Original instructions. SIRe Basic Fan Heaters Electric With quick guide. SIReBX. For wiring diagram, please see last pages.

Similar documents
SIRe Basic Air Curtains Electric With quick guide. SIReB. For wiring diagram, please see p Original instructions

Original instructions. SIRe Basic Quick guide. SIReB

SIRe Advanced Air Curtains Electric With quick guide. SIReAA GB DE FR For wiring diagram, please see last pages. ES

SIRe Competent Air Curtains Water With quick guide. SIReAC. For wiring diagram, please see p Original instructions

SIRe Advanced Air Curtains Water Ambient, no heat

AC25. Art.nr:

User's Guide. CTS6000 control panel

Quickheat 30 weather compensated boiler control

SIRe Control system. Intelligent Automatically adapts to your entrance. Proactive Anticipates for quicker reactions. Adaptive Expert on your entrance

Great Britain en. Installation, user and service manual. Control panel HMI Gas 310/610 ECO PRO

Original instructions PA2500

Operating Instructions

Dryer Controller M720

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

50110_HM-neoStat-2014_Layout 1 31/10/ :33 Page 1 neo

Roth Touchline. German quality since Quick and easy user manual 1/10

12V. Model: Available in : Sapphire Black and Glacier White. 2 Series

Cylinder Ironers. Operating Supplement. 320 mm Diameter, OPL Insertion width 1664 mm, 2080 mm Refer to Page 5 for Model Identification

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

USER MANUAL Comfort System4 TM

Original instructions. Thermoplus PL RU

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

ProCon 16, 31, 47, 75, 77 & HT. RVA 46. Zone Controller Commissioning Data.

EasyStart Select. Visit for more technical information and downloads. Eberspächer parking heaters

Model: Slimline-N. 1 Slimline Series

Model: 1 Series 12V. Available in: Sapphire Black and Glacier White

Original instructions SFS

Model: Available in: Sapphire Black and Glacier White. 1 Series

DC 60 & DM 60 displays

TERMO-Blok TERMO-Extra TERMO-Blok PTV

Operating Instructions

Model: Available in : Sapphire Black and Glacier White. 1 Series

OT-FX2 OLED TOUCH for the FX II Touch control panel OPERATOR S MANUAL. Technicold Marine Systems

Drying Cabinet Installation and Operating Manual

User Manual. Dryer Controller M720

Air Comfort. Installation instructions (English) A

5 On/Off button 6 Function selector switch 7 Symbol - Eco function 8 Symbol - Standard heating function

Model: Edge-HC. 1 edge-hc

Generator Control Unit, GCU 100 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list

Original instructions AR

Operating instructions Control MIKE 3 - CE for MEIKO dishwashers

DPC-1 Programmable digital thermostat with communication Versión 2.0. Technical Information. Ref: N

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

Operating Instructions Model: PRT-RP Version 3. 05/11 Revision 2 Ref: PRTRP

O CRC100. Comfort Room Controller (2015/01) en

1500W Black Glass Portable Electric Panel Heater KAHTP20BLKA

Operating instructions. For the operator. Operating instructions VRT 350. Room temperature-controlled controller GB, IE

DEIF A/S. Description of options. Option A4, Loss of mains protection package Automatic Gen-set Controller. Description of option

Service manual. Type: TD25. Contents

Engine Control Unit, ECU 100 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list

User Manual for Induction Heater INCOIL model IH series

ECO AND DATE /06 ARTWORK DESCRIPTION. 22 page A6 : Saddle stitch (2-wire) 6 page : 4 colour : 170gsm Silk 18 page : 1 colour : 100gsm Silk

ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data.

Mounting and Operating Instructions EB 5610 EN. TROVIS 5600 Automation System TROVIS 5610 Heating and District Heating Controller

AIR HEATING UNIT HEATMASTER ACJB INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS

Compact Genset Controller, CGC 400 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list

Operating principle. Bolero XL (2008)

The guarantee on this appliance is valid for 12 months from the first day of installation.

E-COMBI EVO E-SYSTEM EVO

Original instructions AR

Operating principle. Quinto

Installation and maintenance instructions for cabin units type vertical IDAC (V50)

R. Room temperature controller with solar control FR 120. Operating instructions for the user (2012/02)

Operating Instructions Heating Controllers RVL479, RVL480, RVL481, RVL482

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)

Model: Touch-RS. 1 Touch-RS

ivector HEATER/COOLER 2 AND 4-PIPE MODELS.

U ser's Guide PC6010

Instructions for Use

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert)

Local Air Conditioner

ST9400S User Guide. 1 Day Programmer, 2 channel With Boiler Service Reminder / Shut-down Feature

SUPERINTEND VRE-08/16/32/64

1.1 Controller General Information

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions

C37. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C37. User's Guide. Installer's Guide *VI7CE602* *087R8070* *087R8070* *VI7CE602*

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

REPAIR INSTRUCTIONS. TUMBLE DRYER Vented WTA34.. / WTA35..

Digital Marine Exhaust Temperature Alarm

RADIANT HEATING AND COOLING SYSTEMS CLIMATE CŎNTROL ZONING SYSTEM INSTALLATION GUIDE. Climate Cŏntrol Zoning System Installation Guide

OSA 3. Level alarm for oil separator. Afriso Ema AB. Kilvägen 2 SE Arlöv Sweden T +46-(0) F +46-(0)

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

SAVE VTC 700. Heat Recovery Ventilation Unit

OPERATING INSTRUCTIONS. Drying cabinet DC 7774 DC Read the instructions before using the machine.

ir-range 8G /03.15 Changes reserved.

User Manual RBS 24. for model CE series ENERGY. Wall mounted instantaneous combi boiler room sealed chamber

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

Installer manual ELK 213 Immersion heater

TDS 20 R / TDS 30 R / TDS 50 R

HOT 4000 USER MANUAL. Version 2.1. This manual shall be read in its entirety before using the machine.

Local air conditioner

USERS MANUAL FOR GAS BOILERS

Installation and Operating Manual

Operating Instructions Model: PRT/HW - PRT/HW-N Version 3. 09/09 Revision 2 Ref: PRT/HW/NV3

1 User Manual for Induction Heater INCOIL model IH series

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

Control of the system, MLP RO pump station

DOMESTIC HOT WATER Follow operational sequence

User Manual THR842DUK Wireless Digital Thermostat

Transcription:

Original instructions SIRe Basic Fan Heaters Electric With quick guide SIReBX C For wiring diagram, please see last pages.

Quick guide/start up Check that all constituent parts are present (see section Constituent parts). Advice about location Control unit SIReUB1 has an integrated room temperature sensor and is installed so that it is easily accessible to the user. PC Board base SIReB1X is installed close to the unit. Wiring between the PC Board Base SIReB1X and heating fan must be laid for 230V. RJ12 (6p/6c) modular cables, which are available in different lengths, are used to connect the PC board and the control unit. Longer cables are available as options. Maximum cable lengths see section Options. To prevent unauthorised people from accessing the Control unit it can instead be placed in another area and an external room sensor, SIReRTX (option), can be installed in the premises to sense the correct temperature. Note! Internal sensor SIReIT02 shall be mounted in the fan exhaust in the fan heater unit in intended holder. Enter ID/Operation without control unit The control system can control one or more units in parallel (max 9). Each unit must get a unique ID number (1-9) which is set in the ID selector of the PC board. E.g. Unit 1: ID=1, unit 2: ID=3 If the external control for some reason has not been installed the unit can still be run temporarily. The ID selector is then set to mode 0 see the image below. The function is half speed and half heating output When the ID number must be changed the unit must be disconnected from power. 2 1 0 3 4 5 Each unit should have a unique ID on its SIReB1X card. 6 7 2 8 1 9 0 3 4 5 To run the unit temporarily without external control select mode 0. 6 7 8 9 Connect the system In PC board Base SIReB1X the unit is connected further with RJ12 (6p/6c) modular cable if several units are to be connected in parallel. If an external room temperature sensor SIReRTX is used it is connected using modular cable RJ11 (4p/4c) on SIReB1X. PC board Base SIReB1X in/at the unit and control unit SIReUB1 is connected with RJ12 (6p/6c)modular cable after the other units are powered up. Power supply for electric heat must be connected separately (check manual for the fan heater unit). Wiring diagrams The wiring diagrams are in a separate section at the end of this manual. 11

Start up System supplied with power. Three digits 1.4.0. (software version) is quickly shown in th the status window followed by three horizontal lines. After about 30 seconds the prevailing room temperature is then shown in the status window. After the first start up the following basic settings are made. Use arrow up/down and set the desired room temperature, fan speed step and heating step. To change a setting push the round button (confirm), the setting will start to flash and can be adjusted by using the arrow up/down. Factory settings gives manual control of fan and heating controlled by thermostat. For more setting alternatives see section Operating modes. At the first start up alarm and error codes can occur, these can usually be reset without action. Fansteps Heatsteps SE06-15 4 2 SE20 2 2 SE30 2 3 Choose desired room temperature 5 - +30 C C 20 Choose fan step 1-5 (alt. 1-3) - 3 Activate heat 0 = No heat 1 = Heat step 1 possible 2 = Heat step 2 possible (3 = Heat step 3 possible) Heat steps controlled by thermostat _ 2 12

Contents Quick guide/start up Advice about location 11 Connect the system 11 Wiring diagrams 11 Enter ID/Operation without control unit 11 Start up 12 Constituent parts SIReBX 14 Option 15 Max. cable lenghts 15 Operating modes Operating modes 16 Fan over run 16 Heat regulation 16 Set values 16 System on/off 16 Control unit SIReUB1 Overview 17 Explanations 17 Installer menu Parameter menu 18 Parameter description 18 Alarm and error codes Overheat protection 19 Displaying alarm and error codes 19 Reset alarm 19 Wiring diagrams, see last pages 13

C Constituent parts SIReBX SIReUB1, control unit Basic Wall unit cover SIReB1X, External PC board Basic SIReIT02, internal temperature sensor 2 m SIReCC, modular cables Dimensions constituent parts Type Description HxWxD [mm] L [m] SIReUB1 Control unit 120x70x35 SIRB1X PC Board Base SIReIT02 Internal sensor 2 SIReCC605 Modular cable RJ12 (6/6) 5 14

Option SIReRTX, external room temperature sensor SIReCJ4, joint piece SIReCJ6, joint piece SIReCC, modular cable Type RSK-no. E-no. Description HxWxD L [m] SIReRTX 673 09 22 87 510 12 External room temperature sensor 70x33x23 SIReCJ4 Joint piece for two pcs. RJ11 (4/4) SIReCJ6 Joint piece for two pcs. RJ12 (6/6) SIReCC603 673 09 23 87 510 13 Modular cable RJ12 (6/6) 3 SIReCC605 673 09 24 87 510 14 Modular cable RJ12 (6/6) 5 SIReCC610 673 09 25 87 510 15 Modular cable RJ12 (6/6) 10 SIReCC615 673 09 26 87 510 16 Modular cable RJ12 (6/6) 15 SIReCC403 673 09 27 87 510 17 Modular cable RJ11 (4/4) 3 SIReCC405 673 09 28 87 510 18 Modular cable RJ11 (4/4) 5 SIReCC410 673 09 29 87 510 19 Modular cable RJ11 (4/4) 10 SIReCC415 673 09 30 87 510 20 Modular cable RJ11 (4/4) 15 Max. cable lenghts Modular cabel RJ12 (6p/6c) between SIReUB1 and SIReB1(X): max 50 m. Modular cabel RJ12 (6p/6c) between two SIReB1(X): max 50 m. Modular cabel RJ11 (4p/4c) to room sensor SIReRTX: max 20 m. Total cable lenght is permitted in the system is a maximum of 300 m. 15

Operating modes Operating modes Factory settings gives manual control of fan and heating controlled by thermostat at choosen step. Auto mode Fansteps SE06-15 4 2 SE20 2 2 SE30 2 3 Heatsteps Change parameter P04 from 0 to 1 (see list of parameters on next page) to active auto mode. Thermostat controls both fan and heating Set values Use arrow up /down to choose desired room temperature, fan speed step and heating step. Push the confirm button and the digit(s) starts to flash. The value can now be adjusted using the arrow up /down, and confirm. C Manual mode Decrease the temperature setting below 5 C and the following symbols are shown in the status window = manual mode. In manual mode both fan- and heating steps are controlled manually. Temperature Fan speed step 20-3 Heating step _ 2 Fan over run When heat has been activated the fan will continue to run to cool down the unit. The over run time is 180 seconds or shorter if the internal temperature has dropped below +30 C (only valid for units with internal temperature sensor). Heat regulation When the room temperature drops below the set point temperature the first heating step is activated. If temperature continues to drop, another heating step is activated (see description below parameters P.00). System on/off Press the ON /OFF button for 2 seconds to switch off the system. The unit s safety functions are still active when the system is switched off, which means that the fan can continue to run for a moment after mode OFF has been selected. 16

Control unit SIReUB1 Overview Arrow up Scroll up Arrow down Scroll down C Statuswindow Confirm C Prevailing room temperature 208. Desired room temperature 20 ON/OFF button Alarm Red led Run signal Green led Fan speed step - 3 Heating step _ 2 Explanations Status window The status window has four main displays: prevailing and desired room temperature, fan and heating setps. Alarm codes and parameter settings can also be shown in the status window. Confirm To have access to the Installers menu, choose parameters and cofirm an adjusted setting. After about 20 seconds the control unit goes back to displaying the prevailing temperature. Arrow up Scroll up in menu / increase a setting. Arrow down Scroll down in menu / deacrease a setting. 17

Installer menu Parameter menu Keep Confirm button pressed until P00 is shown in the status window. Use arrow up / down to scroll between the parameters. Press Confirm button once to change a setting in the parameter menu. Flashing values can be adjusted using the arrow up/down and then confirm. Keep the Confirm button pressed to return to the status window. (Returning automatically to the status window after about 50 seconds). P00. P01. P02. P02.. Parameter description P13. P.00 Temperature difference heating steps Sets the difference between the heating steps. Factory setting of 1,0 and a desired room temperature of 20 C gives the following operation:low heating step is connected at +19,5 C (disconnected at +20,0 C). If temperature continue to drop below +18,5 C another heating step is connected (disconnected at +19,0 C), etc. P.01 Overheating alarm ON/OFF Possibility to block the alarm (only valdid for units with internal temperature sensor). P.02 Over run time Time when the fan continue to run when the heat has been activated (only valid for units with internal temperature sensor). P.03 Temperature limit for over run Over run time is cancelled if the internal temperature drops below this set value (only valid for units with internal temperature sensor). P.04 Fan control Choose manul (0) or auto (1) mode, read more under section Operating mode. P.05 Internal temperature Prevailing internal temperature. Only the peak value is shown when several units are connected (only valid for units with internal temperature sensor). P.06 - P.13 Run time Run time for fan and heating steps. List of parameters Parameternumber Description Setting range Factory setting P.00 Temperature difference between heating steps 0,5-10 1.0 C P.01 Overheting alarma ON/OFF ON=1; OFF=0 1/0 1 P.02 Over run time when heat has been activated 10-300 180 seconds P.03 Temperature limit for fan over run 10-40 30 C P.04 Fan control: Manul rorauto; 0=Manul, 1 = Auto 0/1 0 P.05 Display of unit internal/outlet temperature 0-100 P.06 Run time fan step 1 0-99999 P.07 Run time fan step 2 0-99999 P.08 Run time fan step 3 0-99999 P.09 Run time fan step 4 0-99999 P.10 Run time fan step 5 0-99999 P.11 Run time heating step 1 0-99999 P.12 Run time heating step 2 0-99999 P.13 Run time heating step 1+2 0-99999 18

Alarm and error codes Overheat protection SE06-15: The over heating protection is intended to restrict the exhaust temperature to 70 C. At 70 C an output step is tripped off. If the temperature continues to rise all output is interrupted at 75 C. If the temperature continues to rise despite this, for example because of a faulty contactor, the fan will start to spin at 70 C to keep the temperature down. At the same time there is an over heating alarm, see Table - Alarm. At internal temperatures of +80 C the fan runs at maximum speed. If the unit cools the output is engaged again. The alarm remains in the control unit s display. If the unit overheats twice within an hour, the alarm must be reset before the heating can be engaged again, the fan operates until the alarm is reset. SE20-30: The over heating protection is intended to restrict the exhaust temperature to 85 C. At 85 C an output step is tripped off. If the temperature continues to rise all output is interrupted at 90 C. If the temperature continues to rise despite this, for example because of a faulty contactor, the fan will start to spin at 85 C to keep the temperature down. At the same time there is an over heating alarm, see Table - Alarm. At internal temperatures of 95 C the fan runs at maximum speed. If the unit cools the output is engaged again. The alarm remains in the control unit s display. If the unit overheats twice within an hour, the alarm must be reset before the heating can be engaged again, the fan operates until the alarm is reset. Note! In event of repeated alarms and over heating alarms, carry out a thorough check and if the fault cause cannot be found contact authorised service personnel or Frico. status window. Alarm error codes see Table - next page. The status window alternate the display of the alarm/error code and faulty unit ID causing the problem. Aot. U02. Reset alarm Note! Before resetting, check that the fault is rectified and there is nothing to prevent the unit from being recommissioned! When the fault is rectifed, the alarm is reset according to description below. If "wrong" button is pressed the alarm display disappears but returns in status window after about 20 seconds. At the first start up alarm and error codes can occur, these can usually be reset without action. Alarm code starts to flash 3 sek Ert. res. Displaying alarm and error codes In event of alarm or error the alarm/error code and the unit it applies to is shown in the 19

Table - Alarm Alarm Cause Action A.FA Motor alarm Thermal switch has deployed. One or several motors have overheated. (Only units with withdrawn thermal switches.) A.ot Over heating alarm The temperature in the unit has exceeded the alarm limit for overheating. (Only applies to units with internal unit temperature.) Check that nothing is obstructing the unit s air intake and exhaust. When the overheated motor has cooled the thermal switch shuts again and the alarm can be reset. At repeated alarms, check the motors, replace damaged motors. Check that nothing is obstructing the unit s air intake and exhaust, the function of the internal temperature sensor. Table - Error codes Error code Cause Action E.co Communication SIReB1X has no contact with SIReUB1. Check connection between the SIReB1X and SIReUB1. Replace any modular cables. PC board SIReB1X has no ID = 0 Interrupt the power supply and select different ID numbers for all SIReB1X in the system. Two or more SIReB1X have the same ID-number. One or more SIReB1X do not have programs. E.cF ID Error Two or more SIReB1X in the system have different programs. Interrupt the power supply and select different ID numbers for all SIReB1X in the system. Contact Frico for support. Contact Frico for support. E.rt E.It E.ru Room sensor error Internal sensor error Room sensor error Error in or missing external room sensor SIReRTX connected to SIReB1X. Fault on or missing internal sensor in the unit (applies to units with internal sensor). Fault on internal room sensor in the control unit SIReUB1. Always disconnect the power supply when connecting or disconnecting sensors. Check connection of the sensor. Check connection of the sensor. If there is no sensor, contact Frico for support. Check connections between SIReUB1 and SIReB1X. Replace any modular cables. Check if an external sensor SIReRTX is working. If the error is not rectified the SIReUB1 must be replaced. 20

Connections between SIReB1X and Panther SE06, SE09, SE12 and SE15. L L~ N SIReB1X SE06-15 40

Connections between SIReB1X and Panther SE20 L L~ N SIReB1X SE20 41

Connections between SIReB1X and Panther SE30 L L~ N SIReB1X SE30 42

SIReB1X Pot. Unit ID C2 X5 C1 X4 ROOM X3 N L PE PE N L SIReRTX (optional) SIReUB1 C Wiring diagrams Basic 230V~ 43

Wiring diagram Basic parallel SIReB1X Pot. Unit ID Pot. Unit ID SIReRTX SIReB1 Pot. Unit ID C2 X5 C1 X4 ROOM X3 ACTUATOR SUPPLY N L~ L PE N L SIReUB1 C SIReB1 Pot. Unit ID C2 X5 C1 X4 ROOM X3 ACTUATOR SUPPLY N L~ L PE N L 44