Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

Similar documents
T9MPV. 2- Stage Variable Speed 90. Flexibility. Comfort. Efficiency. Quality. Service (05/2006)

T9MPV SmartComfort VS90 Product Specifications

H9MPV. 2- Stage Variable Speed 90. Flexibility. Quality. Comfort. Efficiency. Service (7/2004)

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM range

Cooling Capacity CFM in. w.c. (125 Pa)

Wt. Lbs Model Number (BTUH) Hz

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

G6RC Series TECHNICAL SPECIFICATIONS

Cooling Capacity CFM in. w.c. (125 Pa)

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

TECHNICAL SPECIFICATIONS

RG7D 1-Stage Heat Series

FG7T (C and L Series)

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

Product Data PG9MXA 4-WAY MULTIPOISE TWO-STAGE CONDENSING GAS FURNACE

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

Cooling Capacity CFM in. w.c. (125 Pa)

TECHNICAL SPECIFICATIONS

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

TSTAT0101SC Recommended (order separately)

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

MERIT SERIES Downflow

TSTAT0201CW Recommended (sold separately)

TSTAT0101SC Recommended. Cooling Capacity CFM in. w.c. (125 Pa)

TECHNICAL SPECIFICATIONS

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY

Gas Furnaces. Gas Furnaces. 2-Stage Variable-Speed. 2-Stage Multi-Speed Multipoise. Multipoise 80AFUE. 2-Stage Variable-Speed Multi-Speed Multipoise

Product Data. 58MSA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 110 Input Capacities: 40,000 thru 120,000 Btuh

TECHNICAL SPECIFICATIONS

Product Data. 58MCA 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace Series 111 Input Capacities: 40,000 thru 120,000 Btuh

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces

GAS FURNACES. RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above)

GAS FURNACES SELECT 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

Multi-Position Gas Furnaces

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. )

COMFORT CONTROL 90 PLUS WITH DUAL TWO-STAGE UPFLOW GAS FURNACES

MULTI POSITION GAS FURNACE

Product Data. 58PAV Energy-Efficient Induced-Combustion Upflow Furnace. Input Capacities: 45,000 thru 155,000 Btuh. 80% AFUE At Budget Price

Rheem Classic Series Multi-position Gas Furnaces

Energy Saving. Space Saving.

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY UPFLOW GAS FURNACES

Model PG9MAB MULTIPOISE CONDENSING GAS FURNACE SS-PG9MAB-01. Time Roman FEATURES. burners seldom, if ever, needs cleaning.

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

Product Data. S Unit may also be sidewall vented with an approved A S OVL units equipped with optional ECM 2.3 Variable

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

Product Data. 925SA PREFERREDt SERIES SINGLE -STAGE 4-WAY MULTIPOISE CONDENSING GAS FURNACE, SERIES A LIMITED WARRANTY*

G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2.

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

Product Data. ama. 58BLA, 58BMA, and 58BTA Oil-Fired Furnaces. 58BLA Low-Boy. Copyright 1996 Carrier Corporation

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

MULTI POSITION GAS FURNACE

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

Product Data. 58TUA WeatherMaker 8000TS with Comfort Heat Technology Deluxe Upflow Furnace

Product Data. 58TUA WeatherMaker 8000TS with Comfort Heat Technology Upflow Furnace. Series 120 Input Capacities: 40,000 thru 135,000 Btuh

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

Ruud Achiever Series Multi position Gas Furnaces

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace

Ruud Achiever Plus Series Multi-position Gas Furnaces

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. )

GMS9/GCS9 SERIES 93% AFUE

Product Data. 58MXA Deluxe 4-Way Multipoise Fixed-Capacity Condensing Gas Furnace. Series 111 Input Capacities: 40,000 thru 120,000 Btuh

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

GAS FURNACES SILHOUETTE II PLUS 2 LXE TWO STAGE 80% A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

90TJ SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to kw] (All Models 90% A.F.U.E. or Above)

Rheem Classic Plus Series Multi position Gas Furnaces

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat

355MAV Sizes 040 thru 120 Series E

Product Data. 58MCA 4-Way Multipoise Fixed-Capacity Direct-Vent Condensing Gas Furnace Series 131 Input Capacities: 40,000 thru 120,000 Btuh

GAS FURNACES CLASSIC 95% A.F.U.E. HIGH EFFICIENCY UPFLOW GAS FURNACES

MERIT SERIES Downflow

Product Data OBM/OVM. MULTIPOISE OIL FURNACE INPUT CAPACITIES 70,000 thru 154,000 BTUH THE LATEST IN OIL FURNACE TECHNOLOGY

Product Data 987MA EVOLUTIONR MODULATING 4 -WAY MULTIPOSE, VARIABLE SPEED CONDENSING GAS FURNACE, SERIES A LIMITED WARRANTY*

TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92 AFUE DESCRIPTION WARRANTY FEATURES Rev.

Product Data. 59TP5A Performance Boost Two---Stage Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY*

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

Rheem Classic Series Downflow/ Horizontal Gas Furnaces

Product Data PG9MAB MULTIPOISE CONDENSING GAS FURNACE 3 -PASS PRIMARY HEAT EXCHANGERS FLOW -THROUGH SECONDARY HEAT EXCHANGERS MONOPORT INSHOT BURNERS

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

Product Data. 59SP5A Performance Boost, Single---Stage Way Multipoise Condensing Gas Furnace Series 100 LIMITED WARRANTY*

ELITE SERIES Downflow - High Efficiency Blower Motor

Product Data. 58MVP Deluxe 4-Way Multipoise Variable-Capacity Condensing Gas Furnace. Series 121 Input Capacities: 40,000 thru 120,000 Btuh

Transcription:

DIRECT OR NON -DIRECT VENT 4-WAY MULTIPOISE CONDENSING GAS FURNACE 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal FLEXIBILITY S Dual certified venting (1 or 2 pipes) Direct Vent furnace S 40 (1016 mm) high with wider cabinets, for ease of installation S Factory shipped for natural gas, with Propane Gas conversion kits available S Multipoise - Upflow/downflow/horizontal installation S Vent pipe can be run horizontally or vertically S Internal condensate drain system SERVICE S Self diagnostics S Entire blower assembly mounted on rails Product Data COMFORT S Adjustable timed blower Off delay S Thermal lined, one piece steel cabinet for noise reduction S 24 and 115 VAC humidifier terminal S Electronic air cleaner terminal S Insulated blower compartment EFFICIENCY S 95% AFUE, upflow / downflow S Up to 95%* AFUE, horizontal S Single stage gas valve operation S Single stage integrated control S Multispeed, permanently PSC blower motors S Induced draft blower S In -shot burners S California NOx approved QUALITY S Stainless steel primary heat exchanger S Stainless steel secondary heat exchanger S High temperature limit control prevents overheating S Dependable hot surface ignition with Silicon Nitride igniter S Flame roll-out sensors standard *See Furnace Specifications for clarification A09325 APPLICATION HAZARD Failure to follow this warning could result in personal injury or death This furnace is not designed for use in mobile homes, trailers, or recreational vehicles. C! WARNING CERTIFIED E D E S R T I G N I F I E D ama As an ENERGY STAR Partner, we have determined that this product meets the ENERGY STAR guidelines for energy efficiency. 1

FURNACE SPECIFICATIONS Model Number NATURAL GAS 036060 036080 048080 060100 INPUT (btuh){ 60,000 80,000 80,000 100,000 HTG. CAP. (btuh) 58,000 77,000 77,000 96,000 AFUE* - Upflow / Downflow 95 95 95 95 AFUE* - Horizontal 95 94.4 95 95 NOx (Ng/J) <40 <40 <40 <40 TEMP. RISE DEGREES - o F( o C) 30-60 (17-33) 35-65 (19-46) 30-60 (17-33) 30-60 (17-33) VOLTS/HZ/PH 115/1/60 115/1/60 115/1/60 115/1/60 MIN./MAX. VOLTAGE 104/127 104/127 104/127 104/127 RATING PLATE AMPS. 10 10.5 13.6 14.8 TRANSFORMER (V.A.) 40 40 40 40 GASPIPESIZE -In(mm) 1/2 (13 mm) 1/2 (13 mm) 1/2 (13 mm) 1/2 (13 mm) VENT SIZE^ 2 or 3 (51or76mm)OD 3 (76 mm) OD 3 (76 mm) OD 3 (76 mm) OD COOLING CAP. 3.0 3.0 4.0 5.0 FILTER SIZE - In (mm) (1 required) 16 x 25 x 1 16 x 25 x 1 16x25x 1(2) 16x25x1(2) DIMENSIONS - HEIGHT In (mm) 40 (1016) 40 (1016) 40 (1016) 40 (1016) DIMENSIONS - WIDTH X DEPTH - In (mm) 19 1 / 8 x29 (487 x 737) 22 3 / 4 x29 (573 x 737) 22 3 / 4 x29 (573 x 737) 2 x29 (622 x 737) WEIGHT - Lbs. (Kg.) 153 (69.3) 172 (78.0) 180 (81.6) 193 (87.5) * Capacity and AFUE in accordance with U.S. Government DOE test procedures. {Gas input ratings are certified for elevations to 2000 ft. (610 M). For elevations above 2000 ft. (610 M), reduce ratings 2% for each 1000 ft. (305 M) above sea level. In Canada, derate the unit 5% for elevations 2000 to 4500 ft. (610 to 1372 M) above sea level. ^ Vent size may vary depending on length, number of elbows, standard vent or direct vent. See Installation Instructions. MAX CFM s for Factory Washable Filters Filter Size (In. / mm) CFM 14 X25 356 x 635) 1400 16 X25 (406 x 635) 1600 20 X 25 (508 x 635) 2000 24 X 25 (610 x 635) 2500 Max CFM based on 600 FPM # CFM --- Cubic Feet per Minute airflow. Filter required for each return---air inlet. Airflow performance includes 1 (25 mm) washable (600 FPM max) filter media. Disposable filters are typically rated at 300 FPM and only allow half of the airflow when compared to 600 FPM filters. Example: 20 x 25 @ 600 FPM = 2000 CFM, @ 300 FPM = 1000 CFM. 2

ACCESSORIES Model Number Description Used With Models KGANP48011HW Gas Conversion Kits - Natural gas to propane conversion Kit. Allows field conversion to propane gas. KGAPN41011HW Gas Conversion Kits - Propane to natural gas conversion kit. Allows field conversion to natural gas. KGAFR0901P16 Filter Kits - External filter frame. 16 x25 (406 x 635 mm) KGAFR1001P20 Filter Kits - External filter frame. 20 x 25 (508 x 635 mm) P908-0001 + Condensate neutralizer kit - for condensing gas furnaces All if required KGAVT0801CVT KGAVT0701CVT 3 (76 mm) Concentric vent kit - allows single wall penetration for 2 pipe direct vent applications (90+). 2 (51 mm) Concentric vent kit - allows single wall penetration for 2 pipe direct vent applications (90+). 036060 036080 048080 060100 036060 036080 048080 060100 KGAHA6201PSW High Altitude Pressure Switch Kit 036060 KGAHA6301PSW High Altitude Pressure Switch Kit 036080 048080 KGAHA6401PSW High Altitude Pressure Switch Kit 060100 KGASB0301P01 KGASB0401P02 Combustible Floor Base used without cased coil used KGASB0801P06 KGASB0501P03 KGASB0601P04 Combustible Floor Base used with cased coil used KGASB0701P05 KGADA0101PYN Downflow Coil Adapter used between furnace and coil 333730-701 Size 41 333730-702 Size 42 333730-703 Size 43 333730-704 Size 44 333730-705 Size 45 333730-709 Size 46 333730-710 Orifice Kit + (Qty. 5) Size 47 333730-711 Size 48 333730-712 Size 49 333730-706 Size 54 333730-707 Size 55 333730-708 Size 56 + Must be ordered from Replacement Components Division The direct-vent 4 -way multipoise gas furnace has been designed to work specifically with A -coils offered by Bryant. furnaces are not N -coil compatible. The following table shows our recommended furnace coils: These Model Evaporator Coil Coil Dimension - In. (mm) 036060 CA*MP4823ACA 29-3/4 x 22-7/8 x 20-5/8 (756 x 581 x 524) 036080 CA*MP4823ACA 29-3/4 x 22-7/8 x 20-5/8 (756 x 581 x 524) 048080 CA*MP4823ACA 29-3/4 x 22-7/8 x 20-5/8 (756 x 581 x 524) 060100 CA*MP6025ACA 35x24-1/2x20-5/8 (889 x 622 x 524) 3

BLOWER PERFORMANCE Model Number 036060 (1)(2) 036080 (1)(2) 048080 (1)(2) 060100 (1)(2) BLOWER SIZE IN. (mm) (DIA. x WIDTH) MOTOR H.P. (TYPE) 1 / 2 (PSC) 1 / 3 (PSC) 1 / 2 (PSC) 3 / 4 (PSC) MOTOR SPEEDS 4 4 4 4 AIRFLOW DATA (CFM) Furnace External Static Pressing (in wc).10 ESP in wc.20 ESP in wc.30 ESP in wc.40 ESP in wc.50 ESP in wc.60 ESP in wc.70 ESP in wc.80 ESP in wc.90 ESP in wc 1.00 ESP in wc Furnace Motor Speed Selection Airflow - CFM LOW 703 976 922 1820 MEDIUM LOW 901 1123 1246 1993 MEDIUM HIGH 1204 1326 1690 2137 HIGH 1478 1456 2032 2240 LOW 649 941 898 1768 MEDIUM LOW 864 1112 1250 1934 MEDIUM HIGH 1154 1312 1650 2062 HIGH 1418 1440 1952 2163 LOW 588 909 872 1722 MEDIUM LOW 818 1085 1226 1872 MEDIUM HIGH 1103 1280 1601 1992 HIGH 1350 1420 1874 2083 LOW 538 870 838 1656 MEDIUM LOW 765 1043 1187 1801 MEDIUM HIGH 1053 1241 1533 1916 HIGH 1280 1379 1785 2002 LOW 488 818 806 1590 MEDIUM LOW 720 1002 1151 1723 MEDIUM HIGH 993 1209 1462 1833 HIGH 1201 1325 1688 1912 LOW 459 784 769 1513 MEDIUM LOW 672 952 1090 1636 MEDIUM HIGH 924 1155 1381 1745 HIGH 1116 1261 1593 1821 LOW 408 714 711 1426 MEDIUM LOW 620 893 1014 1547 MEDIUM HIGH 846 1082 1287 1654 HIGH 1023 1208 1482 1727 LOW 365 640 643 1325 MEDIUM LOW 558 792 918 1437 MEDIUM HIGH 764 1001 1182 1551 HIGH 931 1115 1360 1618 LOW 317 567 570 1199 MEDIUM LOW 489 702 790 1315 MEDIUM HIGH 683 868 1053 1430 HIGH 825 1007 1231 1502 LOW 233 491 488 1047 MEDIUM LOW 428 608 678 1159 MEDIUM HIGH 590 746 850 1275 HIGH 730 830 1052 1356 NOTE: (1) Data based on Bottom Only or One Side return. NOTE: (2) Gray area is above maximum temperature rise range. 4

DIMENSIONS - IN. (MM) Cabinet to Combustible Clearances TOP BOTTOM RH LH BACK FRONT FLUE 1 (25) 0 (0) 0 (0) 0 (0) 0 (0) 3 (76) 0 (0) 2 1 / 4 (57.2) 13 1 / 4 (336.6) TOP LEFT SIDE TRAP (KO) (COUNTERFLOW) AIR INTAKE (KO) (ALTERNATE) GAS VENT TRAP (KO) UPFLOW/HORIZONTAL THERMOSTAT (KO) E 4 13 / 16 (122.2) F 7 (177.8) G AIR INTAKE VENT H 6 11 / 16 ELECTRICAL (177.5) 1 1 / 4 (318) 1 1 / (27) 16 13 11 / 16 (347.7) 31 11 / 16 (34.9) (804.9) 1 3 / (758.8) 8 29 7 / 8 28 3 / 4 (730.3) 24 1 / 16 17 5 (611.2) / 16 19 13 /16 (439.7) 1 11 (503.2) / 16 (42.9) A B FRONT MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS FOR ALL UNITS - in (mm) REAR 0 FRONT (combustion air openings in 3 (76.2) furnace and in structure) Required For Service *24 (609.6) ALL SIDES Of SUPPLY PLENUM 1 (25.4) SIDES 0 VENT 0 TOP OF FURNACE 1 (25.4) *30 (762mm) clearance recommended for furnace removal. Horizontal position: Line contact is permissible only between lines formed by intersections of top and two sides of furnace jacket, and building joists, studs or framing. NOTE: Evaporator A coil drain pan dimensions may vary from furnace duct opening size. Always consult evaporator specifications for duct size requirements. Furnace is designed for bottom return or side return. Return air through back of furnace is NOT allowed. 1 1 / 4 (31.7) 21 5 / 8 1 7 (549.3) / 8 (47.6 ) 24 (609.6) 4 7 / 8 (123.8) Drawing is representative, but some models may vary 2 7 / 8 (73) 4 5 / (109.5) 16 2 3 / 8 (60.3 ) 1 1 / (27) 16 28 1 / 2 (723.9) 18 1 / 2 3 / 4 (19.1) (469.9) TYPE D BOTTOM GAS (KO) RIGHT SIDE TRAP (KO) (COUNTERFLOW) C ELECTRICAL (KO) 23 1 / 8 3 7 AIR INTAKE (KO) / 8 (587.4) (98.4) ALL DIMENSIONS: in (mm) (ALTERNATE) 1 3 / 4 13 / 16 16 (30.2) (122.2) VENT (KO) TRAP (KO) 1 1 / 16 HORIZONTAL 29 7 / 8 (27) (758.8) 7 21 / 27 3 / 4 16 (690.6) 21 5 (177.8) (57.2) / 8 THERMOSTAT 9 13 / 16 (549.3) (249.2) 17 5 / 13 1 / 4 16 33 11 / 16 (439.7) (336.6) (855.7) 1 11 / 16 (KO) (42.9) 40 (1016) Unit Capacity Cabinet Bottom Top A B C D E F G H KO = KnockOut 47 / 215 / 8 8 (123.8) (549.3) 17 / 8 24 (47.6) (609.6) 036060 19 1 / 8 (485.8) 17 5 / 8 (447.7) 2 1 / 8 (54) 14 3 / 4 (374.7) 2 1 / 2 (63.5) 9 1 / 2 (241.3) 036080 22 3 / 4 (577.9) 21 1 / 4 (539.8) 1 15 / 16 (49.2) 18 3 / 4 (476.3) 2 1 / 2 (63.5) 9 1 / 2 (241.3) 048080 060100 22 3 / 4 (577.9) 2 (622.3) 21 1 / 4 (539.8) 23 (584.2) 1 15 / 16 (49.2) 7 / 16 (11.1) 18 3 / 4 (476.3) 23 (584.2) 2 5 / 8 (66.7) 2 1 / 4 (57.2) 11 3 / 8 (288.9) 12 1 / 4 (311.2) Specifications are subject to change without notice. A09268B 5

E2009 Bryant Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 06/09 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Catalog No. PDS--- 01 Replaces: NEW 6