ELECTRICAL TRADES PREFERRED MANUFACTURERS LIST

Similar documents
DESIGN GUIDELINE 8.4 ELECTRICAL PREFERRED MANUFACTURERS LIST

Nov : UMHHC - ELECTRICAL PML

16995-H: UNIVERSITY OF MICHIGAN HEALTH SYTEMS PREFERRED MANUFACTURERS LIST

1.1 Preferred Manufacturers are manufacturers of products that have worked well for the University on past projects.

Border States MANUFACTURER LINE CARD. ST. CLOUD Minnesota

Border States MANUFACTURER LINE CARD. FARIBAULT Minnesota

GOVERNMENT SOLUTIONS

Large catalog of fittings, clamps, hangers, signaling products and hazardous location products.

Division 26 ELECTRICAL TABLE OF CONTENTS

Electrical Design Guidelines Table of Contents

3. Provide revised typed circuit directory in panelboards that have circuits removed.

ELECTRICAL SYSTEMS ASSESSMENT Hanover High School

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods

LIST OF PREQUALIFIED ROADWAY LIGHTING SYSTEMS & EQUIPMENT PQL 24.2 REVISED 01/03/17

A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings.

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES

A. This Section includes the following lighting control devices:

SECTION (16140) - WIRING DEVICES

electro expo

FIRE ALARM: BY OTHERS, IF REQUIRED.

Related Sections: TBD. Effective Date: January 1, 2016

FIRE ALARM: BY OTHERS, IF REQUIRED.

SECTION INTERIOR AND EXTERIOR LIGHTING FIXTURES

CONSTRUCTION PRODUCT LINE

GARCIA GALUSKA DESOUSA Consulting Engineers

MEDIUM, LOW AND CONTROL VOLTAGE CABLES

SECTION LIGHTING CONTROL DEVICES

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

TRANS ATLANTIC TRADING ENTERPRISE INC.

COHASSET, MA March 6, The following is the Electrical outline specifications, which defines the scope of work of the Electrical system.

Michigan State University DESIGN GUIDELINES. ELECTRICAL DESIGN Page 1 TABLE OF CONTENTS 1

1. Division 26 Section Electrical General Requirements. 2. Division 26 Section "Wiring Devices" for wall-box dimmers and manual light switches.

M001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings

NYC Department of Education

SECTION LIGHTING CONTROL DEVICES AND CONTROL PANELS

ELECTRICAL DESIGN GUIDELINES SECTION GUIDELINE SPECIFICATIONS-DUVAL COUNTY PUBLIC SCHOOL

TABLE OF CONTENTS CHAPTER 1 GENERAL RULES CHAPTER 2 WIRING AND PROTECTION... 51

A. Furnish and install luminaires, lamps, ballasts and in-line fuses as herein specified and shown on the Drawings.

PLUGS, RECEPTACLES, AND CONNECTORS OF THE PIN AND SLEEVE TYPE FOR HAZARDOUS LOCATIONS

You are invited to exhibit. )) # )* 2015 at the NEW Cleveland Convention Center in Cleveland, Ohio

Element D Services Electrical

All types of Rubber Hoses and related Fittings

LIGHTING CONTROL DEVICES

Page 1 of General

UBC Technical Guidelines Section Edition Interior Building Lighting Page 1 of 5

Your One Source for State and Local Government Solutions

WELCOME TO FROMM! PRODUCTS Appliances Data-Communications. FROMM OPERATES 9 SUPPLY BRANCHES IN PA Allentown Bloomsburg.

FROMMINTERNATIONAL.COM

Leviton Combination Switch And Tamper Resistant Outlet Wiring Diagram

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

C. Pigtail: Short lead used to connect a device to a branch-circuit conductor.

STATEWIDE CAREER/TECHNICAL EDUCATION COURSE ARTICULATION REVIEW MINUTES

WELCOME TO FROMM! PRODUCTS Appliances Data-Communications

Job No A. Submit the following equipment, materials and products, including all fittings and accessories:

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

DIVISION 16 BASIC MATERIALS, METHODS, AND REQUIREMENTS SECTION 16A-1

SECTION PARKING STRUCTURE LIGHTING

DIVISION 16 ELECTRICAL SYSTEMS

Chapter 1 General... 5

University Design Standard Fire Alarm Systems

CRESTRON: GREEN LIGHT NETWORK LIGHTING CONTROLS 1

ONE- AND TWO-FAMILY DWELLING ELECTRICAL CODE HANDOUT (2015 Michigan Residential Code Effective February 8, 2016)

E I Delmar Cobble MINOR ELECTRICAL DEMOLITION

.4 Do complete installation in accordance with latest Electrical Bulletins of the local inspection authority.

PLATTEVILLE MIDDLE SCHOOL

B. It is recognized that these standards are updated irregularly and lighting technology is changing rapidly.

ELECTRICAL SYMBOLS AND ABBREVIATIONS NOT ALL SYMBOLS, DEVICES OR ABBREVIATIONS MAY BE USED

1. Building wires and cables rated 600 V and less. 2. Connectors, splices, and terminations rated 600 V and less.

NYC Department of Education

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

DESIGN STANDARDS APPENDIX. Section VI. Division 16 (Revised March 3, 2008)

ELECTRICAL CURRICULA OUTLINE CORE CURRICULUM 2015

SECTION 2 NEC REFERENCES SECTION 1 LOW-VOLTAGE AND POWER- LIMITED SYSTEMS...1. CHAPTER 1 GENERAL Introduction...35

ELECTRICAL SUPPLY SOLUTIONS RESIDENTIAL COMMERCIAL INDUSTRIAL PROJECT MANAGEMENT AUTOMATION ATLANTIC / HARRIS & ROOME.

Certification All contractors shall be licensed to perform work in district area

General Supplies. General Supplies

ADDENDUM #2. Bid #18-12, Proposition 39 Interior LED Lighting Retrofit at Designated Sites

SECTION EXTERIOR LIGHTING

2017 NEC Presented by: Russ LeBlanc

LIGHTING CONTROLS

DIVISION 28 ELECTRONIC SAFETY AND SECURITY

Smart Products. Ingenious Solutions.

NYC Department of Education

A. This Section includes the following lighting control devices:

Brown University Revised June 29, 2012 Facilities Design & Construction Standards SECTION ELECTRICAL DESIGN CRITERIA

SECTION PUBLIC ADDRESS SYSTEMS

PRODUCT LINE SHEET. * AMERICAN DRYER LIVONIA, MI The most complete line of maintenance free electric hand dryers. Over 60 hand dryer models available.


NATIONAL TRAINING BOARD (ELECTRICIAN) REGULATIONS 2008 BR 54/2008 NATIONAL OCCUPATIONAL CERTIFICATION ACT :38

B. Shop Drawings: List of legends and description of materials and process used for premarking wall plates.

The following narrative outlines a conceptual electrical Scope of Work for converting the Phase 2 TRW Building to an Exhibition Hall.

Division 16 Electrical Equipment

PROFILE. industrial services rental trading

Newark, Delaware Architectural Engineering Senior Thesis Portfolio. Electrical Analysis

Michigan Chapter IAEI Annual Meeting Ann Arbor, Michigan Code Panel Questions December 5 th and 6 th, 2013

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 28 ELEC. SAFETY & SECURITY SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

13799 Commerce Parkway Richmond, British Columbia V6V 2N9 Canada Benjamin Barker, Senior Manager Accreditations

SECTION LIGHTING CONTROLS

ADVANCE ELECTRICAL MEP CONTRACTING TRADING SERVICES

TABLE OF CONTENTS CHAPTER 2 WIRING AND PROTECTION CHAPTER 1 GENERAL RULES... 19

Transcription:

ELECTRICAL TRADES PREFERRED MANUFACTURERS LIST Scope The Electrical Trades Preferred Manufacturers List identifies manufacturers and suppliers who are known to provide good quality products, meet specification and schedule requirements, provide technical support, and provide service after the sales. This list is intended to regulate product quality, standardize electrical designs, and simplify maintenance activities. It is not intended to limit competition. It is not all inclusive. It is a list of manufacturers whose products are well known to the University due to their frequent and successful use. This List shall be used by A/E s when selecting manufacturers for specification in electrical designs. A/E S SHALL SPECIFY ONLY THE LISTED MANUFACTURERS THAT MEET THEIR PROJECT S REQUIREMENTS, AND SHOULD SPECIFY A MINIMUM OF THREE MANUFACTURERS WHENEVER POSSIBLE. A/E s may specify manufacturers not on this list to satisfy project requirements, BUT ONLY AFTER OBTAINING UNIVERSITY APPROVAL IN ADVANCE. This List shall NOT be used by Contractors to justify making substitutions for products specified in the construction documents. CONTRACTORS SHALL PROVIDE THE PRODUCTS SPECIFIED IN THE CONSTRUCTION DOCUMENTS UNLESS THE UNIVERSITY APPROVES THEIR PROPOSED SUBSTITUTIONS AT THE TIME OF BID IN ACCORDANCE WITH THE PROJECT'S STANDARD GENERAL CONDITIONS. THIS LIST DOES NOT APPLY to purchases by the University Plant Department of replacement electrical products required to match or maintain existing installations. This List is revised as needed. Before using it, check the AEC Website for the latest revision. TABLE OF CONTENTS PAGE SECTION 260513 - MEDIUM, LOW & CONTROL VOLTAGE CABLES... 2 SECTION 260526 - GROUNDING & BONDING FOR ELECTRICAL... 2 SECTION 260533 - ELECTRICAL MATERIALS AND METHODS... 3 SECTION 260543 - UNDERGROUND SERVICES FOR ELECTRICAL... 4 SECTION 260800 - ELECTRICAL ACCEPTANCE TESTS... 4 SECTION 261100 - UNIT SUBSTATIONS... 5 SECTION 262000 - LOW VOLTAGE ELECTRICAL DISTRIBUTION... 7 SECTION 262726 - WIRING DEVICES... 8 SECTION 262900 - MOTOR CONTROLS... 9 SECTION 263000 - ENGINE-GENERATOR SYSTEMS... 10 SECTION 263300 - BATTERY EQUIPMENT... 10 SECTION 264100 - FACILITY LIGHTNING PROTECTION... 11 SECTION 265100 - INTERIOR LIGHTING... 11 SECTION 265600 - EXTERIOR LIGHTING... 13 SECTION 274000 - AUDIO-VIDEO SYSTEMS... 14 SECTION 275116 - PUBLIC ADDRESS & MASS NOTIFICATION SYSTEMS... 14 SECTION 275126 - ASSISTIVE LISTENING SYSTEM... 14 SECTION 275313 - CLOCK SYSTEMS... 14 SECTION 281300 - ACCESS CONTROL & MONITORING SYSTEMS... 14 SECTION 281600 - SECURITY SYSTEMS... 15 SECTION 283100 - FIRE DETECTION & ALARM SYSTEMS... 15 MARCH, 2014 PAGE 1 of 15

SECTION 260513 - MEDIUM, LOW & CONTROL VOLTAGE CABLES Cables (Medium Voltage) General Cable Kerite Okonite Prysmian Cables and Wire (600 Volts) Aetna Wire and Cable Alan Wire American Insulated Wire Cerro Wire Encore General Cable Republic Wire Rockbestos-Surprenant Service Wire Southwire United Copper Industries MC Cables (600 Volts) AFC Encore Kaf-Tech Rockbestos-Surprenant Service Wire Southwire United Copper Industries 2-Hour Fire Rated Cables (600 Volts) Pyrotenax Mineral Insulated (Type MI) by Pentair Control Cables and Wire Belden Coleman Cable Splices for Medium Voltage Cable Raychem Cable Terminations for Medium Voltage Cable Raychem SECTION 260526 - GROUNDING & BONDING FOR ELECTRICAL Ground Connections Burndy Hyground (Proper dies must be used) Cadweld Thermoweld Thomas & Betts Blackburn (Above grade only) MARCH, 2014 PAGE 2 OF 15

SECTION 260533 - ELECTRICAL MATERIALS AND METHODS Cable Trays - Center Spline and Wall Mount Types (Use only where ladder and wire basket trays cannot be used, and only with ITCS (Campus projects) or MCIT (UMHHC projects) approval) B-Line Legrand/Wiremold Mono-Systems Thomas & Betts Cable Trays - Ladder Type B-Line Chalfant Cope Globetray (GS Metals) Husky Legrand Cablofil Mono-Systems Thomas & Betts Cable Trays Wire Basket Type (Use only with ITCS (Campus projects) or MCIT (UMHHC projects) approval) B-Line Chalfant Legrand Cablofil EZTray Mono-Systems Conduits, Raceways and Accessories EMT, liquid-tight flexible metallic conduit, and/or non-liquid-tight flexible metallic conduit/raceway; plus associated accessories, fittings, junction and pull boxes, and related products Products of all manufacturers are acceptable as long as they are electro-galvanized steel, have a smooth interior, and are NRTL labeled for the application. Rigid (galvanized metal), and IMC (intermediate metal) conduits/raceway, plus associated accessories, fittings, junction and pull boxes, and related products Products of all manufacturers are acceptable, as long as they are hot-dipped galvanized steel inside and out, have a smooth interior, and are NRTL labeled for the application. Boxes shall be cast, not formed. IMC may only be used when tools specifically designed for IMC are used. PVC conduit/raceway (Type DB, Schedule 40, and Schedule 80), plus associated accessories, fittings, junction and pull boxes, and related products Products of all manufacturers are acceptable as long as they are sunlight resistant, and NRTL labeled for the application. Products from manufacturers making both the conduit and the fittings are preferred whenever possible. Fiberglass Reinforced Epoxy (FRE) conduit/raceways, accessories, fittings, and related products FRE Champion MARCH, 2014 PAGE 3 OF 15

Cord Reels Appleton Reel-O-Matic Systems Woodhead Electrical Enclosures Carlon (For use with PVC raceways) Hammond Hoffman Park Metal Rittal Fire Stop Compounds A. D. Fire Protection Systems Flame Safe Hilti Nelson STI SpecSeal 3M Company Structural Support Materials Aickinstrut (Fiberglass) B-Line Champion (Fiberglass) Hilti Powerstrut Unistrut Surface and Underfloor Wireways Carlon Legrand Evolution Floor Boxes Legrand (Wiremold) Mono-Systems Panduit SECTION 260543 - UNDERGROUND SERVICES FOR ELECTRICAL Underground Hand Holes, Junction Boxes and Pull Boxes CDR Systems Carson-Brooks Quazite SECTION 260800 - ELECTRICAL ACCEPTANCE TESTS Nationally Recognized Testing Laboratory Services CSA ETL MET Laboratories UL (Northbrook, IL) MARCH, 2014 PAGE 4 OF 15

Testing Services Bisbee Infrared Services (Penny Wilson, (517) 787-4620) Northern Electrical Testing (Lyle Detterman, (810) 689-8980) Utilities Instrumentation Services (David Wheeler, (734) 482-1450) SECTION 261100 - UNIT SUBSTATIONS Non-Current Limiting Fuses (Primary) S & C Type SM-5SS (With high interrupting capacity adapter) Type RBA-400 (With high interrupting capacity adapter) Current Limiting Fuses (Primary) Ferraz-Shawmut, Type CL-14 Type CLE Type EJO KWHR/Demand Meters Power Measurement Limited (PML) 7330 ION (With options per Master Spec 16313) 15 kv Fused and Unfused Primary Switches (5kV rated switches may only be used for 5 kv (4,160 volt) class motors) Powercon 15kV Metal Clad Switchgear and/or Circuit Breakers (5kv rated circuit breakers may only be used for 5 kv (4,160 volt) class motors) Circuit Breakers for 600-volt Class Secondary Switchgears and Switchboards Asea Brown Boveri Transformers Asea Brown Boveri MGM Olsun MARCH, 2014 PAGE 5 OF 15

Substation Assemblers (Using components from Preferred Manufacturers only) Controlled Power Corporation Electrical Product Sales Park Metal Powercon Pederson Power Products Shallbetter Addresses of above Assemblers Controlled Power Corporation 295 Wetmore Ave SE Massillon, Ohio 44646 Phone: 800 321 0414 FAX: 330 834 3201 McNaughton-McKay Electric Co. 4670 Runway Blvd, Ann Arbor, MI 48108 Phone: 734-327-6251 Fax: 734-327-6285 Service Electric Supply Co. 15424 Oakwood Drive, Romulus, MI 48174 Phone: 734-229-9100 Fax: 734-229-9101 Electrical Product Sales Dick Stone (248) 583-6100 McNaughton-McKay Electric Co. 4670 Runway Blvd, Ann Arbor, MI 48108 Phone: 734-327-6251 Fax: 734-327-6285 Olsun Electrics HEK Inc. 6083 Lafayette Ann Arbor, MI 48103 Phone: (734) 995-0900 Park Metal 19197 Sherwood Street, Detroit, MI 48234 Phone: 313-366-2200 Fax: 313-366-1540 MARCH, 2014 PAGE 6 OF 15

Powercon/Woodlyn Sales 9357 General Drive - Suite 102, Plymouth, MI 48170 Phone: 734-453-2754 Fax: 734-453-2759 Pederson Power Products 1521 Eden Gardens Drive, Fenton, MI 48430 Phone: 810-750-3032 Fax: 810-750-9557 Madison Electric Co. 3900 Jackson Rd, Ann Arbor, MI 48106 Phone: 734-665-6131 Fax: 734-665-9239 Wyandotte Electric Supply Co. 212 S. Wagner Rd, Ann Arbor, MI 48103 Phone: 734-769-6400 Fax: 734-769-7745 SECTION 262000 - LOW VOLTAGE ELECTRICAL DISTRIBUTION Bus Ducts Siemens Fuses (600 Volts and Below) Bussmann Ferraz-Shawmut Littelfuse Surge Protective Devices Current Technology -Tycor Intermatic (For protection of individual loads and receptacle panels only) L.E.A. Dynatech Leviton (For protection of individual loads and receptacle panels only) Liebert Switchboards, Panelboards and Circuit Breakers (Only with U of M Lugs - confirm on shop drawings) Industrial Electrical Manufacturing (For custom and retrofit applications only) Siemens MARCH, 2014 PAGE 7 OF 15

Time Switches Intermatic Paragon Sangamo Tork Transformers (Liquid Filled and Dry Pad-Mounted Type) Olsun Electrics Pennsylvania Pioneer Transformers (Distribution Dry Type) Acme Hammond Power Systems Hevi-Duty MGM Olsun Electrics Siemens SECTION 262726 - WIRING DEVICES Dimmer Switches Leviton (Incandescent type only) Lithonia (Incandescent and fluorescent types) Lutron (Incandescent and fluorescent types) Occupancy Sensors (Infrared, Ultrasonic, Combination Infrared/Microphonic Dual Technology and Combination Infrared/Ultrasonic Dual Technology) Leviton Lutron Sensor Switch Tork Watt Stopper Pin & Sleeve Connectors Crouse-Hinds Killark Leviton Pass & Seymour Power Poles Mono-Systems Steelcase Wiremold MARCH, 2014 PAGE 8 OF 15

120-volt, 20-ampere Receptacles (GFCI, Hospital Grade, TVSS & Child Resistant) Bryant Cooper (Arrow Hart) Leviton Pass & Seymour 120-volt, 20-ampere Receptacles and Plugs Bryant Arrow Hart (Cooper) Leviton Pass & Seymour Special Power Receptacles and Plugs Bryant Arrow Hart (Cooper) Leviton Pass & Seymour USB Charging Port Receptacles Leviton 120/277 Volt, 20-Ampere Light Switches Bryant Arrow Hart (Cooper) Leviton Pass & Seymour SECTION 262900 - MOTOR CONTROLS Capacitors for Power Factor Correction Aerovox Myron Zucker Siemens Motor Controls (MCC s, Starters, Contactors, Disc. Switches and Control Devices Allen-Bradley Siemens MARCH, 2014 PAGE 9 OF 15

Motor Starters (Electronic Soft Starter Type) Allen-Bradley Sprecher & Schuh SECTION 263000 - ENGINE-GENERATOR SYSTEMS Natural Gas Fired Engine-Generator Sets (Only those which require inlet gas pressures of 14 inches of water column or less) Caterpillar Cummins Generac Industrial Power (up through 300 kw) Kohler Olympian Automatic and Manual Transfer Switches (Open and Closed Transition Types) ASCO Cummins GE Zenith Controls Kohler Automatic Transfer Switches (Soft-Loading Type) ASCO Kohler Resistive Load Banks Avtron Sephco Simplex SECTION 263300 - BATTERY EQUIPMENT Batteries C & D Technologies Chloride Plante Enersys Johnson Controls Battery Chargers LaMarche SCI Enersys C & D Technologies Hi-Tran MARCH, 2014 PAGE 10 OF 15

Uninterruptible Power Supply Systems (Battery type) A.P.C. Best (Individual small load units only) Controlled Power Liebert MGE Mitsubishi (Totally solid-state) Toshiba Rotary UPS Systems Designed Power Solutions International (DPSI) SECTION 264100 - FACILITY LIGHTNING PROTECTION Lightning Protection Services Guardian Equipment, Novi, MI (248) 449-5200 Michigan Lightning Protection, Grand Rapids, MI (616) 453-1174 Orion Services, Wixom, MI (248) 624-2120 Sleeping Bear Lightning Protection, Maple City, MI (231) 228-4112 SECTION 265100 - INTERIOR LIGHTING Ballasts (Electronic Compact Fluorescent) Advance Smart Mate Aculite Lightolier Prescolite Ballasts (Electronic Rapid Start T-8 Fluorescent) Advance Optanium Bodine (For emergency lighting only) Osram/Sylvania Quicktronic Professional Universal AccuStart Ballasts (Electronic Dimming T-8 Fluorescent) Advance Mark X (5% dimming type) Lightolier (1% dimming type) Osram/Sylvania (10% dimming type) Emergency Power Ballasts (Electronic Rapid Start T-8 Fluorescent) Bodine (For emergency lighting only) Lithonia Ballasts (H.I.D.) Advance MagneTek Universal MARCH, 2014 PAGE 11 OF 15

Dimming Systems AMX Crestron Electronic, Inc. E.T.C. Lithonia Strand (Stage lighting only) Leviton (Small single room systems only) Lutron Emergency Lights Chloride Dual-Lite Emergi-Lite Exide Lightguard Lightalarms Lithonia Sure-Lite Exit Signs (LED) Chloride Dual-Lite Emergi-Lite Exide Lightguard Lightalarms Lithonia LSI Industries Morlite (High abuse areas) (Philips) Prescolite Sure-Lites Lamps Ecolux Philips Alto Osram/Sylvania Ecologic Venture (H.I.D. only) Lighting Fixtures (Fluorescent) Alkco (Philips) Bartco Columbia Day-Brite (Philips) Fail-Safe (Cooper) Finelite Focal Point Guth (Philips) Harris Holophane (Acuity) Keene Kenall Kirlin Lightolier (Philips) Linear Lighting Lithonia (Acuity) LSI Industries Cooper (Metalux) Peerless (Acuity) Prudential Quality (Philips) Visa Williams Zumtobel MARCH, 2014 PAGE 12 OF 15

Lighting Fixtures (H.I.D.) Best Crouse-Hinds (Cooper) Day-Brite (Philips) Fail-safe (Cooper) Guth (Philips) Harris Holophane Lighting Fixtures (Compact Fluorescent and Incandescent) Globe Gotham (Acuity) Halo Harris Kenall Kirlin Kenall Lightolier (Philips) Lithonia (Acuity) LSI Industries Lumark (Cooper) McGill Quality (Philips) SPI Lightolier (Philips) Lithonia (Acuity) LSI Industries Omega (Philips) Prescolite () Quality (Philips) Swivelier Lighting Fixtures (LED) CREE Man-D-Tec (Elevator cab and space lighting) SECTION 265600 - EXTERIOR LIGHTING Lighting Fixtures (Outdoor Building, Parking Lot and Roadway with poles by fixture supplier) BEGA (Conditional Approval) Gardco Holophane Kim () (Conditional Approval) Lithonia Hi-Tek LSI Industries Lumecon McGraw-Edison Sterner Wide-Lite (Philips) Lighting Fixtures (Outdoor Pedestrian Area with poles by fixture supplier) Lumec Photoelectric Lighting Controls Crouse-Hinds Holophane Intermatic Tork MARCH, 2014 PAGE 13 OF 15

SECTION 274000 - AUDIO-VIDEO SYSTEMS Wireless Microphone Systems Shure SECTION 275116 - PUBLIC ADDRESS & MASS NOTIFICATION SYSTEMS Public Announcement and Sound Systems Aiphone Communications Systems Atlas/Soundolier Dukane Rauland-Borg SECTION 275126 - ASSISTIVE LISTENING SYSTEM Hearing Assistance Systems Phonic Ear (for classroom applications) Sound Associates (for auditorium and theater applications) SECTION 275313 - CLOCK SYSTEMS Central Clock Systems Primex (GPS synchronous wireless) Simplex Time Recorder (through Simplex/Grinnell) Clocks (Battery Powered) Edwards Franklin Howard Miller Primex (GPS synchronous wireless) SECTION 281300 - ACCESS CONTROL & MONITORING SYSTEMS Card Access Control Systems Software House (for Campus buildings) Diebold/CBORD (for Housing facilities) Card Access Control System Designers/Installers Siemens (Mike Atzenhofer, 734 456-3800) Cabling Concepts (Tim Grady, 248 363-4200) TTI (John Rademaker, 586 864-1110) Simplex/Grinnell (John Keith, 248 427-5050) Electronic Security Systems, Inc. (Steven Maniaci, 586 756-8400) Johnson Controls MARCH, 2014 PAGE 14 OF 15

SECTION 281600 - SECURITY SYSTEMS Closed Circuit TV Systems Diamond Electric Panasonic Sensormatic Vicon Industries Security Systems ADT Security Systems Faraday Radionics (For small systems only) Simplex Time Recorder SECTION 283100 - FIRE DETECTION & ALARM SYSTEMS Fire Alarm Systems EST (through Riverside Integrated Systems only) Honeywell (UMHHC only) Simplex Time Recorder (through Simplex/Grinnell) Vesda (For smoke sampling systems only) MARCH, 2014 PAGE 15 OF 15