Submittal S-NV-200-LF-M DIGITAL TEMPERATURE CONTROL STATION. Valve assembly is ASSE 1017 Certified. Valve assembly is cupc Certified

Similar documents
Submittal S-NV-150-LF-M November, 2018 MEGATRON MODEL NV-150-LF DIGITAL TEMPERATURE CONTROL STATION

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION MEGATRON MODEL 10NB-LF 4 HOT & COLD INLETS 4 MIXED OUTLET 2 RETURN PIPING

WATER TEMPERATURE CONTROL SYSTEMS

INSTALLATION ADJUSTMENT SERVICE

DigiTemp. Digital Water Tempering System. PVI.com

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

ADMS. AERCO Digital Mixing Station. AERCO.com

MODEL 270-LF ECO-MIX THERMOSTATIC MIXING LEAD FREE THERMOSTATIC POINT OF USE MIXING VALVE. Submittal Data Sheet S-827-LF February 2013

COMPLETE WATER TEMPERATURE CONTROL SYSTEM

MODEL TA. TA-SB 117.5mm mm HOT INLET. TA mm mm mm mm

MEGATRON MODEL 2, 3, 4, and 5

INSTALLATION ADJUSTMENT SERVICE

TA-300, TA-300-LF, TA-350, TA-350-LF

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20, TM-20-LF (As furnished with models TM-554, TM-356, TM-356-W/HA)

SECTION DOMESTIC WATER PIPING SPECIALTIES

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20* (As furnished with models TM-554, TM-356, TM-356-W/HA Valve is ASSE 1017 listed

INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-981 & LV-982

HL45, HL80 Thermostatic High-Low Valves

Automatic Temperature Controller (ATC)

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

EZT Series Integra Med Touch Area Alarm & Zone Valve Box with EZ Backfeed

TMV45 & TMV80 Standard Thermostatic Mixing Valves

5 (34) 10 (69) 45 (170) 64 (242) 65 (246) 92 (348) 90 (341) 127 (481) 85 (322) (227) 80 (303) 113 (428) 148 (560) 105 (397) 141 (534) 100 (379)

LMS-188-4P-BMS 4 POINT DIGITAL MONITOR/ALARM WITH PROTOCOL CONVERTER OPERATING INSTRUCTIONS

HYDRONIC TEMPERING VALVES. Part No. High Temp F. Part No. Low Temp F

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

OUTLET HOT INLET COLD INLET INSTALLATION

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM TM-500, TM-550

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet.

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION ADJUSTMENT SERVICE NEXT-GENERATION MANIFOLD SYSTEMS TM-520B-LF, TM-820B-LF, TM-920B-LF, TM-1520B-LF

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF

Components only, Unassembled, 4" Metal Control Box. (Order separately) 860T T T T158

IntelliStation. The Smart Mixing & Recirculation System. For Domestic Hot Water in Commercial and Institutional Facilities. PowersControls.

water source / fan coils

MEGATRON MODEL 2NB-LF, 3NB-LF, 4NB-LF, 5NB-LF NEXT GENERATION MANIFOLD SYSTEMS TM-520B-LF, 820B-LF, 920B-LF, 1520B-LF

DIGITAL-FLO SEMI-INSTANTANEOUS VERTICAL HOT WATER

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Model SFMV Series. Lead-Free Supply Fixtures Based On The MV17 Master Mixing Valves

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Circuit SolverTM THERMOSTATIC RECIRCULATION VALVE FOR DOMESTIC HOT WATER SYSTEMS.

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Installation S

Installation S

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM * TM-500A, TM-550A

SECTION WATER HEATERS

CLASSIC HIGH LOW MANIFOLD SYSTEMS

DOMESTIC OUTLET. kg/cm 2 11 psi LEONARD LEONARD -10 C F LEONARD R THERMOSTATIC LEONARD LEONARD C F C F 60 COLD INLET HOT INLET

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

water to water heat pumps

Project Name: Location: Engineer: Contractor: I. GENERAL

COMMON WATERSIDE ECONOMIZER APPLICATIONS:

GOLD Plus 30/40/60/80

2016 CDM Smith All Rights Reserved July 2016 SECTION PLUMBING - EQUIPMENT

BRADLEY CORPORATION DOMESTIC WATER PIPING SPECIALTIES Page 1 of 9

Packaged Semi-Instantaneous Steam Fired Water Heater

Installation S

Installation S

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

Product Manual. Companion Water Heater. Maintenance Parts. Installation Startup. for WM97+ Gas-Fired Boilers

Installation S HL2X2 High Capacity Manifold System. Table of Contents Rev. B; ECN Bradley Page 1 of 8 11/10/2014

INSTALLATION ADJUSTMENT SERVICE TM-1520A-DT, TM-2020A-DT PARALLEL SYSTEMS

RQE Series Temperature Controllers

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

INSTALLATION ADJUSTMENT SERVICE MEGATRON MODEL 8N-LF. Valve assemblies are ASSE 1017 listed

Owner s Manual Therma-Stor II Heat Recovery System

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE TM-200 (NEW STYLE) TMS-200 (VALVE ONLY)

Hubbell NX500 High Efficiency Gas Condensing Water Heater

.03 ATMOSPHERIC DEAERATOR

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-420A Valve assemblies are ASSE 1017 listed

30 R -10 C F H C INSTALLATION. Maximum Operating Pressure 125PSI (860 KPA) for Hot and Cold Water. CAUTION

LMS-188-4P 4 POINT DIGITAL MONITOR/ALARM OPERATING INSTRUCTIONS

CL64T INDUSTRIAL TOTE WASHER

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-420A Valve assemblies are ASSE 1017 listed

Revitalize Building Mechanical Systems (4619)

Addendum H to Brute LX 1295A Document 1372

PRE-ASSEMBLED RADIANT CONTROL PANEL INSTALLATION MANUAL

INSTALLATION & TESTING MANUAL

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

Remote Alarm Monitoring Alarm monitoring includes Global Remote Alarm Relay. Capabilities independent port can be used

Automatic Circulating Water Heaters

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL FOR

WATER HEATING & WATER TEMPERATURE CONTROL DIGITAL & FEED-FORWARD

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

ECO1ZN3P, ECO2ZN4P ECO

SPEAKMAN SAFETY PRODUCTS Installation, Maintenance & Operation Instructions SEF-18XY, EYESAVER FAUCET with SENSORFLOW, Battery or AC POWER

WF2613 Classic Corner Washfountain with 9" Deep Bowl

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-520, TM-820, TM-920, TM-1520A TM-520-LF TM-820-LF, TM-920-LF, TM-1520A-LF

Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide

Transcription:

! APPROXIMATE DIMENSIONS A = 3-11 B = 3-9 C = 4-1/2 D = 1-1 *Image not to scale* WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer. For more information, go to www.p65warnings.ca.gov Submittal S-NV-200-LF-M MEGATRON MODEL NV-200-LF November, 2018 DIGITAL TEMPERATURE CONTROL STATION Digital Mixing Valve with 2 inlet ball and check valves, 2 Outlet with ball valve and integral RTD Sensor Additional Integral RTD Sensors for three critical measurement points; Inlet Hot Water, Inlet Cold Water, and Return Water temperature Additional Integral Pressure Sensors for two critical measurement points; Inlet Hot Water and Inlet Cold Water 2" inlets, 2" outlet (50.8mm X 50.8mm) 0.25 GPM** (0.95 L/min) minimum flow capacity Maximum operating pressure: 125 PSIG (860KPA) Controls water temperature to ± 2 F in accordance with ASSE 1017 Controls water temperature to ± 2 F at the NV-200-LF during times of low/no system demand Automatic Hot/ Cold Water shutoff upon cold/ hot water inlet supply failure User programmable for on-site configuration, high-temperature sanitization mode, and high/ low temperature alarm User adjustable settings at the controller or remotely through a Building Automation System/ Building Management System Six standard BMS Protocol Languages on-board communication Cloud based data logging and monitoring capabilities User programmable set point range between 65 F and 180 F Options to display 4 additional temperature inputs, 1 flow channel input, & 1 configurable flow or pressure UL Listed 120V plug in power supply with 6 cord Option for Backup Uninterruptable Power Supply in the event of primary power loss w/ approx. two hours run time Factory assembled and tested NOTE: Flow rates will vary depending on existing field conditions. Leonard Valve Company always recommends using CASPAK sizing software for proper valve sizing and model number applications. Product is non-cancellable and non-returnable from date from order with factory. Signed submittal required with purchase order. Engineer's Approval Job # Arch/Eng. Contractor Note: The models shown represent Leonard Products which are believed to be equivalent in type and function to items specified. Leonard Valve Company is not responsible for errors or omissions due to differences in interpretations of information provided. Valve assembly is compliant with Low-Lead requirements of wetted surface area containing less than 0.25% lead by weight. All other fittings and components, the sum total of which comprise the wetted surface of this product contains less than one quarter of one percent of lead by weight. **NOTE: The valve will maintain temperature with 0.25 GPM flow from the domestic hot water loop when properly installed near the hot water source with a continuously operating recirculation pump. *Factory supplied circulator standard with B&G PL-55B. CAUTION! See PageAll 4 for thermostatic Piping Method water Detail mixing & valves Flowhave Capacity limitations. Chart, They Page will 5 NOT for Options provide the desired accuracy outside of their flow capacity range. Consult the Flow Capacity Chart and DO NOT OVERSIZE. Minimum flow must be no less than as indicated. Valve assembly is ASSE 1017 Certified Valve assembly is cupc Certified Valve electronics are UL Certified

REQUIRED INFORMATION WHEN ORDERING Circulator requirements must be specified by the Engineer, lines 1 & 2 are REQUIRED, line 3 is optional 1. Circulated flow required, (not mixing valve flow) 2. Head required without Megatron Assembly 3. Standard pump is B&G PL-55B, if another manufacturer is preferred, please specify, but note the any change from standard pump will result in a PRICE INCREASE LEONARD MEGATRON MODEL NV-200-LF Complete Digital Water Temperature Control Station to include: 2 inlet connections (copper tube) 2 outlet connection (copper tube) Leonard Nucleus Digitally Controlled Mixing Valve with simple two line LED display and plumbing dashboard diagram status indicator LED s Leonard Factory check valves and full port ball valves on inlet piping Outlet Test Connection with ball valve and 3/4 connection Full port ball valve mounted downstream of test connection on mixed water outlet of the system Subassembly with 1-1/4 return piping, Aquastat, circulator, full port ball valves and check valves Aquastat with temperature differential of 5 to 30 F (3 to 17 C) Two GFCI* switches. The circulator GFCI switch will be used to turn the circulator on or off for setup *Ground Fault Connection Interrupter* System mounted on 2 separate struts, galvanized. Struts shall be assembled with three hole flat angle plate on corners, four hole tee plates or two hole flat plate connectors on all other support pieces using 3/8 grip lock nuts and 3/8 x 1 hex head cap screws, washers and lock washers All electrical connections to be completed by Electrical Contractor 2

LEONARD MEGATRON MODEL NV200-LF DIGITAL TEMPERATURE CONTROL STATION *Image not to scale* 10 10 1 2 7 8 2 4 6 2 3 5 9 5 6 1. NUCLEUS VALVE AND CONTROLS 2. 2" FULL PORT 3. 2" 4. 3/4" TEST CONNECTION 5. 1-1/4" FULL PORT 6. 1-1/4" 7. AQUASTAT 8. CIRCULATOR 9. BOILER DRAIN CONNECTION 10. GFCI ELECTRICAL OUTLET NUCLEUS VALVE CONTROL BOX 3

MEGATRON MODEL NV-200-LF 1-1/4 RETURN PIPING METHOD W *Image not to scale* HIGH TEMPERATURE FIXTURES TEMPERED WATER FIXTURES RECOMMENDED HOT WATER BYPASS CIRCULATOR AQUASTAT HEAT TRAP MIN 24" CIRCULATOR HOT WATER SOURCE COLD WATER SUPPLY MINIMUM MEGATRON MODEL NV-200-LF Flow Capacity FLOW 5 10 15 20 (GPM) (l/min).3.7.97 1.4 1.7 PRESSURE DROP 25 30 2.1 35 2.4 40 2.8 45 3.1 50 3.4 PSI BAR 0.25** (.95) 80 115 130 303 435 492 147 556 165 625 173 655 189 715 198 750 215 814 226 856 GPM l/min NOTE: Flowrates will vary depending on existing field conditions. Leonard Valve Company always recommends using CASPAK sizing software for proper valve sizing and model number applications. 4

OPTIONS LC Megatron furnished without a circulator. FM Megatron with 3 legs, 3 ½ feet and 45 degree braces front and back for mounting to floor in center of room. FS Megatron with separate legs to floor to support the unit without hangers. 2 PUMPS R Redundant recirculation pump 2 PUMPS H High temperature loop recirculation pump HBP High temperature by-pass flush with locking ball valve OPTIONS * LC Less circulator FM Floor mount FS Free standing 2PUMPR-Redundant recirculator pump 2PUMPH-High temperature loop recirculator pump HBP- High temperature by-pass flush PIPING OPTIONS * RP 1-1/2 1-1/2 Return line size (W) RP 2 2 Return line size (W) * Any option chosen will alter pricing 2018 Leonard Valve Company Printed in USA 5 WEB: http://www.leonardvalve.com

OPTIONS AND ACCESSORIES *ANY OPTION CHOSEN WILL ALTER PRICING CONTACT LEONARD VALVE COMPANY FACTORY* RDU Remote Display Unit SCO Solenoid Control Option BPS Backup Power Supply Unit LC Less Circulator DB Daughter Board RDU Remote Display Unit Activated when Nucleus relay switch is in alarm mode Alarm Delay Module with yellow, red, green LED indicators UL listed 100-240VAC power supply with 10 cord Unit includes 9V NiMH rechargeable battery back up User selectable timer VELCRO mounting strips provided Recommended maximum distance from controller to RDU is 500 SCO Solenoid Control Option For use with Nucleus relay switch Galvanized box with dimensions 6 Wide x 6 High x 4 Deep Solid state relay and terminal strip mounted and wired UL listed 100-240VAC power supply with 10 cord For either normally open or normally closed operation For use with 24-240 VAC solenoids only BPS Backup Power Supply Uninterruptable Power Supply with up to 2 hours run time in case of primary power loss DB Daughter Board Option To display up to 4 additional temperature inputs, 1 flow channel input, and 1 configurable flow or pressure input channel. Choose one or more below LC Less Circulator Option Assembly Shipped without circulator T5 T6 T7 T8 F1 F2 or P3 *ANY OPTION CHOSEN WILL ALTER PRICING CONTACT LEONARD VALVE COMPANY FACTORY* Note: Leonard Valve Company reserves the right of product, or design modifications without notice or obligation. 2018 Leonard Valve Company Printed in USA 6