Zip Chillmaster Floor Mounted Chiller

Similar documents
Affix Model Number Label Here

Zip Chilltap Extra. Affix Model Number Label Here UK. Installation and Operating Instructions

Zip Domestic Chill Tap

Zenith Chill Tap. Affix Model Number Label Here 89520NZ. Installation and Operating Instructions. Filtered Ambient and Chilled drinking water

Installation and Operating Instructions. Budget priced instant boiling water heater for beverages.

Electronic Instantaneous Water Heaters Models: ES3, ES4 & ES6

Zip Hydroboil. Instant boiling water. Installation and Operating Instructions

Zip Hydroboil. Installation and Operating Instructions. Filtered instant boiling water

Zip Econoboil. Installation and Operating Instructions. Budget priced instant boiling water for canteens and kitchens.

Zip InLine. Models CEX-O & CEX-U Issued August Installation, Maintenance and User Instructions

Zip Hydroboil. Instant boiling water. Installation and Operating Instructions

ZIP InLine. Models: ES3, ES4 & ES6. Electronic Instantaneous Water Heaters. ES3, ES4 & ES6 Instructions. V1.09 Page 1 November / 2015

Zip Chilltap Extra. Affix Model Number Label Here Installation and Operating Instructions. Filtered Ambient and Chilled drinking water

Electronically Controlled Instantaneous Water Heaters Models: CEX-O & CEX-U

ZIP Varipoint III. Installation, Maintenance and User Instructions. Models VP303, VP503 VP803, VP953 direct unvented water heaters. Issued August 2008

ZIP VARIPOINT II Direct unvented water heaters.

Zip Domestic ChillTap

Zip Econoboil. On wall boiling water. Installation instructions & user manual. Model number: ,

ZIP Aquapoint III. Direct unvented water heaters Models: AP3/05, AP3/05/OB, AP3/10, AP3/10/OB, AP3/15, AP3/15/OB.

Zip Chilled Water Systems

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

The Professional s Choice

DRINKING WATERCOOLER MANUAL. Website:

ZIP HYDROCHILL High capacity chiller systems

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: READ AND SAVE THESE INSTRUCTIONS FOR THE BENEFIT OF THE USER

Installation instructions. Zip HydroTap. Affix model number label here UK

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

Zip Tudor. Affix Model Number Label Here Installation Section & Operating Heading Instructions. Single point open outlet (vented) water heaters

The Professional s Choice

Lo-Carbon T-series Window & Roof Models

Installation instructions. Zip HydroTap. Filtered boiling and chilled drinking water for commercial kitchens and tea rooms.

Owner s Manual. Installation Details Owner s Information. 80L to 400L Electric Storage Water Heaters

Operating and installation instructions

aquamanta the experts in aquatic technology

Aqua Fountain. Instructions for Use PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.

Zenith ChillTap Sparkling

Where the tap has a removable aerator on the spout exit it can be removed and cleaned periodically to maintain optimum flow performance.

BRITA. Water Filter & Chiller II. Chilled water filter. Instruction Booklet WF6100

Unvented Electric Water Heater 10/15 litre Undersink

User and Installation Instructions. Electric Auto-Fill Water Boilers EB3F, EB4F, EB6F, EB6TF IS339 ECN3539

Zip HydroTap Miniboil

Brita. Water Filter & Chiller. Instruction Booklet WF6000. Please read these instructions carefully and retain for future reference.

Streamline Undersink. Fitting Instructions and User Guide

POU(Plumbed-In) Water Dispenser User Manual

STREAMLINE OVERSINK. Fitting Instructions and User Guide _iss_05.indd 1 15/09/ :46:30

SCHWAN INSTALLATION GUIDE

Double Door - Dual Zone Wine Cooler

Autofill wall mounted water. boiler. Getting the best from your water. boiler. Please read and keep these instructions

Model pictured: ST6001

Electronically controlled instantaneous water heater. MCX: 27300, and models. Instructions for the user

Installation and Operating Instructions. ZIP UK Domestic - DOMBC2 - Filtered boiling and chilled drinking water for kitchens.

DELUXE COLLECTION Executive Filtered Water Cooler AQP-WCM-FBOT4

Electronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions

Autofill counter top water boiler

FAVORIT34502VIO. EN User Manual

STEAM WALLPAPER STRIPPER MODEL HTW5

QUICK START GUIDE SPIRIT ONE TOUCH. Please read this Quick Start Guide before using the Sparkling Water Maker.

CUBE ICEMAKER MODELS SCU25, SCU35, SCU45, SCU75, SCU95, SCU120 INSTALLATION AND SERVICE MANUAL VERSION 2

Installation Instructions. Filtered Chilled drinking water for commercial kitchens and tea rooms.

BLOW DRY & GO HAIR KIT

Zip HydroTap. Installation instructions. Filtered boiling and chilled drinking water for commercial kitchens and tea rooms.

T550i power shower pump Installation and operating instructions

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

Installation & Operating Instructions

ZIP HydroTap G4 User Manual Affix model number label here UK

Zip Econoboil 1.5 litre White Zip Econoboil 3.0 litre White Zip Econoboil 5.0 litre White Zip Econoboil 7.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

ZIP HydroTap G4 Celsius User Guide

USER INSTRUCTION MANUAL. Autofill Water Boiler

OWNER S MANUAL WARRANTY INFORMATION AND INSTALLATION INSTRUCTIONS PROFLO AND MARATHON ELECTRIC STORAGE WATER HEATERS

100 Series Maxi Internal Filters

INSTANTANEOUS ELECTRIC SHOWER

User Manual. Dishwasher ZDM17301SA ZDM17301WA

BSF60WH / BSF60SS BUILT IN ELECTRIC FAN OVEN. Instruction Manual. Please read these instructions carefully before use and retain for future reference

product safety Please read these instructions before operating the appliance and retain them for future use.

User Manual & Operating Instructions

CTA15-2 warming drawer. operating and installation instructions

illuminated filter kettle

WATER FILTER REPLACEMENT INSTRUCTIONS

Oil Panel Heater Instructions for Use

OPERATING INSTRUCTION MANUAL

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

ZIP HydroTap G4 User Guide Affix model number label here UK

ULTRASONIC HUMIDIFIER MODEL# BU6000 INSTRUCTION MANUAL

OPERATING INSTRUCTIONS FOR:

Pear Kitchen Sink Tap

aquamanta the experts in aquatic technology CH 025/050/100/ 150/200/300 NEW PHOTO Instruction Manual

User and Installation Instructions. Wall Mounted Water Boiler WMB3F/B and WMB3F/W IS435 ECN3461

T-SERIES. Wall & Panel Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

4L Instant Water Boiler Instructions for Use

Installation and Operating Instructions MODEL: MSE46W

Bar Fridge USER MANUAL MB46W

Installation instructions Zip HydroTap. Filtered boiling, chilled and sparkling drinking water for residential kitchens.

Instructions for Use Warming Drawer. Bedienungsanweisung Wärmeschublade. Notice d'utilisation Chauffe-vaisselle. Gebruiksaanwijzing Servieswarmer

illuminated jug kettle

Optimax Refrigerated Retail Merchandisers

Built-under larder fridge instruction manual RBL4. Contact Caple on or for spare parts

Academy The Straightener IM.indd 1 24/06/ :10. Instruction Manual LSHS16

Installation guide Billi B-3000 Sparkling Dual levered slimline tap option

FW422 Integrated In Column Larder Fridge Manual for Installation, Use and Maintenance

Transcription:

Installation and operating instructions Zip Chillmaster Floor Mounted Chiller CH101 Floor mounted chiller Affix model number label here 81585UK Page 1 of 12 81585UK Zip Chillmaster - Installation & operating instructions - Mar 2016 v1.05

Contents Safety information... Page 3 Technical data... Page 4 Spare parts and accessories... Page 5 Installation instructions... Page 6 Commissioning... Page 7 Operation... Page 7 Maintenance... Page 8 Filter replacement... Page 8 Cleaning... Page 9 Service... Page 9 End of life disposal... Page 10 Warranty information... Page 11 Contact details... Page 12 81585UK Zip Chillmaster - Installation & operating instructions - Mar 2016 v1.05 Page 2 of 12

Safety information Please read all installation requirements, installation procedures and precautions before installing a Zip Chillmaster. Never attempt to install a Zip Chillmaster without reading all of the applicable instructions. Installation, commissioning and maintenance of this appliance must only be carried out by a competent installer who will then be responsible for adhering to all relevant standards and regulations. Appliance to be wired to a double pole switched fused spur with a minimum breaking capacity of 13 amps. Installation must comply with current IEE regulations and any Local Authority requirements. This appliance must be earthed. Check that the power supply is switched off prior to electrical connection. The appliance, its wiring and piping must not be modified in any way. In case of malfunction isolate the power supply immediately. In case of leaks also isolate the water supply. Repairs must only be carried out by Zip Water UK or an authorised Zip service engineer. If the power supply cable is damaged it must be replaced by a Zip service engineer or a qualified electrician. The cross sectional area of the power supply cable must be appropriate for the power rating and location of the appliance. The power supply cable must be adequately secured. Check that the power supply is switched off prior to electrical connection. Do not remove the appliance cover under any circumstances without first isolating the appliance from the power supply. This appliance must not be used by any person (including children) with limited physical, sensorial or mental abilities or failing experience and / or knowledge unless they are supervised by a person responsible for their safety or received instructions about how to use the appliance. Children should be supervised in order to make sure that they do not play with the appliance. The appliance must only be used when correctly installed and in perfect working order. This product is approved to the LVD and EMC directives and CE endorsed. This product has been examined, tested and found when correctly fitted to comply with the requirements of the United Kingdom Water Regulations / Byelaws (Scotland). The products are listed under the WRAS (Water Regulations Advisory Scheme) Water Fittings and Materials Directory. Zip Water UK cannot be held liable for any damages caused by failure to observe these instructions. Please leave these instructions with the end user after installation. Page 3 of 12 81585UK Zip Chillmaster - Installation & operating instructions - Mar 2016 v1.05

Technical data Upright water chiller with heavy duty lever-action tap. Delivers 140 glasses per hour of chilled filtered water within the operating range of 5 ºC to 10 ºC. 15 mm water connections. Adjustable levelling feet. Maximum water pressure: 0.7 MPa (7 bar). Minimum water pressure: 0.17 MPa (1.7 bar). Power Supply: 1/N/PE 240 V ~ Power Rating: 300 W. Rated Current: 1.5 A Chiller type: Fan cooled condenser with a compressor rated at 200 W. Stainless steel water bowl and outer case. Storage capacity: Nominal 1.8 litre. Output capacity: Rated at 140 glasses per hour at <10 ºC. Refrigerant type: Non-toxic R134A. Tap: Chrome plated brass, heavy duty, lever action tap with swivel head. Outer case: Brushed finish stainless steel case with front access panel. Filtration type: Submicron filtration. Dimensions: Height: 915mm, Width: 350mm, Depth: 350mm 81585UK Zip Chillmaster - Installation & operating instructions - Mar 2016 v1.05 Page 4 of 12

Spare parts and accessories 1 Spare parts Item Part No. Description 1 SP99249 Heavy duty self return ChillTap 2 SP7036 Thermostat SP90019 ZT502 Fan motor kit (not shown) Sub micron filter Accessories 2 Item Part No. Description Optional ZG500* BREEAM installation kit Optional ZI001 Drinking bubbler Optional HE45004** Water block (water shut down system) Optional ZD003 Waste water dish Optional ZE001 Disposable cup dispenser Optional AQ3 Pressure reducer set at 0.35MPa (3.5 bar) * The Optional ZG500 Installation Kit allows the Zip Chillmaster to be installed fully in accordance with the requirements of BREEAM Health & Wellbeing Credit HEA 16 (Drinking Water) by enabling the chiller to be securely attached to both the wall and the floor as well as providing security covers to protect the water and electrical connections. *ZG500 BREEAM Kit ** The recommended optional Water Block is ideal for limiting potential leakage and resulting water damage from water chillers and their supply pipe work which are subject to mains water pressure. It is easily installed via standard 3/4 BSP water connection and can be pre-set from 5 to 50 litres. **HE45004 Water Block The Water Block also incorporates a non-return valve. Page 5 of 12 81585UK Zip Chillmaster - Installation & operating instructions - Mar 2016 v1.05

Installation instructions The Chillmaster is an indoor appliance and must not be exposed to the elements. Installed height will vary due to adjustable feet. Place the unit on a level floor and screw the feet in or out as appropriate to make the unit level and steady. Leave at least a 50 mm gap between the sides of the unit and any walls, to allow air flow through the vents. The rear of the unit can be flush mounted against the surface of a wall if the plumbing permits. 58mm 1/2 BSP female cold inlet Drain Inlet 167mm 915mm 520mm 770mm Electrical connection 12-25mm 350mm 350mm 81585UK Zip Chillmaster - Installation & operating instructions - Mar 2016 v1.05 Page 6 of 12

Installation instructions continued Plumbing. NOTE If the mains water pressure is greater than 0.7 MPa (7 bar) a pressure reducer will be required. AQ3 is available as an option (see options table page 5). Connect a cold water supply to the 1/2 BSP female inlet at the back of the chiller where shown in the diagram. Connect a drain to the 40 mm PVC female outlet at the back. Alternatively, there are pre-punched holes in the base of the Chillmaster for bottom access to plumbing services. This appliance incorporates backflow protection. No further backflow protection is required for connection to the water supply. Electrical Electrical connection is to be made by a Zip Service Engineer or a qualified electrician. Installation must comply with current IEE regulations and any Local Authority requirements. Appliance to be wired to a double pole switched fused spur with a minimum breaking capacity of 13 amps. The supply flex should be minimum 3 core 0.75mm 2 and securely fixed to the clamp provided within the unit behind the front cover. This appliance must be earthed. DO NOT turn the electric supply ON until the unit is purged. If not yet installed, fit the filter change reminder light batteries to the circuit board matching the polarity. The batteries are located on the inside of the front cover. To remove, undo the the two security fittings at the base of the cover with the supplied key. Commissioning Purge the air from the unit when the plumbing connections are complete by turning ON the water supply and operating the tap until the water flows through without spluttering. Check for leaks. Repair any found. Operation Operating the Tap Chilled water is dispensed (within the rated capacity) by rotating the spring loaded lever. In the upright position the tap is off. When the lever is rotated forward water will flow until the lever is released. When released, the lever will spring back to the upright (off) position. Operating the Bubbler PRESS ROTATE FORWARD Chilled water is obtained momentarily by pressing the bubbler button. Water will stop flowing once the button is released. The water is chilled by a refrigeration unit fitted within the cabinet stand, under the basin. Page 7 of 12 81585UK Zip Chillmaster - Installation & operating instructions - Mar 2016 v1.05

Maintenance Filter battery replacement Your Zip Chillmaster has a filter replacement reminder light that shows through the front label. The 2 AAA reminder light batteries (located on the inside of the front cover) must be replaced at the same time as the filter. To remove the cover, undo the two security fittings at the base of the cover with the supplied key. Normal operation is for the light to flash once per minute. When the filter cartridge is due for replacement, the indicating light will flash once per second. Filter Light Filter replacement Removing the filter Remove Filter 1. Rotate 2. Pull For safe operation, the filter cartridge should be replaced at least every 6-12 months, or earlier if you notice a persistent reduction in water pressure from the tap or an unpleasant taste or odour in the water. For safe operation, thoroughly flush the water through after periods of non-use longer than 12 hours. Not changing the filter cartridges when required may cause the water to become biologically unsafe. Use only a Zip filter to match the one used in your system product (see Spare parts and accessories page 5). The filter cartridge can be obtained through plumbing suppliers or direct from Zip. The installation date should be written on the filter cartridge. No special tools or skills are required to install the filter cartridge. Turn off the mains electricity supply. Locate the filter in the under-sink cupboard. Grasp the filter cartridge firmly and twist it horizontally a quarter turn clockwise until it stops. Some water will be expelled from the filter head during the replacement process so it is important to cover the area below the filter, especially the electrical connections, with a cloth or towel to catch and mop up the waste water. Ensure that the electrical connections remain dry at all times. Gently ease the cartridge downwards to detach it from the filter head, then pull it out and discard responsibly. Take care not to tip it up once free as water may spill out. 81585UK Zip Chillmaster - Installation & operating instructions - Mar 2016 v1.05 Page 8 of 12

Filter replacement continued Inserting the new filter Write the date of replacement on the new filter cartridge label. Remove the protective plastic cap. The insertion method is the opposite to the removal method. Align the tabs of the replacement cartridge with the filter head and insert it up into the filter head. Turn the replacement cartridge a quarter turn anti-clockwise until it stops and locks into position. When the filter replacement has been completed purge the system of trapped air by dispensing water from the tap until it flows without any further spluttering. Run the water for at least 2 minutes more to complete the purge. 1. Insert 2. Rotate Cleaning Cleaning Never use strong, corrosive or abrasive cleaning materials. Wipe clean the outer surfaces with a sponge or a soft cloth using a mild soap and water. The basin is made of stainless steel that will show scratches if an abrasive cleaning product is used. The louvres on the sides need to be kept free of dust and lint to permit free flow of air throughout the vents. They should be checked regularly, at least monthly, and dusted or vacuumed. Service There are no user serviceable parts but there are dangerous voltages present within the appliance. All service work must only be carried out by suitably qualified and experience service personnel. Before calling for service, check that both the water and electricity supplies are turned ON and functional. Call an electrician, a plumber, or Zip customer service for assistance, service, spare parts, or enquiries. Zip customer service 0845 600 5005 or 0345 6 005 005. Page 9 of 12 81585UK Zip Chillmaster - Installation & operating instructions - Mar 2016 v1.05

End of life disposal The use of this crossed out wheeled bin logo indicates that this product needs to be disposed of separately to any other household waste. Within each of the European Union member countries, provisions have been made for the collection and recycling of unwanted electrical and electronic equipment. In order to preserve our environment we ask that you dispose of this product correctly. Please contact Zip Customer Service for advice on 0845 6 005 005 or 0345 6 005 005. 81585UK Zip Chillmaster - Installation & operating instructions - Mar 2016 v1.05 Page 10 of 12

Warranty The Zip appliance you have chosen is precision-built from the finest materials available and should give many years of trouble free service. Certain warranties may be implied by law into your contract with Zip. The warranty provided below is additional to these implied warranties and nothing set out below shall limit your statutory rights or rights at law. Zip Water UK warrants that, should any part fail within 12 calendar months of installation, that part will be repaired or replaced free of charge by Zip or its Distributor or Service Provider, except as set out below, provided the appliance is installed and used strictly in accordance with the instructions supplied, and that failure is not due to accident, misuse, abuse, unsuitable water conditions, or to any alteration, modification or repair by any party not expressly nominated by Zip. No costs are payable by the customer other than any mileage or travelling-time charges incurred by a Zip Service Provider or the cost of removal, cartage and re-installation of any component of the appliance if it needs to be returned for repair to Zip or its Distributor. This warranty does not cover damage resulting from non-operation of the appliance or consequential damage to any other goods, furnishings or property. No warranty applies to the life of any filtration cartridge installed with the appliance as cartridge life may vary according to water quality and the rate of water consumption. Zip does not exclude, restrict or modify any liability that cannot be excluded, restricted or modified or which cannot, except to a limited extent, be excluded, restricted or modified as between the owner or user and Zip under the laws applicable. Furthermore, this warranty does not displace any statutory warranty, but, to the extent to which Zip is entitled to do so, the liability of Zip under any statutory warranty will be limited at Zip s option to the replacement of the appliance or supply of equivalent appliance, the payment of the cost of replacing the appliance or acquiring an equivalent appliance, or the payment of the cost of having the appliance repaired or the repair of the appliance. Registering Your Purchase Registering your Zip installation on the Zip website may help to establish date of installation should it become necessary to service the appliance under terms of the Zip warranty. To register your installation go to www.zipwater.com/uk and look under the heading Warranty. Page 11 of 12 81585UK Zip Chillmaster - Installation & operating instructions - Mar 2016 v1.05

Contact Details Zip Water UK 14 Bertie Ward Way, Dereham, Norfolk, NR19 1TE Telephone 0845 6005 005 Mobile 0345 6005 005 Web www.zipwater.com/uk e-mail info@zipindustries.co.uk 81585UK Zip Chillmaster - Installation & operating instructions - Mar 2016 v1.05 Page 12 of 12