A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1

Similar documents
Oil burners fuel unit with solenoid valve

Oil burners fuel unit with solenoid valve

Universal fuel unit for oil burners

INSTRUCTION MANUAL FOR OIL BURNER MODELS

INSTRUCTION MANUAL FOR OIL BURNER MODELS

INSTRUCTION MANUAL FOR OIL BURNER MODELS

215 Gallon Waste Oil Tank With Bypass Regulator Installation Instructions

568X, 587X, 588X Series

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Instructions for Installation, Operation, Care and Maintenance

SuperKlean Washdown Products

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Climate Control System

INSTALLATION & OPERATING INSTRUCTIONS

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Light oil burners. One stage operation

Installation & Maintenance Manual

THE THOMPSON MODEL A STEAMER NEW UNIT ASSEMBLY INSTRUCTIONS

Service Step by Step Trouble-Shooting Check-List

Single stage operation oil burner

OPERATOR S MANUAL SF-12 AND SF12A HI VOLUME WATER HEATER

APPLICATION GUIDELINES FOR COPELAND COMPLIANT SCROLL COMPRESSORS (ZR*1 Models)

1998 Expedition/Navigator Workshop Manual

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

Light oil - kerosene burner

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

Series 1140 and 1141 Temperature Regulators

Installation Instructions

V SERIES HDR GAS RANGES

Parts Available from

Dosing system. Commissioning and maintenance manual eco-pen300

INSTALLATION INSTRUCTIONS

569, 570, 571, 572 Series

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S12 S16

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

Model 601CRD Oil Burner

TECHNICAL DATA. Wet 26a. February 22, 2009

PBG PACKAGED GAS BURNER

HEATLESS DESICCANT AIR DRYER INSTRUCTION & MAINTENANCE MANUAL

OPERATING AND MAINTENANCE MANUAL FOR INSTANTANEOUS STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL F

RL 28/2-38/2-50/2 Low - High Operation

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction MOL1650 T3N 323 2FH.

SERVICE PROCEDURE FOR RETROFITTED A/C SYSTEMS

RL 70/2-100/2-130/2 Low - High Operation

FIREPLACE INSTALLATION

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

569, 570, 571, 572 Series

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction B 30 A

CRN A-F-G-E-HQQE 3x400D 50 HZ

Installation Instructions for P/N: Algas-SDI thermostat retrofit kit

Power Washer Maintenance

15 20 kw kw kw

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual

INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw

CRN90-1 A-F-G-V-HQQV 3x400D 50 HZ

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

MODEL CMA-180UC PARTS MANUAL Rev 1.18

Venco 75mm (3 ) Standard and De-airing Pugmill

ST 40 Oil Burner. Installation & Maintenance Manual

LP30 High Integrity Low Level Alarm Probe Installation and Maintenance Instructions

Single stage operation oil burner

Light oil / kerosene burner

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

TK-1001, 1101, 1201, 1301, 1601

SELF-PRIMING JET PUMPS

CR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ

HEATING AND AIR CONDITIONING

Single stage operation oil burners

Instruction Manual - Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity

A B A B4

INSTALLATION INSTRUCTIONS

SECTION air supply system + WARNING: + NOTE: GENERAL DESCRIPTION COMPRESSED AIR RESERVOIRS / 1.

Indirect gas-fired air heater

Audi-Larm Audible Alarm

HD Kompakt Service Manual

J SERIES. Technical Specifications. Centrifugal Pumps for J Series Condensate & Boiler Feed Pumps. Features

PVE SERIES POWER VENTER SYSTEM MANUAL

BERMAD Fire Protection

INSTRUCTION MANUAL DN0136 REVISION D

POWER VENTER. Model: PVE Series

CR64-1 A-F-A-E-HQQE 3x400D 50 HZ

INSTALLATION INSTRUCTIONS

CR A-F-A-V-HQQV 3x400D 50 HZ

CR A-F-A-E-HQQE 3x400D 50 HZ

CR32-4 A-F-A-E-HQQE 3x400D 50 HZ

INSTRUCTION AND REPAIR MANUAL

GENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

ECLIPSE INFORMATION GUIDE

POWER VENTER SYSTEM. Model: PVO-300, PVO-600

INSTALLATION INSTRUCTIONS WARRANTY

541D19 SERIES. Technical Manual. A Division of Aquion Partners L.P.

SECTION STEAM CONDENSATE PUMPS

Forced draught gas burner

Teflon Rotary Drum Pump

CR A-F-A-E-HQQE 3x400/ HZ

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:

DHI-300 DUCTABLE WASTE OIL HEATER

Transcription:

A AD Oil burners fuel unit deltapumps.com DE116-0709 A-AD_en_0709.pdf - 16.11.09 Page 1/1

Oil burners fuel unit Type A, AD 1- Applications The DELTA aluminium fuel unit type A is an efficient and modern oil burner pump, provided with bilateral delivery ports. Hub and shaft sizes are manufactured to international standards (EN 225), so it can be fitted to every oil burner. The pump type A is designed for pumping oil in high pressure oil burners and transfer pump applications. Its features allow an easy pump replacement with every other type of oil pump: the same unit is provided with nozzle port in both the left and right sides. For the use with low viscosity fuel (lower than 2.5cSt, i.e. Kerosene) standard pump can be used without exceeding 12 bar. To pump biodiesel or fuel containing it in any percentage, it is necessary the B version with special seals. On request the pump can be provided free of nonferrous metals. This unit must not be used to pump water or acid. 2- Operation The type A fuel unit consists of a pump, solenoid valve (A type only), filter and pressure regulator. The pumping action is obtained from two spur gears (2), one of which is connected to the drive shaft (3). The aluminium pump casting provides the various oil ways, for the suction (6), return (5) and nozzle ports (9). Pressure (8) and vacuum (7) gauge ports are also provided. On start up, the rotating gears purge the air from the suction chamber, through a vent groove in the piston to the return line in two pipe version, and through the nozzle line (after the solenoid valve opening) in one pipe version. On initial commissioning, it is possible to bleed the air more quickly, through the pressure gauge port. Because a vacuum now exists oil, due to atmospheric pressure, enters the suction chamber through the filter. From the suction side, the gears pass the oil to the pressure chamber, where it comes up against the head of the piston. Due to the build up of pressure, the piston is forced back against the pressure regulating spring. In the A type the flow of pressurized oil is interrupted by an incorporated solenoid valve (10), and can, therefore, be opened following the start of the motor (pre-purge), or interrupted before stopping the motor itself (instant shutoff of the flame preventing the nozzle dripping). The excessive oil discharges to the return side (or by-passes in the one pipe version). It will be realized of course that the spring tension, which is varied by the regulating screw (1), regulates the pressure of oil required. The AD type does not have a built-in solenoid valve. When the burner motor starts, the oil will be discharged from delivery ports straight away. If the AD pump is used to provide oil to the nozzle, a shut-off valve must be fitted in the nozzle line. The pump can be converted from the two pipe version to the single pipe version, removing the by-pass plug (4) from the vacuum port. When the unit is converted to the single pipe version, on initial commissioning the air must be bled through the pressure gauge port (in this case lift installation are not recommended). The cartridge filter (11) located in the front side, allows an easy cleaning without to dismount any part of the unit. Page2/2

3- Pump identification A 1 R 2 F A Pump type A = with built-in solenoid valve AD = without solenoid valve B prefix = biodiesel version (explicit request for nonferrous metals absence) Nozzle capacity (see graph) Rotation (seen from shaft end) R = clockwise L = counter clockwise Pipes system 1 = one pipe 2 = two pipes Coil type F = NF84 (coil with connector plug) Coil power supply A = 230 VAC 50/60Hz B = 110 VAC 50/60Hz C = 24 VAC 50/60Hz 4- Technical specifications Oil viscosity. 1,2 12 cst Oil temperature... 60 C max. Power consumption... See graphs Nozzle capacity... See graphs Fine adjustable pressure.... 6 20 bar Minimum pressure. 2,5 bar (for oil transfer applications) Suction line vacuum.. 0,5 bar max. Suction line pressure.... 2 bar max. Return line pressure.. 2 bar max. Starting torque 0,1 Nm max. Rotation speed.... 3500 rpm max. Standard strainer..... Stainless steel mesh 130µ, 11cm² Dimensions (EN 225). Hub Ø32, shaft Ø8 Connections (ISO 228/1)... Inlet Return : G1/4 Nozzle port : G1/8 Pressure vacuum gauge : G1/8 Weight.. A = 720 g AD = 600 g Standard factory settings Pressure setting: 10 ±0,3 bar Standard coil: 230 VAC 50/60Hz Standard cable set: 3 cores, 700 mm 5- Solenoid valve specifications (A type only) Power absorbed.. 9 W Voltage tolerance -15% / +10% Ambient temperature.... 0 C / 60 C Operating pressure... 25 bar max. Flow factor (VDI/VDE 2173).. 0,059 m 3 /h Cut-off pressure.. 6 bar Approval (EN 264).. TÜV No. 5S102/04 Page3/3

6- Diagrams Nozzle capacity Power consumption L/h 75 Visc. 5 cst (1.4 E) 2800 RPM 1400 RPM Watts 150 Visc. 5 cst (1.4 E) 2800 RPM 1400 RPM 50 100 A1 25 A1 50 5 10 15 20 Bar 5 10 15 20 Bar 7- Overall dimensions 1 Pressure regulation 3 Shaft sealing 4 By pass 5 Return 6 Suction 7 Vacuum gauge 8 Pressure gauge 9 Nozzle port 10 Solenoid valve 11 Cartridge filter Page4/4

8- By-pass installation To convert the A/AD fuel unit from the single pipe version to the two pipe version, do the following: 1. Using a 6 mm Allen wrench, remove the 1/4" plug from return port (Fig. 1). 2. Remove the 1/8" plug from vacuum port. 3. Using a 2.5 mm Allen wrench, insert and screw the bypass plug in the vacuum gauge port (Fig. 2). 4. Screw back the 1/8" plug into vacuum port. To convert the A/AD fuel unit from the two pipe version to the single pipe version, do the following: 1. Remove the 1/8" plug from vacuum port. 2. Using a 2.5 mm Allen wrench, unscrew the bypass plug from the vacuum gauge port (Fig. 2). 3. Screw back the 1/8" plug in the vacuum port 4. Insert and screw a 1/4" plug into the return port (Fig. 1). In the single pipe version, the air is bled through the nozzle line, after the solenoid valve opening. In the two pipe version the air is bled through the return port. After conversion, the air must be bled manually, through the pressure gauge. Make sure that the bypass plug is not used in a single pipe installation, because the fuel unit will not function properly and damage to the pump and burner motor could result. Page5/5

9- Installation and Maintenance 1. Make sure that the by-pass plug is not used in a single pipe installation. 2. Do not use fuel with additives to avoid the possible formation over time of compounds which may deposit between the gear teeth, thus obstructing them. 3. After filling the tank, wait before starting the burner. This will give any suspended impurities time to deposit on the bottom of the tank, thus avoiding the possibility that they might be sucked into the pump. 4. On initial commissioning a dry operation is foreseen for a considerable length of time (for example, when there is a long suction line to bleed). To avoid damages inject some lubrication oil into the vacuum inlet. 5. Care must be token when installing the pump not to force the pump shaft along its axis or laterally to avoid excessive wear on the joint, noise and overloading the gears. 6. In the A type pump do not force the valve stem and do not use it as lever. If the AD pump is used to provide oil to the nozzle, a shut-off valve must be fitted in the nozzle line. 7. Pipes should not contain air pockets. The number of junctions should be kept to a minimum as they are a possible source of leakage. 8. Rapid attachment joint should therefore be avoided. Always use O-Rings or mechanical seal (copper or aluminium gaskets) junctions if possible. 9. Avoid overtightening: G1/8" 15 Nm max. G1/4" 20 Nm max. 10. Do not use PTFE tape on the suction and return line pipes to avoid the possibility that particles enter circulation. These could deposit on the pump filter or the nozzle, reducing efficiency. 11. When junction threads, elbow joints and couplings are sealed with removable glue, avoid excessive quantities, which could enter in the oil ways and damage to the pump could result. 12. To clean the filter, unscrew the plug using a 4 mm Allen wrench. Remove the cartridge from the unit and extract the inox mesh. When reassemble, cartridge must be oriented with the radial hole toward the inlet port. It must be thoroughly cleaned at least once in a season to ensure correct working of the fuel unit. An external filter should always be installed in the suction line upstream of the fuel unit. 13. Make sure the combustion chamber is free of oil or oil vapor before operating the system. CAUTION Turn off all power before servicing any part of the system. 10- Nozzle Pressure Test Most nozzles ratings are based upon 100 PSIG (6,89 Bar) delivered oil pressure. The flow rate at the desired pressure must be estimated using the nozzle manufacturers data sheets. To insure that oil is delivered to the burner nozzle at the desired pressure, do the following: 1. Remove the 1/8" plug from the port marked "P" and connect a pressure gauge to this port (use a gauge of 0 to 20 Bar or greater). The "P" port (Pressure Gauge Test Port) has been provided specifically for the connection of the pressure gauge for measuring the nozzle pressure; however, when available, it is also permissible to use the vent port for measuring nozzle pressure. 2. Start the burner motor, energize the solenoid valve and vent all air from the fuel unit and connected suction line system. 3. Check the adjustable nozzle pressure range of the fuel unit, using a 4 mm Allen wrench, turning the adjusting screw counter clockwise to lower the nozzle pressure and clockwise to increase the nozzle pressure. Adjust the nozzle pressure in accordance with the burner manufacturers specifications. 11- Nozzle Cut-Off Test (A type only) Fuel oil is not compressible but air is. Air trapped in the nozzle line, anywhere between the fuel units nozzle port and the nozzle itself, will compress during burner operation. Following burner shutdown, any trapped compressed air will expand displacing the oil in the nozzle line, forcing continued oil flow through the nozzle that will, in effect, falsely appear to be poor fuel unit Cut-Off. This occurrence is particularly common with low flow rate nozzles used in conjunction with long air tubes. To verify positive nozzle Cut-Off after burner shutdown, do the following: 1. Remove the nozzle line and fitting from the nozzle port of the fuel unit and connect a 1/8" pressure gauge to the nozzle port (a gauge of 20 Bar or greater be used). It may be more convenient to use a gauge fitted out with an extension nipple or with a line and flare nut to connect directly to the fitting installed into the nozzle port. If any type of extension is used between the nozzle port and the gauge, it should be kept as short as possible to minimize the amount of trapped air. 2. Start the burner motor, energize the solenoid valve and vent all air from the fuel unit and connected suction line system. 3. Shut off the burner motor. Initially the pressure will drop and then stabilize within a second or two. The pressure reading on the gauge should stabilize at 6 Bar or greater and hold for at least two minutes. 12- Vacuum Test The vacuum test is necessary to verify the fuel unit's suction ability, to evaluate the leak tight integrity of the entire fuel unit and connected oil suction line piping system, to confirm that there are no abnormal restrictions in the oil suction line system, and, to confirm that the system vacuum is within the allowable specification limits of the unit. Please watch in any case the graphs for maximum suction line length depending on line diameter, viscosity, difference in height of suction line and pump or nozzle capacity. To perform the test, do the following: 1. Remove the 1/8" plug from the port marked "V" and connect a vacuum gauge to this port. 2. Start the burner motor, energize the solenoid valve and vent all air from the fuel unit and connected suction line system. 3. With the burner motor running, close the valve connected to the inlet port. You will note that the vacuum as measured by the vacuum gauge will increase. Allow the burner motor to continue to run until the highest vacuum reading is achieved. A fully primed fuel unit in good condition should be capable of pulling at least 0,7 Bar. If not, before condemning the fuel unit, be sure that all connections and plugs are tight and the valve is in good working order. 4. De-energize the solenoid valve and shut off the burner motor. Initially, the vacuum reading will drop and then stabilize within a second or two. Once the vacuum reading stabilizes, record the reading. If the fuel unit is free of leaks, this reading should hold constant for at least 2 minutes. If the vacuum reading drops, there is a leak that must be located and corrected. 5. When each leakage is removed and the valve onto suction line is open, check to be sure that the actual operating vacuum does not exceed 0,5 Bar. Elettromeccanica Delta S.p.a. reserves the right to update or make technical changes without prior notice. Page6/6