intarpack refrigeration centrals intarpack intarpack centrifugal axial self-contained refrigeration centrals MDV / BDV / MDE / BDE series

Similar documents
intarpack refrigeration centrals intarpack intarpack centrifugal axial self-contained refrigeration centrals MDV / BDV / MDE / BDE series

intarpack intarpack axial MDE / BDE series air-cooled condensing units High power in the smallest space. Tropicalised design for ambient temperature

Condensing units with inbuilt control board, to be connected to refrigerated cabinets and special evaporating units...

Process glycol chillers

50VZ (40PZ/38VZ) Vertical Air-Cooled Split-System Cooling Units. Nominal cooling capacity kw

CHAPTER 6 CONDENSING UNITS

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

Roof top SPACE RPC 450Z R407C M011


CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

condenciat cl Condensing units Outdoor condensing unit Variable speed propeller fan Use Description for direct expansion applications

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

500 EX Fusion Compressor Series

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Chiller units and air-water heat pumps RANGE OPERATING LIMITS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Refrigeration Units Product catalogue & selection guide 2011 edition

Roof top SPACE RPC 315Z R407C MA00

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Technical Information

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

High temperature air-to-water heat pumps

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Klimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

60 Hz. Catalogue_2016 REFRIGERATION UNITS. - Commercial Range -

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

Compact and silent Scroll compressors All-season operation

Application Engineering

LZT High efficiency air to water heat pumps with E.V.I. compressors

MAGISTER. Compact and attractive design Energy savings with EC motor and self-regulating control. Easy to install. Use. Chilled water operation

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

Precision air handling cabinets Ciatronic MICRO/EXPAIR

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

Technical Catalogue. Multi-Scroll Air-Cooled Liquid Chillers. Nominal cooling capacity: kw 50 Hz

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

Aquaflair TRAC-TRAF-TRAH

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

Mechanical Systems Mechanical Systems

VariCool VAV Engineering Guide

Air cooled water chillers

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

GHE Dehumidifiers for radiant cooling systems with heat recovery

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Application guide Installation, operating and maintenance manual AIRCUBE - KSCM/KSHM. Providing indoor climate comfort

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

Hi-Pres. Self Contained A/C Unit HI-PRES MARINE & OFFSHORE

PURESTREAM CHILL-CUBE TM BY FRIULAIR

PRODUCT GUIDE

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

Air cooled industrial chillers

Ultimate energy saving technology

Aquair BCP. Pool air handling units. Electronic Control Optimized energy consumption DESCRIPTION PRINCIPLE SCHEMES RANGE OPERATING LIMITS

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

Mechanical Heat Pump R515

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

intarpack chiller refrigeration chillers MWE / BWE series

Thomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.

CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY

Commercial High-Efficiency Condensing Units

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB

Energy Use in Refrigeration Systems

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

DANFOSS OPTYMA PLUS INVERTER UNITS

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

LZT High efficiency air to water heat pumps with E.V.I. compressors

30GT FLOTRONIC AIR-COOLED CHILLERS

MAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water.

Motor-driven condensing units MTE MTE R-410A

Personalized comfort for offices and shopping malls RANGE OPERATING LIMITS

Pressure Enthalpy Charts

MAC N-407 Air-Cooled Chiller

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

LZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES

RMA AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

air systems Roomtop RTC-RTH 15 to 30 - L

Next MTR kw. technicalcatalogue. Air conditioners for Metrology Labs with upflow air delivery T_NXTMTR_0511_GB

Chapter-8 Capacity Control of Refrigeration Systems

Transcription:

selfcontained refrigeration centrals MDV / BDV / MDE / BDE series refrigeration centrals Selfcontained aircooled refrigeration centrals, designed for indoor or outdoor installation, with minimum space needs. centrals range cors compressor capacity from 4 to 60 HP at positi and negati temperature, in two different constructions: aircooled centrals ha been designed for indoor installation at an engine room. They feature medium pressure motorfans to duct outdoors the hot condensing air flow. High power in small place. Tropicalised design for ambient temperature up to. Rack of hermetic reciprocating or scroll compressors with noise insulation. Minimum maintenance needs, with simple access through removable panels. axial axial aircooled centrals ha been deloped for outdoor installation. Each model has been designed to operate under extreme ambient conditions, featuring acoustic insulated components for lower noise lel.

innovati refrigeration solutions High reliability compressors DanfossManeurop hermetic reciprocating and scroll compressors are known for their sturdy construction and high reliability operation, and, by being cooled by the refrigerant, they allow a ry efficient noise insulation. Description Features Selfcontained aircooled refrigeration centrals, from 1 to 3 compressors, for positi and negati temperature applications, featuring control board and electronic regulation (depending on the rsion) with control of condensing temperature. R404A refrigerant. Hermetic reciprocating or scroll compressors, noise insulated, with discharge muffler (for reciprocating compressor models), mounted on shock absorbers, internal klixon and crankcase heater. Condenser coil made in copper pipes and aluminium fins. Mediumpressure motorfans for rtical or horizontal air discharge for a ducted outlet of condensing hot air. Proportional control of condensation temperature by fan speed control. Refrigeration circuit equipped with high and low pressure switches, ceramic dehydratant filter, liquid receir and sight glass. Full control and power panel, with differential switch for each compressor (in 2 or more compressors units) and for each motorfan (in 2 motorfans units), MCB switch for compressor/s and motorfan/s, and electronic regulation (depending on the rsion). Copeland negati temperature scroll compressors with vapour injection system, provide a higher performance of up to 25% related to standard compressors. Centrifugal motorfan aircooled centrals include motorfans for a ducted outlet of condenser s hot air. Available static pressure (mmwc) 30 20 1 2 As an option system for cooling capacity modulation. Oil separator (already included for 2 scroll compressors negati temperature units). Anticorrosion coil coating. Backflow damper in fan outlet. Protection system for voltage drop and phase failure. 10 2000 4000 6000 8000 10000 Air flow (m³/h) Series 5: Cur 1 Series 6: Cur 2 Series 8: Cur 2 Very compact design with 800 mm maximum width Electric board with differential switch (depending on the model) and MCB switch Cooling s on the left side New generation electronic regulation (depending on the rsion) Centrifugal motorfan Tropicalised condensing coil MDVCVF and BDVCVF rsion (featuring cooling capacity modulation) aircooled centrals can be equipped with the system (Variable Refrigerant Capacity),, which adapts the refrigerant flow to the demand of the evaporating units, keeping constant the pressure in suction line. system is composed by a set of pressure and temperature regulation vals able to progressily change compressor cooling capacity from 100% to 10% of its nominal capacity, while reducing the absorbed electrical power. P abs Discharge muffler Noise insulated hermetic compressor 5% 55% P frig 100%

refrigeration centrals MDV / BDV series Applications aircooled centrals ha been designed to centralize the cooling production of a set of evaporating units. They ha been deloped to be installed indoors at an engine room and extracting outdoors the condensation hot air through ducts. Vertical discharge assembly (standard) As standard, motorfans are assembled for rtical air outlet with by front and by side maintenance access. cold room +2 ºC process room +12 ºC refrigerated showcase +2 ºC vitrines murales des fruits and légumes +7ºC Condensig hot air extraction duct By front maintenance access refrigerated packaged food display rack +2 ºC Cooling >500 mm Horizontal discharge assembly (as an option) Centrifugal motorfans assembled for horizontal air outlet is an option in these units. This change is possible to be made also in site with no need for special parts. positi temperature central By front maintenance access Cooling Refrigeration scheme MDVCF8 AP mc Refrigeration scheme legend Extraction duct dimensions mv mv Recommended dimensions for metal sheet or fibreglass ducts, depending on equivalent length. 90º elbow estimated equivalent length is also shown. 5 series 6 series 8 series 20m equivalent length: 400 x 300 mm 500 x 400 mm 1000 x 400 mm 40m equivalent length: 400 x 350 mm 600 x 400 mm 1200 x 400 mm 60m equivalent length: 400 x 400 mm 700 x 400 mm 1400 x 400 mm 90º elbow equivalent length: 8 m 10 m 15 m It is recommended to select the grilles for air intake and discharge according to the following instructions: air outlet grille for an air speed not greater than 5 m/s (equivalent to an airflow surface of 0,3 m for series 5, of 0,5 m for series 6 and of 1 m for series 8). Cd vd rl sa rc fl air inlet grille for an air speed not greater than 3 m/s (equivalent to an airflow surface of 0,5 m for series 5, of 1 m for series 6 and of 2 m for series 8). vl cp V rc P BP P vc cp: compressor rc: crankcase heater MV: Centrifugal motorfan cd: condenser fl: DEHYDRATANT filter vl: SIGHT GLASS rl: liquid receir VD: safety val vc: service val MC: electronic microcontroller P: PRESSURE TRANSDUCER ap: HIGH PRESSURE SWITCH bp: LOW PRESSURE SWITCH sa: OIL SEPARATOR (as an option)

innovati refrigeration solutions MDV series positi temperature Codification MDV CFM 12345 Series Size Capacity CF Electronic rsion. CMF Electromechanical rsion (only for series 5). CVF Cooling capacity modulation rsion. Technical features 400VIII50 Hz, R404A 1 compressor 2 compressors 3 compressors Series / Model Compressor HP Type* Model MDVCF50086 4 H MTZ50 MDVCF50108 5 H MTZ64 MDVCF50136 6,5 H MTZ80 MDVCF60160 8 H MTZ100 MDVCF60215 10 H MTZ125 MDVCF60271 13 H MTZ160 MDVCF50097 4 H MDVCF50109 4,5 H MDVCF50120 6 H MDVCF50137 7 H MDVCF60172 8 H MDVCF60216 10 H MDVCF60272 13 H MDVCF80320 16 H MDVCF80430 20 H MDVCF80542 26 H MDVCF80258 12 H MDVCF80324 15 H MDVCF80408 20 H MDVCF80480 24 H MDVCF80645 30 H MTZ28 MTZ32 MTZ36 MTZ40 MTZ50 MTZ64 MTZ80 MTZ100 MTZ125 MTZ160 MTZ50 MTZ64 MTZ80 MTZ100 MTZ125 Ambient temp. Cooling capacity (kw)* Evaporating temperature +5 ºC 0 ºC 5 ºC 10 ºC 15 ºC 20 ºC 25 ºC 30 ºC 12,6 10,1 15,1 12,3 24,2 19,8 2 2 3 11,0 14,7 11,9 1 2 19,9 30,6 4 3 58,6 4 6 40,4 49,1 39,5 57,1 47,0 65,1 53,7 7 12,6 10,2 14,9 20,4 25,0 20,1 2 9,1 12,4 10,0 11,1 1 25,6 20,5 30,2 40,8 50,0 40,2 59,1 4 33,6 26,9 39,2 32,9 49,1 39,9 55,8 44,9 66,3 6,9 10,4 12,7 20,6 16,5 2 20,1 7,3 12,7 17,2 21,1 25,6 20,6 33,7 27,3 41,1 49,7 40,2 27,2 21,7 3 26,8 41,2 33,1 46,6 37,6 5 44,7 6,9 5,5 6,6 11,1 16,9 20,6 7,5 5,8 6,6 7,6 1 27,3 22,1 33,8 26,7 41,2 33,4 21,8 17,2 26,7 21,1 33,7 27,0 38,2 30,4 46,5 36,6 5,5 4,3 6,7 8,6 6,8 8,6 4,5 6,7 5,3 6,1 7,0 1 21,7 27,0 33,6 26,8 27,2 21,7 30,7 2 37,6 4,2 3,3 6,8 6,5 4,5 3,3 6,1 7,0 5,5 6,3 8,1 13,0 26,9 21,4 13,1 10,2 1 12,5 21,5 23,8 1 29,8 23,4 2,4 2,9 5,3 4,1 4,7 8,1 10,4 8,2 2,3 2,9 3,5 4,2 6,4 8,2 12,3 16,3 12,4 20,8 16,4 9,7 7,2 12,1 9,2 16,4 12,8 1 13,6 2 18,0 2,3 1,6 2,8 2,0 3,0 3,0 4,5 2,2 1,4 2,8 1,9 3,3 2,4 3,0 3,1 5,7 7,9 8,8 12,0 8,9 15,6 11,8 6,8 6,1 9,1 12,7 17,2 13,0 Nominal power consump. (kw)* Max. absorbed current (A) Available static pressure* (mmwc) Condenser Air flow Weight (m³/h) (kg) LiqGas cooling SPL db(a)* 1 20 5.000 168 1 /2 7 /8 67 4,9 22,4 20 5.000 169 1 /2 7 /8 65 6,4 26,4 20 5.000 173 1 /2 1 1/8 63 27,4 15 266 5 /8 1 1/8 73 10,2 32,4 15 270 5 /8 1 3/8 73 13,0 41,4 15 275 5 /8 1 3/8 73 22,4 20 5.000 179 1 /2 7 /8 60 5,0 23,4 20 5.000 180 1 /2 7 /8 60 2 20 5.000 182 1 /2 1 1/8 60 6,7 27,4 20 5.000 185 1 /2 1 1/8 59 8,9 2 15 276 5 /8 1 1/8 74 10,2 3 15 280 5 /8 1 3/8 73 1 43,4 15 286 5 /8 1 3/8 73 16,9 5 15 20,4 6 15 26,1 82,8 15 13,0 46,8 15 16,1 55,8 15 20,4 6 15 24,1 76,8 15 29,5 91,8 15 495 7 /8 1 5/8 76 505 7 /8 1 5/8 76 515 7 /8 2 1/8 76 480 5 /8 1 3/8 76 485 7 /8 1 5/8 76 495 7 /8 1 5/8 76 555 7 /8 2 1/8 77 570 1 1 /8 2 1 /8 77 As an option Oil separator. Anticorrosion coil coating. Backflow damper in fan outlet. * Cooling capacity at nominal conditions of evaporating temperature 10 ºC (PT), ambient temperature, superheating 10K and subcooling 3K. Available static pressure in extraction ducts. SPL: Sound pressure lel shown in db(a) at 10 metre distance from the souce in free field. Compressor type according to the following nomenclature: H = Hermetic reciprocating compressor.

refrigeration centrals negati temperature BDV series Codification BDV CFM 12345 Serie Taille Capacité CF/SCF Electronic rsion. CMF/SCMF Electromechanical rsion (only for series 5). CVF Cooling capacity modulation rsion (only for reciprocating compressor models). Technical features 400VIII50 Hz, R404A Series / Model Compressor HP Type* Model Ambient temp. Cooling capacity (kw)* Evaporating temperature 10 ºC 15 ºC 20 ºC 25 ºC 30 ºC 40 ºC Nominal power consump. (kw)* Max. absorbed current (A) Available static pressure* (mmwc) Condenser Air flow Weight (m³/h) (kg) LiqGas cooling SPL db(a)* BDVSCF50131 4 ZF13KVE 9,7 8,9 7,6 7,1 6,4 4,9 3,5 3,1 2,7 16,4 20 5.000 175 1 /2 1 1/8 59 BDVCF50215 7,5 H NTZ215 11,2 6,7 7,4 2,8 1,9 5,8 29,7 20 5.000 195 1 /2 1 1/8 68 BDVSCF50181 6 ZF18KVE 13,3 12,4 8,2 6,9 6,6 5,8 5,7 4,9 4,9 5,3 20,4 20 5.000 180 1 /2 1 1/8 60 1 compressor BDVCF50271 10 H NTZ271 BDVSCF60241 7,5 BDVSCF60331 10 ZF24KVE ZF33KVE 1 18,1 16,4 23,1 21,0 15,6 14,2 20,0 1 13,3 17,1 15,8 7,5 10,4 14,5 11,7 7,3 10,1 7,9 7,5 3 20 5.000 195 1 /2 1 1/8 68 21,4 15 250 1 /2 1 3/8 72 9,9 26,8 15 275 1 /2 1 3/8 72 BDVSCF60401 13 ZF40KVE 27,9 25,5 24,1 22,2 20,7 19,1 17,6 16,3 1 12,3 10,0 10,1 32,4 15 275 1 /2 1 3/8 72 BDVSCF60481 15 ZF48KVE 32,6 30,7 2 26,7 2 23,0 20,8 19,7 17,6 1 13,6 12,1 3 15 275 1 /2 1 5/8 72 BDVCF50192 7 H NTZ96 13,1 8,1 6,3 6,5 5,0 3,6 3,7 2,6 2,6 1,6 5,0 27,6 20 5.000 205 1 /2 1 1/8 70 BDVCF50216 H NTZ108 11,4 8,9 7,3 7,6 5,8 3,1 2,0 5,7 31,6 20 5.000 205 1 /2 1 1/8 69 BDVCF50272 10 H NTZ136 1 7,5 7,5 3 20 5.000 205 1 /2 1 1/8 65 2 compressors BDVSCF60262 8 BDVSCF60362 12 BDVSCF80482 15 ZF13KVE ZF18KVE ZF24KVE 19,5 1 26,5 2 36,1 32,8 1 22,6 31,1 2 14,1 12,8 19,2 18,0 26,6 2 11,8 16,3 1 22,5 20,7 9,7 1 18,8 17,5 7,0 15,5 14,5 9,8 9,8 12,5 10,8 7,9 32,8 15 285 1 /2 1 3/8 72 40,8 15 285 1 /2 1 3/8 72 15,3 42,8 15 550 1 /2 1 5/8 75 BDVSCF80662 20 ZF33KVE 4 42,0 39,9 36,9 34,2 31,6 28,9 26,9 23,4 22,6 20,1 18,8 16,5 15,8 19,8 53,6 15 600 5 /8 2 1/8 75 BDVSCF80802 26 ZF40KVE 55,8 51,0 48,2 4 41,4 38,1 3 32,5 27,4 2 20,0 20,2 22,7 6 15 600 5 /8 2 1/8 75 BDVSCF80962 30 ZF48KVE 6 61,4 56,6 53,4 48,8 4 41,6 3 33,3 29,2 27,1 24,1 21,8 27,6 72,0 15 600 5 /8 2 1/8 75 BDVCF80645 23 H NTZ215 4 36,8 2 30,0 22,8 2 1 1 1 9,87 9,8 1 76,9 15 565 7 /8 2 1/8 75 3 compressors BDVSCF80543 18 BDVCF80813 30 H BDVSCF80723 23 BDVSCF80993 30 ZF18KVE NTZ271 ZF24KVE ZF33KVE 40,7 3 5 47,4 51,9 46,5 66,3 62,4 34,7 32,6 46,7 38,1 4 40,5 57,5 54,2 2 27,6 38,2 30,1 38,9 49,5 46,7 2 23,5 31,1 23,3 30,0 42,2 39,9 20,9 20,0 17,5 2 25,5 35,6 33,8 17,6 17,1 1 12,6 22,9 20,4 28,2 14,7 1 18,6 16,1 23,7 17,6 49,8 15 23,7 91,0 15 21,8 58,8 15 27,1 75,0 15 590 5 /8 2 1/8 75 570 7 /8 2 1/8 75 590 7 /8 2 1/8 75 660 7 /8 2 1/8 75 BDVSCF81203 39 ZF40KVE 7 6 65,1 5 56,6 50,7 48,6 43,1 41,3 3 30,9 2 2 3 91,8 15 660 7 /8 2 1/8 75 As an option Oil separator (already included for 2 scroll compressors and 3 compressors models). Anticorrosion coil coating. Backflow damper in fan outlet. * Cooling capacity at nominal conditions of evaporating temperature 30 ºC (NT), ambient temperature, superheating 10K and subcooling 3K. Available static pressure in extraction ducts. SPL: Sound pressure lel shown in db(a) at 10 metre distance from the souce in free field. Compressor type according to the following nomenclature: H = Hermetic reciprocating compressor. = roll compressor with vapour injection system. * Resctricted model to 42 ºC ambient temperature.

innovati refrigeration solutions MDV / BDV series Dimensions series 5 1070 700 315 346 series 6 series 8 2100 800 476 1150 409 1765 1765 1270 1070 800 476 409 Electronic regulation Standard electronic regulation for centrals in their CF and SCF rsions, for compressor/s and motorfan/s control. Electronic regulation Control of up to 3 power steps with suction pressure set point. Proportional control of condensing temperature by fan/s speed variator. External communication module through ModBus protocol and RS485 (as an option).

multiservice refrigeration centrals cooling capacity modulation MDVCVF / BDVCVF rsions Cooling capacity modulation Installing example Multiservice centrals, series MDVCVF and BDVCVF, featuring system (Variable Refrigerant Capacity) for cooling capacity modulation on hermetic recirpocating compressors, composed by: Suction pressure val (VP). Bypass pressure val (VC). Thermostatic expansion val for liquid injection (VE). Pressure control switch (IP). Versions of the multiservice centrals: series MDVCVF 6 and 8. series BDVCVF 6 and 8. Multiservice aircooled centrals are specifically designed for cooling production centrlization of a set of positi or negati temperature evaporating units. REFRIGERATED DISPLAYS 0 ºC vp CABINET 10 ºC system: Variable Refrigerant Capacity The system adjusts the refrigerant flow to the demand of the evaporating units, keeping constant the pressure in suction line. For refrigeration centrals with two or more compressors, the system is installed on one of the compressors, which modulates progresily its cooling capacity, while the other compressors are operating as power steps for a progresi modulation of all the unit cooling capacity. The system for two or more compressors features: progresi control of cooling capacity, with no pressure pulses, PI electronic regulation to keep constant the evaporation pressure to the set point, P abs 5% 55% P frig 100% it protects the compressor from motor reheat risk, it keeps the compressing ratio between the secure operating margins. T ev COLD ROOM 0 ºC PROCESS ROOM 12 ºC T set point REFRIGERATED SHOWCASES 0 ºC vp 10% P frig 100% system can be easily set, through a digital display, for a minimum suction pressure/temperature. The system is designed for compressors stop in case of low pressure (pump down) under the minimum set point. t: THERMOSTAT : THERMOSTATIC EXPANSION VALVE : vp: SOLENOID VALVE CONSTANT PRESSURE VALVE Principle scheme VC VP VE