACCESS DETAILS / APF036 - APF060 FILTER & ELE. CONTROLS (FROM BACK SIDE) FILTER & ELE. CONTROLS (FROM BACK SIDE) COMPRESSOR ACCESS (FROM SIDE) COMPRESSOR ACCESS (FROM SIDE) LEFT SIDE ACCESS RIGHT SIDE ACCESS 9 GE_APF_Series.indd 9

TYPICAL SCHEMATIC WIRING DIAGRAM (FOR NORMAL AIR-CONDITIONING APPLICATIONS) NTB HVTB LUG SET POINTS CRANKCASE HEATER CONNECTION LEGEND BM BLOWER MOTOR BMC BLOWER MOTOR CONTACTOR CAP CAPACITOR CC COMPRESSOR CONTACTOR CB CIRCUIT BREAKER C. HTR CRANKCASE HEATER COMP/C COMPRESSO R FM FAN MOTOR (CONDENSER) FCS FAN CYCLING SWITCH HPS HIGH PRESSURE SWITCH HVTB HIGH VOLTAGE TERMINAL BLOCK L1 LINE 1 L2 LINE 2 L3 LINE 3 LP S L OW PRESSURE SWITCH LUG LUG GROUND LVTB LOW VOLTAGE TERMINAL BLOCK NTB NEUTRAL TERMINAL BLOCK SM SYSTEMIZE R TRANS TRANSFORMER _ FIELD WIRIN G + DISCONNECT TAB - 1/4" SPLICE-CLOSED END TERMINAL BLOCK OR TERMINATION POIN T NOTES 1. POWER SUPPLY, 380/415V-3Ph-50Hz. THERMOSTAT CONTROL VOLTAGE - 24VAC. 2. ANY WIRE REPLACEMENT SHOULD BE OF THE 90 0 C OR ITS EQUIVALENT. USE COPPER CONDUCTOR WIRES ONLY. 3. POWER MUST BE SUPPLIED TO CRANKCASE HEATER FOR MINIMUM OF 12 HOURS PRIOR TO SYSTEM STAR T UP. IF POWER IS OFF 6 HOURS OR MORE, CRANKCASE HEATER MUST BE ON FOR 12 HOURS BEFORE OPER- ATING THE SYSTEM. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RE- SULT IN COMPRESSOR DAMAGE. 4. USE ELECTRONIC THERMOSTAT ONLY. A 3 TO 4 MINUTE (APPROX.) BUILT-IN SHORT CYCLE PROTEC- TION FOR COMPRESSOR IS AVAILABLE IN GE ELEC- TRONIC THERMOSTAT. 5. FUSED DISCONNECT SWITCH OR CIRCUIT BREAKER TO BE PROVIDED BY CONSUMER WITH RATING AS RECOMMENDED BY GE. 6. COMPRESSOR IS PROVIDED WITH INTERNAL OVERLOAD. 7. USE DISCONNECT TAB + OR SPLICE ONLY WHER E EVER REQUIRED FOR EXTENSION OF ORIGINAL WIRE. 8. FOR ANY SAFETY TRIP OF COMP. (FAULT), VOLTAG E ACROSS TERMINAL 1 & X OF SYSTEMIZER IS 24 VAC. ALSO COMPRESSOR LOCKOUT LIGHT IS ON. 9. FREE END OF MOTOR LEADS TO BE CAPPED WITH CRIMPABLE WIRE NUT. 10.S M HAS 3 TO 5 MINUTE PROVISION FOR C OMPRESSO R ANTI-RECYCLING TIMER. MODEL APF036 APF048 APF06 0 FACTORY INSTALLE D BM SPEED (WIRE COLOR) OR N B LU BLK 10 GE_APF_Series.indd 10

TYPICAL SCHEMATIC WIRING DIAGRAM (FOR COMMUNICATION SHELTER APPLICATIONS) NTB LEGEND HVTB LUG SET POINTS AT B A UXILIARY TERMINAL BLOCK BM BLOWER MOTOR BMC BLOWER MOTOR CONTACTOR CAP CAPACITOR CC COMPRESSOR CONTACTOR C. HTR CRANKCASE HEATER COMP/C COMPRESSO R FM FAN MOTOR (CONDENSER) FCS FAN CYCLING SWITCH HPS HIGH PRESSURE SWITCH HVTB HIGH VOLTAGE TERMINAL BLOCK L1 LINE 1 L2 LINE 2 L3 LINE 3 LP S L OW PRESSURE SWITCH LUG LUG GROUND NTB NEUTRAL TERMINAL BLOCK _ FIELD WIRIN G + DISCONNECT TAB - 1/4" SPLICE-CLOSED END TERMINAL BLOCK OR TERMINATION POIN T CRANKCASE HEATER CONNECTION NOTES * CONTROLLER TERMINAL S ATB LH S UNI T 1. POWER SUPPLY, 380/415V-3Ph-50Hz. THERMOSTAT CONTROL VOLTAGE - 24VAC. 2. ANY WIRE REPLACEMENT SHOULD BE OF THE 90 0 C OR ITS EQUIVALENT. USE COPPER CONDUCTOR WIRES ONLY. 3. POWER MUST BE SUPPLIED TO CRANKCASE HEATER FOR MINIMUM OF 12 HOURS PRIOR TO SYSTEM STAR T UP. IF POWER IS OFF 6 HOURS OR MORE, CRANKCASE HEATER MUST BE ON FOR 12 HOURS BEFORE OPER- ATING THE SYSTEM. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RE- SULT IN COMPRESSOR DAMAGE. 4. FUSED DISCONNECT SWITCH OR CIRCUIT BREAKER TO BE PROVIDED BY CONSUMER WITH RATING AS RECOMMENDED BY GE. 5. COMPRESSOR IS PROVIDED WITH INTERNAL OVERLOAD. 6. USE DISCONNECT TAB + OR SPLICE ONLY WHER E EVER R EQUIRED FOR EXTENSION OF ORIGINAL WIRE. 7. FREE END OF MOTOR LEADS TO BE CAPPED WITH CRIMPABLE WIRE NUT. MODEL APF036 APF048 APF060 * CONTROLLER TERMINAL S ATB RHS UNI T FACTORY INSTALLE D BM SPEED (WIRE COLOR) * CONTROLLER SETUP IS FOR 2 UNITS. OR N B LU BLK 11 GE_APF_Series.indd 11

Middle East Air Conditioners Co. Ltd. Middle East Air Conditioners Co. Ltd. P.O. Box 14346 Dammam 31424 KSA Kingdom of Saudi Arabia Tel +966 3 847 2688 Fax +966 3 847 2931 GE_APF_Series.indd 12 3/26/12 245 PM