HIGH PRESSURE WATER MIST SYSTEM Application: High Rise Building Bindreiter Michael London,

Similar documents
FIRE DEPARTMENT - RULES FOR FIRE PROTECTION IN AUSTRIA

BUILDING INDUSTRY TUNNEL RAIL BUILDING & INDUSTRY FIRE FIGHTING WITH HIGH PRESSURE WATER MIST

Some Important Aspects of Fire Safety Regulations about High Rise Buildings

Enclosure 4- RISK ASSESSMENT

Fire protection solutions for ships and offshore facilities BRANCH SOLUTION

Technical write-up on Fire safety services

Fire protection for buildings

Fire protection solutions for ships and offshore facilities

BUILDING INDUSTRY TUNNEL RAIL TUNNEL FIRE FIGHTING WITH HIGH PRESSURE WATER MIST

Increasing Fire Safety of Cologne Main Station by High Pressure Water Mist

Fire Safety Concept Hotel Jumeirah

FIRE PROTECTION SYSTEMS IN BURJ KHALIFA. By NAFFCO Fire Protection

Emergency Action and Fire Prevention

WATER MIST CONVENTION AND EXHIBITION

Design of Fire safety in Multi Occupancy Residential Accommodation

Fire Protection for Printing Machines with High Pressure Water Mist

General Principles of Smoke Control

Case study: EconAqua water mist sprinkler system

Outline of Measures for Fire Prevention and Safety under the Laws and Regulations of Fire Fighting

GAUTENG DEPARTMENT OF INFRUSTRUCTURE DEVELOPMENT

Certification Assessment Instrument and Guidelines

NITOL INSURANCE COMPANY LIMITED

Water mist fire suppression systems. Minifog ProCon Low-pressure water mist system

F.R.A.M.E. calculation report. This report is generated by the "FRAME for Windows program " The calculation is made for: Airport_building

Hot Topic. a Guide to Help Prevent Fire Damage

Installation and Maintenance Requirements

Date and Time of Incident. March 10, 1975

Museum Towers EVACUATION PROCEDURE IN CASE OF FIRE

Performance Based Fire Protection With Water Mist

EXHIBIT D ATTACHMENT G - UNIT PRICING DMS-14/15-039B - SIMPLEXGRINNELL, LP FIRE SPRINKLER SYSTEM INSPECTIONS YEARS 1-5

FIRE PREVENTION STRATEGY FOR BUILDINGS IN CONSTRUCTION. Fire Department, Taipei City Government, Taipei, Taiwan, ROC 2

MORE THAN JUST FIRE PROTECTION

Following are the systems proposed as per NBC & Local Fire Authority:

ACTIVE FIRE PROTECTION SYSTEMS OVERVIEW. Fire Protection Systems

- CONSTRUCTION FIRE SAFETY STANDARDS

Fire Suppression Systems

SCHEDULE. Essential Safety Measures taken from Schedule 9 of the Building Regulations PART 1 BUILDING FIRE INTEGRITY

DISASTER MANAGEMENT PLAN 3.0 IDENTIFICATION OF MAJOR HAZARD POTENTIAL

Water mist fire suppression systems. Minifog EconAqua Water mist sprinkler systems

WORKSHEET 2-1 THE MANITOBA RESIDENTIAL OCCUPANCY FIRE RISK INDEX FIRE SAFETY PARAMETER VALUES

Fire protection documentation. CFPA-E Guideline No 13:2015 F

Active & Passive Fire Protection System. Page 1 Kalidasan S BT IN SSP-OP

Explosion Protection Engineering Principles

Date and Time of Incident. Feb. 13, 1964 Breakout at15:33 (approx.) Noticed at 15:27 Notified by emergency call. Extinguished by 21:07

Mitigating the Rural Fire Problem

Interaction of Water Extinguishing Systems and Smoke and Heat Exhaust Ventilation Systems (SHEVS)

Minifog EconAqua Water mist sprinkler systems

Approved products and systems for water mist systems and VdS 3188 for planning and installation

TYPE 1 FIRE RISK ASSESSMENT REVIEW (NO DESTRUCTIVE AUDIT)

Firefighting operations on multi-tiered vehicle stacking buildings F5-13 GD

NEW PROJECTS DOCUMENTATION FOR OCCUPATION - REGULATION 38 FIRE STRATEGIES, DRAWINGS & INFORMATION EMPLOYER S REQUIREMENTS

TUNPROTEC. Active Tunnel Fire Protection

APPLICATION FOR FIRE CERTIFICATE / FIRE CLEARANCE UNDER THE MAURITIUS FIRE AND RESCUE SERVICE ACT 2013 OFFICE USE ONLY


Statistics. Fire Departments respond to a fire every 24 seconds

False Sense of Security???

Fire Protection of Hotels. With SEM-SAFE High-Pressure Water Mist System

Owner/Operator Guide for Successful Sprinkler and Fire Pump Systems

Objective 1: Describe fire alarm systems.

Fire ground electrocution

High-pressure water mist systems and fire testing. Max Lakkonen IFAB Institute for Applied Fire Safety Research

FIRE SAFETY PLAN FOR CONSTRUCTION, RENOVATION AND DEMOLITION SITES

Branch Solution Wood based panel plants. Fire protection solutions for wood based panel plants

IMO INTERPRETATIONS OF FIRE PROTECTION-RELATED PROVISIONS OF THE HSC CODE

Ceasefire Watermist Hydrant Systems

Date and Time of Incident. Jan 28, Breakout at 00:55 (approx) Detected at 00:55 Notified by a call to the police station Extinguished by 01:50

High-Pressure Water Mist systems for the protection of shopping centres in historical city centres

Defiance College Annual Fire Safety Report for 2016

HOME FIRE SPRINKLER SYSTEMS. the future of fire safety here today

Additional Requirements for Watermist Systems Protecting High-rise Buildings

Proven Fire Fighting Efficiency for Large Transformers with High Pressure Water Mist

Use this guide to assist you when completing the Evacuation scheme application form.

(ACTIVE) FIRE PROTECTION SYSTEMS OVERVIEW. Fire Protection Systems

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT HORSEFAIR HOUSE

NEW PROJECTS DOCUMENTATION FOR OCCUPATION - REGULATION 38 FIRE STRATEGIES, DRAWINGS & INFORMATION REQUIREMENTS

THE MAURITIUS FIRE AND RESCUE SERVICE ACT. Regulations made by the Minister under sections 18, 19 and 27 of the Mauritius Fire and Rescue Service Act

Health, Safety and Wellbeing Management Arrangements. Core I Consider I Complex. Fire Safety. Health, Safety and Wellbeing Service

Kensington Aldridge Academy, London W10

Chapter 7 Fire Protection

Before Fire Outbreak. Always switch off all electrical appliances any time there is power outage or light-off.

XFlow water mist system preserves and enhances productivity at a TULIP Sausage factory in Svenstrup Denmark.

A GUIDE FOR CONDUCTING FACILITY PRE-FIRE PLANS

HOME FIRE SPRINKLER SYSTEMS. fire safety. the future of. here today

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT SPORTS CENTRE

Sprinklers in Europe known problems and misconceptions. Alan Brinson

FIRE SAFETY PLAN PART 1 BUILDING INFORMATION SECTION

RISK ASSESSMENT & EMERGENCY PREPAREDNESS PLAN

Scope of Section 2. AS vs. Application Issues. Schedules & Log- Contents. Books

GENERAL PROCEDURES TO FOLLOW IN CASE OF EMERGENCY SAFETY RULES TO PREVENT FIRES

Cost-Effective Fire Safety Management

NYU RESIDENTIAL FIRE SAFETY PLAN PART I - BUILDING INFORMATION SECTION

SAFETY. USE OF SAFETY CHECK LISTS A safety check for compliance with current regulations should be performed yearly.

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NEW BUILDINGS

Q) What should I do if the fire alarm sounds in the building? Q) What do I do if I discover a fire?

Protect your occupancy rate

Watermist Systems. Versatile, Affordable Water Mist Fire Suppression. your TRUSTED partner in fire safety

Update on European Standardization Work

TECHNICAL AND USER REQUIREMENTS FOR PERSONAL ALERT SAFETY SYSTEMS

MORE THAN JUST FIRE PROTECTION

and Sprinkler System in Resalat Tunnel of Tehran

Transcription:

HIGH PRESSURE WATER MIST SYSTEM Application: High Rise Building Bindreiter Michael London, 2018-09-19 1

Application High Rise Building Hotel & Apartment Office & Walkways Shopping mall & Lobbies Parking garage 2

Mandarin Oriental, London 06/2018 No injuries The blaze reached several floors but was quickly extinguished Cause under investigation => There s a suggestion the fire started on the roof of the Mandarin, where they have been carrying out building work. Source: http://www.newslocker.com/ 3

Torch Tower, Dubai 08/2017 Earlier fire already in 2015 Cigarette caused Dubai's Torch tower fire / Butt thrown from balcony landed on plant pots, sparking blaze 15 th floor 79 floor building / one of the tallest residential building in the world No injuries / 676 apartments Source: https://eu.usatoday.com 4

Grenfell Tower, London 06/2017 Malfunctioning Fridge-freezer on the fourth floor Rapid spread of fire attributed to the buildings exterior cladding Burned about 60 hours 72 deaths, over 70 injured 223 people escaped Source: https://en.wikipedia.org/wiki/grenfell_tower_fire 5

Risk and challenges Fast smoke radiation inside the building......causes also hard conditions for rescuer Danger of rapid fire spread...... often to fast for the fire brigade Complex evacuation scenarios......especially in heights, were it is not possible to evacuate with ladders 6

How can high pressure water mist meet these challenges?!? 7

Water mist systems High Pressure Water Mist systems...for OH- and technical areas Quick activation and Protection...... of bordering levels and rooms Approved by independent institutes... based on common EU standards 8

Benefits of water mist Lower Water consumption than conventional sprinklers... enables smaller water reservoirs, pipes and valves 3d-effect of water mist......for reaching corners and hidden fires Individual system approval...... based full scale fire tests 9

System design possibilities System types...wet system dry system pre-action system type A and B Supply stations... electrical power pack... Diesel power pack battery-back up systems 10

Water reservoirs Possibility for Full or partial storage Site installation possible Easy for retrofit installations 11

Compact Valve station Alarm valve...... for interacting with the central fire alarm system Flow Switch...... for fire brigade and fire protecting officer, to show in which floor the fire occurred Diverter valves....for deluge applications 12

Flexible Piping Reduced pipe dimensions of 12L - 42L......for riser, main line and nozzle piping Stainless Steel pipe AISI 316L......for longer lifetime Pressure level...... PN160 (160bar) All connections...... according EN ISO 8434-1 13

Nozzles head - design Nozzle head with heat-sensitive glass bulb... DKF nozzles up to 12m room heights... Sidewall nozzles... Upright nozzles...... for false ceiling protection Stainless Steel AISI 316L......for nozzles, adapters and fittings 14

Wall hydrants Fire tests in accordance to the standards of wall hydrants EN671, fire load according EN3 Easy handling Up to 80m of hose length possible Up to 4 different spraying patterns 15

Fire tests and CFD s simulation Real scale fire tests...... according common standards as well as customer requirements Proof and confirmation...... of the excellent performance of AQUASYS high pressure water mist Flexible test area...... for fast test setup and test execution 16

Research partners Research-Partners Memberships / Working Groups 17

19

References 20

Building Maakri 19/21 Tower, Tallinn (Estonia) AQUASYS fire-fighting system for 30-storey skyscrapper in the centre of Talinn. Protection of office areas, technical areas and car parks in the skyscrapper in Tallinn s Maakri Kvartal district Installation and project management by local partner 2464 nozzle heads and 11,623 m of pipeline installed in total Building height 110 m 21 21

Building Dreischeibenhaus, Düsseldorf (Germany) AQUASYS high-pressure water mist for protecting high-rise building in Düsseldorf. Installation of a water mist system on the second basement floor during general renovations Protection of the exhibition areas on the 21st, 22nd and 23rd floors at a height of approximately 70 m Project execution and installation by local partner 22 22

Building Shopping Mall, Taipei (Taiwan) High-pressure water mist system for the shopping mall. Protection of the atrium and emergency escape routes in the 16-floor shopping centre Water mist offers ideal protection against spreading flames to other areas, due to its excellent cooling properties 23 23

Building High-rise office building, Frankfurt (Germany) Water mist replacing sprinklers for modernisation of a high-rise building in Frankfurt. Surface area of 30,000 m² protected across 25 floors Protection of offices, equipment rooms and an atrium over three floors Installation performed only at weekends to avoid interrupting operations Only one pump room required to supply the entire 96-metre-high building 24 24

Protection of health, life and property means: Firefighting is responsibility 25 25