NOVALYNX CORPORATION MODEL A EVAPORATION PAN AUTOMATIC REFILL SYSTEM INSTRUCTION MANUAL

Similar documents
NOVALYNX CORPORATION MODEL A & A SLING PSYCHROMETER INSTRUCTION MANUAL

NOVALYNX CORPORATION MODEL 200-WS-21-A DUAL SET POINT WIND ALARM INSTRUCTION MANUAL

NOVALYNX CORPORATION

NovaStar 4X Pager Alarm Software 5073NS4X-AD DCN-M409

Global Water Instrumentation, Inc.

Model 20201/20201-A/20201-B Wind Sensor Heater. User's Manual. All Weather Inc National Drive Sacramento, CA USA

EOS. Instruction Manual. 120V High Amperage Digital Humidity Controller. Part #

Air Pump Up to 800 gallons


Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

Frosty Factory of America, Inc.

Henny Penny Blast Chiller/Freezer Models BCC/BCR-140 Models BCC/BCR-175 Models BFR/BCR-350

Global Water Instrumentation, Inc.

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

Model 5190-F Temperature/Humidity Probe

Part No Revised: October 2004 BUN WARMER. Instruction Manual. Models:8018,8019,8117,8219,8170

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

Sound Cover [ , , , ]

ADVANTAGE SERIES KXRP28 AIR-TO-AIR HEAT EXCHANGER

Notes: 1 Square = 1 Foot

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

Global Water Instrumentation, Inc.

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

Model 5190-E Temperature/Humidity Probe

RPI Industries, Inc.

KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER

Compressed Air Dryer

IFS Fiber Module Installation & Operation Instructions

EQUIPMENT Operation Manual

Ledco XL-44 Wide Format Pouch Laminator

User's Guide. Pinless Moisture Meter. Model MO257

Fan Speed. Auto Swing. Timer. Power. Mode. Fan. Only. Saver. Temp. Dry. Fan. Speed. Auto Swing. Timer. Power. Mode. Saver. Only. Temp.

Model 8710 Wireless Thermostat. Owner s Manual. Includes Operating Instructions and Warranty Information READ AND SAVE THESE INSTRUCTIONS

Installation and Operations Manual

Cat 5 Pro Vacuum OPERATOR S MANUAL

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

KPHE32 SERIES WATER-TO-AIR HEAT EXCHANGER

IFS Fiber Module Installation & Operation Instructions

Cincinnati, OH USA

Tsunami 6 Site Ebb & Flow Gro System Instruction Manual

KNHE30 SERIES WATER-TO-AIR HEAT EXCHANGER

VT1101M VT1102M IFS Fiber Module Installation & Operation Instructions

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

Condiment Warmer. Instruction Manual Models #2252EX & #2253EX. Cincinnati, OH USA. Model #2252EX. Model #2253EX

Horizontal Bottle Cooler Installation and Operation Manual

IFS Fiber Module Installation & Operation Instructions

Owner s Manual Refrigerated Compressed Air Dryer Model F-50

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

Portable Air Conditioner with Evaporative Technology PE6-10R-03 Operating Instructions. Model No. PE6-10R Soleus Air International

ADVANTAGE SERIES KXRP33 AIR-TO-AIR HEAT EXCHANGER

Zeus Extreme Owner's Manual

3800 North Mill Road Vineland, NJ USA Tel: Fax: Web: Rev. A

Large Combo Warmer Instruction Manual Model #2206

Installation & Service Manual

KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER

RPI Industries, Inc.

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

Model 2016, 2025, 2025BN, 2025ST Staging Cabinets Instruction Manual

EQUIPMENT Operation Manual

RPI Industries, Inc.

SACKSAFOAM QUICK FILL OPERATIONS MANUAL 2019A

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

CD6102 / CD6102 OC / CD6102-2

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions

Desiccant / Pump Dehumidification System. Model Operating Manual

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

Panel Mounted Heat Exchangers by Dantherm, Inc.

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

WARNING. Pro Pack Portable Spray Pack 3A1292C. Operation. Model 24F893 Maximum Working Pressure 12 psi (0.83 bar, MPa)

COMMERCIAL REFRIGERATOR INSTRUCTION MANUAL

Models: DB-2-HF, DB-3-HF, DB-4-HF, and DB-5-HF. For Service Information, Call

Hot Dog Roller Grills

Operation Manual and Parts Directory

Part No Revised November / Instruction Manual Model #8150 AND #8151

Portable Air Conditioner and Heater With Heat Pump Technology Operating Instructions. Model No.: PH3-12R-03 Reference No.: KY2-34

HOT DOG STEAMER Instruction Manual Models: 8007 & 8012

KARMEL KING Instruction Manual Models: 2620 & 2621 (240 Volt) 2630 & 2631 (208 Volt) Part No Revised: February 2009

IMPORTANT: DO NOT DO NOT DO NOT DO NOT DO NOT DO NOT DO NOT DO NOT DO NOT DO NOT

Pressurized Filter Up to 1250 gallons

Part No Revised December 2002 DESIGNER SERIES NACHO CABINETS Instruction Manual Model #5510, 5511 AND 5512

OWNERS MANUAL For IN ROOM BREWING SYSTEM MODEL REFILLABLE CAPSULES K901. Includes: Installation Use & Care Servicing Instructions

IFS Fiber Module Installation & Operation Instructions

Operating Instructions Manual. Condensate Separators. Models 4GNL3 thru 4GNL9 and 53RG84 thru 53RG95

FOR EASY, FAST INSTALLATION AND FOR RESULTS

Part No Revised November 2004 DESIGNER SERIES NACHO CABINETS Instruction Manual Model #5513

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

Operating Instructions

InstructIon Manual KrEs EQuIPMEnt stands

Warmer Cabinet Instruction Manual Model # 5581, 5581EX. Part No

Quality Refrigeration OWNER S MANUAL. Instructions for the installation, operation and maintenance of Traulsen: Heated Banquet & Transport Carts

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

Thermometer with Wired Sensor

Econo-16 Models 2024EX, 2024STX 16oz. Popcorn Machine Instruction Manual

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

Turbo Air Speed up the Pace of Innovation TBB-4SB CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT

ADVANTAGE SERIES KXRP47 AIR-TO-AIR HEAT EXCHANGER

Bag-In-A-Box Oil System Instruction Manual Model #2257EX & 2257DX For Export Bag-In-Box Pumps Made After March 2003

Field Top Mounted Condensing Unit

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

Transcription:

NOVALYNX CORPORATION MODEL 255-620-A EVAPORATION PAN AUTOMATIC REFILL SYSTEM INSTRUCTION MANUAL REVISION DATE: JUNE 2016

Receiving and Unpacking Carefully unpack all components and compare to the packing list. Notify NovaLynx Corporation immediately concerning any discrepancy. Inspect equipment to detect any damage that may have occurred during shipment. In the event of damage, any claim for loss must be filed immediately with the carrier by the consignee. Damages to equipment sent via Parcel Post or UPS require the consignee to contact NovaLynx Corporation for instructions. Returns If equipment is to be returned to the factory for any reason, call NovaLynx between 8:00 a.m. and 4:00 p.m. Pacific Time to request a Return Authorization Number (RA#). Include with the returned equipment a description of the problem and the name, address, and daytime phone number of the sender. Carefully pack the equipment to prevent damage or additional damage during the return shipment. Call NovaLynx for packing instructions in the case of delicate or sensitive items. If packing facilities are not available take the equipment to the nearest Post Office, UPS, or other freight service and obtain assistance with the packaging. Please write the RA# on the outside of the box. Warranty NovaLynx Corporation warrants that its products are free from defects in material and workmanship under normal use and service for a period of one year from the date of shipment from the factory. NovaLynx Corporation's obligations under this warranty are limited to, at NovaLynx's option: (i) replacing; or (ii) repairing; any product determined to be defective. In no case shall NovaLynx Corporation's liability exceed product's original purchase price. This warranty does not apply to any equipment that has been repaired or altered, except by NovaLynx Corporation, or that has been subjected to misuse, negligence, or accident. It is expressly agreed that this warranty will be in lieu of all warranties of fitness and in lieu of the warranty of merchantability. Address NovaLynx Corporation 431 Crown Point Cir Ste 120 Grass Valley, CA 95945-9531 USA Phone: (530) 823-7185 Fax: (530) 823-8997 Email: nova@novalynx.com Website: www.novalynx.com Copyright 1988-2016 by NovaLynx Corporation i

TABLE OF CONTENTS Section No. Page No. 1.0 INTRODUCTION................................................... 1 1.1 Specifications................................................. 1 2.0 INSTALLATION.................................................... 1 3.0 OPERATION...................................................... 2 Theory of Operation............................................... 2 Example of Program Cycle......................................... 2 4.0 TIMER INSTRUCTIONS.............................................. 3 ii

MODEL 255-620-A EQUIPMENT CONFIGURATION AND IDENTIFICATION iii

1.0 INTRODUCTION NovaLynx Corporation Model 255-620-A Evaporation Pan Automatic Refill System Instruction Manual NovaLynx Corporation has designed a simple and easy-to-use system for automatically refilling the evaporation pan at specified times. The 255-620-A Auto Refill System has two major parts. The first part is a digital electronic water timer powered by one 9V battery. The second part is the automatic float valve. An operation manual for the timer is included for detailed setting Instructions. 1.1 Specifications Power: One 9V alkaline battery (included) Operating temperature: 3 to 50 C (37.4 to 122 F) Operating humidity: 0-100% RH Housing: High grade polystyrene Water connection: Standard garden hose fitting Size: 8" x 6" x 4" approx Weight/Shipping: 4 lbs/7 lbs 2.0 INSTALLATION 1. Attach the 255-620-A to the evaporation pan using the supplied hardware. 2. Connect to a water source (2 psi to 100 psi) using a standard garden hose (not included). 3. Install the battery and program the timer for desired filling times (weekly, daily, etc.) 4. This completes the installation. Removing front cover >>> 1

3.0 OPERATION Theory of Operation The automatic refill system allows water to flow into the evaporation pan from an external water source. The timer turns the water on at a user specified time and it remains on for a short time. The automatic float valve will stop the water flow at approximately 8-1/2" to 9-1/2" (depending upon water pressure). Then the timer shuts off the water flow until the next programmed time. Note: Approximately 8 gallons of water will change the pan level by 1 inch. IMPORTANT: Prior to freezing weather, remove timer from the faucet or water source, drain all water, and store inside with batteries removed. Severe damage will occur below 37.4 F (3 C). Example of Program Cycle A typical cycle to fill the pan every Monday at 7:00 am would be: Refer to the electronic timer manual for detailed instructions. A PDF version of the manual is available on our website (novalynx.com). Install battery first. Set current time on the timer. Timer operates on MILITARY (24 HOUR) TIME ONLY. Set program start (open) time at 07:00. Set program stop (closed) time at 07:10. This assumes that 10 minutes is sufficient time to fill the pan with the existing water pressure. A longer time may be required for remote locations where water tanks with slower gravity flow are used to fill the pan. Set days to water. Days of the week are represented by numbers 1-7. Assuming Sunday is the 1st day of the week, select only number 2 for Monday. All other numbers should be turned off. The function on the above setting will be: On Monday at 7:00 am the water flow will turn on and start to fill the evaporation pan. When the pan fills to about 9" deep the automatic float valve will stop the water flow. After 10 minutes the timer will close the valve and any water flow will stop. The following Monday at 7:00 am the cycle will start over again. 2

4.0 TIMER INSTRUCTIONS 3

4